Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 266
Filtrar
2.
Artículo en Inglés | MEDLINE | ID: mdl-38544809
3.
J Interv Card Electrophysiol ; 67(3): 599-607, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37691082

RESUMEN

BACKGROUND: Recent anatomic and electrophysiologic evidence has provided new insight into the anatomic substrate. Previous reports on electroanatomic mapping (EAM) of the circuit of atrioventricular nodal reentrant tachycardia (AVNRT) have been limited by mapping only the triangle of Koch on the right side of the septum and by the use of conventional mapping tools. The objectives are to obtain comprehensive high-resolution mapping of typical AVNRT and to investigate the role of the atrioventricular ring tissues in the circuit. METHODS: We employed EAM with the use of novel modules and algorithms for studying typical AVNRT from the right and the left sides of the septum. RESULTS: We performed extensive mapping of both the atrial septum and the septal vestibule of the tricuspid valve during typical AVNRT in 9 (6 females) patients, aged 49.6 ± 12.1 years. In two of these, left septal mapping was also obtained through the aorta. The earliest initial activation was variable, emanating from the superior or medial septum. The impulse consistently appeared below the orifice of the coronary sinus, at the site where its inferoanterior margin merged with the septal vestibule of the tricuspid valve at its entrance to the right atrium. It then returned to the initial activation site, presumably through the septal vestibular myocardium. The left septal activation area corresponded to that recorded on the right side. CONCLUSIONS: Typical AVNRT uses a circuit confined within the pyramid of Koch from the AV node to the septal isthmus, involving the myocardial walls of the pyramidal space.


Asunto(s)
Tabique Interatrial , Ablación por Catéter , Taquicardia por Reentrada en el Nodo Atrioventricular , Femenino , Humanos , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Nodo Atrioventricular , Atrios Cardíacos , Miocardio , Electrocardiografía
4.
Artículo en Inglés | MEDLINE | ID: mdl-37860698
7.
J Interv Card Electrophysiol ; 66(4): 991-996, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36355272

RESUMEN

BACKGROUND: Mathematical modelling has allowed calculation of the length of the slow and fast pathways in typical atrioventricular nodal reentrant tachycardia (AVNRT). The length of the slow pathway has been correlated with the measured length of the right inferior extension in human histologic specimens, but no histology data exist about the fast pathway. METHODS: In preparations of cadaveric human hearts, the AV node was identified, and the site of the fast pathway was projected according to both existing evidence and results of our electroanatomic mapping. This permitted measurement of the length of the fast pathway as a limb of the tachycardia circuit. RESULTS: Measurements of the length of the projected area of the fast pathway on histology specimens were performed in 8 hearts. The estimated length of the fast pathway was 39.6 ± 5.8 mm (range: 30.4-45.9 mm). These numbers are comparable to those produced by mathematical calculations of the length of the fast pathway. CONCLUSIONS: Typical AVNRT uses a circuit from the AV node to the septal isthmus of an average size of 5-6 cm, confined within the pyramid of Koch.


Asunto(s)
Ablación por Catéter , Taquicardia por Reentrada en el Nodo Atrioventricular , Humanos , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Nodo Atrioventricular , Fascículo Atrioventricular , Arritmias Cardíacas , Taquicardia , Electrocardiografía , Ablación por Catéter/métodos
8.
Arrhythm Electrophysiol Rev ; 11: e16, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35990107

RESUMEN

Mitral valve prolapse (MVP) is a common condition present in 1-3% of the population. There has been evidence that a subset of MVP patients is at higher risk of sudden cardiac death. The arrhythmogenic mechanism is related to fibrotic changes in the papillary muscles caused by the prolapsing valve. ECG features include ST-segment depression, T wave inversion or biphasic T waves in inferior leads, and premature ventricular contractions arising from the papillary muscles and the fascicular system. Echocardiography can identify MVP and mitral annular disjunction, a feature that has significant negative prognostic value in MVP. Cardiac MRI is indicated for identifying fibrosis. Patients with high-risk features should be referred for further evaluation. Catheter ablation and mitral valve repair might reduce the risk of malignant arrhythmia. MVP patients with high-risk features and clinically documented ventricular arrhythmia may also be considered for an ICD.

