J Thromb Thrombolysis ; 49(4): 572-577, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-31786713

RESUMEN

Our knowledge about the incidence of pulmonary embolism (PE) and the performance of age adjusted D-dimers (Dd) cutoff amongst patients with lung cancer (LC) and suspected PE, remains limited. We retrospectively analyzed all clinically suspected patients who underwent computed tomography pulmonary angiography (CTPA) in a tertiary hospital during a 19 month period. Cancer diagnosis was established using ICD10 code. Eligible for Dd analysis were those tested up to 24 h prior to the scan. We analyzed 2549 patients (54.6% males, median age 68.8 years, IQR 57-78), 15.8% had active LC and 5.4% other cancers (oC), while 70% were scanned in the Emergency Department (ED) and the rest during hospitalization. Overall incidence of PE was 16%. LC, but not oC, increased significantly the risk for PE (OR 1.58, 95% CI 1.21-2.06). LC patients were less likely to have bilateral (aOR 0.16, 95% CI 0.07-0.4) or central PE (aOR 0.2, 95% CI 0.09-0.48). Amongst those diagnosed with PE in the ED, LC increased all-cause inhospital mortality (aOR 6.7, 95% CI 2.64-16.95). When age adjusted instead of conventional Dd cutoff was used for ruling out PE in the ED, specificity for LC patients increased (10.16% vs 3.91%) without false negative tests (negative likelihood ratio-NLR = 0). A higher cutoff of 1.13 mg/l raised specificity to 28.9%, with only one case missed (sensitivity: 97.4%, NLR: 0.09, 95% CI 0.01-0.64). LC increases the risk for PE and adversely affects prognosis. Age adjusted and probably an even higher, "LC adjusted" Dd cutoff, could increase the specificity of the test without compromising its sensitivity.


Asunto(s)
Productos de Degradación de Fibrina-Fibrinógeno/metabolismo , Neoplasias Pulmonares/complicaciones , Embolia Pulmonar/diagnóstico , Anciano , Anciano de 80 o más Años , Biomarcadores/sangre , Femenino , Grecia/epidemiología , Humanos , Incidencia , Neoplasias Pulmonares/sangre , Masculino , Persona de Mediana Edad , Embolia Pulmonar/sangre , Embolia Pulmonar/etiología , Embolia Pulmonar/mortalidad , Estudios Retrospectivos
3.
J Hum Hypertens ; 31(7): 479-482, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28124684

RESUMEN

A pocket-size cuffless electronic device for self-measurement of blood pressure (BP) has been developed (Freescan, Maisense Inc., Zhubei, Taiwan). The device estimates BP within 10 s using three embedded electrodes and one force sensor that is applied over the radial pulse to evaluate the pulse wave. Before use, basic anthropometric characteristics are recorded on the device, and individualized initial calibration is required based on a standard BP measurement performed using an upper-arm BP monitor. The device performance in providing valid BP readings was evaluated in 313 normotensive and hypertensive adults in three study phases during which the device sensor was upgraded. A formal validation study of a prototype device against mercury sphygmomanometer was performed according to the American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization (ANSI/AAMI/ISO) 2013 protocol. The test device succeeded in obtaining a valid BP measurement (three successful readings within up to five attempts) in 55-72% of the participants, which reached 87% with device sensor upgrade. For the validation study, 125 adults were recruited and 85 met the protocol requirements for inclusion. The mean device-observers BP difference was 3.2±6.7 (s.d.) mm Hg for systolic and 2.6±4.6 mm Hg for diastolic BP (criterion 1). The estimated s.d. (inter-subject variability) were 5.83 and 4.17 mm Hg respectively (criterion 2). These data suggest that this prototype cuffless BP monitor provides valid self-measurements in the vast majority of adults, and satisfies the BP measurement accuracy criteria of the ANSI/AAMI/ISO 2013 validation protocol.


Asunto(s)
Determinación de la Presión Sanguínea/instrumentación , Autocuidado/instrumentación , Adulto , Anciano , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad