Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
IEEE Trans Med Imaging ; 40(3): 1007-1020, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33315555

RESUMEN

CT scan by use of a beam-filter placed between the x-ray source and the patient allows a single-scan low-dose dual-energy imaging with a minimal hardware modification to the existing CT systems. We have earlier demonstrated the feasibility of such imaging method with a multi-slit beam-filter reciprocating along the direction perpendicular to the CT rotation axis in a cone-beam CT system. However, such method would face mechanical challenges when the beam-filter is supposed to cooperate with a fast-rotating gantry in a diagnostic CT system. In this work, we propose a new scanning method and associated image reconstruction algorithm that can overcome these challenges. We propose to slide a beam-filter that has multi-slit structure with its slits being at a slanted angle with the CT gantry rotation axis during a scan. A streaky pattern would show up in the sinogram domain as a result. Using a notch filter in the Fourier domain of the sinogram, we removed the streaks and reconstructed an image by use of the filtered-backprojection algorithm. The remaining image artifacts were suppressed by applying l0 norm based smoothing. Using this image as a prior, we have reconstructed low- and high-energy CT images in the iterative reconstruction framework. An image-based material decomposition then followed. We conducted a simulation study to test its feasibility using the XCAT phantom and also an experimental study using the Catphan phantom, a head phantom, an iodine-solution phantom, and a monkey in anesthesia, and showed its successful performance in image reconstruction and in material decomposition.


Asunto(s)
Algoritmos , Tomografía Computarizada por Rayos X , Artefactos , Tomografía Computarizada de Haz Cónico , Cabeza/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador , Fantasmas de Imagen
2.
Phys Med Biol ; 51(6): N99-107, 2006 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-16510949

RESUMEN

In this paper, the development of compact transmission soft x-ray microscopy (XM) with sub-50 nm spatial resolution for biomedical applications is described. The compact transmission soft x-ray microscope operates at lambda = 2.88 nm (430 eV) and is based on a tabletop regenerative x-ray source in combination with a tandem ellipsoidal condenser mirror for sample illumination, an objective micro zone plate and a thinned back-illuminated charge coupled device to record an x-ray image. The new, compact x-ray microscope system requires the fabrication of proper x-ray optical devices in order to obtain high-quality images. For an application-oriented microscope, the alignment procedure is fully automated via computer control through a graphic user interface. In imaging studies using our compact XM system, a gold mesh image was obtained with 45 nm resolution at x580 magnification and 1 min exposure. Images of a biological sample (Coscinodiscus oculoides) were recorded.


Asunto(s)
Microanálisis por Sonda Electrónica/métodos , Rayos X , Diatomeas/ultraestructura , Procesamiento de Imagen Asistido por Computador , Rayos Láser , Microscopía , Microscopía Electrónica de Transmisión/métodos , Dispositivos Ópticos , Fotones , Programas Informáticos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...