10.
J Interv Card Electrophysiol ; 63(1): 109-114, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33550494

RESUMEN

PURPOSE: Bidirectional block of the cavo-tricuspid isthmus (CTI) is an established endpoint of CTI-dependent atrial flutter (AFl) ablation. Differential pacing has been used to evaluate the CTI block. The purpose of this study is to describe a modified differential pacing technique to evaluate the CTI block. METHODS: Sixty-two patients underwent radiofrequency (RF) ablation of CTI-dependent AFl. The acute endpoints were non-inducibility of the AFl, and verification of the bidirectional CTI block by our methodology. Pacing was performed in the CS with an ablation catheter positioned immediately lateral to the CTI ablation line, and then 1-2 cm more laterally. The stimulus-to-ablation catheter atrial electrogram intervals were measured at these sites (StimCS-Abl1 and StimCS-Abl2, respectively). Pacing with the ablation catheter also was performed at these 2 sites, and the stimulus-to-CS electrogram intervals (StimABL1-CS and StimABL2-CS) were measured. The criteria for the bidirectional block were StimCS-Abl1 > StimCS-Abl2, and StimABL1-CS > StimABL2-CS. Clinical efficacy was defined as freedom from recurrent AFl during follow-up. RESULTS: Following 12.2 ± 3.7 min of RF delivery across the CTI, intervals were StimCS-Abl1 = 181.2 ± 22.7 ms and StimABL1-CS = 181.0 ± 23.6 ms, and StimCS-Abl2 = 152.2 ± 26.5 ms and StimABL2-CS = 151.2 ± 22.7 (P < 0.001). Atrial flutter was rendered not inducible in all patients, and no procedural complications were encountered. During the next 15.9 ± 0.7 months, two patients were lost to follow-up, and among the 62 other patients, one (1.7%) had flutter recurrence. CONCLUSIONS: The bidirectional CTI block can be assessed quickly and easily using only the ablation and CS catheters for differential pacing.


Asunto(s)
Aleteo Atrial , Ablación por Catéter , Aleteo Atrial/cirugía , Técnicas Electrofisiológicas Cardíacas , Humanos , Resultado del Tratamiento
12.
Arrhythm Electrophysiol Rev ; 10(3): 131, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34777815
13.
Europace ; 23(10): 1596-1602, 2021 10 09.
Artículo en Inglés | MEDLINE | ID: mdl-34240123

RESUMEN

AIMS: The exact circuit of atrioventricular nodal re-entrant tachycardia (AVNRT) remains elusive. To assess the location and dimensions of the AVNRT circuit. METHODS AND RESULTS: Both typical and atypical AVNRT were induced at electrophysiology study of 14 patients. We calculated the activation time of the fast and slow pathways, and consequently, the length of the slow pathway, by assuming an average conduction velocity of 0.04 mm/ms in the nodal area. The distance between the compact atrioventricular node and the slow pathway ablating electrode was measured on three-dimensionally reconstructed fluoroscopic images obtained in diastole and systole. We also measured the length of the histologically discrete right inferior nodal extension in 31 human hearts. The length of the slow pathway was calculated to be 10.8 ± 1.3 mm (range 8.2-12.8 mm). The distance from the node to the ablating electrode was measured in five patients 17.0 ± 1.6 mm (range 14.9-19.2 mm) and was consistently longer than the estimated length of the slow pathway (P < 0.001). The length of the right nodal inferior extension in histologic specimens was 8.1 ± 2.3 mm (range 5.3-13.7 mm). There were no statistically significant differences between these values and the calculated slow pathway lengths. CONCLUSION: Successful ablation affects the tachycardia circuit without necessarily abolishing slow conduction, probably by interrupting the circuit at the septal isthmus.


