Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Cardiovasc Ultrasound ; 16(1): 24, 2018 Oct 02.
Artículo en Inglés | MEDLINE | ID: mdl-30285762

RESUMEN

BACKGROUND: Some patients with congestive heart failure have greater improvement of cardiac remodelling after cardiac resynchronisation therapy (CRT) and they are identified as super-responders (SRs). It remains unclear if echocardiographic markers of dyssynchrony could accuratelly predict super-response to CRT. The aim of this study is to evaluate potential echocardiographic predictors associated with super-response to CRT. METHODS: Fifthy nine CRT patients (mean age 52.9 ± 9.0 years, 88% men) with congestive heart failure (54% ischaemic and 46% non-ischaemic aetiology) II-IV NYHA functional class were enrolled. To assess mechanical dyssynchrony we evaluated interventricular mechanical delay, the maximum delay between peak systolic velocities of the septal and posterior walls of left ventricle, duration of left ventricular pre-ejection period (LVPEP), left ventricular and interventricular dyssynchrony by tissue Doppler imaging and systolic dyssynchrony index by 3D echocardiography. After six months the patients were assessed for response and classified as SRs (reduction in left ventricular end-systolic volume (LVESV) ≥30%, n = 20) and non-SRs (reduction in LVESV < 30%, n = 39) and baseline data were analyzed to identify the predictors. RESULTS: Both groups demonstrated significant improvement in NYHA functional class, increase in left ventricular ejection fraction and reduction in LVESV. All parameters of mechanical dyssynchrony at baseline were significantly higher in SR group. Multiple logistic regression analysis showed that LVPEP (HR 1.031; 95% CI 1.007-1.055; p = 0.011) was an independent predictor for CRT super-response. In ROC curve analysis LVPEP with a cut-off value of 147 ms demonstrated 73.7% sensitivity and 75% specificity (AUC = 0.753; p = 0.002) for the prediction of super-response to CRT. CONCLUSION: Greater mechanical dyssynchrony is associated with super-response to CRT in patients with congestive heart failure. It is probable that an LVPEP > 147 ms can be used as independent predictor of super-response.


Asunto(s)
Desfibriladores Implantables , Ecocardiografía Tridimensional/métodos , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/terapia , Disfunción Ventricular Izquierda/diagnóstico por imagen , Anciano , Terapia de Resincronización Cardíaca/métodos , Estudios de Cohortes , Bases de Datos Factuales , Ecocardiografía/métodos , Femenino , Estudios de Seguimiento , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Proyectos Piloto , Valor Predictivo de las Pruebas , Pronóstico , Curva ROC , Índice de Severidad de la Enfermedad , Volumen Sistólico/fisiología , Factores de Tiempo , Resultado del Tratamiento , Disfunción Ventricular Izquierda/fisiopatología
2.
Occup Med (Lond) ; 67(3): 233-235, 2017 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-28339702

RESUMEN

We present a case of a 32-year-old male crew member of a cargo ship, accidentally exposed to phosphine, a fumigating substance. He and other crew members developed increasing fatigue and digestive disorders 24 h later; two died from acute pulmonary oedema. The patient was admitted to hospital, where bilateral pneumonia, acute nephritis, hepatopathy, electrolyte imbalance and leucopenia were diagnosed. He was discharged from hospital 3 weeks later. He was examined 4 months later for possible chronic consequences of acute phosphine poisoning, which included echocardiography showing normal heart size and cardiac function. However, on advanced quantitative analysis, using two-dimensional speckle tracking echocardiography, depressed global longitudinal strain was found. Our report extends previously published findings of phosphine-induced left ventricular (LV) dysfunction by demonstrating that subclinical myocardial dysfunction resulting from acute phosphine exposure may persist several months after the exposure in an otherwise asymptomatic patient, and potentially may not be entirely reversible. The persistence of subclinical abnormalities of LV longitudinal function can be diagnosed using the advanced quantitative echocardiographic analysis we describe.

4.
Int J Cardiol ; 173(1): 55-64, 2014 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-24636551

RESUMEN

BACKGROUND: Previously, connexin 43-modified skeletal myoblasts (MbCx) were shown to reduce the pro-arrhythmic effect during the regeneration of heart tissue in an animal model of infarction. To increase the relevance to clinical implementation, in this study, we introduced connexin 43 into human myoblasts using a highly safe non-viral vector and demonstrated that their transplantation had a positive effect on the function of the injured heart. METHODS AND RESULTS: Myoblasts were efficiently transfected with a pCiNeo-GJA1 plasmid (65.72%). qPCR analysis revealed over 32-fold higher expression of the connexin 43 gene in the MbCx cell population compared to 'native' controls. The susceptibility of the myoblasts to oxidative stress conditions (p<0.001) and the fusion index (p<0.01) were increased in the MbCx cells. Additionally, we observed changes in the MYOG and MYH2 gene expression levels in the GJA1-modified myoblasts. Finally, we observed a significant improvement in the post-infarction echocardiographic parameters after intervention using MbCx cells compared with non-transfected myoblasts (MbWt) and the control (0.9% NaCl), wherein a significant decrease in the left ventricular area change in the short axis (SAX AC%) was observed at the two-month follow-up (p<0.05 and p<0.01, respectively). CONCLUSIONS: We demonstrated the positive effect of connexin 43 overexpression on the biology and function of human skeletal myoblasts in the context of their potential clinical applications. Our preclinical studies using a mouse infarction model indicated the positive effect of MbCx implantation on the function of the injured heart.


Asunto(s)
Conexina 43/biosíntesis , Insuficiencia Cardíaca/metabolismo , Insuficiencia Cardíaca/terapia , Mioblastos Esqueléticos/metabolismo , Mioblastos Esqueléticos/trasplante , Trasplante de Células Madre/métodos , Animales , Células Cultivadas , Insuficiencia Cardíaca/patología , Humanos , Ratones , Ratones Endogámicos NOD , Ratones SCID , Infarto del Miocardio/metabolismo , Infarto del Miocardio/patología , Infarto del Miocardio/terapia , Estudios Prospectivos
5.
Adv Med Sci ; 58(1): 67-72, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23612676

RESUMEN

PURPOSE: The diagnostic value of examinations performed with the use of pocket-size echocardiograph by medical professionals with different levels of experience remains to be determined. The aim of this study was to assess the diagnostic value of bedside echocardiographic examinations performed with the use of pocket-size echocardiograph by experienced cardiologist and medical students. MATERIAL/METHODS: The study group comprised 90 patients (63 men, 27 women; mean age 64±14 years) admitted to the cardiac intensive care unit and 30 patients from an out-patient clinic (21 men, 9 women; mean age 62±17 years). All patients underwent bedside echocardiographic examination performed with pocket-size echocardiograph by two briefly trained medical students (n=90 patients) or cardiologist (n=30 patients). Major findings were recorded using a simplified questionnaire. Within 24 hours standard echocardiographic examination was performed in all patients by another cardiologist using a full sized echocardiograph. The study group was divided into 4 subgroups: A / B - first / second half of in-patients examined by students, group C - inpatients examined by cardiologist, group D- out-patients examined by students. RESULTS: The agreement between standard transthoracic echocardiography (sTTE) and major findings on bedside transthoracic echocardiography (bTTE) was fair to moderate (kappa 0.293-0.57) in group A, moderate to very good (kappa 0.535-1.00) in group B, good to very good (kappa 0.734-1.00) in group C and moderate to very good (kappa 0.590-1.00) in group D. CONCLUSIONS: Pocket-size echocardiograph enables an expert echocardiographer to perform reliable bedside examinations. When used by briefly trained medical students it provides an acceptable diagnostic value with notable learning curve effect.


Asunto(s)
Ecocardiografía/instrumentación , Diseño de Equipo/métodos , Miniaturización/instrumentación , Anciano , Cuidados Críticos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pacientes Ambulatorios , Sistemas de Atención de Punto , Reproducibilidad de los Resultados , Estudiantes de Medicina
6.
Eur J Phys Rehabil Med ; 49(6): 785-91, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23558697

RESUMEN

BACKGROUND: There are no reliable data concerning the safety and benefits of physical rehabilitation in patients with a two-vessel disease before the second stage of angioplasty. The aim of this study was to evaluate the efficiency of early cardiac rehabilitation in patients with acute coronary syndromes and with angiographically significant residual coronary artery stenosis after a successful percutaneous coronary intervention (PCI) into the culprit lesion. DESIGN: Retrospective analysis of the results of coronary angiograms and exercise tests of patients who underwent stationary rehabilitation after their first ACS and first PCI. SETTING: Cardiac Rehabilitation Department. POPULATION: One hundred ninety patients divided into 2 groups according to the completeness of myocardial revascularization; 49 with significant (≥70%) coronary artery stenosis in a non-culprit vessel, the mean diameter reduction 80±9%; and 141 without any residual stenosis. The prevalence of classical risk factors was comparable in both groups. Rehabilitation was conducted as a stationary 3-week program. METHODS: Comparison of the initial and final exercise test workload in both groups, as well as the frequency of adverse effects during the program. RESULTS: Physical training in patients with incomplete revascularization (IR) was safe and well tolerated. Significant increase of workload capacity after the rehabilitation program was observed in both groups: in the IR group from 7.3±3.0 to 8.8±2.9 MET (P<0.0001) and in the complete revascularization (CR) group - from 7.6±2.8 to 9.2±2.9 MET (P<0.0001). No significant difference was observed in initial workload capacities (P=0.9813) nor in final workload capacities (P=0.8571) between the two groups. Two patients in the group with residual lesion (4%) and one in the group without residual lesion (0.7%) required urgent PCI during the rehabilitation program, P=0.1637. CONCLUSION: Early postinfarction physical training is safe and efficient for patients after complete revascularization and for those with untreated non-culprit coronary artery stenosis. Gradual increase in physical training intensity under cardiologist supervision is essential in identifying those rare patients for whom the second stage of angioplasty should not be delayed. CLINICAL REHABILITATION IMPACT: Our study shows that patients with incomplete revascularization may be qualified for cardiac rehabilitation programs.


Asunto(s)
Síndrome Coronario Agudo/rehabilitación , Puente de Arteria Coronaria , Estenosis Coronaria/rehabilitación , Seguridad del Paciente , Intervención Coronaria Percutánea , Síndrome Coronario Agudo/terapia , Angioplastia Coronaria con Balón , Angiografía Coronaria , Estenosis Coronaria/terapia , Prueba de Esfuerzo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Polonia , Estudios Retrospectivos
9.
Pol Merkur Lekarski ; 20(120): 635-8, 2006 Jun.
Artículo en Polaco | MEDLINE | ID: mdl-17007256

RESUMEN

UNLABELLED: Pharmacological stress echocardiography (SE) has become a routine diagnostic and prognostic method in patients with ischemic heart disease. However, all stress tests can provoke undesirable adverse effects including dangerous arrhythmia. The aim of the study was to access the prevalence and types of arrhythmia that can appear during SE. MATERIALS AND METHODS: A retrospective study included the cohort of patients studied using SE in our Department of Cardiology between 1995 and 2002. We followed the data of 836 patients (pts) (615 men, aged 52 +/- 5 yrs). Dobutamine SE was performed in 695 pts (83.2%) and dipyridamole SE in a group of 141 pts (16.8%). Additionally, atropine was administrated to achieve submaximal heart rate in a group of 694 pts (83%). 519 pts (62%) underwent SE was performed according to high dose protocol and in 317 pts (35%)--low dose protocol. RESULTS: During SE the following arrhythmia events were observed: one persistent ventricular tachycardia (0.12%) and two paroxysmal atrial fibrillation (0.24%) in dobutamine test. The set of unsustained ventricular tachycardia in six patients (0.72%) 5 patients from dobutamine group and 1 from dipyridamole group). Complex forms of ventricular extrasystoles (as bigeminy and trigeminy) in 46 pts (5.5%) 43 in dobutamine SE and 3 in dipyridamole SE. All arrhythmias were mild and withdrew spontaneously or after beta-blockers administration. CONCLUSIONS: The risk of dangerous arrhythmia during either dobutamine SE or dipyridamole SE is small and similar in both groups. Dobutamine SE tends to provoke of mild arrhythmia (p = 0.075) more often.


Asunto(s)
Arritmias Cardíacas , Cardiotónicos/efectos adversos , Dipiridamol/efectos adversos , Dobutamina/efectos adversos , Ecocardiografía de Estrés/efectos adversos , Vasodilatadores/efectos adversos , Arritmias Cardíacas/tratamiento farmacológico , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/etiología , Atropina/uso terapéutico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Simpatomiméticos/uso terapéutico
10.
J Thromb Haemost ; 4(6): 1361-6, 2006 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16706983

RESUMEN

BACKGROUND: Preliminary data suggest that plasma concentration of plasminogen activators inhibitor type 1 (PAI-1) is genetically determined and may be related to differential regulation of plasma PAI-1 concentration at baseline and after stimulation. AIM: This study aimed to evaluate whether increase in the plasma PAI-1 antigen concentration or activity after fibrinolytic therapy in patients with acute myocardial infarction is associated with the -675 4G/5G genetic polymorphism in the promoter region of PAI-1 gene. RESULTS & CONCLUSIONS: Our study revealed that a rebound effect is observed in PAI-1 activity (ActPAI-1) and PAI-1 antigen (AgPAI-1) concentration after standard streptokinase treatment with maximal values of 3 h (t3) after the completion of streptokinase infusion. Both ActPAI-1 and AgPAI-1 were significantly higher at t3 compared to the levels before fibrinolytic treatment: 37.3 (20.0-67.7) vs. 10.0 (3.6-26.0) IU L(-1); P = 0.00001 and 29.9 (15.6-42.3) vs. 20.9 (13.0-30.2) ng mL(-1); P = 0.001, respectively. The stratification of the patients by genotype revealed that carriers of the 4G allele had higher concentrations of PAI-1 antigen 3 h after streptokinase infusion: 30.9 vs. 13.8 ng mL(-1); P = 0.019. No significant association between PAI-1 activity and genotype was found. In conclusion, the rebound effect in serum PAI-1 concentration observed after streptokinase treatment may be related to the 4G/5G polymorphism in the PAI-1 gene promoter.


Asunto(s)
Fibrinolíticos/uso terapéutico , Infarto del Miocardio/tratamiento farmacológico , Inhibidor 1 de Activador Plasminogénico/genética , Polimorfismo Genético , Estreptoquinasa/uso terapéutico , Terapia Trombolítica , Anciano , Femenino , Genotipo , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/sangre , Infarto del Miocardio/genética , Inhibidor 1 de Activador Plasminogénico/sangre , Regiones Promotoras Genéticas/genética
11.
Heart ; 89(4): 422-6, 2003 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-12639871

RESUMEN

OBJECTIVE: To assess arterial distensibility using pulse wave velocity (PWV) measurements and its relation with endothelium dependent vasodilatation (EDV) in patients with cardiological syndrome X. METHODS: The study group consisted of 92 patients: 52 with syndrome X (34 women, 18 men, mean (SD) age 45 (3) years) and 40 healthy volunteer controls (27 women, 13 men, mean (SD) age 41 (2) years) without risk factors of atherosclerosis and with negative ECG exercise test and normal proximal coronaries on transoesophageal echocardiography. Patients with arterial hypertension, diabetes mellitus, valvar disease, or cardiomyopathy were excluded. PWV measured by a Complior Colson device was calculated for each patient. EDV was assessed from two dimensional Doppler measurement using an Acuson Sequoia with 8 MHz linear transducer at rest, during postischaemic reactive hyperaemia, and after an oral dose of 400 micro g of glyceryl trinitrate. RESULTS: PWV was significantly higher in patients with syndrome X than in healthy subjects (9.3 (0.7) m/s v 8.2 (0.9) m/s, respectively, p < 0.001). Baseline brachial artery diameter was similar in the syndrome X and control groups (4.0 (0.6) mm v 4.08 (0.64) mm, NS). EDV was impaired in patients with syndrome X compared with controls (6.6 (3.0)% v 11.1 (3.9)%, p < 0.001). Endothelium independent vasodilatation was similar in both groups. In patients with syndrome X there was a positive correlation between PWV and the degree of EDV (r = 0.864, p < 0.001). The cut off value for PWV was 8.5 m/s, with a sensitivity of 62% and a specificity of 91%. CONCLUSIONS: EDV but not glyceryl trinitrate induced vasodilatation is decreased in patients with syndrome X. There is a strong correlation between PWV and the degree of endothelial dysfunction of peripheral arteries in patients with syndrome X. PWV assessment may be useful to identify abnormal vascular physiology in these patients.


Asunto(s)
Arteria Braquial/fisiopatología , Angina Microvascular/fisiopatología , Pulso Arterial , Adulto , Velocidad del Flujo Sanguíneo/fisiología , Estudios de Casos y Controles , Angiografía Coronaria , Ecocardiografía , Endotelio Vascular/fisiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Vasodilatación/fisiología
12.
Pacing Clin Electrophysiol ; 24(3): 391-3, 2001 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-11310313

RESUMEN

Formation of thrombi on a permanent pacemaker lead is a rare complication of pacing. However, because of its serious outcome it should be suspected in a patient who reveals right-sided heart failure, dyspnea, or syncope. An early decision to perform an echocardiographic examination, followed by surgical or thrombolytic treatment can solve this clinical problem. In a 69-year-old woman with increasing signs of congestive heart failure, echocardiography revealed a mobile mass in the right atrium attached to the pacemaker lead. Because of threatened symptoms and large dimensions of the mass, urgent surgical removal of the endocardial lead was successfully performed.


Asunto(s)
Ecocardiografía Doppler , Marcapaso Artificial/efectos adversos , Trombosis/diagnóstico por imagen , Trombosis/cirugía , Anciano , Falla de Equipo , Femenino , Humanos
13.
Am J Cardiol ; 87(3): 278-82, 2001 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-11165960

RESUMEN

Microvascular integrity, as seen by myocardial contrast echocardiography (MCE), assesses whether myocardium has been successfully reperfused after an acute myocardial infarction. Until now this has been demonstrated only with intracoronary injection of an ultrasound contrast agent. Power Doppler imaging is a recently developed myocardial contrast echocardiographic method that counts the contrast microbubbles destroyed by ultrasounds and displays this number in color. This study sought to evaluate whether power Doppler MCE is able to visualize myocardial reperfusion during intravenous contrast injection. Thirty patients were evaluated 2 days after their first myocardial infarction during intravenous infusion of perfluorocarbon-exposed sonicated dextrose albumin (PESDA). Coronary artery angiography and single-photon emission computed tomography (SPECT) were used as reference techniques. A 16-segment left ventricular model was used to relate perfusion to coronary artery territories. Sensitivity and specificity of power Doppler MCE for segments supplied by infarct-related arteries were 82% and 95%, respectively. Accuracy of power Doppler MCE and SPECT were similar (90% vs 92% on segmental basis and 98% vs 98% on coronary artery territory basis). Two-dimensional echocardiography was repeated after 6 weeks. Segments recovering wall motion after 6 weeks were defined as stunning myocardium. Dysfunctional but perfused myocardium at day 2 after the infarction showed a better late recovery of wall motion compared with dysfunctional but nonperfused myocardium (p <0.001). In conclusion, harmonic power Doppler imaging is a sensitive and specific method for the identification of myocardial reperfusion early after myocardial infarction. It yields prognostic information for late recovery of ventricular function differentiating stunning (dysfunctional but perfused) from necrotic myocardium (dysfunctional and nonperfused).


Asunto(s)
Medios de Contraste , Ecocardiografía Doppler en Color , Aumento de la Imagen , Infarto del Miocardio/diagnóstico por imagen , Daño por Reperfusión Miocárdica/diagnóstico por imagen , Ultrasonografía Intervencional , Adulto , Anciano , Angiografía Coronaria , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/tratamiento farmacológico , Sensibilidad y Especificidad , Terapia Trombolítica , Tomografía Computarizada de Emisión de Fotón Único
14.
Eur Heart J ; 21(20): 1666-73, 2000 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-11032693

RESUMEN

BACKGROUND: Patients with left bundle branch block exhibit abnormal septal motion which may limit the interpretation of stress echocardiograms. This study sought to assess the diagnostic value of dobutamine-atropine stress echocardiography in left bundle branch block patients. METHODS AND RESULTS: Sixty-four left bundle branch block patients (mean age 59 years, 24 men) with suspected coronary artery disease underwent dobutamine-atropine stress echocardiography and coronary arteriography. Myocardial ischaemia was defined as new or worsening wall thickening abnormalities. Coronary artery disease was quantitatively defined as a diameter stenosis >/=50% in a major epicardial artery. Rest septal motion was normal (apart from the early systolic septal notch) in 34 patients (53%) and abnormal in 30 patients (47%). Rest septal thickening was normal in 32 patients (50%) and abnormal in 32 patients (50%). All seven patients with a QRS duration >/=160 ms and an abnormal QRS axis had abnormal rest septal motion and thickening. Inter-observer agreement for ischaemia was 88%. In all but one patient disagreement was in the septum. For the anterior and posterior circulation, respectively, sensitivity was 60% (9/15) and 67% (8/12), specificity was 94% (46/49) and 98% (51/52), and accuracy was 86% (55/64) and 92% (59/64). Sensitivity for the anterior circulation tended to be better in patients with normal rest septal thickening (83% vs 44%). CONCLUSIONS: Dobutamine-atropine stress echocardiography has excellent diagnostic specificity in left bundle branch block patients with suspected coronary artery disease. In patients with abnormal rest septal thickening, however, dobutamine-atropine stress echocardiography may lack good sensitivity for detection of coronary artery disease in the anterior circulation. Left bundle branch block patients who potentially most benefit from dobutamine-atropine stress echocardiography may initially be selected by their resting electrocardiogram.


Asunto(s)
Bloqueo de Rama/complicaciones , Enfermedad Coronaria/complicaciones , Enfermedad Coronaria/diagnóstico por imagen , Ecocardiografía/normas , Prueba de Esfuerzo/normas , Adulto , Anciano , Atropina/efectos adversos , Cardiotónicos/efectos adversos , Dobutamina/efectos adversos , Electrocardiografía , Reacciones Falso Negativas , Reacciones Falso Positivas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/diagnóstico por imagen , Variaciones Dependientes del Observador
15.
Echocardiography ; 17(2): 141-50, 2000 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-10978972

RESUMEN

Transesophageal echocardiography (TEE) enables the visualization of proximal coronary arteries. We investigated the feasibility of coronary flow evaluation using TEE, as well as to define flow parameters found in normal proximal coronary arteries. The subgroups of patients with normal proximal segments of coronary arteries were selected from the cohort of 210 patients undergoing routine coronary angiography. The left main coronary artery (LMCA), proximal segment of left anterior descending coronary artery (LAD), left circumflex artery (LCx), and right coronary artery (RCA) were analyzed separately in 147, 64, 53, and 70 patients, respectively. Proximal coronary arteries were evaluated in the transverse plane using a 5-MHz TEE probe, and the flow in normal arteries was registered using pulsed-wave Doppler. The registration of flow with pulsed-wave Doppler was feasible in 88% of studies for the LMCA, 85% for the LAD, 58% for the LCx, and 65% for the RCA. Normal flow was laminar with distinct phasic character (diastolic predominance). Mean +/- SD values of peak coronary flow velocity were (systole/diastole) for the LMCA, 36 +/- 11/71 +/- 19 cm/sec; the LAD, 31 +/- 9/67 +/- 19 cm/sec; the LCx, 36 +/- 13/75 +/- 24 cm/sec; and the RCA, 25 +/- 8/39 +/- 12 cm/sec. Peak diastolic coronary flow velocity was most significantly correlated with heart rate. Doppler evaluation of proximal coronary flow is feasible using TEE in the majority of patients. The knowledge of normal flow values, which is different for the left and the right coronary artery, provides the background for proper interpretation of flow in diseased coronary arteries.


Asunto(s)
Circulación Coronaria/fisiología , Enfermedad Coronaria/fisiopatología , Vasos Coronarios/diagnóstico por imagen , Ecocardiografía Doppler de Pulso/métodos , Ecocardiografía Transesofágica , Adolescente , Adulto , Anciano , Velocidad del Flujo Sanguíneo/fisiología , Estudios de Cohortes , Angiografía Coronaria , Enfermedad Coronaria/diagnóstico por imagen , Vasos Coronarios/fisiología , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Contracción Miocárdica
16.
J Am Soc Echocardiogr ; 13(8): 715-22, 2000 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-10936814

RESUMEN

BACKGROUND: Prolonged 3-dimensional echocardiography (3DE) acquisition time currently limits its routine use for calculating left ventricular volume (LVV) and ejection fraction (EF). Our goal was to reduce the acquisition time by defining the largest rotational acquisition interval that still allows 3DE reconstruction for accurate and reproducible LVV and EF calculation. METHODS: Twenty-one subjects underwent magnetic resonance imaging and precordial 3DE with 2 degrees acquisition intervals. Images were processed to result in data sets containing images at 2 degrees, 4 degrees, 8 degrees, 16 degrees, 32 degrees, and 64 degrees intervals by excluding images in between. With use of the paraplane feature, 8 equidistant short-axis slices were generated from each data set. The suitability of these short-axis slices for manual endocardial tracing was scored visually by 4 independent experienced observers. The LVV and EF were calculated by using Simpson's rule from 3DE data sets with 2 degrees, 8 degrees, and 16 degrees intervals, and the results were compared with values obtained from magnetic resonance imaging. The probability of 3DE to detect LVV and EF differences was calculated. RESULTS: All patients were in sinus rhythm with a mean heart rate of 72 bpm (SD + or - 12). The LV short-axis images obtained with 16 degrees rotational scanning intervals allowed LV endocardial tracing in all subjects. Good correlation, close limits of agreement, and nonsignificant differences were found between values of LVV and EF calculated with 3DE at 2 degrees, 8 degrees, and 16 degrees rotational intervals and those obtained with magnetic resonance imaging. At steps of 16 degrees, 3DE had excellent correlation (r = 98, 99, and 99), close limits of agreement (+ or - 38, + or - 28.6, and + or - 4.8), and nonsignificant differences (P =.5,.8, and.2) with values obtained from magnetic resonance imaging for calculating end-diastolic LVV, end-systolic LVV, and EF, respectively. Three-dimensional echocardiography with use of 16 degrees rotational intervals could detect 15-mL differences in end-diastolic volume with a probability of 95%, 11-mL differences in end-systolic volume with a probability of 92%, and 0.02 differences in EF with a probability of 95%. CONCLUSIONS: The 3DE data sets reconstructed with images selected at 16 degrees intervals from data sets obtained at 2 degrees precordial rotational acquisition intervals allowed the generation of LV short-axis images with adequate quality for endocardial border tracing. Therefore precordial acquisition at 16 degrees intervals would be sufficient for the reconstruction of 3DE data sets for LV function measurement. This would reduce the acquisition time while maintaining enough accuracy for clinical decision making and would thus make 3DE more practical as a routine method.


Asunto(s)
Ecocardiografía Tridimensional/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Función Ventricular Izquierda , Adulto , Anciano , Cardiomiopatía Dilatada/diagnóstico , Femenino , Ventrículos Cardíacos/patología , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Contracción Miocárdica , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Volumen Sistólico
17.
Ultrasound Med Biol ; 26(5): 863-9, 2000 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-10942833

RESUMEN

Most three-dimensional (3-D) echocardiography (3-DE) systems today are based on off-line methods where a large number of cross-sectional 2-D scans have to be acquired sequentially before a 3-D image can be reconstructed. Because acquisition is done step-by-step based on ECG triggering plus respiratory gating, this introduces motion artefacts and takes significant acquisition time. Another 3-D approach is based on 2-D transducers and parallel beam-forming. Such a system is very complex. In this manuscript, a fast continuously-rotating scanning unit, based on a 64-element phased-array transducer, is described. Typical rotation speed of the 3-D unit is 8 rotations per s. Therefore, 16 3-D volume datasets can be acquired per s in real-time. The first clinical examples as acquired with this probe are presented.


Asunto(s)
Ecocardiografía , Ventrículos Cardíacos/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Artefactos , Velocidad del Flujo Sanguíneo/fisiología , Ecocardiografía/instrumentación , Diseño de Equipo , Humanos , Función Ventricular
18.
Proc Inst Mech Eng H ; 214(2): 141-9, 2000.
Artículo en Inglés | MEDLINE | ID: mdl-10825772

RESUMEN

The heart can be studied using ultrasound techniques. The shape of the heart, its chambers, wall thicknesses, wall tissue characteristics as well as motion of walls and valve leaflets are all diagnostic information. In addition, the blood velocity and its timing within the cardiac cycle is an important diagnostic tool. In the present paper focus will be limited to the analysis of the left ventricular function as observed with two-dimensional and three-dimensional echocardiography and the characteristics of backscattered ultrasound information from the left ventricular chamber wall. Function of the heart is often studied by observation of local wall motion or comparison of chamber volume in maximum and minimum shapes during the cardiac cycle (ejection fraction). Integrated backscatter from the wall is described in examples of cardiac transplantation and hypertrophy. Study of cyclic variation of frequency-dependent attenuation and integrated backscatter indicates that these are independent parameters.


Asunto(s)
Ecocardiografía/métodos , Corazón/fisiología , Función Ventricular Izquierda , Animales , Cardiomegalia/diagnóstico por imagen , Cardiomegalia/fisiopatología , Trasplante de Corazón , Humanos
19.
Eur Heart J ; 21(5): 397-406, 2000 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-10666354

RESUMEN

AIMS: To risk stratify and shorten hospital stay in patients with spontaneous (resting) chest pain and a non-diagnostic electrocardiogram (ECG). METHODS AND RESULTS: The study comprised 102 patients (mean age 58+/-12 years, 67 men) with spontaneous chest pain and a non-diagnostic ECG. Forty-three patients had suspected coronary artery disease and 59 had known (but of unknown actual significance) coronary artery disease. All patients underwent serial creatine kinase enzyme measurements, continuous ECG monitoring for at least 12 h and early dobutamine-atropine stress echocardiography in patients with negative creatine kinase enzymes and normal findings at ECG monitoring. Dobutamine-atropine stress echocardiography was considered positive in patients with new or worsening wall thickening abnormalities. Patients with negative dobutamine-atropine stress echocardiography were discharged after the test. In-hospital and 6 month follow-up events noted were cardiac death, non-fatal myocardial infarction, unstable angina, and coronary artery bypass surgery or angioplasty. Thirteen patients had evidence of evolving myocardial infarction by elevated creatine kinase enzymes, or unstable angina by ECG monitoring. In the remaining 89 patients, dobutamine-atropine stress echocardiography was performed after a median observation period of 31 h (range 12-68 h). During dobutamine-atropine stress echocardiography no serious complications (death, non-fatal myocardial infarction, sustained ventricular tachycardia or ventricular fibrillation) occurred. Dobutamine-atropine stress echocardiography results were of poor quality in three, non-diagnostic in six, negative in 44 and positive in 36 patients. In the 80 patients with diagnostic dobutamine-atropine stress echocardiography, variables associated with in-hospital events (n=7) were history of exertional angina (P<0. 005), chest pain score (P<0.005), stress-induced angina (P<0.001) and positive dobutamine-atropine stress echocardiography (P<0.005). Variables associated with follow-up events (n=11) were history of exertional angina (P<0.05), chest pain score (P<0.001), stress-induced angina (P<0.01) and positive dobutamine-atropine stress echocardiography (P<0.01). At multivariate analysis the only significant predictor of events was positive dobutamine-atropine stress echocardiography (P<0.01). CONCLUSION: Early dobutamine-atropine stress echocardiography may safely distinguish between low- and high-risk subsets for subsequent cardiac events in patients with spontaneous chest pain and a non-diagnostic ECG.


Asunto(s)
Atropina , Dolor en el Pecho/diagnóstico por imagen , Enfermedad Coronaria/diagnóstico por imagen , Dobutamina , Ecocardiografía , Electrocardiografía , Dolor en el Pecho/diagnóstico , Dolor en el Pecho/epidemiología , Enfermedad Coronaria/diagnóstico , Enfermedad Coronaria/epidemiología , Servicio de Urgencia en Hospital , Femenino , Estudios de Seguimiento , Hemodinámica/efectos de los fármacos , Humanos , Tiempo de Internación/estadística & datos numéricos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Pronóstico , Seguridad , Factores de Tiempo , Resultado del Tratamiento
20.
Pol Arch Med Wewn ; 103(1-2): 35-40, 2000.
Artículo en Polaco | MEDLINE | ID: mdl-11236256

RESUMEN

Harmonic imaging is a new imaging modality using nonlinear acoustic response, which is particularly sensitive for the particles of contrast agents. Our study was designed to compare the potential of harmonic echocardiographic imaging of the left ventricle using a contrast agent, Levovist to improve the detection of endocardium in patients with suboptimal image quality. 40 patients were studied using standard transthoracic apical views of the left ventricle patients using fundamental frequency and second harmonic frequency after and intravenous injection of 2.5 g Levovist. The quality of endocardial delineation in 16 standard segments was scored from 0 to 2. Endocardial visualization index was calculated as a mean of the scores to express overall diagnostic quality. Harmonic imaging with contrast significantly improved left ventricular endocardial border detection (endocardial visualization index at baseline 1.24 +/- 0.41, with contrast 1.63 +/- 0.38; p < 0.001). The improvement was qualitatively observed in all parts of the left ventricle: in apex (2.4 +/- 0.8), in the middle part (2.5 +/- 0.9) and slightly less in the basal part (2.1 +/- 1.1) as scored on a 0-3 scale. The number of invisible segments decreased from 124 (fundamental) to 50 in contrast harmonic mode. The persistence of the contrast enhancement, prolonged in harmonic as compared to fundamental imaging (284 +/- 136s vs 117 +/- 87s; p < 0.001) enabled convenient recording of all necessary views. Harmonic imaging after an intravenous injection of Levovist significantly improves the visualization of left ventricular endocardial border. Prolonged contrast effect after a single bolus enhances the pertinence of the method in clinical practice.


Asunto(s)
Ecocardiografía/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Aumento de la Imagen/métodos , Polisacáridos , Disfunción Ventricular Izquierda/diagnóstico por imagen , Adulto , Anciano , Medios de Contraste , Femenino , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...