Int J Lab Hematol ; 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-39009028

RESUMEN

This guidance document has been prepared on behalf of the International Council for Standardization in Haematology (ICSH). The aim of the document is to provide guidance and recommendations for the performance and interpretation of activated partial thromboplastin time (APTT) and prothrombin time (PT) plasma mixing tests in clinical laboratories in all regions of the world. The following areas are included in this document: preanalytical, analytical, postanalytical, and quality assurance considerations as they relate to the proper performance and interpretation of plasma mixing tests. The recommendations are based on good laboratory practice, published data in peer-reviewed literature, and expert opinion.

2.
Haemophilia ; 24(3): 492-501, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29488668

RESUMEN

INTRODUCTION: Chromogenic substrate assays (CSA) to measure Factor IX (FIX) have recently become commercially available. However, information on their performance characteristics and use in diagnostic haemostasis laboratories remains limited. AIM: To evaluate the Hyphen Biomed (Hyphen) and Rossix FIX CSAs on fully automated coagulation analysers and compare them to the FIX one-stage assay (OSA). This study was conducted in a tertiary referral haemostasis laboratory associated with a haemophilia treatment centre. METHODS: Automated CSA protocols were adapted to the Sysmex CS2500 (CS2500) and Diagnostica Stago STA-R (STA-R) analysers. Samples assayed were from healthy volunteers, haemophilia B patients and FIX deficient plasma spiked with either plasma derived, recombinant or extended half-life FIX products. RESULTS: Reference intervals for Hyphen and Rossix assays were 73 IU/dL to 164 IU/dL and 73 IU/dL to 168 IU/dL, respectively, on the CS2500 analyser; and 84 IU/dL to 165 IU/dL for the Rossix assay on the STA-R. Repeatability across all method/analyser combinations resulted in CVs ranging from 0.8% to 5.4%. Between run reproducibility gave CVs <6.7% for all method/analyser combinations. In spiked samples, FIX recoveries were mostly within an acceptable limit of 100 ± 25% for BeneFIX® , Rixubis® and Alprolix® with some differences between CSAs. CONCLUSION: Both commercial factor FIX CSA kits can be adapted for Stago and Sysmex automated coagulation analysers. Reagent cost and workflow practices will need to be considered. These assays are potentially more consistent than OSA in measurement of replacement FIX products in haemophilia B patients.


Asunto(s)
Análisis Químico de la Sangre/métodos , Lipoproteínas/sangre , Adolescente , Adulto , Anciano , Automatización , Coagulación Sanguínea/efectos de los fármacos , Factor IX/farmacología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
4.
Haemophilia ; 22 Suppl 5: 72-7, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27405680

RESUMEN

The recent development of modified recombinant factor VIII (FVIII) and factor IX (FIX) therapeutic products with extended half-lives will create challenges for the haemostasis laboratory in obtaining recovery estimates of these products in clinical samples using existing assays. The new long-acting therapeutic concentrates contain molecular modifications of Fc fusion, site-specific of polyethylene glycol or albumin fusion. The optimum methods for monitoring each new product will need to be assessed individually and laboratories should select an assay which gives similar results to the assay used to assign potency to the product in question. For some extended half-life FVIII and FIX products some one stage assays are entirely unsuitable for monitoring purposes. For most products and assay reagents studied so far, and reviewed in this manuscript, chromogenic FVIII or FIX assays can be safely used with conventional plasma standards. If one stage assays are used then they should be performed using carefully selected reagents/methods which have been shown to recover activity close to the labelled potency for the specific product being monitored.


Asunto(s)
Pruebas de Coagulación Sanguínea , Compuestos Cromogénicos/química , Factor IX/análisis , Factor VIII/análisis , Factor IX/genética , Factor IX/metabolismo , Factor VIII/genética , Factor VIII/metabolismo , Humanos , Proteínas Recombinantes/análisis , Proteínas Recombinantes/biosíntesis , Proteínas Recombinantes/genética
5.
Anaesth Intensive Care ; 43(6): 734-9, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26603798

RESUMEN

This study evaluated the effects of haemodilution with either 6% hydroxyethyl starch (HES) 130/0.4 (Voluven(®)) or 0.9% normal saline (NS) on blood coagulation in vitro. Haemodilution with 6% HES 130/0.4 impaired coagulation, as indicated by the changes in thromboelastographic parameters k-time, α-angle and maximum amplitude. Light transmission aggregometry and multiple electrode aggregometry demonstrated that impaired platelet receptor function occurred only at high levels of haemodilution (40%) with both fluids, but there was no significant difference between the two fluids (P=0.05). The thromboelastographic functional fibrinogen assay showed that the fibrinogen component of clot strength was significantly impaired with haemodilution with HES 130/0.4 compared with haemodilution with NS (whole blood [14.4 ± 4.6 mm] versus 40% HES dilution [3.7 ± 1.9], [P=0.001]; versus 40% NS dilution [10.4 ± 4.6], [P=0.129]). These findings suggest that there is little difference between HES or NS in relation to coagulation or platelet function during minor or moderate haemodilution, but at high levels of haemodilution with HES, fibrinogen activity is more impaired compared with NS.


Asunto(s)
Coagulación Sanguínea/efectos de los fármacos , Plaquetas/fisiología , Hemodilución , Derivados de Hidroxietil Almidón/farmacología , Sustitutos del Plasma/farmacología , Tromboelastografía/métodos , Adolescente , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Soluciones
6.
Anaesth Intensive Care ; 43(2): 187-92, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25735683

RESUMEN

We investigated the in vitro viscoelastic changes of progressive haemodilution with 4% albumin compared with normal saline (NS) using rotational thromboelastometry (ROTEM(®), Pentapharm Co., Munich, Germany). Whole blood samples obtained from 20 healthy volunteers were diluted in vitro with 4% albumin or NS by 10%, 20% and 40%. Fibrinogen concentration and ROTEM(®) (EXTEM [screening test for the extrinsic haemostasis system], FIBTEM [EXTEM-based assay for the fibrin part of the clot]) variables including coagulation time, clot formation time (CFT), α-angle, maximum clot firmness and lysis index were measured in the undiluted sample and at each degree of haemodilution. There was no significant difference in fibrinogen concentration at equivalent haemodilutions with normal saline and 4% albumin solutions. Forty percent haemodilution with albumin significantly prolonged coagulation time (EXTEM P=0.007, FIBTEM P=0.0001) and significantly decreased lysis index (FIBTEM P=0.009) compared with NS. A significant decrease in maximum clot firmness from undiluted measurements (P=0.05) was observed at lower haemodilutions with albumin (20% with EXTEM, 10% with FIBTEM) compared with NS (40% with EXTEM and FIBTEM). The adverse effects of large degrees of haemodilution with 4% albumin solution are in excess of what can be explained by haemodilution alone. This study suggests that large degrees of haemodilution with albumin impair fibrinogen activity to a greater extent than equivalent degrees of haemodilution with NS.


Asunto(s)
Albúminas/farmacología , Coagulación Sanguínea/efectos de los fármacos , Hemodilución/métodos , Tromboelastografía/métodos , Adulto , Pruebas de Coagulación Sanguínea/métodos , Femenino , Voluntarios Sanos , Humanos , Técnicas In Vitro/métodos , Masculino , Valores de Referencia , Cloruro de Sodio/administración & dosificación
7.
Int J Lab Hematol ; 35(2): 222-4, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23020832

RESUMEN

INTRODUCTION: Studies have shown dabigatran to be an effective anticoagulant with an acceptable bleeding profile. None the less, these patients do suffer from bleeding complications. Unfortunately, there are currently no direct reversal agents to dabigatran or established guidelines on the management of bleeding in these circumstances. METHODS: We examined the effects on thrombin generation parameters, after ex-vivo spiking the plasma of patients on dabigatran (n = 8) with FEIBA(®). These parameters were measured using the calibrated automated thrombography (CAT) machine. RESULTS: In our study, we showed the ability of FEIBA(®) to improve the abnormal thrombin generation parameters caused by dabigatran in these patients. CONCLUSION: This provides evidence, lacking in the literature, that this agent may be able to provide haemostatic support in situations where dabigatran induced coagulopathy exists.


Asunto(s)
Antitrombinas/farmacología , Bencimidazoles/farmacología , Factores de Coagulación Sanguínea/uso terapéutico , Coagulación Sanguínea/efectos de los fármacos , Pruebas de Química Clínica/normas , beta-Alanina/análogos & derivados , Bencimidazoles/uso terapéutico , Trastornos de la Coagulación Sanguínea/tratamiento farmacológico , Dabigatrán , Humanos , Proyectos de Investigación , beta-Alanina/farmacología , beta-Alanina/uso terapéutico
9.
Haemophilia ; 16(4): 662-70, 2010 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-20070382

RESUMEN

The laboratory has a key role in the initial detection of factor inhibitors and an ongoing role in the measurement of inhibitor titres during the course of inhibitor eradication therapy. The most commonly seen factor inhibitors are those directed against factor VIII (FVIII), usually detected either using the original or Nijmegen-modified Bethesda assay. In view of previously demonstrated high variability in laboratory results for inhibitor assays, we have more extensively examined laboratory performance in the identification of FVIII inhibitors. Over the past 3 years, we conducted two questionnaire-based surveys and two wet-challenge surveys utilizing eight samples comprising no FVIII inhibitor (n = 1), or low-titre (n = 2), medium-titre (n = 3) or high-titre (n = 2) FVIII inhibitor. Four samples were tested by 42 laboratories in 2007, and four by 52 laboratories in 2009. High inter-laboratory variation was evident, with CVs around 50% not uncommon, and some 10% of all laboratories (or around 15% of laboratories using Bethesda method) failed to detect low-level inhibitors of around 1 BU mL(-1). Laboratories using the Nijmegen method appeared to perform better than those using a standard Bethesda assay, with lower evident assay variation and no false negatives. There was a wide variety of laboratory practice, with no two laboratories using exactly the same process for testing and interpretation of factor inhibitor findings. In conclusion, our study indicates that there is still much need for standardization and improvement in factor inhibitor detection, and we hope that our findings provide a basis for future improvements in this area.


Asunto(s)
Inhibidores de Factor de Coagulación Sanguínea/análisis , Pruebas de Coagulación Sanguínea/normas , Factor VIII/antagonistas & inhibidores , Australasia , Humanos , Garantía de la Calidad de Atención de Salud , Encuestas y Cuestionarios
10.
Int J Lab Hematol ; 31(6): 603-14, 2009 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-18691345

RESUMEN

The latest version of our Laboratory Information System haematology laboratory expert system that handles the output of Abbott Cell-Dyn Sapphires, CD4000s and a CD3200 full blood count analyser in three high-volume haematology laboratories is described. The three hospital laboratories use Cerner Millennium Version 2007.02 software and the expert system uses Cerner Millennium Discern Expert rules and some small Cerner Command Language in-house programs. The entire expert system is totally integrated with the area-wide database and has been built and maintained by haematology staff members, as has the haematology database. Using patient demographic data, analyser numeric results, analyser error and morphology flags and previous results for the patient, this expert system decides whether to validate the main full blood count indices and white cell differential, or if the analyser results warrant further operator intervention/investigation before verifying, whether a blood film is required for microscopic review and if abnormal results require phoning to the staff treating the patient. The principles of this expert system can be generalized to different haematology analysers and haematology laboratories that have different workflows and different software.


Asunto(s)
Recuento de Células Sanguíneas/instrumentación , Sistemas de Información en Laboratorio Clínico , Sistemas Especialistas , Pruebas Hematológicas/instrumentación , Adulto , Australia , Niño , Preescolar , Sistemas de Información en Laboratorio Clínico/instrumentación , Humanos , Lactante , Recién Nacido , Masculino , Programas Informáticos
12.
Haemophilia ; 12(6): 663-7, 2006 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17083518

RESUMEN

Inhibitors are an uncommon complication of mild haemophilia A but represent a severe disease, typically with high titre inhibitors and an associated high rate of bleeding. We present data from three patients with MHAI who were successfully treated with Rituximab alone and unequivocally prove that such inhibitors respond to this agent. A treatment protocol is suggested.


Asunto(s)
Anticuerpos Monoclonales/uso terapéutico , Hemofilia A/tratamiento farmacológico , Factores Inmunológicos/uso terapéutico , Adulto , Anciano , Anticuerpos Monoclonales/inmunología , Anticuerpos Monoclonales de Origen Murino , Hemofilia A/inmunología , Humanos , Tolerancia Inmunológica/inmunología , Factores Inmunológicos/inmunología , Inmunoterapia/métodos , Masculino , Persona de Mediana Edad , Rituximab , Resultado del Tratamiento
13.
Haemophilia ; 10(3): 232-42, 2004 May.
Artículo en Inglés | MEDLINE | ID: mdl-15086320

RESUMEN

Regular multilaboratory surveys of laboratories derived primarily from Australia, New Zealand and Southeast Asia have been conducted over the past 7 years to evaluate testing proficiency in the diagnosis of von Willebrand's disorder (VWD) and to assess changes to test practice. Participating laboratories (currently 45) are asked to perform their usual panel of tests for VWD, and then to self-interpret test results as to the likelihood (or not) of VWD, as well as to the potential subtype identified. Samples provided in the past two survey distributions (both conducted in 2003) were as follows. Survey part A/distribution 1: Normal donor plasma, plasma with borderline normal/reduced levels of VWF (x2) and plasma from an individual with type 2 A VWD. Survey part B/distribution 2 (family VWD study): Plasma from a father, mother and son with borderline normal/reduced von Willebrand factor (VWF), and a daughter with type 3 VWD. In line with previously published survey results, the interassay and within method coefficients of variation (CV) were similar for all assays (around 15-25%), although tending to be slightly higher for VWF:RCo and VWF:CB than VWF:Ag and FVIII:C. Most laboratories reported test values consistent with expected findings, and made correct interpretations or predictions regarding the nature of the samples, although discrepant assay results or interpretations are still seen in approximately 5-10% of responses (typically from laboratories using a more limited test panel or not performing the VWF:CB). Overall, problems with the non-identification of functional VWF discordance in type 2 VWD, the misidentification of functional VWF discordance in type 1 VWD, and difficulties in discriminating types 1 and 3 VWD appear to predominate. In comparison with previous surveys, performance of electro-immuno diffusion (EID) (or Laurel gel) procedures has now ceased, and a reduction in VWF:RCo and VWF:Multimer testing and an increase in latex immunoassay (LIA) testing is sustained. We conclude that laboratories are generally proficient in tests for VWD, and that diagnostic error rates are reduced when test panels are more comprehensive and include the VWF:CB.


Asunto(s)
Técnicas de Laboratorio Clínico/normas , Enfermedades de von Willebrand/diagnóstico , Humanos , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Control de Calidad , Calidad de la Atención de Salud
14.
Haemophilia ; 7(2): 180-9, 2001 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-11260278

RESUMEN

We have coevaluated a combination of test processes for diagnosing von Willebrand disease (vWD) and monitoring deamino-delta-D-arginine vasopressin (DDAVP) therapy. Using normal controls (n = 23), closure time (CT) ranges measured by PFA-100(R) were (mean +/- 2SD): (i) collagen/ADP cartridge (C/ADP): 67-127 s (ii) collagen/epinephrine (C/Epi): 94-162 s. From a panel of 125 patients undergoing evaluation for clinical haemostatic defects, 29/30 samples from patients with vWD [17/18 type 1, 1/1 type 3, 3/3 type 2A, 7/7 type 2B and 1/1 pseudo-vWD] gave prolonged CTs using C/Epi. The C/ADP was less sensitive, being normal in 7/18 of the type 1 vWD individuals, with higher sensitivity to more severe vWD. Individuals with haemophilia (six factor VIII-deficient, one factor XI-deficient) gave normal CTs, while those with clinical thrombocytopenia (n=13) gave normal or prolonged CTs, somewhat dependent on platelet count. The PFA-100 was also evaluated as a part of the laboratory monitoring procedure in patients with either vWD or haemophilia undergoing a DDAVP trial as a therapeutic management process. For vWD, correction of an initially prolonged CT by DDAVP, accompanied by normalization of von Willebrand factor (vWF) measurable by von Willebrand factor antigen, vWF collagen binding activity and vWF ristocetin cofactor assays (vWF:Ag, vWF:CBA and vWF:RCof), was achieved in type 1 vWD (n=5). In an individual with type 2A vWD, DDAVP normalized vWF:Ag and vWF:RCof, but had no apparent effect on the baseline maximally prolonged CT. In an individual with type 2B vWD, factor VIII/vWF concentrate also normalized vWF:Ag and vWF:RCof, but similarly had no apparent effect on the baseline maximally prolonged CT. vWF:CBA did not normalize for either of these individuals, potentially suggesting that normalization of vWF:CBA might be required for normalization of CT. This concept is supported by correlation analysis undertaken between CT and various vWF parameters. Among these, vWF:CBA held the strongest relationship in our data set, which showed an inverse progressive rise in CT for falling vWF:CBA. Based on these results, we would conclude that the PFA-100 is highly sensitive to the presence of vWD, and may thus provide a valuable screening test for vWD. Furthermore, the combined utility of the PFA-100 and vWF:CBA as markers of DDAVP responsiveness may prove to be simple, quick but powerful, predictors for its clinical efficacy.


