Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
2.
Artículo en Inglés | MEDLINE | ID: mdl-37174152

RESUMEN

Clinical and economic burdens exist within the coronary artery disease (CAD) care pathway despite advances in diagnosis and treatment and the increasing utilization of percutaneous coronary intervention (PCI). However, research presenting a comprehensive assessment of the challenges across this pathway is scarce. This contemporary review identifies relevant studies related to inefficiencies in the diagnosis, treatment, and management of CAD, including clinician, patient, and economic burdens. Studies demonstrating the benefits of integration and automation within the catheterization laboratory and across the CAD care pathway were also included. Most studies were published in the last 5-10 years and focused on North America and Europe. The review demonstrated multiple potentially avoidable inefficiencies, with a focus on access, appropriate use, conduct, and follow-up related to PCI. Inefficiencies included misdiagnosis, delays in emergency care, suboptimal testing, longer procedure times, risk of recurrent cardiac events, incomplete treatment, and challenges accessing and adhering to post-acute care. Across the CAD pathway, this review revealed that high clinician burnout, complex technologies, radiation, and contrast media exposure, amongst others, negatively impact workflow and patient care. Potential solutions include greater integration and interoperability between technologies and systems, improved standardization, and increased automation to reduce burdens in CAD and improve patient outcomes.


Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Humanos , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad de la Arteria Coronaria/diagnóstico , Intervención Coronaria Percutánea/métodos , Vías Clínicas , Resultado del Tratamiento , Pacientes , Factores de Riesgo
3.
Eur Spine J ; 31(11): 3098-3108, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36149493

RESUMEN

STUDY DESIGN: Prospective multi-center study. OBJECTIVE: The study aimed to evaluate the accuracy of pedicle screw placement using a skin marker-based optical surgical navigation system for minimal invasive thoraco-lumbar-sacral pedicle screw placement. METHODS: The study was performed in a hybrid Operating Room with a video camera-based navigation system integrated in the imaging hardware. The patient was tracked with non-invasive skin markers while the instrument tracking was via an on-shaft optical marker pattern. The screw placement accuracy assessment was performed by three independent reviewers, using the Gertzbein grading. The screw placement time as well as the staff and patient radiation doses was also measured. RESULTS: In total, 211 screws in 39 patients were analyzed for screw placement accuracy. Of these 32.7% were in the thoracic region, 59.7% were in the lumbar region, and 7.6% were in the sacral region. An overall accuracy of 98.1% was achieved. No screws were deemed severely misplaced (Gertzbein grading 3). The average time for screw placement was 6 min and 25 secs (± 3 min 33 secs). The average operator radiation dose per subject was 40.3 µSv. The mean patient effective dose (ED) was 11.94 mSv. CONCLUSION: Skin marker-based ON can be used to achieve very accurate thoracolumbarsacral pedicle screw placements.


Asunto(s)
Tornillos Pediculares , Fusión Vertebral , Cirugía Asistida por Computador , Humanos , Estudios Prospectivos , Región Sacrococcígea , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/cirugía , Imagenología Tridimensional/métodos , Cirugía Asistida por Computador/métodos , Fusión Vertebral/métodos
4.
Spine (Phila Pa 1976) ; 44(7): 517-525, 2019 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-30234816

RESUMEN

STUDY DESIGN: Prospective observational study. OBJECTIVE: The aim of this study was to evaluate the accuracy of pedicle screw placement using augmented reality surgical navigation (ARSN) in a clinical trial. SUMMARY OF BACKGROUND DATA: Recent cadaveric studies have shown improved accuracy for pedicle screw placement in the thoracic spine using ARSN with intraoperative 3D imaging, without the need for periprocedural x-ray. In this clinical study, we used the same system to place pedicle screws in the thoracic and lumbosacral spine of 20 patients. METHODS: The study was performed in a hybrid operating room with an integrated ARSN system encompassing a surgical table, a motorized flat detector C-arm with intraoperative 2D/3D capabilities, integrated optical cameras for augmented reality navigation, and noninvasive patient motion tracking. Three independent reviewers assessed screw placement accuracy using the Gertzbein grading on 3D scans obtained before wound closure. In addition, the navigation time per screw placement was measured. RESULTS: One orthopedic spinal surgeon placed 253 lumbosacral and thoracic pedicle screws on 20 consenting patients scheduled for spinal fixation surgery. An overall accuracy of 94.1% of primarily thoracic pedicle screws was achieved. No screws were deemed severely misplaced (Gertzbein grade 3). Fifteen (5.9%) screws had 2 to 4 mm breach (Gertzbein grade 2), occurring in scoliosis patients only. Thirteen of those 15 screws were larger than the pedicle in which they were placed. Two medial breaches were observed and 13 were lateral. Thirteen of the grade 2 breaches were in the thoracic spine. The average screw placement time was 5.2 ±â€Š4.1 minutes. During the study, no device-related adverse event occurred. CONCLUSION: ARSN can be clinically used to place thoracic and lumbosacral pedicle screws with high accuracy and with acceptable navigation time. Consequently, the risk for revision surgery and complications could be minimized. LEVEL OF EVIDENCE: 3.


Asunto(s)
Realidad Aumentada , Tornillos Pediculares , Implantación de Prótesis/métodos , Cirugía Asistida por Computador/métodos , Adolescente , Adulto , Anciano , Femenino , Humanos , Imagenología Tridimensional/métodos , Vértebras Lumbares , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sacro , Enfermedades de la Columna Vertebral/cirugía , Fusión Vertebral/métodos , Cirugía Asistida por Computador/instrumentación , Vértebras Torácicas , Tomografía Computarizada por Rayos X/métodos , Adulto Joven
5.
Trials ; 9: 68, 2008 Dec 02.
Artículo en Inglés | MEDLINE | ID: mdl-19055703

RESUMEN

BACKGROUND: Magnetic Resonance Imaging (MRI) of patients with implanted cardiac devices is currently considered hazardous due to potential for electromagnetic interference to the patient and pacemaker system. With approximately 60 million MRI scans performed worldwide per year, an estimated majority of pacemaker patients may develop an indication for an MRI during the lifetime of their pacemakers, suggesting that safe use of pacemakers in the MRI environment would be clinically valuable. A new pacing system (Medtronic EnRhythm MRI(TM) SureScan(TM) and CapSureFix MRI(TM) leads) has been designed and pre-clinically tested for safe use in the MRI environment. The EnRhythm MRI study is designed to confirm the safety and efficacy of this new pacing system. METHODS: The EnRhythm MRI study is a prospective, randomized controlled, unblinded clinical trial to confirm the safety and efficacy of MRI at 1.5 Tesla in patients implanted with a specifically designed pacemaker and lead system. The patients have standard indications for dual chamber pacemaker implantation. Successfully implanted patients are randomized in a 2:1 ratio to undergo MRI (MRI group) or to have no MRI scan (control group) at 9-12 weeks after pacemaker system implantation. Magnetic resonance (MR) scanning includes 14 head and lumbar scan sequences representing clinically relevant scans while maximizing the gradient slew rate up to 200 T/m/s, and/or the transmitted radiofrequency (RF) power up to SAR (specific absorption rate) levels of 2 W/kg body weight (upper limit of normal operating mode). Full interrogation of all device information and sensing and capture function are measured at device implantation, every follow-up and before and immediately after MRI in the MRI group and at the same time points in the control group. Complete pacemaker and lead evaluations are also done at one week and one month after the scan for the MRI and control group patients.The primary endpoint is safe and successful completion of the MRI scan as measured by freedom from both MRI-procedure related complications and clinically significant changes in the sensing and capture function of the leads. RESULTS: Results will be communicated after approximately 156 and 470 patients have completed 4 months of follow-up. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT00433654.

6.
Heart Rhythm ; 4(7): 879-85, 2007 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-17599671

RESUMEN

BACKGROUND: Previous studies in implantable cardioverter-defibrillator (ICD) patients demonstrated the efficacy and safety of antitachycardia pacing (ATP) for rapid ventricular tachycardias (VT). To prevent shock delay in case of ATP failure, a new feature (ATP during charging) was developed to deliver ATP for rapid VT while charging for shock. OBJECTIVE: The purpose of this study was to determine the efficacy and safety of this new feature. METHODS: In a prospective, nonrandomized trial, patients with standard ICD indication received an EnTrust ICD. VT and ventricular fibrillation (VF) episodes were reviewed for appropriate detection, ATP success, rhythm acceleration, and related symptoms. RESULTS: In 421 implanted patients, 116 VF episodes occurred in 37 patients. Eighty-four (72%) episodes received ATP during or before charging. ATP prevented a shock in 58 (69%) of 84 episodes in 15 patients. ATP stopped significantly more monomorphic (77%) than polymorphic VTs (44%, P = .05). Five (6%) episodes accelerated after ATP but were terminated by the backup shock(s). No symptoms were related to ATP during charging. In four patients, 38 charges were saved by delivering ATP before charging. Of 98 induced VF episodes, 28% were successfully terminated by ATP versus 69% for spontaneous episodes (P <.01). CONCLUSION: Most VTs detected in the VF zone can be painlessly terminated by ATP delivered during charging, with a low risk of acceleration or symptoms. ATP before charging allows delivery of two ATP attempts before shock in the same time that would otherwise be required to deliver only one ATP plus a shock. It also offers potential battery energy savings.


Asunto(s)
Estimulación Cardíaca Artificial/métodos , Desfibriladores Implantables , Taquicardia Ventricular/terapia , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...