Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Cardiovasc Revasc Med ; 18(7): 475-481, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28923692

RESUMEN

BACKGROUND: BioFreedom is a polymer- and carrier-free drug-coated stent that delivers Biolimus A9 to the vessel wall. Our purpose was to evaluate the efficacy and safety of this DCS in patients with short-duration dual antiplatelet therapy. METHODS: The BioFreedom US IDE feasibility trial was a single-arm, open-label, prospective study of patients requiring stenting of de novo lesions. Patients received 3 months of DAPT, repeat angiography at 9 months, and clinical follow-up at multiple intervals. A subgroup also underwent intravascular ultrasound (IVUS) interrogation. The primary safety end point was major adverse cardiac events, defined as a composite of cardiac death, myocardial infarction, target lesion revascularization, or stent thrombosis. The primary efficacy end point, in-stent late lumen loss at 9 months, was compared with a historical control from a first-generation paclitaxel-eluting stent. RESULTS: A total of 72 patients from 10 sites received BioFreedom DCS implanted in 83 de novo lesions. At 9 months, the incidence of composite MACE was 8.4%, and TLR was 1.5%. Short DAPT was safe without occurrence of stent thrombosis. The primary end point of LLL was 0.32±0.53 mm. Paired IVUS analyses comparing postprocedural with 9-month measurements showed low in-stent neointimal volume obstruction (5.39±5.28%) and low neointimal hyperplasia (7.43±8.04 mm3). CONCLUSIONS: This study's angiography and IVUS assessments demonstrated that the BioFreedom DCS has anti-restenotic efficacy similar to first-generation DES. In the absence of concerning safety signals, this DCS should be considered effective and safe for patients who require a shorter duration of DAPT.


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Sirolimus/análogos & derivados , Anciano , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Reestenosis Coronaria/prevención & control , Esquema de Medicación , Quimioterapia Combinada , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Inhibidores de Agregación Plaquetaria/administración & dosificación , Valor Predictivo de las Pruebas , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Sirolimus/administración & dosificación , Sirolimus/efectos adversos , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía Intervencional , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA