Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Appl Radiat Isot ; 61(5): 793-7, 2004 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-15308146

RESUMEN

The gamma dose determination using thermoluminescent (TL) dosimeters in mixed neutron-gamma fields, such as in boron neutron capture therapy (BNCT), is difficult due to the thermal neutron sensitivity of the detectors; especially when equipment capable of glow curve analysis is not available. The two TL analysis methods used previously in Finnish BNCT to correct the measured TL signal to obtain absorbed gamma dose in vivo were studied and compared, and an enhanced method was introduced. The three TL methods were found surprisingly consistent despite, e.g. the rough estimate made in the first method.


Asunto(s)
Terapia por Captura de Neutrón de Boro , Dosimetría Termoluminiscente/métodos , Terapia por Captura de Neutrón de Boro/instrumentación , Terapia por Captura de Neutrón de Boro/estadística & datos numéricos , Finlandia , Rayos gamma/uso terapéutico , Humanos , Dosificación Radioterapéutica , Dosimetría Termoluminiscente/estadística & datos numéricos
2.
Phys Med Biol ; 48(17): 2895-906, 2003 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-14516107

RESUMEN

Polymer gels have been reported as a new, potential tool for dosimetry in mixed neutron-gamma radiation fields. In this work, BANG-3 (MGS Research Inc.) gel vials from three production batches were irradiated with 6 MV photons of a Varian Clinac 2100 C linear accelerator and with the epithermal neutron beam of the Finnish boron neutron capture therapy (BNCT) facility at the FiR 1 nuclear reactor. The gel is tissue equivalent in main elemental composition and density and its T2 relaxation time is dependent on the absorbed dose. The T2 relaxation time map of the irradiated gel vials was measured with a 1.5 T magnetic resonance (MR) scanner using spin echo sequence. The absorbed doses of neutron irradiation were calculated using DORT computer code, and the accuracy of the calculational model was verified by measuring gamma ray dose rate with thermoluminescent dosimeters and 55Mn(n,gamma) activation reaction rate with activation detectors. The response of the BANG-3 gel dosimeter for total absorbed dose in the neutron irradiation was linear, and the magnitude of the response relative to the response in the photon irradiation was observed to vary between different gel batches. The results support the potential of polymer gels in BNCT dosimetry, especially for the verification of two- or three-dimensional dose distributions.


Asunto(s)
Terapia por Captura de Neutrón de Boro/instrumentación , Geles , Polímeros , Radiometría/instrumentación , Radiometría/métodos , Planificación de la Radioterapia Asistida por Computador/instrumentación , Terapia por Captura de Neutrón de Boro/métodos , Relación Dosis-Respuesta en la Radiación , Análisis de Falla de Equipo , Neutrones/uso terapéutico , Dosis de Radiación , Radiometría/normas , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...