Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 10(1): 9150, 2020 06 04.
Artículo en Inglés | MEDLINE | ID: mdl-32499579

RESUMEN

Particulate matter (PM) air pollution is a central concern for public health. Current legislation relies on a mass concentration basis, despite broad acceptance that mass alone is insufficient to capture the complexity and toxicity of airborne PM, calling for additional and more comprehensive measurement techniques. We study to what extent scanning electron microscopy coupled with energy dispersive X-ray spectroscopy (SEM/EDS) can be applied for physicochemical characterization of complex aerosols, and investigate its potential for separating particle properties on a single particle basis, even for nanosized particles. SEM/EDS analysis is performed on impactor samples of laboratory generated aerosols, consisting of either NaCl, Halloysite fibers, soot-like Printex90 agglomerates, or their combination. The analysis is automated and performed as EDS maps, covering a statistically relevant number of particles, with analysis times of approximately one hour/sample. Derived size distributions are compared to scanning mobility particle sizer (SMPS) and electric low-pressure impactor (ELPI) results. A method is presented to estimate airborne number concentrations and size distributions directly from SEM results, within a factor 10 of SMPS and ELPI outcomes. A classification scheme is developed based on elemental composition, providing class-specific information with individual particle statistics on shape, size, and mixing state. This can identify primary particles for source apportionment and enables easy distinction between fibrous and dense particle classes, e.g. for targeted risk assessments. Overall, the SEM/EDS analysis provides a more detailed physicochemical characterization of PM than online measurements, e.g. SMPS and ELPI. The method has the potential to improve assessments of PM exposure and risk, and facilitates source identification, even without prior knowledge at sampling.

2.
Microsc Microanal ; 26(3): 373-386, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32475372

RESUMEN

Scanning electron microscopy, coupled with energy-dispersive X-ray spectroscopy (EDS), is a powerful tool used in many scientific fields. It can provide nanoscale images, allowing size and morphology measurements, as well as provide information on the spatial distribution of elements in a sample. This study compares the capabilities of a traditional EDS detector with a recently developed annular EDS detector when analyzing electron transparent and beam-sensitive NaCl particles on a TEM grid. The optimal settings for single particle analysis are identified in order to minimize beam damage and optimize sample throughput via the choice of acceleration voltage, EDS acquisition time, and quantification model. Here, a linear combination of two models is used to bridge results for particle sizes, which are neither bulk nor sufficiently thin to assume electron transparent. Additionally, we show that the increased count rate obtainable with the annular detector enables mapping as a viable analysis strategy compared with feature detection methods, which only scan segmented regions. Finally, we discuss advantages and disadvantages of the two analysis strategies.

4.
Sci Rep ; 9(1): 8093, 2019 05 30.
Artículo en Inglés | MEDLINE | ID: mdl-31147577

RESUMEN

Air pollution is one of the major contributors to the global burden of disease, with particulate matter (PM) as one of its central concerns. Thus, there is a great need for exposure and risk assessments associated with PM pollution. However, current standard measurement techniques bring no knowledge of particle composition or shape, which have been identified among the crucial parameters for toxicology of inhaled particles. We present a method for collecting aerosols via impaction directly onto Transmission Electron Microscopy (TEM) grids, and based on the measured impactor collection efficiency and observed impact patterns we establish a reproducible imaging routine for automated Scanning Electron Microscopy (SEM) analysis. The method is validated by comparison to scanning mobility particle sizer (SMPS) measurements, where a good agreement is found between the particle size distributions (PSD), ensuring a representative description of the sampled aerosol. We furthermore determine sampling conditions for achieving optimal particle coverage on the TEM grids, allowing for a statistical analysis. In summary, the presented method can provide not only a representative PSD, but also detailed statistics on individual particle geometries. If coupled with Energy-dispersive X-ray spectroscopy (EDS) analysis elemental compositions can be assessed as well. This makes it possible to categorize particles both according to size and shape e.g. round and fibres, or agglomerates, as well as classify them based on their elemental composition e.g. salt, soot, or metals. Combined this method brings crucial knowledge for improving the foundation for PM risk assessments on workplaces and in ambient conditions with complex aerosol pollution.

5.
Part Fibre Toxicol ; 16(1): 23, 2019 06 11.
Artículo en Inglés | MEDLINE | ID: mdl-31182125

RESUMEN

BACKGROUND: Little is known about the exposure levels and adverse health effects of occupational exposure to airplane emissions. Diesel exhaust particles are classified as carcinogenic to humans and jet engines produce potentially similar soot particles. Here, we evaluated the potential occupational exposure risk by analyzing particles from a non-commercial airfield and from the apron of a commercial airport. Toxicity of the collected particles was evaluated alongside NIST standard reference diesel exhaust particles (NIST2975) in terms of acute phase response, pulmonary inflammation, and genotoxicity after single intratracheal instillation in mice. RESULTS: Particle exposure levels were up to 1 mg/m3 at the non-commercial airfield. Particulate matter from the non-commercial airfield air consisted of primary and aggregated soot particles, whereas commercial airport sampling resulted in a more heterogeneous mixture of organic compounds including salt, pollen and soot, reflecting the complex occupational exposure at an apron. The particle contents of polycyclic aromatic hydrocarbons and metals were similar to the content in NIST2975. Mice were exposed to doses 6, 18 and 54 µg alongside carbon black (Printex 90) and NIST2975 and euthanized after 1, 28 or 90 days. Dose-dependent increases in total number of cells, neutrophils, and eosinophils in bronchoalveolar lavage fluid were observed on day 1 post-exposure for all particles. Lymphocytes were increased for all four particle types on 28 days post-exposure as well as for neutrophil influx for jet engine particles and carbon black nanoparticles. Increased Saa3 mRNA levels in lung tissue and increased SAA3 protein levels in plasma were observed on day 1 post-exposure. Increased levels of DNA strand breaks in bronchoalveolar lavage cells and liver tissue were observed for both particles, at single dose levels across doses and time points. CONCLUSIONS: Pulmonary exposure of mice to particles collected at two airports induced acute phase response, inflammation, and genotoxicity similar to standard diesel exhaust particles and carbon black nanoparticles, suggesting similar physicochemical properties and toxicity of jet engine particles and diesel exhaust particles. Given this resemblance as well as the dose-response relationship between diesel exhaust exposure and lung cancer, occupational exposure to jet engine emissions at the two airports should be minimized.


Asunto(s)
Contaminantes Ocupacionales del Aire/toxicidad , Aeropuertos , Daño del ADN , Pulmón/efectos de los fármacos , Material Particulado/toxicidad , Hidrocarburos Policíclicos Aromáticos/toxicidad , Contaminantes Ocupacionales del Aire/análisis , Contaminantes Ocupacionales del Aire/farmacocinética , Animales , Biomarcadores/sangre , Líquido del Lavado Bronquioalveolar/citología , Femenino , Pulmón/metabolismo , Pulmón/ultraestructura , Ratones Endogámicos C57BL , Exposición Profesional/efectos adversos , Exposición Profesional/análisis , Material Particulado/análisis , Material Particulado/farmacocinética , Hidrocarburos Policíclicos Aromáticos/análisis , Hidrocarburos Policíclicos Aromáticos/farmacocinética , Proteína Amiloide A Sérica/análisis , Factores de Tiempo , Distribución Tisular
6.
J Colloid Interface Sci ; 553: 71-82, 2019 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-31200231

RESUMEN

Cellulose nanocrystals (CNCs) are promising bio-derived nanomaterials for the bottom-up fabrication of biomedical constructs. In this report, dicarboxylic acid-functionalized CNC (DCC) was functionalized with arginylglycylaspartic acid (RGD) tripeptide as a motif for improved cell adhesion and targeting. The product (DCC-RGD) self-assembled into a more elongated nanofibrillar structure through lateral and end-to-end association. When added into poly(ethylene imine) (PEI)/pDNA polyplex solution, nanocelluloses interacted electrostatically with positively charged polyplexes without affecting their integrity. The constructs were tested for their potentials as non-viral transfection reagents. Cell viability and transfection efficiency of fibroblast NIH3T3 cells were monitored as a function of CNC concentration where, in general, viability increased as the CNC concentration increased, and transfection efficiency could be optimized. Using wild-type MDCK and αV-knockout MDCK cells, the construct was able to provide targeted uptake of polyplexes. The findings have potential applications, for example, cell-selective in vitro or ex vivo transfection of autologous mesenchymal stem cells for cell therapy, or bottom-up design of future innovative biomaterials.


Asunto(s)
Celulosa/química , ADN/química , Iminas/química , Nanofibras/química , Nanopartículas/química , Oligopéptidos/química , Polietilenos/química , Animales , Supervivencia Celular/efectos de los fármacos , Células Cultivadas , Ácidos Dicarboxílicos/química , Ácidos Dicarboxílicos/farmacología , Perros , Relación Dosis-Respuesta a Droga , Células de Riñón Canino Madin Darby , Ratones , Estructura Molecular , Células 3T3 NIH , Oligopéptidos/farmacología , Tamaño de la Partícula , Plásmidos , Propiedades de Superficie
7.
Sci Total Environ ; 668: 13-24, 2019 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-30851679

RESUMEN

Poor air quality is a leading contributor to the global disease burden and total number of deaths worldwide. Humans spend most of their time in built environments where the majority of the inhalation exposure occurs. Indoor Air Quality (IAQ) is challenged by outdoor air pollution entering indoors through ventilation and infiltration and by indoor emission sources. The aim of this study was to understand the current knowledge level and gaps regarding effective approaches to improve IAQ. Emission regulations currently focus on outdoor emissions, whereas quantitative understanding of emissions from indoor sources is generally lacking. Therefore, specific indoor sources need to be identified, characterized, and quantified according to their environmental and human health impact. The emission sources should be stored in terms of relevant metrics and statistics in an easily accessible format that is applicable for source specific exposure assessment by using mathematical mass balance modelings. This forms a foundation for comprehensive risk assessment and efficient interventions. For such a general exposure assessment model we need 1) systematic methods for indoor aerosol emission source assessment, 2) source emission documentation in terms of relevant a) aerosol metrics and b) biological metrics, 3) default model parameterization for predictive exposure modeling, 4) other needs related to aerosol characterization techniques and modeling methods. Such a general exposure assessment model can be applicable for private, public, and occupational indoor exposure assessment, making it a valuable tool for public health professionals, product safety designers, industrial hygienists, building scientists, and environmental consultants working in the field of IAQ and health.


Asunto(s)
Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/estadística & datos numéricos , Monitoreo del Ambiente , Exposición por Inhalación/estadística & datos numéricos , Aerosoles , Contaminación del Aire/estadística & datos numéricos , Exposición a Riesgos Ambientales , Humanos , Modelos Teóricos , Material Particulado , Medición de Riesgo
8.
J Phys Chem C Nanomater Interfaces ; 123(51): 30986-30995, 2019 Dec 26.
Artículo en Inglés | MEDLINE | ID: mdl-31983933

RESUMEN

Highly porous cellulose nanofiber (CNF) aerogels are promising, environmentally friendly, reusable, and low-cost materials for several advanced environmental, biomedical, and electronic applications. The aerogels have a complex and hierarchical 3D porous network structure with pore sizes ranging from nanometers to hundreds of micrometers. The morphology of the network has a critical role on the performance of aerogels, but it is difficult to characterize thoroughly with traditional techniques. Here, we introduce a combination of nuclear magnetic resonance (NMR) spectroscopy techniques for comprehensive characterization of pore sizes and connectivity in the CNF aerogels. Cyclohexane absorbed in the aerogels was used as a probe fluid. NMR cryoporometry enabled us to characterize the size distribution of nanometer scale pores in between the cellulose nanofibers in the solid matrix of the aerogels. Restricted diffusion of cyclohexane revealed the size distribution of the dominant micrometer scale pores as well as the tortuosity of the pore network. T 2 relaxation filtered microscopic magnetic resonance imaging (MRI) method allowed us to determine the size distribution of the largest, submillimeter scale pores. The NMR techniques are nondestructive, and they provide information about the whole sample volume (not only surfaces). Furthermore, they show how absorbed liquids experience the complex 3D pore structure. Thorough characterization of porous structures is important for understanding the properties of the aerogels and optimizing them for various applications. The introduced comprehensive NMR analysis set is widely usable for a broad range of different kinds of aerogels used in different applications, such as catalysis, batteries, supercapacitors, hydrogen storage, etc.

9.
PLoS One ; 13(8): e0202477, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30125308

RESUMEN

Recent findings show that cerium oxide (CeO2) nanoparticles may undergo in vivo-induced size transformation with the formation of smaller particles that could result in a higher translocation following pulmonary exposure compared to virtually insoluble particles, like titanium dioxide (TiO2). Therefore, we compared liver deposition of CeO2 and TiO2 nanoparticles of similar primary sizes 1, 28 or 180 days after intratracheal instillation of 162 µg of NPs in female C57BL/6 mice. Mice exposed to 162 µg CeO2 or TiO2 nanoparticles by intravenous injection or oral gavage were included as reference groups to assess the amount of NPs that reach the liver bypassing the lungs and the translocation of NPs from the gastrointestinal tract to the liver, respectively. Pulmonary deposited CeO2 nanoparticles were detected in the liver 28 and 180 days post-exposure and TiO2 nanoparticles 180 days post-exposure as determined by darkfield imaging and by the quantification of Ce and Ti mass concentration by inductively coupled plasma-mass spectrometry (ICP-MS). Ce and Ti concentrations increased over time and 180 days post-exposure the translocation to the liver was 2.87 ± 3.37% and 1.24 ± 1.98% of the initial pulmonary dose, respectively. Single particle ICP-MS showed that the size of CeO2 nanoparticles in both lung and liver tissue decreased over time. No nanoparticles were detected in the liver following oral gavage. Our results suggest that pulmonary deposited CeO2 and TiO2 nanoparticles translocate to the liver with similar calculated translocation rates despite their different chemical composition and shape. The observed particle size distributions of CeO2 nanoparticles indicate in vivo processing over time both in lung and liver. The fact that no particles were detected in the liver following oral exposure showed that direct translocation of nanoparticles from lung to the systemic circulation was the most important route of translocation for pulmonary deposited particles.


Asunto(s)
Cerio , Hígado/metabolismo , Pulmón/metabolismo , Nanopartículas/efectos adversos , Animales , Cerio/efectos adversos , Cerio/farmacocinética , Cerio/farmacología , Femenino , Ratones , Especificidad de Órganos/efectos de los fármacos , Titanio/efectos adversos , Titanio/farmacocinética , Titanio/farmacología
10.
J Nanopart Res ; 20(2): 48, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29497347

RESUMEN

Fume hoods are one of the most common types of equipment applied to reduce the potential of particle exposure in laboratory environments. A number of previous studies have shown particle release during work with nanomaterials under fume hoods. Here, we assessed laboratory workers' inhalation exposure during synthesis and handling of CuO, TiO2 and ZnO in a fume hood. In addition, we tested the capacity of a fume hood to prevent particle release to laboratory air during simulated spillage of different powders (silica fume, zirconia TZ-3Y and TiO2). Airborne particle concentrations were measured in near field, far field, and in the breathing zone of the worker. Handling CuO nanoparticles increased the concentration of small particles (< 58 nm) inside the fume hood (up to 1 × 105 cm-3). Synthesis, handling and packaging of ZnO and TiO2 nanoparticles did not result in detectable particle release to the laboratory air. Simulated powder spills showed a systematic increase in the particle concentrations inside the fume hood with increasing amount of material and drop height. Despite powder spills were sometimes observed to eject into the laboratory room, the spill events were rarely associated with notable release of particles from the fume hood. Overall, this study shows that a fume hood generally offers sufficient exposure control during synthesis and handling of nanomaterials. An appropriate fume hood with adequate sash height and face velocity prevents 98.3% of particles release into the surrounding environment. Care should still be made to consider spills and high cleanliness to prevent exposure via resuspension and inadvertent exposure by secondary routes.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA