Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J World Fed Orthod ; 13(4): 181-188, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38643033

RESUMEN

BACKGROUND: An uncommon location for placing miniscrews, used to provide anchorage control in various tooth movements, is the alveolar ridge. This study aimed to provide an evaluation of the success rate of alveolar ridge miniscrews and examine variables that might impact their success. METHODS: Charts for 295 patients who had miniscrews were screened. Twenty patients (5 male and 15 female: average age = 38.15 ± 15.10 years) with a total of 50 alveolar ridge miniscrews were analyzed. A customized data form was used to collect patients' and miniscrews' related variables. Kaplan-Meier estimator was used for the survival function, whereas Cox proportional hazards regression models were used to associate collected variables with alveolar ridge miniscrew survival. RESULTS: In total, 31 (62.0%) miniscrews were stable and 19 (38.0%) failed. The survival time for those that failed was 6.03 ± 7.08 months. The follow-up period for those that survived was 35.84 ± 19.47 months. Male gender versus female (hazard ratio [HR] 2.46; 95% confidence interval [CI] 1.35-4.48; P = 0.003), and if the miniscrew was a replacement versus non-replacement (HR 0.27; 95% CI 0.07-0.99; P = 0.048) influenced the survival. Additionally, miniscrews that were used for both indirect and direct or indirect anchorage alone plus those with evidence of splinting showed a 100% survival rate, which led to an HR 0 (P < 0.001). When the previously mentioned variables were modeled, none seemed to have a significant effect on failure except for splinting and type of anchorage (P < 0.001), because none of the splinted miniscrews failed. CONCLUSIONS: The failure rate of alveolar ridge miniscrews was (38.0%) over 6.03 ± 7.08 months. The survival rate was (62.0%) over 35.84 ± 19.47 months. The evidence of splinting and the type of anchorage had a significant effect on survival probability.


Asunto(s)
Proceso Alveolar , Tornillos Óseos , Métodos de Anclaje en Ortodoncia , Humanos , Femenino , Masculino , Métodos de Anclaje en Ortodoncia/instrumentación , Métodos de Anclaje en Ortodoncia/métodos , Proyectos Piloto , Adulto , Estudios Retrospectivos , Proceso Alveolar/cirugía , Resultado del Tratamiento , Persona de Mediana Edad , Estudios de Seguimiento , Factores Sexuales , Adulto Joven , Análisis de Supervivencia
2.
Prog Orthod ; 24(1): 27, 2023 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-37635155

RESUMEN

OBJECTIVES: This clinical report aims to highlight the factors affecting the clinical success of alveolar ridge mini-implants used for orthodontic anchorage and provide an overview of the biomechanical versatility of this miniscrew and steps involving the proper technique of its placement. METHODS: For this clinical report, charts for 295 patients who had temporary anchorage devices (TADs) were screened. Twenty patients [15 females and 5 males: mean age = 38.15 ± 15.10 years] with 50 alveolar ridge mini-screws were assessed. A descriptive summary of the main factors affecting their clinical success and the technique employed for their placement was comprehensively discussed and illustrated, in addition to the presentation of some clinical cases illustrating their potential clinical uses. RESULTS: The survival duration (7.32 ± 9.01 months) and clinical success of the alveolar ridge mini-implants that failed (19/50) seem to be affected primarily by 2 factors: splinting; none of the splinted mini-implants failed (0/10) compared to (19/40) of the single mini-implants that failed, and the length of the used mini-implant; the average length of the mini-implants that did not fail was 9.23 mm. Additionally, it appears that these mini-implants are biomechanically robust and durable, those that did not fail had an average survival duration of 35.97 ± 19.79 months. CONCLUSION: Ridge mini-implants offer significant biomechanical versatility in patients with partially edentulous ridges needing complex pre-prosthetic orthodontic movements. The presence of splinting and the length of the used mini-implants are factors that might affect the clinical success of the alveolar ridge mini-implants.


Asunto(s)
Proceso Alveolar , Movimiento , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA