Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-18473208

RESUMEN

One of the most convenient methods for the identification of animal species in processed meat products is the examination of DNA sequences. Real-time polymerase chain reaction (qPCR) techniques are particularly suitable because even small fragments of DNA formed during heat processing of the meat can be amplified and identified. A real-time PCR method has been developed and evaluated for the identification of processed meat products. In test mixtures containing beef, pork, horse, mutton, chicken and turkey, it was possible to identify these species down to a level of 0.05%. By adjusting the number of cycles, it was possible to detect levels as low as 0.01% of these species. Cross-reactivity between these species was not found, except for pure horsemeat (250 ng DNA) in the assay for turkey meat. Cross-reactivity of deer, roe, ostrich, kangaroo, goat, domestic duck, mallard, goose, pigeon, guinea fowl, quail and pheasant was also investigated and it was found that amounts as high as 250 ng DNA of these species in the reaction vial did not result in (false) positive signals except for amounts higher than 125 ng deer DNA and higher than 50 ng pigeon DNA in the determination of chicken and beef, respectively. More than 150 meat samples were examined using DNA hybridization and real-time PCR. A comparison of the results showed a better performance of the real-time procedure compared to DNA hybridization.


Asunto(s)
Dermatoglifia del ADN/métodos , Análisis de los Alimentos/métodos , Productos de la Carne/análisis , Reacción en Cadena de la Polimerasa/métodos , Productos Avícolas/análisis , Animales , Reacciones Cruzadas , Sondas de ADN , Aves de Corral , Especificidad de la Especie
2.
Food Addit Contam ; 21(4): 331-40, 2004 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-15204557

RESUMEN

Paralytic shellfish poisoning toxins are produced by dinoflagellates. Shellfish filtering these unicellular algae will accumulate the toxins and pose a health risk when consumed by man. In the European Union, paralytic shellfish poisoning toxins in bivalve molluscs are regulated at a maximum content of 80 microg/100 g (91/492/EEC). The current reference method in the European Union is the mouse bioassay, but alternative methods including the liquid chromatography methodology are preferred for ethical reasons. Analyses of suspected shellfish batches revealed, however, unacceptable differences in results reported by a small group of Dutch laboratories all using liquid chromatography methods with precolumn derivatization, followed by fluorescence detection. Therefore, a series of proficiency studies were undertaken among these laboratories. In the first three studies, participants were more or less allowed their own choice of method execution details. This approach yielded unsatisfactory results. A fourth study was then initiated in which a standardized method was mandatory. Two types of test material were used in the fourth study: lyophilized Cardium tuberculatum material containing saxitoxin (STX) and decarbamoyl-saxitoxin (dc-STX), and lyophilized mussel material containing dc-STX. The latter material was investigated in an interlaboratory study involving 15 participants and was considered as the reference material. Among the four laboratories, coefficients of variation (ANOVA) for C. tuberculatum material were 10% (n = 11) and 9% (n = 12) for STX and dc-STX, respectively, and for the reference material was 8% (n = 12) for dc-STX. The joint efforts showed that variability in analysis results between laboratories that all apply more or less the same method can be drastically improved if the methodology is rigorously standardized.


Asunto(s)
Toxinas Marinas/análisis , Neurotoxinas/análisis , Saxitoxina/análogos & derivados , Mariscos/análisis , Cromatografía Liquida/métodos , Cromatografía Liquida/normas , Análisis de los Alimentos/métodos , Análisis de los Alimentos/normas , Humanos , Laboratorios/normas , Toxinas Marinas/aislamiento & purificación , Países Bajos , Neurotoxinas/aislamiento & purificación , Control de Calidad , Reproducibilidad de los Resultados , Saxitoxina/análisis , Saxitoxina/aislamiento & purificación
3.
J AOAC Int ; 83(1): 241-4, 2000.
Artículo en Inglés | MEDLINE | ID: mdl-10693027

RESUMEN

A method was developed to determine 4-hexylresorcinol in shrimp meat. The procedure is based on extraction of test portions with methanol followed by liquid chromatographic analysis of the extracts, using a reversed-phase column and fluorimetric detection (excitation: 280 nm, and emission: 310 nm). The confidence interval of the recovery in working range of 1.5-2.5 mg/kg was 81.6 +/- 0.8%. The relative standard deviation in the working range was 2.1%. Limits of quantitation and detection were 6.59 and 1.98 ng/mL extract, respectively, corresponding to 0.26 and 0.08 mg/kg in shrimp.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Decápodos/química , Hexilresorcinol/análisis , Animales , Residuos de Medicamentos/análisis , Control de Calidad , Sensibilidad y Especificidad
4.
J AOAC Int ; 81(5): 991-8, 1998.
Artículo en Inglés | MEDLINE | ID: mdl-9772741

RESUMEN

An interlaboratory study of the liquid chromatographic (LC) determination of histamine in fish, sauerkraut, and wine was conducted. Diminuted and homogenized samples were suspended in water followed by clarification of extracts with perchloric acid, filtration, and dilution with water. After LC separation on a reversed-phase C18 column with phosphate buffer (pH 3.0)--acetonitrile (875 + 125, v/v) as mobile phase, histamine was measured fluorometrically (excitation, 340 nm; emission, 455 nm) in samples and standards after postcolumn derivatization with o-phthaldialdehyde (OPA). Fourteen samples (including 6 blind duplicates and 1 split level) containing histamine at about 10-400 mg/kg or mg/L were analyzed singly according to the proposed procedure by 11 laboratories. Results from one participant were excluded from statistical analysis. For all samples analyzed, repeatability relative standard deviations varied from 2.1 to 5.6%, and reproducibility relative standard deviations ranged from 2.2 to 7.1%. Averaged recoveries of histamine for this concentration range varied from 94 to 100%.


Asunto(s)
Cromatografía Liquida , Contaminación de Alimentos , Histamina/análisis , Animales , Brassica/química , Peces/metabolismo , Laboratorios , Reproducibilidad de los Resultados , Vino/análisis
6.
J Clin Chem Clin Biochem ; 16(9): 531-2, 1978 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-361925

RESUMEN

Addition of a low concentration of sodium azide completely stops colour development in a peroxidase-labelled enzyme immunoassay using 2,2'-azino-di(3-ethylbenzthiazoline sulphonic acid-6) as substrate. Whereas high concentrations of azide cause a decrease in the colour intensity, the low concentrations used here have no significant affect on the colour.


Asunto(s)
Azidas , Técnicas para Inmunoenzimas , Peroxidasas , Digoxina/sangre , Humanos , Indicadores y Reactivos , Métodos
7.
J Chromatogr ; 142: 671-88, 1977 Nov 11.
Artículo en Inglés | MEDLINE | ID: mdl-914941

RESUMEN

The retention behaviour of amino acids in phase systems consisting of a hydrophobic solid support as the stationary phase and water-organic solvent mixtures containing a small amount of an anionic detergent as the mobile phase was investigated. Such phase systems are found to behave like conventional ion-exchange systems. The degree and order of retention of amino acids can be influenced by changing the temperature, the nature of the hydrophobic support, the pH and the nature and concentration of the anionic detergent, organic constituent and counter ion in the eluent. In many instances this solvent-generated (dynamic) ion-exchange chromatography shows a greater selectivity than conventional ion-exchange systems towards amino acids. The results obtained so far indicate that a complete separation of the 19 protein amino acids by applying solvent gradients or/and multi-column system is possible within 30 min.


Asunto(s)
Aminoácidos/aislamiento & purificación , Aniones , Cromatografía por Intercambio Iónico , Solventes , Tensoactivos , Temperatura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...