Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Perfusion ; : 2676591231197524, 2023 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-37608700

RESUMEN

OBJECTIVES: del Nido cardioplegia is utilized for myocardial protection in adult patients undergoing cardiac surgery; however, no standardized re-dosing protocol exists. We describe perfusion characteristics and clinical outcomes in adult cardiac surgery patients who were re-dosed with del Nido cardioplegia. METHODS: Chart review was performed for adult patients undergoing cardiac surgery (specific inclusion/exclusion criteria below) who received exactly two doses of del Nido cardioplegia from 2012 to 2019; n = 542 patients. The main outcome was a composite endpoint comprised of operative mortality, myocardial infarction, post-operative cardiac support device (CSD), and postoperative decrease in ejection fraction (EF), which was analyzed via multivariable logistic regression (MVLR). A secondary analysis evaluated postoperative vasoactive-inotropic scores (VIS) via gamma log link regression (GLLR) as a more physiologic indication of myocardial recovery. RESULTS: MVLR demonstrated that increased total cardiopulmonary bypass (CPB) time was associated with a positive composite outcome (p < .001), whereas time between doses (p = .237) and the volume of each dose was not (p = .626). GLLR also demonstrated that prolonged CBP, decreased EF, congestive heart failure at time of surgery, and low hematocrit at the start of the surgery were all associated with higher VIS. CONCLUSIONS: In this retrospective study, variations in re-dosing strategy for del Nido cardioplegia do not affect postoperative outcomes and increased CPB time is associated with increased operative mortality, myocardial infarction, need for post-operative CSDs, and reduced postoperative EF, and increased VIS, irrespective of the re-dosing strategy. Further studies are warranted to to identify additional patient and operative characteristics that predispose to complications.

2.
Eur J Cardiothorac Surg ; 62(5)2022 10 04.
Artículo en Inglés | MEDLINE | ID: mdl-36165688

RESUMEN

OBJECTIVES: del Nido cardioplegia is used to pharmacologically arrest the heart during cardiac surgery and decrease reperfusion- and ischaemia-related myocardial injury. Studies have demonstrated the physiological differences between male and female hearts, potentially related to cardiac size or myocyte calcium handling; we aimed to assess for between-sex differences in clinical outcomes after receipt of del Nido cardioplegia. METHODS: Patients who underwent coronary artery bypass or coronary artery bypass graft/valve surgery at our institution using del Nido cardioplegia (January 2014 to December 2019) were included (n = 2118). Clinical data were collected retrospectively. After the creation of a propensity-matched cohort (n = 1252), multivariable logistic regression was used to analyse binary postoperative outcomes, and a Gamma model was used for a continuous postoperative outcome. Our primary end-point was a composite end-point comprised of 30-day mortality and/or need for a post-bypass mechanical support device. RESULTS: The final cohort included 459 females and 793 males (matched up to 1:2, all standardized mean differences <0.1). Multivariable logistic regression showed that biological sex was not associated with the composite primary end-point (odds ratio = 0.898, P = 0.779). A Gamma model indicated that there were no sex-related differences in vasoactive-inotropic scores reflecting vasopressor and inotrope usage at the time of patient operating room exit (exp[est] = 1.394, P = 0.189). CONCLUSIONS: Our findings showed no significant between-sex differences in clinical outcomes after receiving del Nido cardioplegia, suggesting adequate myocardial protection as currently administered. Further research is warranted to elicit if there are sex-based differences between cardioplegic solutions. IRB APPROVAL DATE (PROTOCOL NUMBER): 26 May 2021 (AAAR8359).


Asunto(s)
Soluciones Cardiopléjicas , Caracteres Sexuales , Calcio , Soluciones Cardiopléjicas/uso terapéutico , Femenino , Paro Cardíaco Inducido/efectos adversos , Paro Cardíaco Inducido/métodos , Humanos , Masculino , Estudios Retrospectivos
3.
J Am Soc Echocardiogr ; 35(2): 206-216, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34508836

