1.
J Magn Reson ; 248: 126-30, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25442781

RESUMEN

A new method for fast 2D Electron Paramagnetic Resonance Imaging (EPRI) is presented. To reduce the time of projections acquisition we propose to combine rapid scan of Zeeman magnetic field using high frequency sinusoidal modulation with simultaneously applied magnetic field gradient, whose orientation is changed at low frequency. The correctness of the method is confirmed by studies carried out on a phantom consisting of two LiPc samples. The images from the acquired data are reconstructed using iterative algorithms. The proposed method allows to reduce the image acquisition time up to 10 ms for 2D EPRI, and to detect the sinogram with infinitesimal angular step between projections.

2.
J Magn Reson ; 243: 1-7, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24705409

RESUMEN

A new method for fast spectral-spatial electron paramagnetic resonance imaging (EPRI) is presented. To reduce the time of projections acquisition we propose to combine rapid scan of Zeeman magnetic field using high frequency sinusoidal modulation with simultaneously applied magnetic field gradients, whose amplitude is modulated at low frequency. The correctness of the method is confirmed by studies carried out on a phantom consisting of two LiPc samples. The spectral-spatial images from the acquired data are reconstructed using iterative algorithms. The proposed method allows to acquire the spectral-spatial image with 800 projections at 200ms.

3.
Appl Magn Reson ; 44(5): 605-618, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23761951

RESUMEN

In this paper we use a simple analysis based on properties of the axial field generated by symmetrical multipoles to reveal all possible distributions of two coaxial pairs of circular windings, which result in systems featuring zero octupole and 32 pole magnetic moments (six-order systems). Homogeneity of magnetic field of selected systems is analyzed. It has been found that one of the derived systems generates homogenous magnetic field whose volume is comparable to that yielded by the eight-order system. The influence of the current distribution and the windings placement on the field homogeneity is considered. The table, graphs and equations given in the paper facilitate the choice of the most appropriate design for a given problem. The systems presented may find applications in low field electron paramagnetic resonance imaging, some functional f-MRI (nuclear magnetic resonance imaging) and bioelectromagnetic experiments requiring the access to the working space from all directions.

4.
Appl Magn Reson ; 43(3): 331-340, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23144535

RESUMEN

The design and construction of a high-performance, low-cost, and easy to assemble adiabatic extension set for homebuilt and commercial spectrometers is described. Described apparatus set was designed for the fast adiabatic passage generation and is based on direct digital synthesizer DDS. This solution gives generator high signal to noise ratio, phase stability even during frequency change which is only possible in expansive commercial high-end hardware. Critical synchronization and timing issues are considered and solutions are discussed. Different experimental conditions and techniques for the measurements are briefly discussed. The proposed system is very flexible and might be used for the measurement of low-frequency nuclear magnetic resonance.

SELECCIÓN DE REFERENCIAS