J Orofac Orthop ; 2023 Jan 26.
Artículo en Inglés | MEDLINE | ID: mdl-36700953

RESUMEN

PURPOSE: To assess magnetic resonance imaging (MRI) artefacts caused by different computer-aided design/computer-aided manufacturing (CAD/CAM) retainers in comparison with conventional hand bent stainless steel twistflex retainers in vivo. MATERIALS AND METHODS: MRI scans (3 Tesla) were performed on a male volunteer with different CAD/CAM retainers (cobalt-chromium, CoCr; nickel-titanium, NiTi; grade 5 titanium, Ti5) and twistflex retainers inserted. A total of 126 landmarks inside and outside the retainer area (RA; from canine to canine) were evaluated by two blinded radiologists using an established five-point visibility scoring (1: excellent, 2: good, 3: moderate, 4: poor, 5: not visible). Friedman and two-tailed Wilcoxon tests were used for statistical analysis (significance level: p < 0.05). RESULTS: Twistflex retainers had the strongest impact on the visibility of all landmarks inside (4.0 ± 1.5) and outside the RA (1.7 ± 1.2). In contrast, artefacts caused by CAD/CAM retainers were limited to the dental area inside the RA (CoCr: 2.2 ± 1.2) or did not impair MRI-based diagnostics in a clinically relevant way (NiTi: 1.0 ± 0.1; Ti5: 1.4 ± 0.6). CONCLUSION: The present study on a single test person demonstrates that conventional stainless steel twistflex retainers can severely impair the diagnostic value in head/neck and dental MRI. By contrast, CoCr CAD/CAM retainers can cause artefacts which only slightly impair dental MRI but not head/neck MRI, whereas NiTi and Ti5 CAD/CAM might be fully compatible with both head/neck and dental MRI.

3.
J Dent ; 130: 104422, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36649822

RESUMEN

OBJECTIVES: To determine the reliability and accuracy of intraoral radiography (IR), cone-beam-computed tomography (CBCT), and dental magnetic resonance imaging (dMRI) in measuring peri­implant bone defects around single zirconia implants. METHODS: Twenty-four zirconia implants were inserted in bovine ribs with various peri­implant defect sizes and morphologies. True defect extent was measured without implant in CBCT. Defects were measured twice in IR, CBCT, and dMRI with the inserted implant by three experienced readers. Reliability was assessed by ICC, accuracy by the Friedman test, and post-hoc-Tukey's test. RESULTS: A comparable good to excellent intra- and inter-reader reliability was observed for all modalities (intra-/inter-rater-CC range for IR; CBCT; dMRI: 0.81-0.91/0.79;0.87-0.97/0.96;0.87-0.95/0.94). Accuracy was generally high, with mean errors below 1 mm in all directions. However, measuring defect depth in the mesiodistal direction was significantly more accurate in dMRI (0.65 ± 0.38 mm) compared to IR (2.71 ± 1.91 mm), and CBCT (1.98 ± 1.97 mm), p-values ≤ 0.0001 respectively ≤ 0.01. CONCLUSIONS: Osseous defects around zirconia implants can be reliably measured in IR/CBCT/dMRI in the mesiodistal directions. In addition, CBCT and dMRI allow assessment of the buccolingual directions. dMRI provides a comparable accuracy in all directions, except for the mesiodistal defect depth, where it outperforms IR and CBCT.


Asunto(s)
Implantes Dentales , Animales , Bovinos , Reproducibilidad de los Resultados , Estudios de Factibilidad , Tomografía Computarizada de Haz Cónico/métodos , Imagen por Resonancia Magnética , Radiografía Dental
4.
Clin Oral Investig ; 27(5): 2375-2384, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36640179

RESUMEN

OBJECTIVES: To evaluate the diagnostic MRI compatibility of different fixed orthodontic retainers using a high-resolution 3D-sequence optimized for artifact reduction. MATERIALS AND METHODS: Maxillary and mandibular retainers made of five different materials were scanned in vitro and in vivo at 3 T MRI using an MSVAT-SPACE sequence. In vitro, artifact volumes were determined for all maxillary and mandibular retainers (AVmax; AVmand). In vivo, two independent observers quantified the extent of artifacts based on the visibility of 124 dental and non-dental landmarks using a five-point rating scale (1 = excellent, 2 = good, 3 = acceptable, 4 = poor, 5 = not visible). RESULTS: Rectangular-steel retainers caused the largest artifacts (AVmax/AVmand: 18,060/15,879 mm3) and considerable diagnostic impairment in vivo (mean landmark visibility score ± SD inside/outside the retainer areas: 4.8 ± 0.8/2.9 ± 1.6). Smaller, but diagnostically relevant artifacts were observed for twistflex steel retainers (437/6317 mm3, 3.1 ± 1.7/1.3 ± 0.7). All retainers made of precious-alloy materials produced only very small artifact volumes (titanium grade 1: 70/46 mm3, titanium grade 5: 47/35 mm3, gold: 23/21 mm3) without any impact on image quality in vivo (each retainer: visibility scores of 1.0 ± 0.0 for all landmarks inside and outside the retainer areas). CONCLUSIONS: In contrast to steel retainers, titanium and gold retainers are fully compatible for both head/neck and dental MRI when using MSVAT-SPACE. CLINICAL RELEVANCE: This study demonstrates that titanium and gold retainers do not impair the diagnostic quality of head/neck and dental MRI when applying an appropriate artifact-reduction technique. Steel retainers, however, are not suitable for dental MRI and can severely impair image quality in head/neck MRI of the oral cavity.


Asunto(s)
Retenedores Ortodóncicos , Titanio , Boca , Imagen por Resonancia Magnética/métodos , Acero Inoxidable , Oro
5.
Sci Rep ; 12(1): 14068, 2022 08 18.
Artículo en Inglés | MEDLINE | ID: mdl-35982139

RESUMEN

To evaluate whether high-resolution, non-contrast-enhanced dental MRI (dMRI) can reliably and accurately measure the canal length of incisors and canines compared with cone-beam computed tomography (CBCT). Three-Tesla dMRI was performed in 31 participants (mean age: 50.1 ± 14.2 years) with CBCT data. In total, 67 teeth were included (28 from the upper jaw and 39 from the lower jaw; 25 central incisors, 22 lateral incisors, and 20 canines). CBCT and dMRI datasets were reconstructed to visualize the root canal pathway in a single slice in the vestibulo-oral (V-O) and mesio-distal (M-D) direction. Root canal length was measured twice by two radiologists using dMRI and CBCT. Data were statistically analyzed by calculating intraclass correlation coefficients (ICCs) and performing Bland-Altman analysis. The reliability of dMRI measurements was excellent and comparable to that of CBCT measurements (intra-rater I/intra-rater II/inter-rater was 0.990/0.965/0.951 for dMRI vs. 0.990/0.994/0.992 for CBCT in the M-D direction and 0.991/0.956/0.967 for dMRI vs. 0.998/0.994/0.996 for CBCT in the V-O direction). According to Bland-Altman analysis, the mean (95% confidence interval) underestimation of root canal lengths was 0.67 mm (- 1.22 to 2.57) for dMRI and 0.87 mm (- 0.29 to 2.04) for CBCT in the M-D direction/V-O direction. In 92.5% of cases, dMRI measurements of canal length had an accuracy within 0-2 mm. Visualization and measurement of canal length in vivo using dMRI is feasible. The reliability of dMRI measurements was high and comparable to that of CBCT measurements. However, the spatial and temporal resolution of dMRI is lower than that of CBCT, which means dMRI measurements are less accurate than CBCT measurements. This means dMRI is currently unsuitable for measuring canal length in clinical practice.


Asunto(s)
Cavidad Pulpar , Incisivo , Tomografía Computarizada de Haz Cónico/métodos , Cavidad Pulpar/diagnóstico por imagen , Humanos , Incisivo/diagnóstico por imagen , Imagen por Resonancia Magnética , Proyectos Piloto , Reproducibilidad de los Resultados
6.
Clin Oral Investig ; 26(11): 6765-6772, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35861757

RESUMEN

OBJECTIVES: To prospectively assess the reliability and accuracy of high-resolution, dental MRI (dMRI) for endodontic working length (WL) measurements of premolars and molars under clinical conditions. MATERIALS AND METHODS: Three-Tesla dMRI was performed in 9 subjects who also had undergone cone-beam computed tomography (CBCT) (mean age: 47 ± 13.5 years). A total of 34 root canals from 12 molars (4/8, upper/lower jaw; 22 root canals) and 11 premolars (2/9 upper/lower jaw; 12 root canals) were included. CBCT and dMRI datasets were reconstructed to visualize the root canal in one single slice. Subsequently, two radiologists measured the root canal lengths in both modalities twice in blinded fashion. Reliability and accuracy for both modalities were assessed using intraclass correlation coefficients (ICCs) and Bland-Altman analysis, respectively. RESULTS: Reliability (intra-rater I/II; inter-rater) of dental MRI measurements was excellent and comparable to CBCT for premolars (0.993/0.900; 0.958 vs. 0.993/0.956; 0.951) and for molars (0.978/0.995; 0.986 vs. 0.992/0.996; 0.989). Bland-Altman analysis revealed a mean underestimation/bias (95% confidence interval) of dMRI measurements of 0.8 (- 1.44/3.05) mm for premolars and 0.4 (- 1.55/2.39) mm for molars. In up to 59% of the cases, the accuracy of dMRI for WL measurements was within the underestimation margin of 0 to 2 mm short of the apical foramen AF. CONCLUSIONS: In vivo demonstration and measurement of WL are feasible using dMRI. The reliability of measurements is high and equivalent to CBCT. Nonetheless, due to lower spatial resolution and longer acquisition time, the accuracy of dMRI is inferior to CBCT, impeding its current use for clinical treatment planning. CLINICAL RELEVANCE: dMRI is a promising radiation-free imaging technique. Its reliability for endodontic working length measurements is high, but its accuracy is not satisfactory enough yet.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Diente Molar , Humanos , Adulto , Persona de Mediana Edad , Diente Premolar/diagnóstico por imagen , Proyectos Piloto , Reproducibilidad de los Resultados , Tomografía Computarizada de Haz Cónico/métodos , Diente Molar/diagnóstico por imagen , Imagen por Resonancia Magnética , Cavidad Pulpar/diagnóstico por imagen
7.
Invest Radiol ; 57(11): 720-727, 2022 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-35640007

RESUMEN

OBJECTIVES: The aims of this study were to quantify T1/T2-relaxation times of the dental pulp, develop a realistic tooth model, and compare image quality between cone-beam computed tomography (CBCT) and high-resolution magnetic resonance imaging (MRI) of single teeth using a wireless inductively coupled intraoral coil. METHODS: T1/T2-relaxometry was performed at 3 T in 10 healthy volunteers (283 teeth) to determine relaxation times of healthy dental pulp and develop a realistic tooth model using extracted human teeth. Eight MRI sequences (DESS, CISS, TrueFISP, FLASH, SPACE, TSE, MSVAT-SPACE, and UTE) were optimized for clinically applicable high-resolution imaging of the dental pulp. In model, image quality of all sequences was assessed quantitatively (contrast-to-noise ratio) and qualitatively (visibility of anatomical structures and extent of susceptibility artifacts using a 5-point scoring scale). Cone-beam computed tomography served as the reference modality for qualitative assessment. Statistical analysis was performed using 2-way analysis of variance, Fisher exact test, and Cohen κ. RESULTS: In vivo, relaxometry of dental pulps revealed T1/T2 relaxation times at 3 T of 738 ± 100/171 ± 36 milliseconds. For all sequences, an isotropic resolution of (0.21 mm) 3 was achieved, with acquisition times ranging from 6:19 to 8:02 minutes. In model, the highest contrast-to-noise ratio values were observed for UTE, followed by TSE and CISS. The best image/artifact quality, however, was found for DESS (mean ± SD: 1.3 ± 0.3/2.2 ± 0.0), FLASH (1.5 ± 0.3/2.4 ± 0.1), and CISS (1.5 ± 0.4/2.5 ± 0.1), at a level comparable to CBCT (1.2 ± 0.3/2.1 ± 0.1). CONCLUSIONS: Optimized MRI protocols using an intraoral coil at 3 T can achieve an image quality comparable to reference modality CBCT within clinically applicable acquisition times. Overall, DESS revealed the best results, followed by FLASH and CISS.


Asunto(s)
Tomografía Computarizada de Haz Cónico Espiral , Artefactos , Tomografía Computarizada de Haz Cónico/métodos , Humanos , Imagen por Resonancia Magnética/métodos
8.
Front Endocrinol (Lausanne) ; 13: 839774, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35620394

RESUMEN

Objective: The pathogenesis of diabetic polyneuropathy (DN) is poorly understood and given the increasing prevalence of DN, there is a need for clinical or imaging biomarkers that quantify structural and functional nerve damage. While clinical studies have found evidence of an association between elevated levels of troponin T (hsTNT) and N-terminal pro brain natriuretic peptide (proBNP) with microvascular compromise in type 2 diabetes (T2D), their implication in mirroring DN nerve perfusion changes remains unclear. The objective of this study was, therefore, to investigate whether hsTNT and proBNP assays are associated with MRI nerve perfusion in T2D. Methods: In this prospective cross-sectional single-center case-control study, 56 participants (44 with T2D, 12 healthy control subjects) consented to undergo magnetic resonance neurography (MRN) including dynamic contrast-enhanced (DCE) perfusion imaging of the right leg. Using the extended Tofts model, primary outcome parameters that were quantified are the sciatic nerve's microvascular permeability (Ktrans), the extravascular extracellular volume fraction (ve), and the plasma volume fraction (vp), as well as hsTNT and proBNP values from serological workup. Further secondary outcomes were clinical, serological, and electrophysiological findings. Results: In T2D patients, hsTNT was negatively correlated with Ktrans (r=-0.38; p=0.012) and ve (r=-0.30; p=0.048) but not with vp (r=-0.16; p=0.294). HsTNT, Ktrans, and ve were correlated with peroneal nerve conduction velocities (NCVs; r=-0.44; p=0.006, r=0.42; p=0.008, r=0.39; p=0.014), and tibial NCVs (r=-0.38;p=0.022, r=0.33; p=0.048, r=0.37; p=0.025). No such correlations were found for proBNP. Conclusions: This study is the first to find that hsTNT is correlated with a decrease of microvascular permeability and a reduced extravascular extracellular volume fraction of nerves in patients with T2D. The results indicate that hsTNT may serve as a potential marker for the assessment of nerve perfusion in future studies on DN.


Asunto(s)
Diabetes Mellitus Tipo 2 , Troponina T , Biomarcadores , Estudios de Casos y Controles , Estudios Transversales , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/diagnóstico por imagen , Diabetes Mellitus Tipo 2/patología , Humanos , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética , Perfusión , Nervios Periféricos/patología , Estudios Prospectivos
9.
Ann Clin Transl Neurol ; 9(6): 830-840, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35488789

RESUMEN

OBJECTIVES: Clinical and histological studies have found evidence that nerve ischemia is a major contributor to diabetic neuropathy (DN) in type 2 diabetes (T2D). The aim of this study was to investigate peripheral nerve microvascular permeability using dynamic contrast enhanced (DCE) magnetic resonance neurography (MRN) to analyze potential correlations with clinical, electrophysiological, and demographic data. METHODS: Sixty-five patients (35/30 with/without DN) and 10 controls matched for age and body mass index (BMI) underwent DCE MRN of the distal sciatic nerve with an axial T1-weighted sequence. Microvascular permeability (Ktrans ), plasma volume fraction (vp ), and extravascular extracellular volume fraction (ve ) were determined with the extended Tofts model, and subsequently correlated with clinical data. RESULTS: Ktrans and ve were lower in T2D patients with DN compared to patients without DN (0.037 min-1 ± 0.010 vs. 0.046 min-1 ± 0.014; p = 0.011, and 2.35% ± 3.87 vs. 5.11% ± 5.53; p = 0.003, respectively). In individuals with T2D, Ktrans correlated positively with tibial, peroneal, and sural NCVs (r = 0.42; 95%CI = 0.18 to 0.61, 0.50; 95%CI = 0.29 to 0.67, and 0.44; 95%CI = 0.19 to 0.63, respectively), with tibial and peroneal CMAPs (r = 0.27; 95%CI = 0.01 to 0.49 and r = 0.32; 95%CI = 0.07 to 0.53), and with the BMI (r = 0.47; 95%CI = 0.25 to 0.64). Negative correlations were found with the neuropathy deficit score (r = -0.40; 95%CI = -0.60 to -0.16) and age (r = -0.51; 95%CI = -0.67 to -0.31). No such correlations were found for vp . CONCLUSION: This study is the first to find associations of MR nerve perfusion parameters with clinical and electrophysiological parameters related to DN in T2D. The results indicate that a decrease in microvascular permeability but not plasma volume may result in nerve ischemia that subsequently causes demyelination.


Asunto(s)
Diabetes Mellitus Tipo 2 , Neuropatías Diabéticas , Permeabilidad Capilar/fisiología , Diabetes Mellitus Tipo 2/complicaciones , Neuropatías Diabéticas/patología , Humanos , Imagen por Resonancia Magnética/métodos , Nervio Ciático/patología
10.
Int Endod J ; 55(3): 252-262, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34767640

RESUMEN

AIM: This prospective in vivo study aimed to optimize the assessment of pulpal contrast-enhancement (PCE) on dental magnetic resonance imaging (dMRI) and investigate physiological PCE patterns. METHODOLOGY: In 70 study participants, 1585 healthy teeth were examined using 3-Tesla dMRI before and after contrast agent administration. For all teeth, the quotient of post- and pre-contrast pulp signal intensity (Q-PSI) was calculated to quantify PCE. First, pulp chambers were analysed in 10 participants to compare the coefficient of variation of mean versus maximum Q-PSI values (Q-PSImean versus Q-PSImax ). Second, dynamic PCE was evaluated in 10 subjects to optimize the time interval between contrast agent application and image acquisition. Finally, 50 participants (age groups: 20-29, 30-39, 40-49, 50-59 and 60-69 years) were examined to analyse age, gender, tooth types and maxilla versus mandible as independent factors of PCE. Statistical analysis was performed using Wilcoxon signed rank test and linear mixed models. RESULTS: PCE assessment based on Q-PSImax was associated with a significantly smaller coefficient of variation compared with Q-PSImean , with median values of 0.17 versus 0.21 (p = .002). Analysis of dynamic PCE revealed an optimal timing interval for image acquisition 4 min after contrast media application. No significant differences in PCE were observed by comparing age groups, female versus male participants and maxillary versus mandibular teeth (p > .05). Differences between tooth types were small (median Q-PSImax values of 2.52/2.32/2.30/2.20 for molars/premolars/canines/incisors) but significant (p < .05), except for the comparison of canines versus premolars (p = .80). CONCLUSIONS: PCE in dMRI was a stable intra-individual marker with only minor differences between different tooth types, thus forming an important basis for intra-individual controls when assessing teeth with suspected endodontic pathosis. Furthermore, it was demonstrated that PCE is independent of age, gender and jaw type. These findings indicate that dMRI-based PCE analysis could be a valuable diagnostic tool for the identification of various pulp diseases in future patient studies.


Asunto(s)
Pulpa Dental , Imagen por Resonancia Magnética , Adulto , Diente Premolar , Pulpa Dental/diagnóstico por imagen , Femenino , Humanos , Espectroscopía de Resonancia Magnética , Masculino , Maxilar , Estudios Prospectivos , Adulto Joven
11.
J Clin Med ; 10(23)2021 Nov 26.
Artículo en Inglés | MEDLINE | ID: mdl-34884244

RESUMEN

This study aimed to investigate the geometric reproducibility of three-dimensional (3D) implant planning based on magnetic resonance imaging (MRI) and cone-beam computed tomography (CBCT). Four raters used a backward-planning approach based on CBCT imaging and standard software to position 41 implants in 27 patients. Implant planning was repeated, and the first and second plans were analyzed for geometric differences regarding implant tip, entry-level, and axis. The procedure was then repeated for MRI data of the same patients. Thus, 656 implant plans were available for analysis of intra-rater reproducibility. For both imaging modalities, the second-round 3D implant plans were re-evaluated regarding inter-rater reproducibility. Differences between the modalities were analyzed using paired t-tests. Intra- and inter-rater reproducibility were higher for CBCT than for MRI. Regarding intra-rater deviations, mean values for MRI were 1.7 ± 1.1 mm/1.5 ± 1.1 mm/5.5 ± 4.2° at implant tip/entry-level/axis. For CBCT, corresponding values were 1.3 ± 0.8 mm/1 ± 0.6 mm/4.5 ± 3.1°. Inter-rater comparisons revealed mean values of 2.2 ± 1.3 mm/1.7 ± 1 mm/7.5 ± 4.9° for MRI, and 1.7 ± 1 mm/1.2 ± 0.7 mm/6 ± 3.7° for CBCT. CBCT-based implant planning was more reproducible than MRI. Nevertheless, more research is needed to increase planning reproducibility-for both modalities-thereby standardizing 3D implant planning.

12.
Clin Oral Implants Res ; 32(10): 1218-1227, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34352147

RESUMEN

OBJECTIVES: To measure in vivo 3D accuracy of backward-planned partially guided implant surgery (PGIS) based on dental magnetic resonance imaging (dMRI). MATERIAL AND METHODS: Thirty-four patients underwent dMRI examinations. Tooth-supported templates were backward planned using standard dental software, 3D-printed, and placed intraorally during a cone beam computed tomography (CBCT) scan. Treatment plans were verified for surgical viability in CBCT, and implants were placed with guiding of the pilot drill. High-precision impressions were taken after healing. The 3D accuracy of 41 implants was evaluated by comparing the virtually planned and definitive implant positions with respect to implant entry point, apex, and axis. Deviations from the dMRI-based implant plans were compared with the maximum deviations calculated for a typical single implant. RESULTS: Twenty-eight implants were placed as planned in dMRI. Evaluation of 3D accuracy revealed mean deviations (99% confidence intervals) of 1.7 ± 0.9mm (1.2-2.1mm) / 2.3 ± 1.1mm (1.8-2.9 mm) / 7.1 ± 4.8° (4.6-9.6°) for entry point / apex / axis. The maximum deviations calculated for the typical single implant surpassed the upper bounds of the 99% CIs for the apex and axis, but not for the entry point. In the 13 other implants, dMRI-based implant plans were optimized after CBCT. Here, deviations between the initial dMRI plan and definitive implant position were only in part higher than in the unaltered group (1.9 ± 1.7 mm [0.5-3.4 mm] / 2.5 ± 1.5 mm [1.2-3.8 mm] / 6.8 ± 3.8° [3.6-10.1°] for entry point / apex / axis). CONCLUSIONS: The 3D accuracy of dMRI-based PGIS was lower than that previously reported for CBCT-based PGIS. Nonetheless, the values seem promising to facilitate backward planning without ionizing radiation.


Asunto(s)
Implantes Dentales , Cirugía Asistida por Computador , Diente , Diseño Asistido por Computadora , Tomografía Computarizada de Haz Cónico , Implantación Dental Endoósea , Humanos , Imagenología Tridimensional , Imagen por Resonancia Magnética , Planificación de Atención al Paciente
13.
Front Neurosci ; 15: 642589, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33746707

RESUMEN

BACKGROUND: Nerve damage in diabetic neuropathy (DN) is assumed to begin in the distal legs with a subsequent progression to hands and arms at later stages. In contrast, recent studies have found that lower limb nerve lesions in DN predominate at the proximal sciatic nerve and that, in the upper limb, nerve functions can be impaired at early stages of DN. MATERIALS AND METHODS: In this prospective, single-center cross-sectional study, participants underwent diffusion-weighted 3 Tesla magnetic resonance neurography in order to calculate the sciatic nerve's fractional anisotropy (FA), a surrogate parameter for structural nerve integrity. Results were correlated with clinical and electrophysiological assessments of the lower limb and an examination of hand function derived from the Purdue Pegboard Test. RESULTS: Overall, 71 patients with diabetes, 11 patients with prediabetes and 25 age-matched control subjects took part in this study. In patients with diabetes, the sciatic nerve's FA showed positive correlations with tibial and peroneal nerve conduction velocities (r = 0.62; p < 0.001 and r = 0.56; p < 0.001, respectively), and tibial and peroneal nerve compound motor action potentials (r = 0.62; p < 0.001 and r = 0.63; p < 0.001, respectively). Moreover, the sciatic nerve's FA was correlated with the Pegboard Test results in patients with diabetes (r = 0.52; p < 0.001), prediabetes (r = 0.76; p < 0.001) and in controls (r = 0.79; p = 0.007). CONCLUSION: This study is the first to show that the sciatic nerve's FA is a surrogate marker for functional and electrophysiological parameters of both upper and lower limbs in patients with diabetes and prediabetes, suggesting that nerve damage in these patients is not restricted to the level of the symptomatic limbs but rather affects the entire peripheral nervous system.

14.
Front Neurosci ; 15: 741494, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-35140582

RESUMEN

BACKGROUND: Recent studies have found that troponin T parallels the structural and functional decay of peripheral nerves at the level of the lower limbs in patients with type 2 diabetes (T2D). The aim of this study was to determine whether this finding can also be reproduced at the level of the upper limbs. METHODS: Ten patients with fasting glucose levels >100 mg/dl (five with prediabetes and five with T2D) underwent magnetic resonance neurography of the right upper arm comprising T2-weighted and diffusion weighted sequences. The fractional anisotropy (FA), an indicator for the structural integrity of peripheral nerves, was calculated in an automated approach for the median, ulnar, and radial nerve. All participants underwent additional clinical, serological, and electrophysiological assessments. RESULTS: High sensitivity Troponin T (hsTNT) and HbA1c were negatively correlated with the average FA of the median, ulnar and radial nerve (r = -0.84; p = 0.002 and r = -0.68; p = 0.032). Both FA and hsTNT further showed correlations with items of the Michigan Hand Outcome Questionnaire (r = -0.76; p = 0.010 and r = 0.87; p = 0.001, respectively). A negative correlation was found for hsTNT and HbA1c with the total Purdue Pegboard Test Score (r = -0.87; p = 0.001 and r = -0.68; p = 0.031). CONCLUSION: This study is the first to find that hsTNT and HbA1c are associated with functional and structural parameters of the nerves at the level of the upper limbs in patients with impaired glucose tolerance and T2D. Our results support the hypothesis that hyperglycemia-related microangiopathy, represented by elevated hsTNT levels, is a contributor to nerve damage in diabetic polyneuropathy.

15.
Front Neurosci ; 15: 811085, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-35242003

RESUMEN

OBJECTIVE: It is controversially discussed in how far smoking contributes to diabetic polyneuropathy (DPN) in type 2 diabetes (T2D). Diffusion-weighted magnetic resonance neurography (MRN) at 3 Tesla has been shown to provide objective values for structural nerve integrity in patients with T2D. The aim of this study was to investigate the contribution of cigarette smoking on structural nerve integrity in T2D. METHODS: This cross-sectional prospective cohort study investigated the structural integrity of the sciatic nerve in 10 smokers, 40 never-smokers, and 20 ex-smokers with T2D and 10 healthy control subjects, using diffusion tensor imaging MRN at 3 Tesla and semi-automated nerve fiber tracking. Results were correlated with clinical, electrophysiological, and serological data. RESULTS: The sciatic nerve's fractional anisotropy (FA), a parameter for structural nerve integrity, was significantly lower in smokers with T2D when compared to controls (p = 0.002) and never-smokers (p = 0.015), and lower in ex-smokers when compared to controls (p = 0.015). In addition, sciatic nerve radial diffusivity, a marker of myelin damage, was increased in smokers versus controls and never-smokers (p = 0.048, p = 0.049, respectively). Furthermore, FA in T2D patients was negatively correlated with clinical and electrophysiological markers of DPN. FA also showed negative correlations with the pulse wave velocity, a marker of arterial stiffness and associated microangiopathy, in controls (r = -0.70; p = 0.037), never-smokers (r = -0.45; p = 0.004), ex-smokers (r = -0.55; p = 0.009), and a similar trend in smokers (r = -0.63; p = 0.076). Negative correlations were found between FA and skin auto-fluorescence, a marker of tissue advanced glycation end product accumulation and therefore long-term glycemic stress in T2D, in never-smokers (r = -0.39; p = 0.020) and smokers (r = -0.84; p = 0.004), but not in ex-smokers (r = -0.07; p = 0.765). CONCLUSION: The findings indicate that smoking contributes to sciatic nerve damage in T2D, potentially worsening DPN due to glycemic stress and less microangiopathy-associated myelin damage in active smokers, while angiopathic effects predominate in ex-smokers. To stop smoking may therefore pose a promising preventive measure to slow the progression of DPN in T2D.

16.
Clin Oral Investig ; 25(3): 1423-1431, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32785849

RESUMEN

OBJECTIVES: Magnetic resonance imaging (MRI) image quality can be severely impaired by artifacts caused by fixed orthodontic retainers. In clinical practice, there is a trend towards using computer-aided design/computer-aided manufacturing (CAD/CAM) retainers. This study aimed to quantify MRI artifacts produced by these novel CAD/CAM retainers. MATERIAL AND METHODS: Three CAD/CAM retainers and a stainless-steel retainer ("Twistflex"; clinical reference standard) were scanned in vitro at 3-T MRI using a high-resolution 3D sequence. The artifact diameters and three-dimensional artifact volumes (AV) were determined for all mandibular (AVmand) and maxillary (AVmax) retainers. Moreover, the corresponding ratio of artifact volume to retainer volume (AV/RVmand, AV/RVmax) was calculated. RESULTS: Twistflex caused large artifact volumes (AVmand: 13530 mm3; AVmax: 15642 mm3; AV/RVmand: 2602; AV/RVmax: 2235). By contrast, artifact volumes for CAD/CAM retainers were substantially smaller: whereas artifact volumes for cobalt-chromium retainers were moderate (381 mm3; 394 mm3; 39; 31), grade-5 titanium (110 mm3; 126 mm3; 12; 12) and nickel-titanium (54 mm3; 78 mm3; 12; 14) both produced very small artifact volumes. CONCLUSION: All CAD/CAM retainers caused substantially smaller volumes of MRI artifacts compared to Twistflex. Grade-5 titanium and nickel-titanium CAD/CAM retainers showed the smallest artifact volumes. CLINICAL RELEVANCE: CAD/CAM retainers made from titanium or nickel-titanium may not relevantly impair image quality in head/neck and dental MRI. Artifacts caused by cobalt-chromium CAD/CAM retainers may mask nearby dental/periodontal structures. In contrast, the large artifacts caused by Twistflex are likely to severely impair diagnosis of oral and adjacent pathologies.


Asunto(s)
Artefactos , Retenedores Ortodóncicos , Diseño Asistido por Computadora , Imagen por Resonancia Magnética , Acero Inoxidable , Titanio
17.
Front Neurosci ; 14: 570744, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33100960

RESUMEN

Diabetic neuropathy (DPN) is one of the most severe and yet most poorly understood complications of diabetes mellitus. In vivo imaging of dorsal root ganglia (DRG), a key structure for the understanding of DPN, has been restricted to animal studies. These have shown a correlation of decreased DRG volume with neuropathic symptom severity. Our objective was to investigate correlations of DRG morphology and signal characteristics at 3 Tesla (3T) magnetic resonance neurography (MRN) with clinical and serological data in diabetic patients with and without DPN. In this cross-sectional study, participants underwent 3T MRN of both L5 DRG using an isotropic 3D T2-weighted, fat-suppressed sequence with subsequent segmentation of DRG volume and analysis of normalized signal properties. Overall, 55 diabetes patients (66 ± 9 years; 32 men; 30 with DPN) took part in this study. DRG volume was smaller in patients with severe DPN when compared to patients with mild or moderate DPN (134.7 ± 21.86 vs 170.1 ± 49.22; p = 0.040). In DPN patients, DRG volume was negatively correlated with the neuropathy disability score (r = -0.43; 95%CI = -0.66 to -0.14; p = 0.02), a measure of neuropathy severity. DRG volume showed negative correlations with triglycerides (r = -0.40; 95%CI = -0.57 to -0.19; p = 0.006), and LDL cholesterol (r = -0.33; 95%CI = -0.51 to -0.11; p = 0.04). There was a strong positive correlation of normalized MR signal intensity (SI) with the neuropathy symptom score in the subgroup of patients with painful DPN (r = 0.80; 95%CI = 0.46 to 0.93; p = 0.005). DRG SI was positively correlated with HbA1c levels (r = 0.30; 95%CI = 0.09 to 0.50; p = 0.03) and the triglyceride/HDL ratio (r = 0.40; 95%CI = 0.19 to 0.57; p = 0.007). In this first in vivo study, we found DRG morphological degeneration and signal increase in correlation with neuropathy severity. This elucidates the potential importance of MR-based DRG assessments in studying structural and functional changes in DPN.

18.
J Clin Periodontol ; 47(12): 1485-1495, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32990988

RESUMEN

AIM: To compare non-contrast-enhanced dental magnetic resonance imaging (NCE-dMRI) and cone-beam computed tomography (CBCT) in assessing horizontal and vertical furcation defects in maxillary molars in vivo. MATERIALS AND METHODS: (NCE-dMRI) and CBCT were performed in 23 patients with severe periodontitis. Sixty-five first/second maxillary molars (195 furcation entrances) were analysed by two independent observers on both modalities to assess the horizontal and vertical components of furcation defects. Reliability of defect classification was evaluated using weighted kappa (κ) statistics. Agreement between NCE-dMRI and CBCT was determined by the Bland-Altman analysis. Sensitivity and specificity of NCE-dMRI were calculated using CBCT as the reference. RESULTS: Inter-radicular bone loss was observed in 94 furcation entrances. Intra- and inter-rater κ-values were ≥0.9 for both NCE-dMRI and CBCT. The Bland-Altman analysis showed mean differences (95% limits of agreement) of 0.12 mm (-0.67 to 0.90) for horizontal and 0.12 mm (-1.27 to 1.50) for vertical measurements. For the detection of furcation defects, sensitivity/specificity of NCE-dMRI was 98%/100% for horizontal and 99%/99% for vertical components. For defect classification, sensitivity values of NCE-dMRI were 88%/89%/100% (horizontal degree I/II/III) and 95%/91%/80% (vertical subclass A/B/C), respectively. CONCLUSIONS: Non-contrast-enhanced dental magnetic resonance imaging demonstrated high reliability and high agreement with CBCT for the assessment of furcation defects in maxillary molars.


Asunto(s)
Defectos de Furcación , Tomografía Computarizada de Haz Cónico , Estudios de Factibilidad , Defectos de Furcación/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Diente Molar/diagnóstico por imagen , Reproducibilidad de los Resultados
19.
Eur Radiol ; 30(12): 6392-6401, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32960331

RESUMEN

OBJECTIVES: To evaluate the accuracy and reliability of dental MRI for static guided implant surgery planning. MATERIALS AND METHODS: In this prospective study, a 0.4-mm isotropic, artifact-suppressed, 3T MRI protocol was used for implant planning and surgical guide production in participants in need of dental implants. Two dentists decided on treatment plan. Surgical guides were placed intraorally during a subsequent reference cone beam computed tomography (CBCT) scan. Inter-rater and inter-modality agreement were assessed by Cohen's kappa. For each participant, dental MRI and CBCT datasets were co-registered to determine three-dimensional and angular deviations between planned and surgically guided implant positions. RESULTS: Forty-five implants among 30 study participants were planned and evaluated (17 women, 13 men, mean age 56.9 ± 13.1 years). Inter-rater agreement (mean κ 0.814; range 0.704-0.927) and inter-modality agreement (mean κ 0.879; range 0.782-0.901) were both excellent for the dental MRI-based treatment plans. Mean three-dimensional deviations were 1.1 ± 0.7 (entry point) and 1.3 ± 0.7 mm (apex). Mean angular deviation was 2.4 ± 1.5°. CBCT-based adjustments of MRI plans were necessary for implant position in 29.5% and for implant axis in 6.8% of all implant sites. Changes were larger in the group with shortened dental arches compared with those for tooth gaps. Except for one implant site, all guides were suitable for clinical use. CONCLUSION: This feasibility study indicates that dental MRI is reliable and sufficiently accurate for surgical guide production. Nevertheless, more studies are needed to increase its accuracy before it can be used for implant planning outside clinical trials. KEY POINTS: • An excellent reliability for the dental MRI-based treatment plans as well as agreement between dental MRI-based and CBCT-based (reference standard) decisions were noted. • Ideal implant position was not reached in all cases by dental MRI plans. • For all but one implant site surgical guides derived from dental MRI were sufficiently accurate to perform implant placement (mean three-dimensional deviations were 1.1 ± 0.7 (entry point) and 1.3 ± 0.7 mm (apex); mean angular deviation was 2.4 ± 1.5°).


Asunto(s)
Protocolos Clínicos , Implantes Dentales , Maxilares/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Planificación de Atención al Paciente , Tomografía Computarizada de Haz Cónico , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados
20.
J Clin Periodontol ; 47(7): 809-815, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32343861

RESUMEN

AIM: To investigate the accuracy and reliability of dental magnetic resonance imaging (dMRI) in assessing maxillary molar furcation involvement (FI). MATERIAL AND METHODS: In this prospective study, 22 patients with severe periodontitis underwent cone-beam computed tomography (CBCT) and dMRI. For 192 furcation entrances, the degree of horizontal FI was assessed by two independent observers on both modalities. Results of dMRI were compared with CBCT (reference modality) to assess the accuracy of dMRI. Cohen's kappa (κ), sensitivity and specificity were calculated for FI classification. Bland-Altman analysis and the Kruskal-Wallis test were used to evaluate measurement accuracy of dMRI. RESULTS: Based on CBCT findings, 93 furcation entrances revealed FI (degree I/II/III: 35/19/39). Intra- and inter-reader agreement was excellent for both modalities (κ-range: 0.884 to 0.933). dMRI measurements showed high agreement with CBCT (bias: 0.17 mm; 95% limits of agreement: -1.05 to 1.38 mm), and measurement accuracy did not differ among different degrees of FI (p = .67). For FI detection, sensitivity and specificity of dMRI were 98% and 99%. For FI classification, sensitivity values of dMRI were 89%/84%/100% for degree I/II/III. CONCLUSIONS: Compared to CBCT (non-invasive gold standard), dMRI demonstrates high accuracy and reliability in evaluating the degree of FI in maxillary molars.


Asunto(s)
Defectos de Furcación , Tomografía Computarizada de Haz Cónico , Estudios de Factibilidad , Defectos de Furcación/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Diente Molar/diagnóstico por imagen , Estudios Prospectivos , Reproducibilidad de los Resultados