Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Med Ultrasound ; 29(2): 89-93, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34377638

RESUMEN

BACKGROUND: The purpose of this study was to determine the utility and diagnostic performance of strain elastography (SE) in differentiating benign from malignant lesions of the breast. METHODS: In this prospective study, 50 palpable breast masses in 50 patients were examined by mammography, B-mode ultrasound (US) and SE. Lesions were categorized using Breast Imaging Reporting and Data System (BIRADS) scoring based on mammographic and sonographic features. Elasticity scores were assessed on a five-point scale based on the distribution of strain, and the lesion size on SE imaging and B-mode (elasticity imaging/B mode [EI/B] ratio) was compared. Findings were correlated with the BIRADS assessment and diagnostic performance of sonoelastography was evaluated taking histopathology as reference standard. RESULTS: Histopathology revealed 29 (58%) malignant and 21 (42%) benign lesions. Infiltrative ductal carcinoma and fibroadenoma were the most common malignant and benign lesions, respectively. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of SE was 100%, 76.1%, 85.2%, 100%, and 90%, respectively. Higher elasticity score was significantly associated with malignant histopathology (P < 0.00001). The mean EI/B ratio for malignant lesions was 1.36 ± 0.24 while that of benign lesions was 1.03 ± 0.30 (P = 0.000). CONCLUSION: Real-time SE of the breast, with its superior sensitivity and specificity, could provide improved characterization of benign and malignant breast masses compared with mammography and conventional US. Due to greater diagnostic accuracy, SE can be an effective adjunctive tool to B-mode US in predicting malignancy of breast, as well as in reducing the need for biopsies in benign breast lesions.

2.
J Med Ultrasound ; 29(2): 111-115, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34377642

RESUMEN

BACKGROUND: Resistive index (RI), derived from color Doppler imaging (CDI), is a marker of vascular resistance used widely in varied clinical settings. The aim of this study was to analyze the association between RIs of the orbital vessels in a pure cohort of type 2 diabetic patients with or without retinopathy using CDI. METHODS: Fifty patients having type 2 diabetes and 50 age-matched controls were evaluated in this prospective study. Diabetic retinopathy (DR) was diagnosed based on seven-field stereo fundus photography and diabetic patients were divided into two. Patients with no DR (n = 26) were taken as Group 1, while patients with DR (n = 24) were taken as Group 2. CDI was performed and the RIs of the ophthalmic artery (OA), posterior ciliary artery (PCA), central retinal artery (CRA), and central retinal vein (CRV) were measured. RESULTS: Significant differences were observed in the mean RI values of all orbital arteries between controls and patients with DR (P < 0.05). Comparison of RI values between controls and Group 1 showed no significant differences. Mean RI values of the PCA and CRA were found to be significantly higher in the patients in Group 2 than in Group 1 (P = 0.03 and P < 0.001, respectively). The duration of diabetes correlated with the mean RI of all the orbital vessels. RI of the CRA was a reliable predictive indicator for DR (P = 0.001). CONCLUSION: RIs of the orbital arteries are significantly higher in patients with DR. RI of the orbital vessels can be a potentially useful biomarker in the early diagnosis and follow-up of patients with DR.

3.
J Med Ultrasound ; 28(3): 173-178, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33282662

RESUMEN

BACKGROUND: The purpose of this study was to evaluate the diagnostic value of transrectal real- time strain elastography (RTE) in identifying prostatic carcinoma (PCa). METHODS: 60 patients suspected of having PCa based on abnormal digital rectal examination and raised prostate specific antigen levels underwent transrectal ultrasound (TRUS), color Doppler (CD) and RTE. Elastograms were scored on a five point scale based on distribution of strain in relation to hypoechoic area on TRUS. Twelve core systematic biopsy as well as targeted biopsy was performed from suspicious areas on TRUS and RTE. Diagnostic performance of sonoelastography was evaluated using histopathology as reference standard. RESULTS: Histopathology revealed cancer in 28 out of 60 patients (47%) studied. Gleason score ranged from 6 to 9. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of TRUS in detecting prostate cancer were 78.57%, 81.25%, 78.57%, and 81.25%, respectively. On CD evaluation 87.5% (n = 28) of benign lesions showed symmetric, radial flow compared to 14.3% (n = 4) of malignant lesions (P < 0.0001). The sensitivity and specificity of RTE was 89.29% and 56.25% with PPV and NPV being 58.13% and 82.35%, respectively. Higher elastography score was found to be significantly associated with malignant histopathology (P = 0.004). Cancer detection rate with RTE was greater for tumors with higher Gleason score. CONCLUSION: RTE was found to have better sensitivity than TRUS as well as combination of TRUS and CD. Although less specific, RTE can be an effective adjuvant tool to TRUS for guidance of biopsy and improve detection rate of PCa.