Asunto(s)
Desamino Arginina Vasopresina/administración & dosificación , Monitoreo de Drogas/instrumentación , Enfermedades de von Willebrand/diagnóstico , Trastornos de las Proteínas Sanguíneas/sangre , Trastornos de las Proteínas Sanguíneas/diagnóstico , Trastornos de las Proteínas Sanguíneas/tratamiento farmacológico , Estudios de Casos y Controles , Técnicas de Laboratorio Clínico/normas , Desamino Arginina Vasopresina/sangre , Factor VIII/administración & dosificación , Factor VIII/metabolismo , Hemostáticos/administración & dosificación , Hemostáticos/sangre , Humanos , Pruebas de Función Plaquetaria , Valores de Referencia , Sensibilidad y Especificidad , Enfermedades de von Willebrand/tratamiento farmacológico
15.
Arch Intern Med ; 158(11): 1265-7, 1998 Jun 08.
Artículo en Inglés | MEDLINE | ID: mdl-9625406

RESUMEN

Three patients with renal failure caused by atheroembolism following cardiac vascular procedures had multiple, bilateral retinal cholesterol emboli. Ophthalmoscopy in such patients represents a noninvasive diagnostic technique that is underutilized.


Asunto(s)
Embolia por Colesterol/diagnóstico , Enfermedades Renales/diagnóstico , Enfermedades de la Retina/complicaciones , Anciano , Embolia por Colesterol/complicaciones , Resultado Fatal , Femenino , Humanos , Enfermedades Renales/complicaciones , Persona de Mediana Edad , Oftalmoscopía
16.
Transplantation ; 64(7): 1079-81, 1997 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-9381534

RESUMEN

BACKGROUND: Posttransplant lymphoproliferative disorders are generally associated with Epstein-Barr virus (EBV) and are of B cell origin. We report the case of a B-immunoblastic lymphoma that developed in a pretransplantation EBV-seronegative woman 4 months after kidney transplant from her HLA-haploidentical brother. The patient successfully underwent immunotoxin therapy for lymphoma and has been in remission for 36 months. METHODS: Latent EBV genomes were identified by polymerase chain reaction, and the purified amplification products were directly sequenced with [35S]dATP. RESULTS: Molecular analysis of the latent membrane protein (LMP)1 oncogene of EBV, which was expressed in most tumor cells, revealed a 30-base pair deletion. No wild-type LMP1 sequences were found. Analysis of peripheral blood mononuclear cells from the EBV-seropositive donor showed the presence of both the LMP1 deletion variant and the wild-type sequence. The LMP1 deletion variant and the wild-type sequence were also identified within peripheral blood mononuclear cells of the EBV-seroconverted kidney recipient 20 months after lymphoma therapy. CONCLUSION: This pattern is consistent with a natural growth advantage of B cells expressing the LMP1 deletion variant in the immunocompromised host.


Asunto(s)
Herpesvirus Humano 4 , Trasplante de Riñón , Linfoma de Células B/virología , Complicaciones Posoperatorias , Leucemia-Linfoma Linfoblástico de Células Precursoras/virología , Infecciones Tumorales por Virus/patología , Proteínas de la Matriz Viral/genética , Adulto , Sustitución de Aminoácidos , Femenino , Variación Genética , Glomerulonefritis por IGA/cirugía , Herpesvirus Humano 4/genética , Herpesvirus Humano 4/aislamiento & purificación , Humanos , Inmunotoxinas/uso terapéutico , Donadores Vivos , Linfoma de Células B/tratamiento farmacológico , Linfoma de Células B/patología , Mutación Puntual , Leucemia-Linfoma Linfoblástico de Células Precursoras/tratamiento farmacológico , Leucemia-Linfoma Linfoblástico de Células Precursoras/patología , Eliminación de Secuencia , Infecciones Tumorales por Virus/tratamiento farmacológico , Latencia del Virus
18.
Blood ; 87(3): 876-81, 1996 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-8562956

RESUMEN

This sequencing study of 17 acquired immunodeficiency syndrome-related lymphomas (9 primary brain, 8 systemic) and 8 human immunodeficiency virus-negative atypical lymphoproliferations expressing large amounts of the latent membrane protein 1 (LMP1) of Epstein-Barr virus was performed to characterize the carboxy terminal NF-kappa B activation domain of LMP1 at the molecular level in an immunocompromised host. In-frame deletions within the NF-kappa B activation domain were identified in all but 2 primary brain lymphomas, 4 systemic lymphomas, and 4 atypical lymphoproliferations, ie, in 60% of cases. In addition, non silent point mutations (range 1 to 5, mean 3.3) were detected in all cases. Although all changes occurred within the first 100 nucleotides of the carboxy terminal NF-kappa B activation domain--a critical sequence for the protein half-life--not a single point mutation was found in the remaining 62 nucleotides, necessary for malignant transformation. Such a clustering of nonrandom sequence variations, associated with a high oncoprotein expression in immunocompromised hosts, suggests that this part of the LMP1 oncogene behaves as a hypervariable region with natural selection of growth-promoting variants through prolongation of the protein half-life.


Asunto(s)
Transformación Celular Neoplásica/genética , Transformación Celular Viral/genética , Infecciones por Herpesviridae/virología , Herpesvirus Humano 4/genética , Linfoma Relacionado con SIDA/virología , Trastornos Linfoproliferativos/virología , FN-kappa B/metabolismo , Infecciones Tumorales por Virus/virología , Proteínas de la Matriz Viral/genética , Secuencia de Aminoácidos , Secuencia de Bases , Neoplasias Encefálicas/genética , Neoplasias Encefálicas/virología , Regulación Viral de la Expresión Génica , Seronegatividad para VIH , Semivida , Herpesvirus Humano 4/aislamiento & purificación , Herpesvirus Humano 4/fisiología , Humanos , Linfoma Relacionado con SIDA/genética , Trastornos Linfoproliferativos/genética , Datos de Secuencia Molecular , Mutación Puntual , Estructura Terciaria de Proteína , Selección Genética , Alineación de Secuencia , Eliminación de Secuencia , Proteínas de la Matriz Viral/química , Proteínas de la Matriz Viral/metabolismo
19.
Clin Lab Haematol ; 15(1): 21-32, 1993.
Artículo en Inglés | MEDLINE | ID: mdl-8472495

RESUMEN

A computer-based expert system is described which handles the output of the Technicon H1 in the haematology laboratory of a large teaching hospital. Using patient request data, analyser results, error and morphology flags, the expert system decides; whether to validate the main indices plus differential; whether a blood film is required for manual review; and which abnormal results require phoning to the requesting doctor. The results of this computer-assisted analysis are sent to a printer adjacent to the analyser. The print-out details any further action required of the operator before release of results to the main hospital computer, and serves as a log of all samples run on that analyser. Benefits of the expert system include greatly simplified interpretation of the large array of analyser flags, and consistency in sample handling for all operators over all shifts.


Asunto(s)
Sistemas Especialistas , Hematología/instrumentación , Interpretación de Imagen Asistida por Computador , Algoritmos , Presentación de Datos , Humanos , Programas Informáticos
20.
Am J Physiol Imaging ; 7(3-4): 220-9, 1992.
Artículo en Inglés | MEDLINE | ID: mdl-1343219

RESUMEN

This study describes the application of dynamic gadolinium-enhanced magnetic resonance (MR) imaging and MR angiography in the diagnosis and evaluation of the physiology of renal artery stenosis (RAS) before and after angioplasty. The MR imaging findings are discussed and compared to those of renal arteriography. MR time intensity curves of the renal cortex and medulla are obtained. Dynamic gadolinium-enhanced and angiographic MR data were abnormal in the setting of RAS and improved after angioplasty. The diagnosis of RAS could be made by visual inspection of MR dynamic images or MR angiographic images alone. Dynamic MR provides cross-sectional physiologic imaging data that compliments MR angiographic data. The role of dynamic gadolinium-enhanced MR in the evaluation of renovascular hypertension requires further investigation.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Obstrucción de la Arteria Renal/diagnóstico , Arteria Renal/patología , Adulto , Angiografía , Angioplastia , Medios de Contraste , Femenino , Gadolinio , Gadolinio DTPA , Humanos , Hipertensión Renovascular/diagnóstico , Compuestos Organometálicos , Ácido Pentético/análogos & derivados , Proyectos Piloto , Arteria Renal/diagnóstico por imagen , Obstrucción de la Arteria Renal/cirugía
SELECCIÓN DE REFERENCIAS