Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
2.
J Arrhythm ; 40(3): 448-454, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38939764

RESUMEN

Background: The concept of ablation index (AI) was introduced to evaluate radiofrequency (RF) ablation lesions. It is calculated from power, contact force (CF), and RF duration. However, other factors may also affect the quality of ablation lesions. To examine the difference in RF lesions made during sinus rhythm (SR) and atrial fibrillation (AF). Methods: Sixty patients underwent index pulmonary vein isolation during SR (n = 30, SR group) or AF (n = 30, AF group). All ablations were performed with a power of 50 W, a targeted CF of 5-15 g, and AI of 400-450 using Thermocool Smarttouch SF. The CF, AI, RF duration, temperature rise (Δtemp), impedance drop (Δimp), and the CF stability of each ablation point quantified as the standard deviation of the CF (CF-SD) were compared between the two groups. Results: A total of 3579 ablation points were analyzed, which included 1618 and 1961 points in the SR and the AF groups, respectively. Power, average CF, RF duration per point, and the resultant AI (389 ± 59 vs. 388 ± 57) were similar for the two rhythms. However, differences were seen in the CF-SD (3.5 ± 2.2 vs. 3.8 ± 2.1 g, p < .01), Δtemp (3.8 ± 1.3 vs. 4.0 ± 1.3°C, p < .005), and Δimp (10.3 ± 5.8 vs. 9.4 ± 5.4 Ω, p < .005). Conclusions: Despite similar AI, various RF parameters differed according to the underlying atrial rhythm. Ablation delivered during SR demonstrated less CF variability and temperature increase and greater impedance drop than during AF.

3.
J Cardiovasc Electrophysiol ; 35(2): 348-359, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38180129

RESUMEN

INTRODUCTION: It would be helpful in determining ablation strategy if the occurrence of perimitral atrial tachycardia (PMAT) could be predicted in advance. We investigated whether estimated perimitral conduction time (E-PMCT), namely, twice the time between coronary sinus (CS) pacing and the ensuing wave-front collision at the opposite side of the mitral annulus, correlated with the cycle length of PMAT and could predict future PMAT. METHODS AND RESULTS: We retrospectively (retrospective cohort) and prospectively (validation cohort) investigated atrial fibrillation patients who had received pulmonary vein isolation (PVI) and in whom left atrial maps had been created during CS pacing. We calculated their E-PMCT. PMAT was observed either by provocation or during follow-up in 25, AT other than PMAT was observed in 24 (non-PMAT AT group), and 53 patients never displayed any AT (no-AT group) in the retrospective cohort. In the PMAT group of the retrospective cohort, a strong positive correlation was observed between the PMAT CL and E-PMCT (r = .85, p < 0.001). PMAT was never induced nor observed in patients with E-PMCT less than 176 ms, and the best cut-off value for PMAT was 180 ms by receiver-operating characteristic curve analysis. In the validation cohort of 76 patients, the cut-off value of the E-PMAT less than 180 ms predicted noninducibility of PMAT, with a sensitivity of 78.6%, specificity of 100%, positive predictive value of 100%, and negative predictive value of 25.0%. CONCLUSION: Short E-PMCT may predict noninducibility of PMAT and guide a less invasive ablation strategy.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Taquicardia Supraventricular , Humanos , Estudios Retrospectivos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/etiología , Taquicardia Supraventricular/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Frecuencia Cardíaca , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Resultado del Tratamiento , Venas Pulmonares/cirugía
4.
J Cardiol ; 83(5): 298-305, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-37802202

RESUMEN

BACKGROUND: Percutaneous left atrial appendage closure (LAAC) has increased for those who need alternative to long-term anticoagulation with non-valvular atrial fibrillation (NVAF). METHODS AND RESULTS: From September 2019, after initiating WATCHMAN (Boston Scientific, Maple Grove, MN, USA) device implantation, we established Transcatheter Modification of Left Atrial Appendage by Obliteration with Device in Patients from the NVAF (TERMINATOR) registry. Utilizing 729 patients' data until January 2022, we analyzed percutaneous LAAC data regarding this real-world multicenter prospective registry. A total of 729 patients were enrolled. Average age was 74.9 years and 28.5 % were female. Paroxysmal AF was 37.9 % with average CHADS2 3.2, CHA2DS2-VASc 4.7, and HAS-BLED score of 3.4. WATCHMAN implantation was successful in 99.0 %. All-cause deaths were 3.2 %, and 1.2 % cardiovascular or unexplained deaths occurred during follow-up [median 222, interquartile range (IQR: 93-464) days]. Stroke occurred in 2.2 %, and the composite endpoint which included cardiovascular or unexplained death, stroke, and systemic embolism were counted as 3.4 % [median 221, (IQR: 93-464) days]. Major bleeding defined as BARC type 3 or 5 was seen in 3.7 %, and there was 8.6 % of all bleeding events in total [median 219, (IQR: 93-464) days]. CONCLUSIONS: These preliminary data demonstrated percutaneous LAAC with WATCHMAN device might have a potential to reduce stroke and bleeding events for patients with NVAF. Further investigation is mandatory to confirm the long-term results of this strategy using this transcatheter local therapy instead of life-long systemic anticoagulation.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Humanos , Femenino , Anciano , Masculino , Fibrilación Atrial/complicaciones , Fibrilación Atrial/terapia , Apéndice Atrial/cirugía , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Anticoagulantes , Sistema de Registros , Resultado del Tratamiento
5.
J Cardiovasc Electrophysiol ; 34(8): 1658-1664, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37393583

RESUMEN

BACKGROUND: Although atrial flutter (AFL) is a common arrhythmia that is based on a macro-reentrant tachycardia around the tricuspid annulus, the factors giving rise to typical AFL (t-AFL) versus reverse typical AFL (rt-AFL) are unknown. To investigate the difference between t-AFL and rt-AFL circuits using ultrahigh resolution mapping of the right atrium. METHODS: We investigated 30 isthmus-dependent AFL patients (mean age 71, 28 male) who underwent first-time cavo-tricuspid isthmus (CTI) ablation guided by Boston Scientific's Rhythmia mapping system and divided them into two groups: t-AFL (22 patients) and rt-AFL (8 patients). We compared the anatomy and electrophysiology of their reentrant circuits. RESULTS: Baseline patient characteristics, use of antiarrhythmic drugs, prevalence of atrial fibrillation, AFL cycle length (227.1 ± 21.4 vs. 245.5 ± 36.0 ms, p = .10), and CTI length (31.9 ± 8.3 vs. 31.1 ± 5.2 mm, p = .80) did not differ between the two groups. Functional block was observed at the crista terminalis in 16 patients and at the sinus venosus in 11. No functional block was observed in three patients, all of whom belonged to the rt-AFL group. That is, functional block was observed in 100% of the t-AFL group as opposed to 5/8 (62.5%) of the rt-AFL (p < .05). Slow conduction zones were frequently observed at the intra-atrial septum in the t-AFL group and at the CTI in the rt-AFL group. CONCLUSION: Mapping with ultrahigh-resolution mapping showed differences between t-AFL and rt-AFL in conduction properties in the right atrium and around the tricuspid valve, which suggested directional mechanisms.


Asunto(s)
Aleteo Atrial , Ablación por Catéter , Humanos , Masculino , Aleteo Atrial/diagnóstico , Aleteo Atrial/cirugía , Atrios Cardíacos , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Frecuencia Cardíaca/fisiología
6.
Pacing Clin Electrophysiol ; 45(9): 1042-1050, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35883271

RESUMEN

INTRODUCTION: Mitral valve surgery employing a superior transseptal approach (STA) is associated with arrhythmogenicity and intra-atrial conduction delay, despite being optimal for visualization of the surgical field. It is sometimes difficult to treat atrial tachycardias (AT) that arise after STA. To investigate AT circuits that arise after STA in detail in order to identify the optimal ablation line, using ultra-high-resolution mapping (UHRM). METHODS: We retrospectively analyzed 12 AT from 10 patients (median age 70 years, nine males) who had undergone STA surgery. The tachycardias were mapped using the Rhythmia mapping system (Boston Scientific, Natick, Massachusetts). RESULTS: The 12 STA-related AT (STA-AT) circuits were classifiable as follows according to location of the optimal ablation line: (1) peri-septal incision STA-AT (n = 3), (2) cavotricuspid isthmus (CTI) dependent STA-AT (n = 7), and (3) biatrial tachycardia (n = 2). Radiofrequency (RF) application terminated 11 of the 12 STA-AT. We found that difference in STA-AT circuit type was due to characteristics of the septal incision line made for STA. UHRM was important in identifying optimal ablation sites that did not create additional conduction disturbances in the right atrium (RA). CONCLUSIONS: ATs after STA involve complex arrhythmia circuits due to multiple and long incision lines in the RA. Accurate understanding of the arrhythmia circuit and sinus conduction in the RA after STA is recommended for treating post-surgical tachycardia in a minimally invasive manner.


Asunto(s)
Bloqueo Atrioventricular , Ablación por Catéter , Taquicardia Supraventricular , Anciano , Arritmias Cardíacas/cirugía , Bloqueo Atrioventricular/cirugía , Técnicas Electrofisiológicas Cardíacas , Humanos , Masculino , Válvula Mitral/cirugía , Estudios Retrospectivos , Taquicardia , Taquicardia Supraventricular/etiología , Taquicardia Supraventricular/prevención & control , Taquicardia Supraventricular/cirugía , Resultado del Tratamiento
7.
J Cardiovasc Electrophysiol ; 32(12): 3146-3155, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34664757

RESUMEN

INTRODUCTION: Catheter ablation for perimitral atrial tachycardia (PMAT) that persists despite lateral mitral isthmus (LMI) ablation is challenging. The aim of this study was to identify the role of the ligament of Marshall (LOM) in PMATs that persist after LMI conduction block has been created, and evaluate the validity of ethanol infusion into the vein of Marshall (VOM) as treatment. METHODS AND RESULTS: Sixteen consecutive PMATs in 13 patients that persisted despite apparent LMI conduction block, which was confirmed by ultrahigh-resolution mapping and entrainment pacing along the mitral annulus, were analyzed. PMATs were classified into two types based on the location of the endocardial breakthrough site: those utilizing the LOM (n = 13), which had a breakthrough site along with the LOM, and those not utilizing the LOM (n = 3), which had a breakthrough site at an anterior or posterior side of the LOM. Of the 16 PMATs, 5 PMATs (31%) were not suitable for ethanol infusion into the VOM because the LOM was not involved in the tachycardia circuit or because of the anatomy of the VOM. Fourteen PMATs (88%) were successfully terminated solely by breakthrough site ablation. At a mean follow-up period of 12 ± 9 months, 10 (77%) patients have remained free from atrial tachyarrhythmias. CONCLUSION: In cases of PMAT following LMI ablation, epicardial conduction over the LMI can occur independently of the LOM. Ethanol infusion into the VOM in such cases would not abolish residual epicardial conduction. The anatomy of the VOM can also preclude the use of this method.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Taquicardia Supraventricular , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Atrios Cardíacos , Frecuencia Cardíaca , Humanos , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/etiología , Taquicardia Supraventricular/cirugía
8.
Br J Radiol ; 94(1128): 20210361, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34520243

RESUMEN

OBJECTIVES: Previous studies reported the association between inflammation and atrial fibrillation (AF). Pericoronary adipose tissue (PCAT) attenuation, PCATA, on cardiac CT angiography (CTA) reflects pericoronary inflammation. We hypothesized that the PCATA predicts AF recurrence after cryoballoon ablation (CBA) for paroxysmal and persistent AF. METHODS: We studied 364 patients (median age, 65 years) with persistent (n = 41) and paroxysmal (n = 323) AF undergoing successful first-session second-generation CBA with pre-ablation cardiac CTA. Three-vessel (3V)-PCATA was defined as the mean CT attenuation value of PCAT of all three major coronary arteries. Predictors of AF recurrence during follow-up were evaluated. RESULTS: AF recurrence after the 3-month blanking period was detected in 90 patients (24.7%) during the median follow-up of 26 (interquartile range, 19-42) months. AF recurrence was associated with prior stroke and statin use, NT-proBNP and high-sensitivity cardiac troponin-I levels, left ventricular dimension, left atrial volume index (LAVI), 3V-PCATA, and early AF recurrence during the blanking period. On multivariable Cox proportional hazard analysis, prior stroke (hazard ratio [HR], 2.208, 95% confidence interval [CI], 1.166-4.180, p = 0.015), LAVI (HR, 1.030, 95% CI, 1.010-1.051, p = 0.003), 3V-PCATA (HR, 1.034, 95% CI, 1.001-1.069, p = 0.046), and early AF recurrence (HR, 2.858, 95% CI, 1.855-4.405, p < 0.001) remained statistically significant. CONCLUSION: Pre-ablation CTA-derived 3V-PCATA, representing pericoronary inflammation, was an independent predictor of recurrence after first-session AF ablation using a second-generation cryoballoon. ADVANCES IN KNOWLEDGE: Assessment of 3V-PCATA may identify patients at high risk of AF recurrence after CBA for AF.


Asunto(s)
Tejido Adiposo/diagnóstico por imagen , Fibrilación Atrial/cirugía , Angiografía por Tomografía Computarizada/métodos , Criocirugía/métodos , Anciano , Fibrilación Atrial/diagnóstico por imagen , Femenino , Corazón/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
9.
Int Heart J ; 62(4): 771-778, 2021 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-34276012

RESUMEN

Radiofrequency catheter ablation (RFCA) for pulmonary artery ventricular arrhythmia (PAVA) can be difficult because of the occasional existence of PAVA with preferential conduction.This study described the characteristics of PAVA that demonstrate preferential conduction.We analyzed electrocardiographic and electrophysiological data from 8 patients found to have PAVAs with preferential conduction out of 183 patients (4.4%) with right ventricular outflow tract (RVOT) arrhythmias who underwent RFCA at our hospitals. The PAVA with preferential conduction were classified into two types. In type 1 PAVA, successful ablation sites (success-sites) exhibited discrete prepotentials with an isoelectric line, in which the activation time (AT) was ≥ 50 milliseconds. In type 2 PAVA, excellent pace mapping was achieved at two sites separated by ≥ 20 mm: one in the RVOT free wall and the other at the success-site in the pulmonary artery. Type 1 and 2 PAVA features were considered signs of a short and long preferential conduction pathway, respectively.There were four patients each with type 1 and 2 PAVA. Type 1 PAVA was distinguished by the isoelectric line at success-sites with the mean AT of 78 ± 25.1 milliseconds. In type 2 PAVAs, although the AT at RVOT sites was very short (18.5 ± 10.1 milliseconds), the AT at success-sites was longer than that at the RVOT by 42.3 ± 36.2 milliseconds. Type 2 PAVAs displayed distinct electrocardiogram (ECG) features (R wave in lead I, RR' in inferior leads, and transitional zone in V4) not found in typical PAVA ECGs.PAVA with preferential conduction can manifest in distinct ways on the ECG and intracardiac mapping. Knowledge of these features may facilitate successful RFCA of such PAVA cases.


Asunto(s)
Arritmias Cardíacas/fisiopatología , Ablación por Catéter , Electrocardiografía , Arteria Pulmonar/fisiopatología , Adolescente , Adulto , Anciano , Arritmias Cardíacas/etiología , Arritmias Cardíacas/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad
10.
J Arrhythm ; 37(3): 676-682, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34141021

RESUMEN

BACKGROUND: Pacemaker positioning on the right ventricular (RV) septum during implantation is conventionally conducted utilizing two fixed fluoroscopy angles, a 45° left anterior oblique (LAO) and 35° right anterior oblique projection. However, placement location can be suboptimal, especially for leadless pacemakers (LPMs). OBJECTIVE: To evaluate the safety and ease of LPM implantation using individualized LAO projection. METHODS: Consecutive patients undergoing LPM implantation were prospectively included. The angle of the RV septum was recorded for each patient by studying the angle at which an RV pigtail catheter (RV-PC) could be seen edge on. This was then used as the preferred LAO projection angle for that patient. We evaluated the success rate and safety of this method. We also compared the RV septum angle as measured by this method versus that measured by chest CT. RESULTS: Of the 31 patients (mean age 80.6 ± 7.0 years, 15 females), LPM implantation was successful in 30. The pacemaker was implanted on the RV septum in 29 and on the free wall in one. LPM implantation was abandoned for anatomical reasons in one. Complications were limited to a groin arteriovenous fistula and one deep vein thrombosis. The angle of RV septum as measured by pigtail catheter and chest CT was not significantly different (CT: 54.8 ± 6.0°, RV pigtail catheter: 52.9 ± 6.1°, P = .07). CONCLUSIONS: Using an RV-PC to determine the preferred angle of LAO projection facilitates differentiation between the RV septum and free wall, which in turn facilitates optimal LPM placement.

11.
J Cardiovasc Electrophysiol ; 32(6): 1602-1609, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33949738

RESUMEN

INTRODUCTION: The optimal ablation strategy is unknown regarding a superior vena cava isolation (SVCI). This study aimed to examine the feasibility and safety and to analyze the lesion characteristics of the SVCI using high-power, short-duration (HPSD) ablation. METHODS AND RESULTS: A total of 100 patients underwent an index SVCI using HPSD (n = 50, HPSD group) or conventional lower-power and longer-duration (n = 50, LPLD group) ablation, using the Thermocool Smarttouch SF. In the HPSD group, ablation was performed with a power of 50 W for 7 s, and was limited to 4 s at the lateral segment close to the right phrenic nerve. The ablation setting used in the LPLD group was 20-25 W for 20-30 s and was limited to 10-20 W for 15-30 s at the lateral segment when diaphragmatic capture was seen. An electrical SVCI was achieved in all patients. The HPSD group required a significantly shorter procedure time (10.8 ± 3.2 vs. 14.8 ± 6.4 min; p < .01), shorter radiofrequency duration (49 ± 16 vs. 282 ± 124 s; p < .01), fewer lesions (8.3 ± 2.5 vs. 10.4 ± 4.4; p < .01), and lower ablation index (316 ± 38 vs. 356 ± 62; p < .001) than the LPLD group. The incidence of a postprocedural asymptomatic mild diaphragmatic elevation was comparable (2% in the HPSD group vs. 6% in the LPLD group; p = .61). CONCLUSION: The 50-W HPSD ablation strategy allowed for a successful, fast, and safe SVCI with the fewer ablation lesions and the lower ablation index.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Diafragma , Humanos , Nervio Frénico , Vena Cava Superior/diagnóstico por imagen , Vena Cava Superior/cirugía
12.
JACC Clin Electrophysiol ; 6(14): 1797-1807, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33357576

RESUMEN

OBJECTIVES: This study sought to assess the performance of current diagnostic criteria and identify additional electrophysiological features differentiating orthodromic reciprocating tachycardia (ORT) with a concealed nodoventricular/nodofascicular (NV/NF) pathway from atrioventricular nodal re-entrant tachycardia (AVNRT). BACKGROUND: Diagnosing sustained supraventricular tachycardia (SVT) despite the occurrence of ventriculoatrial block (VAB) is challenging. METHODS: We analyzed electrograms of 25 sustained SVTs (9 NV/NF-ORTs [n = 7/2] and 16 AVNRTs) with VAB and 91 AVNRTs without VAB (for reference). RESULTS: More than 1 SVT, each with a different ventriculoatrial interval, was commonly induced in AVNRT cases (75%) but not in NV/NF-ORT cases (0%; p = 0.0005). Wenckebach VAB was common in NV/NF-ORTs (78%), but VAB patterns varied in AVNRTs. The His-His interval transiently prolonged in the following beat after the VAB in most AVNRTs but rarely did in NV/NF-ORTs (79% vs. 22%; p = 0.01). NV/NF-ORT was diagnosed by His-refractory premature ventricular contractions (n = 5) and the findings during right ventricular overdrive pacing showing an uncorrected/corrected post-pacing interval (PPI)-tachycardia cycle length (TCL) ≤115/110 ms (n = 5/5), orthodromic His capture (n = 6), and V-V-A (ventricle-ventricle-atrial response) response (n = 3). A single form of induced SVT (positive predictive value [PPV]: 69%; negative predictive value [NPV]: 100%), Wenckebach VAB (PPV: 70%; NPV: 87%), stable His-His interval despite VAB (PPV: 70%; NPV: 85%), orthodromic His capture (PPV: 100%; NPV: 97%), and V-V-A response (PPV: 100%; NPV: 95%) characterized NV/NF-ORT, and a PPI-TCL of ≤125 ms (PPV: 100%; NPV: 100%) characterized NV-ORT. CONCLUSIONS: Induction of a single SVT form, Wenckebach VAB, stable His-His interval despite VAB, orthodromic His capture, and V-V-A response appeared to discriminate NV/NF-ORT from AVNRT, with a PPI-TCL of ≤125 ms discriminating NV-ORT from NF-ORT and AVNRT.


Asunto(s)
Taquicardia por Reentrada en el Nodo Atrioventricular , Taquicardia Reciprocante , Taquicardia Ventricular , Estimulación Cardíaca Artificial , Electrocardiografía , Sistema de Conducción Cardíaco , Humanos , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico
13.
J Electrocardiol ; 61: 161-163, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32721656

RESUMEN

A 77-year-old man with frequent monomorphic ventricular premature contractions (VPCs) was referred for catheter ablation. Detailed mapping just above the pulmonary valve (PV) revealed tiny fragmented potentials earlier than the VPC onset. Perfect pace-mapping was obtained using high voltage pacing just above the PV and the left aortic sinus of Valsalva, whose stimulus-to-VPC latencies differed by 20 ms. While the ablation at the pulmonary valve could not completely eliminate the VPCs, unipolar sequential ablation on both sides of the outflow tracts led to their successful abolition that was guided by perfect pace-mapping.


Asunto(s)
Ablación por Catéter , Seno Aórtico , Taquicardia Ventricular , Complejos Prematuros Ventriculares , Anciano , Electrocardiografía , Humanos , Masculino , Seno Aórtico/cirugía , Taquicardia Ventricular/cirugía , Resultado del Tratamiento , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/cirugía
14.
Heart Vessels ; 35(1): 125-131, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31292708

RESUMEN

The association between circulatory dynamics changes during cryoballoon applications and a successful pulmonary vein isolation (PVI) is unknown. Seventy atrial fibrillation patients who underwent PVI with 28-mm second-generation cryoballoons and single 3-min freezes were included. Intra-procedural parameters including circulatory dynamics changes during cryoapplications, were compared between 113 successful applications (30 left superior PVs[LSPVs], 30 left inferior PVs[LIPVs], 25 right superior PVs[RSPVs], and 28 right inferior PVs[RIPVs]) and 47 failed applications (10 LSPVs, 9 LIPVs, 8 RSPVs, and 20 RIPVs). In all individual PVs, lower nadir balloon temperatures (MinTemps) and longer thawing times (ThawTimes) significantly predicted a successful PVI. In addition, greater systolic blood pressure drops following releasing the PV occlusion (SBP-drops) significantly predicted a successful right PV PVI, and longer elapse times during SBP-drops significantly predicted a successful RIPV PVI. Composite parameters incorporating MinTemps and ThawTimes, SBP-drops, and ThawTimes showed the highest area under the curve to predict a successful left PV (0.876 for LSPVs, 0.851 for LIPVs) and right PV (0.927 for RSPVs, 0.980 for RIPVs) PVI, respectively. If the ThawTime (≥ 30 s) and SBP-drop (≤ - 21 mmHg) cutoff values were achieved for the RIPVs, the positive predictive value was 100%. In contrast, if both criteria were not achieved for the RIPVs, the negative predictive value was 100%. In the second-generation cryoballoon PVI, the MinTemp and ThawTime were significantly associated with acute success for all four PVs. In addition, SBP-drops further improved the accuracy of predicting a successful right PV PVI, especially of the RIPV.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Criocirugía , Hemodinámica , Venas Pulmonares/cirugía , Potenciales de Acción , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Presión Sanguínea , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Frecuencia Cardíaca , Humanos , Tempo Operativo , Venas Pulmonares/fisiopatología , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
16.
J Cardiovasc Electrophysiol ; 30(7): 1148-1149, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30907026

RESUMEN

A 62-year-old man underwent the catheter ablation for persistent atrial tachycardia (AT) with a cycle length of 357 milliseconds. An ultrahigh resolution mapping revealed that this tachycardia was a clockwise perimitral AT despite the conduction was apparently blocked across the lateral mitral isthmus line both at the endocardium and within the coronary sinus. The AT was terminated by the single radiofrequency application at the site below the mitral isthmus line where the endocardial activation breakout was seen. This case suggests that the epicardial-endocardial conduction breakthrough site may be an alternative ablation target in a difficult ablation case of perimitral AT.


Asunto(s)
Ablación por Catéter , Endocardio/cirugía , Válvula Mitral/cirugía , Pericardio/cirugía , Taquicardia Supraventricular/cirugía , Potenciales de Acción , Técnicas Electrofisiológicas Cardíacas , Endocardio/fisiopatología , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/fisiopatología , Pericardio/fisiopatología , Recurrencia , Reoperación , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatología
17.
Heart Vessels ; 34(3): 503-508, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30178186

RESUMEN

Sick sinus syndrome (SSS) frequently coexists with atrial fibrillation (AF). The results of AF ablation in patients with SSS have not been fully evaluated. We retrospectively investigated 65 patients with paroxysmal AF (PAF) and SSS who underwent AF ablation using either radiofrequency (n = 50) or cryoballoon ablation (n = 15) in our institute. Forty-nine (75.4%) patients had a median of 5.6 (4.8-6.0) s of documented sinus pauses prior to the procedure (42 patients on antiarrhythmic drugs), and were observed when AF terminated in 47 patients. Successful pulmonary vein isolation was achieved in all, and substrate modification was added in 3 patients. Freedom from recurrent atrial arrhythmias after single procedures was 58.7, 45.2, and 38.9% at 1, 2, and 3 years after the initial procedure. During a 23.4 (11.1-40.7) month median follow-up and after 1.4 ± 0.6 sessions, 80.6% of patients were free from arrhythmia recurrence; however, permanent pacemaker implantations were required in 9 (13.8%) patients at a median of 5.3 (2.9-21.0) months after initial procedures. The average heart rate did not significantly differ before or a median of 2.5 (1.2-5.3) months post-procedure (76.7 ± 17.4 vs. 73.5 ± 14.6 bpm, p = 0.90). Multivariate analyses revealed that larger left atrial diameters [odds ratio (OR) 1.21, 95% confidential interval (CI) 1.01-1.45, p = 0.042] were independent predictor of AF recurrence, and SSS type 1 was the sole predictor of pacemaker implantations (OR 10.30, 95% CI 1.38-76.7, p = 0.023), respectively. AF ablation obviated permanent pacemaker implantations in the majority of the patients with SSS and PAF, and SSS type 1 was a sole factor predicting pacemaker implantations.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Sistema de Conducción Cardíaco/fisiopatología , Venas Pulmonares/cirugía , Síndrome del Seno Enfermo/cirugía , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/fisiopatología , Mapeo del Potencial de Superficie Corporal , Femenino , Estudios de Seguimiento , Sistema de Conducción Cardíaco/cirugía , Humanos , Masculino , Estudios Retrospectivos , Síndrome del Seno Enfermo/complicaciones , Síndrome del Seno Enfermo/fisiopatología , Resultado del Tratamiento
18.
Pacing Clin Electrophysiol ; 42(1): 107-109, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30191572

RESUMEN

A 53-year-old male underwent a pulmonary vein isolation (PVI) of atrial fibrillation (AF) with a second-generation cryoballoon (CB). Although the patient maintained sinus rhythm after the PVI, a superior vena cava (SVC) fibrillation was recorded by a circular-multipolar-electrode catheter positioned inside the SVC that suggested conduction block between the right atrium (RA)-SVC connection. An adenosine triphosphate intravenous injection induced a dormant reconnection of the SVC myocardial sleeve and converted sinus rhythm to an AF rhythm. This case demonstrated that a CB application for the isolation of a right superior pulmonary vein could induce an electrical conduction block between the RA-SVC connection.


Asunto(s)
Adenosina Trifosfato/administración & dosificación , Fibrilación Atrial/cirugía , Crioterapia/efectos adversos , Bloqueo Cardíaco/tratamiento farmacológico , Bloqueo Cardíaco/etiología , Venas Pulmonares/cirugía , Vena Cava Superior/fisiopatología , Fibrilación Atrial/fisiopatología , Electrocardiografía , Humanos , Masculino , Persona de Mediana Edad
19.
Heart Vessels ; 34(2): 324-330, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30062430

RESUMEN

It is unclear whether the electrocardiogram amplitude in the inferior leads (Amp-I) can always predict the height of the origin of right ventricular outflow tract arrhythmias (RVOT-VAs). We analyzed patients who received catheter ablation of multiple RVOT-VAs in the same session in our hospital from 2011 to 2016. Two distinguished RVOT-VAs, those with anatomically higher origins (HOs) and lower origins (LOs), were identified and compared to measure the longitudinal distance. Amp-I was uniquely determined for each OTVA as the highest amplitude in leads II, III, and aVF and compared between the HO-VAs and LO-VAs. In total, out of 187 patients who underwent catheter ablation of RVOT-VAs, 9 (4.8%) had multiple right OTVAs successfully treated. Four cases (Group A) had HO-VAs (10.8 ± 5.3 mm from an LO) with a lower Amp-I (1.28 ± 0.46 mV) than the LO-VAs (1.81 ± 0.59 mV), whereas the other 4 patients (Group B) had HO-VAs with a higher Amp-I (1.91 ± 0.23 mV) than the LO-VAs (1.26 ± 0.35 mV). In Group A, all HO-VAs originated from the lateral free wall and had notched R waves in the inferior leads, whereas all LOs with higher Amp-Is were located on the septum. In one patient, the HO and LO were at almost the same height, while a VA from a lateral origin had lower notched R waves in the inferior leads. A divided excitation from high lateral origins may result in not only QRS notching, but also a reduction in the QRS amplitude. In patients harboring multiple RVOT-VAs, VAs arising from the high lateral free wall could have lower Amp-Is than VAs from low septal origins.


Asunto(s)
Ablación por Catéter , Electrocardiografía/métodos , Sistema de Conducción Cardíaco/fisiopatología , Ventrículos Cardíacos/fisiopatología , Imagenología Tridimensional , Taquicardia Ventricular/fisiopatología , Función Ventricular Derecha/fisiología , Adolescente , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Adulto Joven
20.
Pacing Clin Electrophysiol ; 42(2): 267-274, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30569491

RESUMEN

PURPOSE: Low-dose adenosine triphosphate (LD-ATP) is useful for diagnosing ATP-sensitive atrial tachycardia. However, the clinical implications of the sensitivity of LD-ATP in atrioventricular nodal reentrant tachycardia (AVNRT) still remain unknown. This study aimed to evaluate the mechanism of LD-ATP sensitivity in slow-fast AVNRT. METHODS: We estimated the sensitivity of LD-ATP in slow-fast AVNRT by a 2-4-mg ATP intravenous injection during the tachycardia. We evaluated the atrial-His (A-H) interval, tachycardia termination mode, prevalence of a lower common pathway (LCP), and successful ablation site in slow-fast AVNRT with LD-ATP sensitivity. LCPs were defined as His-atrial interval differences of at least 5 ms between that during ventricular pacing at the tachycardia cycle length and that during the tachycardia. RESULTS: Twenty-eight patients (mean age = 58 ± 11 years old, 18 females) with slow-fast AVNRT, who underwent catheter ablation of the antegrade slow pathway, were enrolled. Seventeen of 28 (61%) patients had LD-ATP sensitivity defined as termination of the tachycardia and/or a prolongation of the A-H interval of over 30 ms after an LD-ATP injection. The patients with LD-ATP sensitivity had a significantly higher prevalence of an LCP than those without (15/17 vs0/11, P < 0.0001). The successful ablation site in the LD-ATP sensitive group was significantly closer to the His bundle area than that in the LD-ATP nonsensitive group (13.3 ± 3.8 vs 20.5 ± 5.4 mm; distance to His bundle area in the left anterior oblique fluoroscopic view, P < 0.0001). CONCLUSIONS: LD-ATP sensitivity in slow-fast AVNRT may suggest the existence of an LCP. The successful ablation site in patients with LD-ATP sensitivity could be closer to the His bundle region.


Asunto(s)
Adenosina Trifosfato/administración & dosificación , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Anciano , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad , Taquicardia por Reentrada en el Nodo Atrioventricular/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...