Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Intervalo de año de publicación
1.
Artículo | WPRIM (Pacífico Occidental) | ID: wpr-830745

RESUMEN

Background@#After the laws regulating emergency medicine were amended in 2012, regional trauma centers were established in South Korea. Plastic surgeons specialize in the simultaneous surgical care of patients with facial trauma, burns, and complicated wounds. The objective of this study was to evaluate the role of the plastic surgery department in treating severe trauma patients. @*Methods@#From January 2012 to December 2018, we enrolled 366 severe trauma patients with an Injury Severity Score (ISS) over 15 who received treatment by specialists in the plastic surgery department. Of these patients, 298 (81.4%) were male, and their mean age was 51.35 years (range, 6–91 years). The average ISS was 22.01 points (range, 16–75 points). @*Results@#The most common diagnosis was facial trauma (95.1%), and facial bone fracture (65.9%) was most common injury within this subgroup. Patients were referred to 1.8 departments on average, with the neurosurgery department accounting for a high proportion of collaborations (37.0%). The most common cause of trauma was traffic accidents (62.3%), and the average length of stay in the general ward and intensive care unit was 36.90 and 8.01 days, respectively. Most patients were discharged home (62.0%) without additional transfer or readmission. @*Conclusions@#Through this study, we scoped out the role of the specialty of plastic surgery in the multidisciplinary team at regional trauma centers. These results may have implications for trauma system planning.

2.
Artículo | WPRIM (Pacífico Occidental) | ID: wpr-830648

RESUMEN

Background@#We have reported orbital wall restoration surgery with primary orbital wall fragment in pure blowout fractures using a combination of transorbital and transnasal approach in pure blow out fractures. However, this method was thought to be difficult to use for complex orbital wall fractures, since the sharp screw tip that fixate the maxillary wall increases the risk of balloon ruptures. In this study, we reviewed 23 cases of complex orbital fractures that underwent orbital wall restoration surgery with primary orbital wall fragment and evaluated the result. @*Methods@#A retrospective review was conducted of 23 patients with complex orbital fracture who underwent orbital restoration surgery with primary orbital wall fragments between 2012 and 2019. The patients underwent orbital wall restoration surgery with primary orbital wall fragment with temporary balloon support. The surgical results were evaluated by the Naugle scale and a comparison of preoperative and postoperative orbital volume ratio. Complex fracture type, type of screw used for fixation and complications such as balloon rupture were also investigated. @*Results@#There were 23 patients with complex orbital fracture that used transnasal balloon technique for restoration. 17 cases had a successful outcome with no complications, three patients had postoperative balloon rupture, two patients had soft-tissue infection, and one patient had balloon malposition. @*Conclusion@#The orbital wall restoration technique with temporary balloon support can produce favorable results when done correctly even in complex orbital wall fracture. Seventeen cases had favorable results, six cases had postoperative complications thus additional procedure seems necessary to complement this method.

3.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-762792

RESUMEN

Intraorbital infection shows a low incidence, but it might cause blindness or even death. This case is unusual in that its origin from a craniofacial bone fracture prior to infection of the maxillary sinus. A 33-year-old female patient was referred for right cheek swelling. When she visited the emergency room, we removed right cheek hematoma and bacterial examination was done. In the past, she had craniofacial bone surgical history due to a traffic accident 6 years ago. Next day, the swelling had remained with proptosis and pus was recognized in the conjunctiva. We planned an emergency operation and removed the pus which was already spread inside the orbit. And the evaluation for sinusitis was consulted to the otorhinolaryngology department simultaneously. There were Prevotella oralis and methicillin-resistant Staphylococcus epidermidis bacterial infection in the intraorbital and sinus respectively. Afterwards, the vigorous dressing was done for over a month with intravenous antibiotics. Though the intraorbital infection was resolved, blindness and extraocular movement limitation were inevitable. In conclusion, close follow up of the maxillary sinus in facial bone fracture patients is important and aggressive treatment is needed when an infection is diagnosed.


Asunto(s)
Adulto , Femenino , Humanos , Accidentes de Tránsito , Antibacterianos , Infecciones Bacterianas , Vendajes , Ceguera , Mejilla , Conjuntiva , Urgencias Médicas , Servicio de Urgencia en Hospital , Exoftalmia , Infecciones del Ojo , Huesos Faciales , Estudios de Seguimiento , Fracturas Óseas , Hematoma , Incidencia , Seno Maxilar , Resistencia a la Meticilina , Órbita , Otolaringología , Prevotella , Sinusitis , Staphylococcus epidermidis , Supuración
4.
J Nanosci Nanotechnol ; 7(1): 344-9, 2007 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-17455502

RESUMEN

Current induced magnetic reversal due to spin transfer torque is a promising candidate in advanced information storage technology. It has been intensively studied. This work reports the field-dependence of switching-currents for current induced magnetization switching in a uncoupled nano-sized cobalt-based spin valve of exchange biased type. The dependency is investigated in hysteretic regime at room temperature, in comparison with that of a trilayer simple spin valve. In the simple spin valve, the switching currents behave to the positive and the negative applied magnetic field symmetrically. In the exchange biased type, in contrast, the switching currents respond to the negative field in a quite unusual and different manner than to the positive field. A negative magnetic field then can shift the switching-currents into either negative or positive current range, dependently on whether a parallel or an antiparallel state of the spin valve was produced by that field. This different character of switching currents in the negative field range can be explained by the effect of the exchange bias pinning field on the spin-polarizer (the fixed Co layer) of the exchange biased spin valve. That unidirectional pinning filed could suppress the thermal magnetization fluctuation in the spin-polarizer, leading to a higher spin polarization of the current, and hence a lower switching current density than in the simple spin valve.


Asunto(s)
Equipos de Almacenamiento de Computador , Electroquímica/métodos , Almacenamiento y Recuperación de la Información , Magnetismo , Nanotecnología/métodos , Simulación por Computador , Campos Electromagnéticos , Temperatura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...