Asunto(s)
Ablación por Catéter , Taquicardia por Reentrada en el Nodo Atrioventricular , Taquicardia Ventricular , Nodo Atrioventricular/diagnóstico por imagen , Nodo Atrioventricular/cirugía , Fascículo Atrioventricular , Electrocardiografía , Frecuencia Cardíaca , Humanos , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía
14.
JACC Case Rep ; 3(3): 484-485, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34317563
15.
J Am Heart Assoc ; 10(12): e020865, 2021 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-34075778

RESUMEN

Background Low-level tragus stimulation (LLTS) has been shown to significantly reduce atrial fibrillation (AF) burden in patients with paroxysmal AF. P-wave alternans (PWA) is believed to be generated by the same substrate responsible for AF. Hence, PWA may serve as a marker in guiding LLTS therapy. We investigated the utility of PWA in guiding LLTS therapy in patients with AF. Methods and Results Twenty-eight patients with AF were randomized to either active LLTS or sham (earlobe stimulation). LLTS was delivered through a transcutaneous electrical nerve stimulation device (pulse width 200 µs, frequency 20 Hz, amplitude 10-50 mA), for 1 hour daily over a 6-month period. AF burden over 2-week periods was assessed by noninvasive continuous ECG monitoring at baseline, 3 months, and 6 months. A 5-minute control ECG for PWA analysis was recorded during all 3 follow-up visits. Following the control ECG, an additional 5-minute ECG was recorded during active LLTS in all patients. At baseline, acute LLTS led to a significant rise in PWA burden. However, active patients receiving chronic LLTS demonstrated a significant reduction in both PWA and AF burden after 6 months (P<0.05). Active patients who demonstrated an increase in PWA burden with acute LLTS showed a significant drop in AF burden after 6 months of chronic LLTS. Conclusions Chronic, intermittent LLTS resulted in lower PWA and AF burden than did sham control stimulation. Our results support the use of PWA as a potential marker for guiding LLTS treatment of paroxysmal AF.


Asunto(s)
Fibrilación Atrial/terapia , Atrios Cardíacos/fisiopatología , Frecuencia Cardíaca , Estimulación Eléctrica Transcutánea del Nervio , Estimulación del Nervio Vago , Potenciales de Acción , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Prueba de Estudio Conceptual , Factores de Tiempo , Resultado del Tratamiento
17.
Am J Cardiol ; 141: 7-15, 2021 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-33220322

RESUMEN

The impact of the anatomic characteristics of coronary stenoses on the development of future coronary thrombosis has been controversial. This study aimed at identifying the anatomic and flow characteristics of left anterior descending (LAD) coronary artery stenoses that predispose to myocardial infarction, by examining angiograms obtained before the index event. We identified 90 patients with anterior ST-elevation myocardial infarction (STEMI) for whom coronary angiograms and their reconstruction in the three-dimensional space were available at 6 to 12 months before the STEMI, and at the revascularization procedure. The majority of culprit lesions responsible for STEMI occurred between 20 and 40 mm from the LAD ostium, whereas the majority of stable lesions not associated with STEMI were found in distances >60 mm (p < 0.001). Culprit lesions were significantly more stenosed (diameter stenosis 68.6 ± 14.2% vs 44.0 ± 10.4%, p < 0.001), and significantly longer than stable ones (15.3 ± 5.4 mm vs 9.2 ± 2.5 mm, p < 0.001). Bifurcations at culprit lesions were significantly more frequent (88.8%) compared with stable lesions (34.4%, p < 0.001). Computational fluid dynamics simulations demonstrated that hemodynamic conditions in the vicinity of culprit lesions promote coronary thrombosis due to flow recirculation. A multiple logistic regression model with diameter stenosis, lesion length, distance from the LAD ostium, distance from bifurcation, and lesion symmetry, showed excellent accuracy in predicting the development of a culprit lesion (AUC: 0.993 [95% CI: 0.969 to 1.000], p < 0.0001). In conclusion, specific anatomic and hemodynamic characteristics of LAD stenoses identified on coronary angiograms may assist risk stratification of patients by predicting sites of future myocardial infarction.


Asunto(s)
Estenosis Coronaria/diagnóstico por imagen , Trombosis Coronaria/diagnóstico por imagen , Hemodinámica , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Anciano , Angiografía Coronaria , Estenosis Coronaria/complicaciones , Estenosis Coronaria/fisiopatología , Trombosis Coronaria/etiología , Trombosis Coronaria/fisiopatología , Trombosis Coronaria/cirugía , Femenino , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/etiología , Infarto del Miocardio/fisiopatología , Infarto del Miocardio/cirugía , Revascularización Miocárdica , Modelación Específica para el Paciente , Estudios Retrospectivos , Infarto del Miocardio con Elevación del ST/etiología , Infarto del Miocardio con Elevación del ST/fisiopatología , Infarto del Miocardio con Elevación del ST/cirugía , Índice de Severidad de la Enfermedad
18.
Hellenic J Cardiol ; 62(1): 48-54, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-32956809

RESUMEN

OBJECTIVE: In 2008, the radiofrequency ablation (RFA) procedures registry of the Hellenic Society of Cardiology was created. This online database allowed electrophysiologists around the country to input data for all performed ablation procedures. The aim of this study is to provide a thorough report and interpretation of the data submitted to the registry between 2008 and 2018. METHODS: In 2008, a total of 27 centers/medical teams in 24 hospitals were licensed to perform RFA in Greece. By 2018, the number had risen to 31. Each center was tasked with inserting their own data into the registry, which included patient demographics (anonymized), type of procedure and technique, complications, and outcomes. RESULTS: A total of 18587 procedures in 17900 patients were recorded in the period of 2008-2018. By 2018, slightly more than 70% of procedures were performed in 7 high-volume centers (>100 cases/year). The most common procedure since 2014 was atrial fibrillation ablation, followed by atrioventricular nodal reentry tachycardia ablation. Complication rates were low, and success rates remained high, whereas the 6-month relapse rates declined steadily. CONCLUSION: This online RFA registry has proved that ablation procedures in Greece have reached a very high standard, with results and complication rates comparable to European and American standards. Ablation procedures for atrial fibrillation are increasing constantly, with it being the most common intervention over the last 6-year period, although the absolute number of procedures still remains low, compared to other European countries.


Asunto(s)
Fibrilación Atrial , Cardiología , Ablación por Catéter , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Grecia/epidemiología , Humanos , Sistema de Registros , Estudios Retrospectivos
19.
Arrhythm Electrophysiol Rev ; 10(4): 223-224, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35106171
20.
Clin Appl Thromb Hemost ; 26: 1076029620964590, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33284037

RESUMEN

In patients with stable coronary artery disease (CAD) blood hypercoagulability figures among factors leading to thrombosis. Tissue factor (TF) exposure at ruptured plaque initiates blood coagulation and hypercoagulability is responsible for thrombus formation. Early identification of patients eligible for angiography is a challenging issue for effective prevention of ACS. This pilot study aimed to identify biomarkers of hypercoagulability that can be prospectively used in risk assessment tools for the evaluation of CAD severity. Biomarkers of hypercoagulability could be a used for the evaluation of CAD severity. Platelet-poor plasma from 66 patients who were referred to coronary angiography was assessed for thrombin generation, phospholipid-dependent clotting time (Procoag-PPL ® ) and D-Dimers, and evaluated against atherosclerotic burden. Patients with CAD, as compared to controls, showed attenuated thrombin generation lag time: 4.7 (3.8-5.4) min versus 2.5 (2.1-2.9) min; p < 0.0001, shorter Procoag-PPL® clotting time 55.0(32-66) s versus 62.8 (42-85) s; p = 0.001), and higher D-Dimer levels 0.509 (0.27-2.58) µg/ml versus 0.309 (0.23-0.39) µg/ml; p = 0.038. Multivariate logistic regression model showed excellent discriminatory value in predicting CAD severity. The ROADMAP-CAD study showed that the Procoag-PPL® clotting time and thrombin Peak are informative for the the burden of the coronary atherosclerotic disease. The clinical relevance of this observation in the development of a new clinic-biological risk assessment model for early diagnosis of severe CAD has to be examined in a prospective study.


Asunto(s)
Enfermedad de la Arteria Coronaria/sangre , Trombofilia/sangre , Anciano , Biomarcadores/sangre , Coagulación Sanguínea , Pruebas de Coagulación Sanguínea , Enfermedad de la Arteria Coronaria/diagnóstico , Femenino , Productos de Degradación de Fibrina-Fibrinógeno/análisis , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Estudios Prospectivos , Medición de Riesgo , Trombofilia/diagnóstico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...