RESUMEN

BACKGROUND: There is a lack of comprehensive echocardiographic data to allow discrimination of normal versus abnormal mechanical prosthetic tricuspid valve (MPTV) leaflet function. The identification of such parameters is essential to optimize diagnostic and therapeutic measures. METHODS: The authors investigated bileaflet MPTV function by comparing transthoracic echocardiographic data from 21 episodes of leaflet dysfunction due to valve thrombosis in 12 patients with data from 56 individuals with normal MPTV function. All episodes of dysfunction were confirmed by transesophageal echocardiography and/or cine fluoroscopy. Transthoracic echocardiography-derived two-dimensional, color, and spectral Doppler variables, including MPTV peak early diastolic velocity (E velocity), mean gradient, pressure half-time, time-velocity integral (TVI) of the MPTV, ratio of TVIMPTV to TVI of the left ventricular outflow tract (LVOT) and TVI of the right ventricular outflow tract (RVOT), and continuity-derived effective orifice area, were measured in both groups. RESULTS: Most episodes of MPTV dysfunction resulted from simultaneous involvement of both leaflets (57%), with leaflet(s) often immobilized in the open or semiopen position (71%). Transthoracic and transesophageal echocardiography performed similarly in detecting abnormal leaflet motion (90% vs 88%, P = .68), whereas transesophageal echocardiography was better in identifying MPTV thrombosis (31% vs 14%, respectively, P = .01). Color Doppler demonstrated flow propagation abnormalities in 67% of episodes of leaflet dysfunction but not in the control group (P < .0001). Doppler variables associated with MPTV leaflet dysfunction included E velocity > 1.6 m/sec, mean gradient > 5 mm Hg, PHT > 157 msec, TVIMPTV > 42 cm, TVIMPTV/TVILVOT > 2.3, TVIMPTV/TVIRVOT > 3.0, and continuity-derived effective orifice area ≤ 1.1 cm2, with most variables showing high and similar accuracy (area under the curve ≥ 95%). CONCLUSIONS: This study represents the first comprehensive echocardiographic assessment of MPTV leaflet dysfunction that provides parameters and criteria to distinguish normal versus abnormal prosthetic valve function.


Asunto(s)
Enfermedades de las Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Ecocardiografía/métodos , Ecocardiografía Doppler , Humanos , Válvula Mitral/diagnóstico por imagen
4.
Echocardiography ; 38(11): 1973-1977, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34755387

RESUMEN

Constrictive pericarditis (CP) is a curable cause of diastolic heart failure with prior cardiac surgery being a recognizable etiology. We report a patient who developed CP one year following heart transplantation. Several clinical and imaging related factors may lead to diagnostic delays in similar patients, including the mistaken belief that transplanted hearts are devoid of pericardium and thus do not develop constriction. Post-transplantation pericardial effusion, mediastinitis, and cardiac rejection predispose to future CP. Caretakers should consider this entity in allograft recipients who develop heart failure symptoms of unclear etiology.


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Derrame Pericárdico , Pericarditis Constrictiva , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/etiología , Trasplante de Corazón/efectos adversos , Humanos , Pericarditis Constrictiva/diagnóstico por imagen , Pericarditis Constrictiva/etiología , Pericardio
5.
J Am Soc Echocardiogr ; 34(11): 1119-1136, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34224827

RESUMEN

Ultrasound is the imaging modality of choice for the initial evaluation of disorders that involve the abdominal aorta (AA). The diagnostic value of ultrasound resides in its ability to allow assessment of the anatomy and structure of the AA using two- dimensional, three-dimensional, and contrast-enhanced imaging. Moreover, ultrasound permits evaluation of the physiologic and hemodynamic consequences of abnormalities through Doppler interrogation of blood flow, thus enabling the identification and quantification of disorders within the AA and beyond its boundaries. The approach to ultrasound imaging of the AA varies, depending on the purpose of the study and whether it is performed in a radiology or vascular laboratory or in an echocardiography laboratory. The aim of this review is to demonstrate the usefulness of ultrasound imaging for the detection and evaluation of disorders that involve the AA, detail the abnormalities that are detected or further assessed, and outline its value for echocardiographers, sonographers, and radiologists.


Asunto(s)
Aorta Abdominal , Ecocardiografía , Aorta Abdominal/diagnóstico por imagen , Hemodinámica , Humanos , Ultrasonografía
6.
J Am Soc Echocardiogr ; 34(3): 223-236, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33678222

RESUMEN

Data obtained from echocardiographic studies are used on a daily basis to guide clinical decision-making regarding patient management and the need for additional diagnostic investigations. Interrogation of blood flow in the pulmonary veins by spectral, most often pulsed-wave, Doppler is an important component of any comprehensive echocardiographic study. Whereas it is most often used to help assess left-sided filling pressure and quantify the severity of mitral regurgitation, the pulmonary vein Doppler profile provides added diagnostic insights into several disorders that affect heart function and allows assessment of their hemodynamic consequences on the heart. The aim of this review is to summarize current knowledge in the field of PV Doppler interrogation, highlight the physiological and pathological parameters that influence it, and delineate the manifestations of various cardiovascular disorders on the flow profile.


Asunto(s)
Insuficiencia de la Válvula Mitral , Venas Pulmonares , Velocidad del Flujo Sanguíneo , Ecocardiografía Doppler , Hemodinámica , Humanos , Venas Pulmonares/diagnóstico por imagen , Ultrasonografía Doppler
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA