Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Anal Chem ; 94(37): 12798-12806, 2022 09 20.
Artículo en Inglés | MEDLINE | ID: mdl-36070604

RESUMEN

Detection of iron at the subcellular level in order to gain insights into its transport, storage, and therapeutic prospects to prevent cytotoxic effects of excessive iron accumulation is still a challenge. Nanoscale magnetic sector secondary ion mass spectrometry (SIMS) is an excellent candidate for subcellular mapping of elements in cells since it provides high secondary ion collection efficiency and transmission, coupled with high-lateral-resolution capabilities enabled by nanoscale primary ion beams. In this study, we developed correlative methodologies that implement SIMS high-resolution imaging technologies to study accumulation and determine subcellular localization of iron in alveolar macrophages. We employed transmission electron microscopy (TEM) and backscattered electron (BSE) microscopy to obtain structural information and high-resolution analytical tools, NanoSIMS and helium ion microscopy-SIMS (HIM-SIMS) to trace the chemical signature of iron. Chemical information from NanoSIMS was correlated with TEM data, while high-spatial-resolution ion maps from HIM-SIMS analysis were correlated with BSE structural information of the cell. NanoSIMS revealed that iron is accumulating within mitochondria, and both NanoSIMS and HIM-SIMS showed accumulation of iron in electrolucent compartments such as vacuoles, lysosomes, and lipid droplets. This study provides insights into iron metabolism at the subcellular level and has future potential in finding therapeutics to reduce the cytotoxic effects of excessive iron loading.


Asunto(s)
Hierro , Macrófagos Alveolares , Helio , Pulmón , Espectrometría de Masa de Ion Secundario/métodos
2.
ACS Nano ; 14(4): 4316-4325, 2020 04 28.
Artículo en Inglés | MEDLINE | ID: mdl-32239916

RESUMEN

Mass spectrometry imaging is a field that promises to become a mainstream bioanalysis technology by allowing the combination of single-cell imaging and subcellular quantitative analysis. The frontier of single-cell imaging has advanced to the point where it is now possible to compare the chemical contents of individual organelles in terms of raw or normalized ion signal. However, to realize the full potential of this technology, it is necessary to move beyond this concept of relative quantification. Here we present a nanoSIMS imaging method that directly measures the absolute concentration of an organelle-associated, isotopically labeled, pro-drug directly from a mass spectrometry image. This is validated with a recently developed nanoelectrochemistry method for single organelles. We establish a limit of detection based on the number of isotopic labels used and the volume of the organelle of interest, also offering this calculation as a web application. This approach allows subcellular quantification of drugs and metabolites, an overarching and previously unmet goal in cell science and pharmaceutical development.


Asunto(s)
Orgánulos , Espectrometría de Masa de Ion Secundario , Diagnóstico por Imagen
3.
J Chromatogr A ; 1621: 461048, 2020 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-32204879

RESUMEN

The impact of eluent components added to improve separation performance in supercritical fluid chromatography was systematically, and fundamentally, investigated. The model system comprised basic pharmaceuticals as solutes and eluents containing an amine (i.e., triethylamine, diethylamine, or isopropylamine) as additive with MeOH as the co-solvent. First, an analytical-scale study was performed, systematically investigating the impact of the additives/co-solvent on solute peak shapes and retentions, using a design of experiments approach; here, the total additive concentration in the eluent ranged between 0.021 and 0.105 % (v/v) and the MeOH fraction in the eluent between 16 and 26 % (v/v). The co-solvent fraction was found to be the most efficient tool for adjusting retentions, whereas the additive fraction was the prime tool for improving column efficiency and peak analytical performance. Next, the impacts of the amine additives on the shapes of the so-called overloaded solute elution profiles were investigated. Two principal types of preparative peak deformations appeared and were investigated in depth, analyzed using computer simulation with mechanistic modeling. The first type of deformation was due to the solute eluting too close to the additive perturbation peak, resulting in severe peak deformation caused by co-elution. The second type of deformation was also due to additive-solute interactions, but here the amine additives acted as kosmotropic agents, promoting the multilayer adsorption to the stationary phase of solutes with bulkier aryl groups.


Asunto(s)
Cromatografía con Fluido Supercrítico/métodos , Adsorción , Simulación por Computador , Dietilaminas/química , Etilaminas/química , Propilaminas/química , Solventes/química
4.
Sci Rep ; 9(1): 10060, 2019 07 11.
Artículo en Inglés | MEDLINE | ID: mdl-31296897

RESUMEN

Chronic obstructive pulmonary disease (COPD) is a debilitating lung disease that is currently the third leading cause of death worldwide. Recent reports have indicated that dysfunctional iron handling in the lungs of COPD patients may be one contributing factor. However, a number of these studies have been limited to the qualitative assessment of iron levels through histochemical staining or to the expression levels of iron-carrier proteins in cells or bronchoalveolar lavage fluid. In this study, we have used time of flight secondary ion mass spectrometry (ToF-SIMS) to visualize and relatively quantify iron accumulation in lung tissue sections of healthy donors versus severe COPD patients. An IONTOF 5 instrument was used to perform the analysis, and further multivariate analysis was used to analyze the data. An orthogonal partial least squares discriminant analysis (OPLS-DA) score plot revealed good separation between the two groups. This separation was primarily attributed to differences in iron content, as well as differences in other chemical signals possibly associated with lipid species. Further, relative quantitative analysis revealed twelve times higher iron levels in lung tissue sections of COPD patients when compared to healthy donors. In addition, iron accumulation observed within the cells was heterogeneously distributed, indicating cellular compartmentalization.


Asunto(s)
Hierro/metabolismo , Pulmón/metabolismo , Macrófagos/patología , Enfermedad Pulmonar Obstructiva Crónica/metabolismo , Espectrometría de Masa de Ion Secundario/métodos , Análisis Discriminante , Humanos , Pulmón/patología , Enfermedad Pulmonar Obstructiva Crónica/patología
5.
J Chromatogr A ; 1568: 177-187, 2018 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-30072233

RESUMEN

We investigated and compared the robustness of supercritical fluid chromatography (SFC) separations of the peptide gramicidin, using either isocratic or gradient elution. This was done using design of experiments in a design space of co-solvent fraction, water mass fraction in co-solvent, pressure, and temperature. The density of the eluent (CO2-MeOH-H2O) was experimentally determined using a Coriolis mass flow meter to calculate the volumetric flow rate required by the design. For both retention models, the most important factor was the total co-solvent fraction and water mass fraction in co-solvent. Comparing the elution modes, we found that gradient elution was more than three times more robust than isocratic elution. We also observed a relationship between the sensitivity to changes and the gradient steepness and used this to draw general conclusions beyond the studied experimental system. To test the robustness in a practical context, both the isocratic and gradient separations were transferred to another laboratory. The gradient elution was highly reproducible between laboratories, whereas the isocratic system was not. Using measurements of the actual operational conditions (not the set system conditions), the isocratic deviation was quantitatively explained using the retention model. The findings indicate the benefits of using gradient elution in SFC as well as the importance of measuring the actual operational conditions to be able to explain observed differences between laboratories when conducting method transfer.


Asunto(s)
Cromatografía con Fluido Supercrítico/métodos , Péptidos/aislamiento & purificación , Simulación por Computador , Gramicidina/aislamiento & purificación , Presión , Solventes/química , Temperatura , Agua
6.
J Chromatogr A ; 1496: 141-149, 2017 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-28366564

RESUMEN

Strangely shaped overloaded bands were recently reported using a standard supercritical fluid chromatographic system comprising a diol column as the stationary phase and carbon dioxide with methanol as the mobile phase. Some of these overloaded elution profiles appeared strongly deformed and even had "anti-Langmuirian" shapes although their solute compounds had "Langmuirian" adsorption. To obtain a more complete understanding of the generality of these effects, the investigation was expanded to cover also other common co-solvents, such as ethanol, 2-propanol, and acetonitrile, as well as various stationary phase materials, such as silica, and 2-ethylpyridine. From this expanded study it could be confirmed that the effects of deformed overloaded solute band shapes, due to co-solvent adsorption, is general phenomena in supercritical fluid chromatographic. It could also be concluded that these effects as well as previously observed "solvent effects" or "plug effects" are entirely due to competition between the solute and solvent molecules for the adsorption sites on the stationary phase surface. Finally, guidelines were given for how to evaluate the risk of deformations occurring for a given solvent-column combination, based simply on testing retention times of solutes and co-solvent.


Asunto(s)
Cromatografía con Fluido Supercrítico/métodos , Solventes/química , Adsorción , Dióxido de Carbono/química , Cromatografía con Fluido Supercrítico/instrumentación , Metanol/química
7.
J Chromatogr A ; 1496: 80-91, 2017 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-28363419

RESUMEN

The adsorption mechanism for three peptides was studied under overloaded conditions through adsorption isotherm measurements in the presence of an ion-pairing reagent, trifluoroacetic acid (TFA), on an end-capped C18-bonded stationary phase. The overall aim of the study was to obtain a better understanding of how the acetonitrile and the TFA fractions in the eluent affected the overloaded elution profiles and the selectivity between peptides using mechanistic modelling and multivariate design of experiments. When studying the effect of TFA, direct evidence for ion pair formation between a peptide and TFA in acetonitrile-water solutions was provided by fluorine-proton nuclear Overhauser NMR enhancement experiments and the adsorption of TFA on the stationary phase was measured by frontal analysis. The adsorption isotherms for each peptide were then determined by the inverse method at eight TFA concentrations ranging from 2.6mM to 37.3mM (0.02-0.29vol-%) in isocratic elution. The equilibrium between the peptide ion and the peptide-TFA complex was modelled by coupling the mass-balance to reaction kinetics and determining separate adsorption isotherms for the two species. We found that a Langmuir isotherm described the elution profile of peptide-TFA complex well while the peptide ion was described by a bi-Langmuir adsorption isotherm since it exhibited strong secondary interactions. The elution profiles had an unfavorable shape at low TFA concentrations consisting of a spike in their front and a long tailing rear due to the secondary interactions for the peptide ion having very low saturation capacity. The acetonitrile dependence on the adsorption isotherms was studied by determination of adsorption isotherms directly from elution profiles obtained in gradient elution which enabled a broad acetonitrile interval to be studied. Here, it was found that the column saturation capacity was quickly reached at very low acetonitrile fractions and that there were significant variations in adsorption with the molecular weight. Finally, practical implications for method development are discussed based on an experimental design where gradient slope and TFA concentrations are used as factors.


Asunto(s)
Cromatografía de Fase Inversa/métodos , Péptidos/química , Péptidos/aislamiento & purificación , Acetonitrilos/química , Adsorción , Iones/química , Cinética , Espectroscopía de Resonancia Magnética , Ácido Trifluoroacético/química
8.
Drug Discov Today ; 22(1): 133-139, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27693710

RESUMEN

A strategy for large-scale chiral resolution is illustrated by the isolation of pure enantiomer from a 5kg batch. Results from supercritical fluid chromatography will be presented and compared with normal phase liquid chromatography. Solubility of the compound in the supercritical mobile phase was shown to be the limiting factor. To circumvent this, extraction injection was used but shown not to be efficient for this compound. Finally, a method for chiral resolution by crystallization was developed and applied to give diastereomeric salt with an enantiomeric excess of 99% at a 91% yield. Direct access to a diverse separation tool box will be shown to be essential for solving separation problems in the most cost and time efficient way.


Asunto(s)
Cromatografía con Fluido Supercrítico/métodos , Descubrimiento de Drogas/métodos , Preparaciones Farmacéuticas/aislamiento & purificación , Cristalización , Estructura Molecular , Preparaciones Farmacéuticas/química , Solubilidad , Estereoisomerismo
9.
J Chromatogr A ; 1468: 200-208, 2016 Oct 14.
Artículo en Inglés | MEDLINE | ID: mdl-27641721

RESUMEN

In supercritical fluid chromatography (SFC) the mobile phase comprises of carbon dioxide (CO2) as main solvent and smaller amounts of an organic polar solvent (often an alcohol) as co-solvent. The co-solvent is considered to function by changing the overall polarity of the eluent, i.e. by acting as a "modifier". However, recent studies indicate that the co-solvent methanol can also adsorb to some common SFC stationary phases. Hence, the co-solvent should also be able to function as an "adsorbing additive", i.e. an eluent component that competes with the injected solutes about the stationary phase surface. In this study it was found by fitting different mechanistic models to systematic experimental data, that the co-solvent methanol can have both functions: at low co-solvent fractions, methanol acts as an additive whereas at larger fractions it acts as a modifier. Moreover, it was found that when the co-solvent adsorbs more strongly to the stationary phase than the solute, "bizarre" deformations of the preparative band shapes can occur. This is illustrated by a solute that converts from a normal "Langmuirian" band shape to an "anti-Langmuirian" shape when changing from neat carbon dioxide (CO2) to an eluent containing co-solvent. This peak shape transition is dependent on both (i) the relative retention of the solute and co-solvent to the stationary phase in eluent containing neat CO2 and on (ii) the relative retention of the additive perturbation peak and the solute peak in eluent containing also co-solvent.


Asunto(s)
Cromatografía con Fluido Supercrítico/métodos , Solventes/química , Adsorción , Dióxido de Carbono/química , Metanol/química
10.
J Chromatogr A ; 1442: 129-39, 2016 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-26979267

RESUMEN

Surface excess adsorption isotherms of methanol on a diol silica adsorbent were measured in supercritical fluid chromatography (SFC) using a mixture of methanol and carbon dioxide as mobile phase. The tracer pulse method was used with deuterium labeled methanol as solute and the tracer peaks were detected using APCI-MS over the whole composition range from neat carbon dioxide to neat methanol. The results indicate that a monolayer (4Å) of methanol is formed on the stationary phase. Moreover, the importance of using the set or the actual methanol fractions and volumetric flows in SFC was investigated by measuring the mass flow respective pressure and by calculations of the actual volume fraction of methanol. The result revealed a significant difference between the value set and the actually delivered volumetric methanol flow rate, especially at low modifier fractions. If relying only on the set methanol fraction in the calculations, the methanol layer thickness should in this system be highly overestimated. Finally, retention times for a set of solutes were measured and related to the findings summarized above concerning methanol adsorption. A strongly non-linear relationship between the logarithms of the retention factors and the modifier fraction in the mobile phase was revealed, prior to the established monolayer. At modifier fractions above that required for establishment of the methanol monolayer, this relationship turns linear which explains why the solute retention factors are less sensitive to changes in modifier content in this region.


Asunto(s)
Cromatografía con Fluido Supercrítico/normas , Metanol/metabolismo , Adsorción , Alcoholes/química , Dióxido de Carbono/química , Metanol/química , Presión , Dióxido de Silicio/química
11.
J Chromatogr A ; 1425: 280-6, 2015 Dec 18.
Artículo en Inglés | MEDLINE | ID: mdl-26615709

RESUMEN

An approach for reliable transfer from analytical to preparative scale supercritical fluid chromatography was evaluated. Here, we accounted for the conditions inside the columns as well as to the fact that most analytical instruments are volume-controlled while most preparative scale units are mass-controlled. The latter is a particular problem when performing pilot scale experiments and optimizations prior to scaling up to production scale. This was solved by measuring the mass flow, the pressure and the temperature on the analytical unit using external sensors. Thereafter, it was revealed with a design of experiments approach that the methanol fraction and the pressure are the two most important parameters to control for preserved retention throughout the scale-up; for preserved selectivity the temperature was most important in this particular system. Using this approach, the resulting chromatograms from the preparative unit agreed well with those from the analytical unit while keeping the same column length and particles size. A brief investigation on how the solute elution volume varies with the volumetric flow rate revealed a complex dependency on pressure, density and apparent methanol content. Since the methanol content is a parameter of great importance to control during the scale up, we must be careful when changing operational and column design conditions which generates deviations in pressure, density and methanol content between different columns.


Asunto(s)
Cromatografía con Fluido Supercrítico/métodos , Metanol , Tamaño de la Partícula , Presión , Solventes , Temperatura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...