4.
J Med Ultrasound ; 28(2): 92-98, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32874867

RESUMEN

BACKGROUND: The purpose of this study was to evaluate the usefulness of strain elastography and acoustic radiation force impulse (ARFI) imaging in the differentiation of benign and malignant cervical lymph nodes (LNs). MATERIALS AND METHODS: In this prospective study, 50 enlarged cervical LNs (33 benign and 17 malignant) were examined by B-mode ultrasound (US), color Doppler, and strain elastography. Elastographic patterns (1-5) were categorized based on distribution of hard area within LN. The shear wave velocity (SWV) of LNs was evaluated by ARFI imaging. Diagnostic performance of sonoelastographic parameters was compared taking histopathology of LN as a reference standard. Optimal cutoff value of the mean SWV values for predicting malignancy was determined using receiver operating characteristic curve analysis. RESULTS: Among US parameters, borders of LN had the highest diagnostic accuracy (80%), while echogenicity had the least (48%). Majority of benign LNs (n = 31) had elastography patterns 1 and 2, while majority of malignant LNs (n = 16) had patterns 3-5 (P = 0.000). The sensitivity, specificity, and accuracy of elastography were 94.1%, 93.9%, and 94%, respectively. The mean SWV of benign LNs (1.670 ± 0.367 m/s) differed significantly from malignant LNs (2.965 ± 0.826 m/s; P = 0.000). A cutoff value of 2.05 m/s predicted malignancy with 88.2% sensitivity and 84.8% specificity and gave an area under the curve of 0.949 (95% confidence interval: 0.70-1.20). CONCLUSION: Elastography has high diagnostic accuracy in differentiating benign and malignant cervical LNs and can be potentially useful in selecting the LN with high probability of malignancy, on which fine-needle aspiration cytology/biopsy can be performed.

5.
Indian J Ophthalmol ; 68(6): 1108-1114, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32461442

RESUMEN

Purpose: To investigate the retrobulbar circulatory parameters in type 2 diabetes mellitus patients with color Doppler imaging (CDI) and compare the results with nondiabetic controls. Methods: This prospective study included 50 type 2 diabetic patients and 50 age-matched controls. Seven field stereo fundus photography was used to diagnose and classify diabetic retinopathy (DR). Diabetic patients were further divided into two: Group 1, consisted of patients with no DR, mild and moderate non-proliferative DR (n = 36); Group 2, severe nonproliferative and proliferative DR (n = 14). CDI was performed using Philips iU22 xMATRIX ultrasound. The peak systolic velocity (PSV), end-diastolic velocity (EDV), resistivity index (RI) and pulsatile index (PI) of ophthalmic (OA), posterior ciliary artery (PCA), and central retinal artery (CRA) along with central retinal vein (CRV) were recorded. Results: RI in the ophthalmic artery was significantly higher in both DR groups than the control group (P = 0.000). Diabetic Group 1 had decreased blood flow velocity (PSV and EDV) in PCA compared to controls (P = 0.046 and P = 0.010, respectively). Group 2 DR had significantly reduced EDV and increased RI in CRA compared to Group 1 (P = 0.015). Binary logistic regression analysis revealed glycosylated hemoglobin and RI of OA to be independent risk factors of DR. Conclusion: Significant changes in resistivity index and flow velocities were observed in the retrobulbar vessels, especially in ophthalmic artery in diabetics compared to controls. CDI with results of increased resistance or decreased flow could be useful to predict individuals at higher risk for developing severe DR.


Asunto(s)
Diabetes Mellitus Tipo 2 , Arteria Retiniana , Arterias Ciliares/diagnóstico por imagen , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/diagnóstico , Humanos , Arteria Oftálmica/diagnóstico por imagen , Estudios Prospectivos , Flujo Sanguíneo Regional , Arteria Retiniana/diagnóstico por imagen , Ultrasonografía Doppler en Color
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...