Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38632135

RESUMEN

BACKGROUND: Pulmonary vein (PV) occlusion is crucial for adequate lesion formation during cryoballoon-guided pulmonary vein isolation (CB-PVI). PV occlusion is usually confirmed by angiographies over the inflated balloon device. The aim of our study was to analyze the safety and efficacy of pressure waveform-based PV occlusion assessment during CB-PVI utilizing a novel fully integrated pressure analysis tool. METHODS: Consecutive patients with symptomatic atrial fibrillation (AF) scheduled for CB-PVI were prospectively enrolled for pressure waveform-based PV occlusion assessment. A patient cohort receiving conventional angiographies served as control group. Patients with common PV ostia were excluded. RESULTS: The study group consisted of 40 patients (16 females, mean age was 64.5 ± 9.7, 45% persistent AF). The control group consisted of 40 matched patients. All 160 PVs in the study group were successfully isolated without the use of additional venograms confirming PV occlusion. The mean procedure duration was 69 ± 12 min in the study group with a mean fluoroscopy duration of 11.5 ± 4.4 min. The mean contrast medium volume was 22 ± 9 ml in the study group and 36 ± 12 ml in the control group (p = 0.0001). Mean procedure duration, mean balloon temperatures, and mean ablation application durations did not differ significantly between the study and the control group. No periprocedural complications occurred. CONCLUSION: CB-PVI utilizing a fully integrated pressure waveform analysis tool to assess PV occlusion is feasible and safe and significantly reduces the amount of contrast medium without impact on procedural parameters and freedom from arrhythmia recurrence.

2.
Europace ; 26(3)2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38516791

RESUMEN

AIMS: Pulmonary vein isolation (PVI) for catheter ablation of atrial fibrillation (AF) is a time-demanding procedure. High-power short-duration (HPSD) ablation protocols and high-density mapping catheters have recently been introduced to clinical practice. We investigated the impact of high-density mapping and HPSD ablation protocols on procedural timing, efficacy, and safety by comparing different standardized set-ups. METHODS AND RESULTS: Three electrophysiology (EP) laboratory set-ups were analysed: (i) circular catheter for mapping and HPSD ablation with 30/35 W guided by an ablation index (AI); (ii) pentaspline catheter for mapping an HPSD ablation with 50 W guided by an AI; and (iii) pentaspline catheter for mapping and HPSD ablation with 90 W over 4 s using a novel ablation catheter. All patients underwent PVI without additional left atrial ablation strategies. Procedural data and operating intervals in the EP laboratory were systematically analysed. Three hundred seven patients were analysed (30/35 W AI: n = 102, 50 W AI: n = 102, 90 W/4 s: n = 103). Skin-to-skin times [105.3 ± 22.7 (30/35 W AI) vs. 81.4 ± 21.3 (50 W AI) vs. 69.5 ± 12.2 (90 W/4 s) min, P ≤ 0.001] and total laboratory times (132.8 ± 42.1 vs. 107.4 ± 25.7 vs. 95.2 ± 14.0 min, P < 0.001) significantly differed among the study groups. Laboratory interval analysis revealed significant shortening of mapping and ablation times. Arrhythmia-free survival after 12 months was not different among the study groups (log-rank P = 0.96). CONCLUSION: The integration of high-density mapping and HPSD protocols into an institutional AF ablation process resulted in reduced procedure times without compromising safety or efficacy.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Flujo de Trabajo , Atrios Cardíacos , Ablación por Catéter/efectos adversos , Venas Pulmonares/cirugía , Resultado del Tratamiento , Recurrencia
3.
Eur Heart J Case Rep ; 8(2): ytae057, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38348056

RESUMEN

Background: Catheter ablation is one of the most effective treatment options for patients with drug-refractory, scar-related monomorphic ventricular tachycardia (VT). In selected cases, catheter ablation also plays an important role in treatment of polymorphic VT (PMVT) and/or ventricular fibrillation (VF). Rarely, premature ventricular contractions (PVCs) originating from the Purkinje network can induce PMVT/VF. Ablation and elimination of these PVCs can prevent VF recurrences. Case summary: A 41-year-old patient with a history of orthotopic heart transplantation (HTX) 8 years before admission and newly diagnosed SARS-CoV-2 pneumonia was referred to our centre after experiencing several episodes of drug-refractory VF. An electrophysiological study showed ectopy-triggered VF originating from the anterior and posterior fascicles of the left bundle branch (LBB). Ablation of these PVCs from the LBB led to complete elimination of VF. A subcutaneous implantable cardioverter defibrillator was implanted as secondary prophylaxis. During the observation period of 6 months, no VF recurrence was observed. Conclusion: Identifying and eliminating the trigger (PVCs) can be life-saving and prevent VF in the specific cohort of HTX patients. High-density mapping using multipolar catheters with microelectrodes contributes significantly to our understanding of tachycardia mechanisms.

5.
Pacing Clin Electrophysiol ; 46(12): 1553-1564, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37885302

RESUMEN

BACKGROUND: Targeting individual sources identified during atrial fibrillation (AF) has been used as an ablation strategy with varying results. OBJECTIVE: Aim of this study was to evaluate the relationship between regions of interest (ROIs) from CARTOFINDER (CF) mapping and atrial cardiomyopathy from late gadolinium enhancement (LGE) cardiovascular magnetic resonance imaging (CMR). METHODS: Twenty consecutive patients underwent index catheter ablation for persistent AF (PERS AF). Pre-processed LGE CMR images were merged with the results from CF mapping to visualize harboring regions for focal and rotational activities. Atrial cardiomyopathy was classified based on the four Utah stages. RESULTS: Procedural success was achieved in all patients (n = 20, 100%). LGE CMR revealed an intermediate amount of 21.41% ± 6.32% for LA fibrosis. ROIs were identified in all patients (mean no ROIs per patient n = 416.45 ± 204.57). A tendency towards a positive correlation between the total amount of atrial cardiomyopathy and the total number of ROIs per patient (regression coefficient, ß = 10.86, p = .15) was observed. The degree of fibrosis and the presence of ROIs per segment showed no consistent spatial correlation (posterior: ß = 0.36, p-value (p) = .24; anterior: ß = -0.08, p = .54; lateral: ß = 0.31, p = 39; septal: ß = -0.12; p = .66; right PVs: ß = 0.34, p = .27; left PVs: ß = 0.07, p = .79; LAA: ß = -0.91, p = .12). 12 months AF-free survival was 70% (n = 14) after ablation. CONCLUSION: The presence of ROIs from CF mapping was not directly associated with the extent and location of fibrosis. Further studies evaluating the relationship between focal and rotational activity and atrial cardiomyopathy are mandatory.


Asunto(s)
Fibrilación Atrial , Cardiomiopatías , Ablación por Catéter , Humanos , Ablación por Catéter/métodos , Medios de Contraste , Fibrosis , Gadolinio , Atrios Cardíacos , Imagen por Resonancia Magnética/métodos
7.
J Interv Card Electrophysiol ; 66(9): 2125-2133, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37145294

RESUMEN

BACKGROUND: Cryoballoon (CB)-guided pulmonary vein isolation (PVI) is an established treatment for atrial fibrillation (AF). This observational study aimed to assess the role of individual anatomical characteristics to predict long-term freedom from arrhythmia recurrence after CB-guided PVI for paroxysmal AF (PAF). METHODS: Three hundred fifty three consecutive patients (58 ± 11 years, 56% males), undergoing PVI between 2012 and 2018 were analysed. Individual pulmonary vein (PV) anatomy was assessed using preprocedural cardiac magnetic resonance imaging (MRI). For each PV, the cross-sectional area (CSA) was calculated. The impact of PV characteristics and CSA on long-term AF-free survival was evaluated. RESULTS: Acute PVI was achieved in all patients. Two hundred twenty-three patients (63%) had a normal PV anatomy (2 left- and 2 right-sided PV). Variant PV anatomy was present in 130 patients (37%). During the observation period of 48 months, AF-recurrence was documented in 167 patients (47 %). Patients with AF-recurrence presented with significantly enlarged right-sided PVs and left superior PVs (LSPVs) (p < 0.001). The presence of left common PVs (LCPVs) (n = 75, Log-rank p < 0.001) as well as right variant PVs (n = 35, Log rank p < 0.001) was associated with a significantly impaired long-term AF-free survival rate as compared to patients with normal PV characteristics. CONCLUSION: Variant PV anatomy is a good predictor for AF-recurrence. A correlation between an enlarged CSA of right-sided PVs as well as LSPVs and AF-recurrence was documented.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Masculino , Humanos , Femenino , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Criocirugía/métodos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Imagen por Resonancia Magnética , Resultado del Tratamiento , Ablación por Catéter/métodos , Recurrencia
8.
Pacing Clin Electrophysiol ; 46(7): 714-716, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37247251

RESUMEN

BACKGROUND: Pulsed field ablation (PFA) results in unique lesion formation, but there is lack of in-vivo validation in terms of scar formation following atrial fibrillation (AF) ablation. OBJECTIVE: We aimed to access atrial lesion formation based on late gadolinium enhancement (LGE) cardiovascular magnetic resonance imaging (CMR) following PFA for pulmonary vein (PV) and posterior wall isolation (PWI). METHODS: AF ablation was performed in 10 patients using a 31 mm pentaspline PFA catheter. After pulmonary vein isolation (PVI; n = 8 PFA-applications/ PV; n = 4 in basket and n = 4 in flower configuration), another eight applications in flower configuration were conducted for concomitant PWI. Patients underwent LGE CMR 3 months after ablation aiming for quantification of left atrial (LA) scar. RESULTS: Acute procedural success was achieved in all patients. Mean procedure duration was 62 ± 7 min. and mean LA dwell time of the PFA catheter was 13 ± 2 min. Mean post ablation total LA scar burden was 8.1 ± 2.1% and mean scar width was 12.8 ± 2.1 mm. At the posterior LA, 22.6 ± 2.2% of the anatomical segment resulted in chronic scar tissue, concentrated at the PW. Postablation CMR found no evidence for PV stenosis or collateral damage of adjacent structures. At 7 months of follow-up, 9/10 patients (90%) were free from arrhythmia recurrence. CONCLUSION: PFA for AF resulted in durable and transmural atrial scar tissue at the PVs and PW. LGE CMR found a very homogeneous and contiguous lesion pattern with no signs for collateral damage.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Cicatriz/cirugía , Medios de Contraste , Venas Pulmonares/cirugía , Gadolinio , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Atrios Cardíacos/patología , Ablación por Catéter/métodos , Resultado del Tratamiento , Recurrencia
9.
Heart Vessels ; 38(7): 984-991, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36786857

RESUMEN

A new automated vector-based mapping algorithm (AMA) for 3-dimensional (3D) mapping has been introduced. The aim of this study was to present our experience using AMA to recognize additional catheter ablation targets in patients with ventricular arrhythmias (VA). A total of 16 patients (ICM; ischemic cardiomyopathy, n = 6; NICM; non-ischemic cardiomyopathy n = 10) suffering from VA underwent catheter ablation. Following bipolar voltage mapping, AMA was utilized to reveal zones of decelerated conduction velocity vectors (CVV) and this information was superimposed onto the 3D reconstructions and compared with the presence of scar. Mapping time was 28.1 ± 10 min for the endocardial reconstruction of the left ventricle (LV) and 17 ± 5.4 min for the epicardium (n = 6 patients). The mean area of LV low voltage was 13.9 ± 15% (endocardial) and 11.9 ± 5.7% (epicardial). Decelerating CVV zones were revealed in all patients (mean conduction velocity threshold of 39.3 ± 13%). Sustained VA have been terminated through ablation and substrate modification was performed in all patients. Correlation between the presence of CVV deceleration zones and areas of abnormal low voltage from bipolar mapping was revealed in only 37.5% of patients, but there was good correlation between scar from unipolar voltage mapping and the presence of CCV deceleration zones (94%; p = 0.008). The novel AMA may improve the understanding of individual VA substrates due to the visualization of decelerated CVV zones and their correlation with abnormal low voltage predominantly from unipolar mapping.


Asunto(s)
Cardiomiopatías , Ablación por Catéter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Cicatriz/cirugía , Ventrículos Cardíacos , Arritmias Cardíacas , Ablación por Catéter/métodos
10.
Cardiol J ; 30(1): 36-43, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36588311

RESUMEN

BACKGROUND: The DiamondTemp (DT) radiofrequency ablation (RFA) catheter has been introduced as a new tool for atrial fibrillation (AF) ablation. The new technology allows for temperature-controlled irrigated ablation and real-time lesion assessment. Recently, the EnSite X mapping system became commercially available allowing for omnipolar and ultra-high-resolution mapping. We aimed to assess the feasibility of the new DT RFA catheter in performing AF ablation procedures in conjunction with the novel EnSite X system under routine clinical conditions. METHODS: We analyzed data from 10 consecutive patients who underwent AF ablation using the DT RFA catheter guided by EnSite X. Procedural data and short-term follow-up were assessed as well as potential technical issues. RESULTS: Nine out of 10 patients underwent de-novo pulmonary vein isolation (PVI), and 1 patient underwent repeat ablation. First-pass isolation was observed in 7/10 patients. Total procedure duration (skin-to-skin) was 88.9 ± 30.1 min, and left atrium dwell time was 70 ± 22.3 min. The mean number of RF applications needed for PVI and additional ablation was 70.52 ± 26.70. The HD Grid SE mapping catheter was utilized in 8 patients and the Advisor SE in 2 patients. Bidirectional block of the applied lines was achieved in all patients. No steam pops were observed, and no intraprocedural complications occurred. CONCLUSIONS: This first clinical series demonstrated that temperature-controlled irrigated ablation in combination with the novel omnipolar and high-resolution mapping system resulted in rapid, efficient, and durable lesion formation under routine clinical conditions. Randomized controlled trials are needed to elucidate the impact on lesion formation, long-term outcomes, and reproducibility of our initial findings.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Reproducibilidad de los Resultados , Resultado del Tratamiento , Diseño de Equipo , Catéteres , Ablación por Catéter/métodos , Venas Pulmonares/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA