Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
2.
Artículo en Inglés | MEDLINE | ID: mdl-15687004

RESUMEN

We devised a sensitive and simple method for determination of bromide in whole blood and urine from humans using gas chromatography-mass spectrometry. Bromide was alkylated with pentafluorobenzyl p-toluenesulphonate in the mixture of acetone and phosphate buffer (pH 6.8). The derivative obtained was analyzed using gas chromatography-mass spectrometry with the positive-ion EI mode. The lower limit of detection for the compound was 1 mg/l. The calibration curve for bromide was linear over the concentration range from 2 to 100 mg/l. With use of this method, levels of bromide in whole blood and urine were determined in cases of poisoning by inhaled brominated hydrocarbons.


Asunto(s)
Bromuros/sangre , Bromuros/orina , Cromatografía de Gases y Espectrometría de Masas/métodos , Benzoatos/administración & dosificación , Benzoatos/química , Calibración , Humanos , Estándares de Referencia , Sensibilidad y Especificidad
3.
Leg Med (Tokyo) ; 6(3): 182-6, 2004 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-15231289

RESUMEN

An adult Japanese man (A) entered a pit to remove sludge in a drainage pipe at a dye works in Japan. When he took off a joint of the pipe, the sludge in the pipe flowed into the pit. As he suddenly lost consciousness, three colleagues (B, C, D) entered the pit to rescue him. All of these (A, B, C and D) lost consciousness in the pit, and died soon after the accident. Since hydrogen sulfide gas was detected in the sludge of the pit, gas poisoning was suspected. Toxicological analyses of sulfide and thiosulfate, a metabolite of sulfide, in blood and urine of the victims were made, using the extractive alkylation technique combined with gas chromatography/mass spectrometry. Sulfide and thiosulfate were detected in whole blood of the four workers at levels of 0.32-9.36 mg/l and 0.11-0.23 mmol/l, respectively. These concentrations were at least 6-187 times higher in sulfide and 37-77 times higher in thiosulfate than those in healthy persons, and were similar to values found in fatal cases of hydrogen sulfide poisoning. Thiosulfate was not detected in the urine of four workers, which indicated acute death. Based on these results, all four patients were victims of hydrogen sulfide poisoning, who died soon after the exposure.


Asunto(s)
Contaminantes Atmosféricos/envenenamiento , Sulfuro de Hidrógeno/envenenamiento , Residuos Industriales/efectos adversos , Exposición Profesional/efectos adversos , Adulto , Industria Química , Colorantes , Resultado Fatal , Cromatografía de Gases y Espectrometría de Masas , Humanos , Sulfuro de Hidrógeno/sangre , Sulfuro de Hidrógeno/orina , Masculino , Tiosulfatos/sangre , Tiosulfatos/orina
4.
Artículo en Inglés | MEDLINE | ID: mdl-15113546

RESUMEN

We devised a sensitive and simple method for simultaneous determination of formate and acetate in whole blood and urine from humans using gas chromatography-mass spectrometry. Formate and acetate were alkylated with pentafluorobenzyl bromide in the mixture of acetone and phosphate buffer (pH 6.8). The derivatives obtained were analyzed using gas chromatography-mass spectrometry in positive-ion electron ionization (EI) mode. The lower limit of detection for both compounds was 0.02mM. The calibration curves for formate and acetate were linear over the concentration range from 0.05 to 5.0mM. Accuracy and precision of the method were evaluated and the coefficients of variation were within 10%. With use of this method, levels of formate and acetate in whole blood can be determined in forensic cases.


Asunto(s)
Acetatos/sangre , Formiatos/sangre , Cromatografía de Gases y Espectrometría de Masas/métodos , Humanos , Estándares de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
5.
J Anal Toxicol ; 26(6): 320-4, 2002 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-12220012

RESUMEN

We devised a sensitive and simple method for the simultaneous determination of nitrate and nitrite in human plasma, using extractive alkylation. These inorganic anions were alkylated with pentafluorobenzyl bromide, using tetradecyldimethylbenzylammonium chloride as the phase-transfer catalyst, with 1,3,5-tribromobenzene as an internal standard. The derivatives were analyzed by gas chromatography-mass spectrometry, using the negative-ion chemical ionization mode with isobutane as the reagent gas. Calibration curves for nitrate and nitrite were linear over the concentration range of 0.01 to 1.0 micromol/mL in plasma, and the lower limit of detection for both compounds was 0.005 micromol/mL. The accuracy and precision of this method were evaluated and coefficients of variation were lower than 10.4%. Blood nitrate and nitrite concentrations of six victims who committed suicide by inhaling automobile exhaust gas could be determined using our method.


Asunto(s)
Intoxicación por Monóxido de Carbono/diagnóstico , Nitratos/sangre , Nitritos/sangre , Administración por Inhalación , Autopsia , Calibración , Cromatografía de Gases y Espectrometría de Masas , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Suicidio , Emisiones de Vehículos/efectos adversos
6.
J Forensic Sci ; 47(3): 652-5, 2002 May.
Artículo en Inglés | MEDLINE | ID: mdl-12051356

RESUMEN

An adult man (A) entered a pit to collect seepage at an industrial waste site in Japan. As he suddenly lost consciousness, three colleagues (B, C, D) entered the pit to rescue him. All of these men lost consciousness in the pit. Two workers (A and B) died soon after the accident, one worker (C) died 22 days after the accident, and one worker (D) survived. Since hydrogen sulfide gas was detected in the atmosphere of the pit, gas poisoning was suspected. Toxicological analyses of sulfide and thiosulfate, a metabolite of sulfide, in blood and urine of the victims were made using the extractive alkylation technique combined with gas chromatography/mass spectrometry (GC/MS). Sulfide was detected in the blood of A and B at levels of 0.13 and 0.11 mg/L, respectively, somewhat higher than in healthy persons. Thiosulfate was detected in whole blood of deceased victims A and B, in the plasma of deceased victim C, at concentrations of 10.53, 4.59, and 4.14 mg/L, respectively. These values were similar to those found in fatal cases of hydrogen sulfide poisoning. Thiosulfate was not detected in the plasma of survivor D. With respect to urine samples, thiosulfate was the highest in the non-acute death victim C (137.20 mg/L), followed by that in the survivor D (29.34 mg/L), and low (0.90 mg/L) and not detected in the acute death victims, A and B, respectively. Based on these results, all four patients were victims of hydrogen sulfide poisoning. The concentrations of thiosulfate in blood and urine were more useful than that for sulfide for determining hydrogen sulfide poisoning. Thiosulfate in urine was the only indicator of hydrogen sulfide poisoning in the non-fatal victim.


Asunto(s)
Sulfuro de Hidrógeno/envenenamiento , Residuos Industriales/efectos adversos , Exposición Profesional/efectos adversos , Tiosulfatos/sangre , Resultado Fatal , Humanos , Sulfuro de Hidrógeno/sangre , Sulfuro de Hidrógeno/orina , Japón , Masculino , Tiosulfatos/orina
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...