1.
Sci Rep ; 14(1): 21429, 2024 09 13.
Artículo en Inglés | MEDLINE | ID: mdl-39271732

RESUMEN

Mitral regurgitation (MR) is associated with morphological and functional alterations of left atrium (LA) and ventricle (LV), possibly inducing LA-LV misalignment. We aimed to: (1) characterize angulation between LA and mitral annulus from conventional cine MRI data and feature-tracking (FT) contours, (2) assess their associations with functional capacity in MR patients, as assessed by oxygen consumption (peak-VO2) and minute ventilation to carbon dioxide production (VE/VCO2) slope, in comparison with MRI LA/LV strain indices. Thirty-two asymptomatic primary MR patients (56 [40; 66] years, 12 women) underwent cardiac MRI resulting in LA/LV conventional FT-derived strain indices. Then, end-diastolic angles were derived from FT LA contours: (1) α, centered on the LA centre of mass and defined by mitral valve extremities, (2) γ, centered on the mitral ring anterior/lateral side, and defined by LA centre and the other extremity of the mitral ring. Cardiopulmonary exercise testing with simultaneous echocardiography were also performed; peak-VO2 and VE/VCO2 slope were measured. While peak-VO2 and VE/VCO2 slope were not correlated to LA/LV strains, they were significantly associated with angles (α: r = 0.50, p = 0.003 and r = - 0.52, p = 0.003; γ: r = - 0.53, p = 0.002 and r = 0.52, p = 0.003; respectively), independently of age and gender (R2 ≥ 0.29, p ≤ 0.03). In primary MR, the new LA/mitral annulus angles, computed directly from standard-of-care MRI, are better correlated to exercise tolerance than conventional LA/LV strain.


Asunto(s)
Ventrículos Cardíacos , Imagen por Resonancia Cinemagnética , Insuficiencia de la Válvula Mitral , Humanos , Femenino , Masculino , Persona de Mediana Edad , Imagen por Resonancia Cinemagnética/métodos , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Anciano , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Adulto , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/fisiopatología , Prueba de Esfuerzo/métodos , Consumo de Oxígeno , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Ecocardiografía/métodos
2.
BMC Med Imaging ; 24(1): 168, 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38977955

RESUMEN

BACKGROUND: Coupling between left ventricle (LV) and left atrium (LA) plays a central role in the process of cardiac remodeling during aging and development of cardiac disease. The hydraulic force (HyF) is related to variation in size between LV and LA. The objectives of this study were to: (1) derive an estimate of left atrioventricular HyF using cine- Magnetic Resonance Imaging (MRI) in healthy subjects with a wide age range, and (2) study its relationship with age and conventional diastolic function parameters, as estimated by reference echocardiography. METHODS: We studied 119 healthy volunteers (mean age 44 ± 17 years, 58 women) who underwent Doppler echocardiography and MRI on the same day. Conventional transmitral flow early (E) and late (A) LV filling peak velocities as well as mitral annulus diastolic longitudinal peak velocity (E') were derived from echocardiography. MRI cine SSFP images in longitudinal two and four chamber views were acquired, and analyzed using feature tracking (FT) software. In addition to conventional LV and LA strain measurements, FT-derived LV and LA contours were further used to calculate chamber cross-sectional areas. HyF was approximated as the difference between the LV and LA maximal cross-sectional areas in the diastasis phase corresponding to the lowest LV-LA pressure gradient. Univariate and multivariate analyses while adjusting for appropriate variables were used to study the associations between HyF and age as well as diastolic function and strain indices. RESULTS: HyF decreased significantly with age (R²=0.34, p < 0.0001). In addition, HyF was significantly associated with conventional indices of diastolic function and LA strain: E/A: R²=0.24, p < 0.0001; E': R²=0.24, p < 0.0001; E/E': R²=0.12, p = 0.0004; LA conduit longitudinal strain: R²=0.27, p < 0.0001. In multivariate analysis, associations with E/A (R2 = 0.39, p = 0.03) and LA conduit strain (R2 = 0.37, p = 0.02) remained significant after adjustment for age, sex, and body mass index. CONCLUSIONS: HyF, estimated using FT contours, which are primarily used to quantify LV/LA strain on standard cardiac cine MRI, varied significantly with age in association with subclinical changes in ventricular filling. Its usefulness in cohorts of patients with left heart disease to detect LV-LA uncoupling remains to be evaluated.


Asunto(s)
Envejecimiento , Imagen por Resonancia Cinemagnética , Humanos , Femenino , Adulto , Masculino , Persona de Mediana Edad , Envejecimiento/fisiología , Imagen por Resonancia Cinemagnética/métodos , Anciano , Ventrículos Cardíacos/diagnóstico por imagen , Atrios Cardíacos/diagnóstico por imagen , Adulto Joven , Ecocardiografía Doppler
3.
Physiol Rep ; 12(12): e16090, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38884325

RESUMEN

Adverse effects of large artery stiffening are well established in the systemic circulation; stiffening of the proximal pulmonary artery (PPA) and its sequelae are poorly understood. We combined in vivo (n = 6) with ex vivo data from cadavers (n = 8) and organ donors (n = 13), ages 18 to 89, to assess whether aging of the PPA associates with changes in distensibility, biaxial wall strain, wall thickness, vessel diameter, and wall composition. Aging exhibited significant negative associations with distensibility and cyclic biaxial strain of the PPA (p ≤ 0.05), with decreasing circumferential and axial strains of 20% and 7%, respectively, for every 10 years after 50. Distensibility associated directly with diffusion capacity of the lung (R2 = 0.71, p = 0.03). Axial strain associated with right ventricular ejection fraction (R2 = 0.76, p = 0.02). Aging positively associated with length of the PPA (p = 0.004) and increased luminal caliber (p = 0.05) but showed no significant association with mean wall thickness (1.19 mm, p = 0.61) and no significant differences in the proportions of mural elastin and collagen (p = 0.19) between younger (<50 years) and older (>50) ex vivo samples. We conclude that age-related stiffening of the PPA differs from that of the aorta; microstructural remodeling, rather than changes in overall geometry, may explain age-related stiffening.


Asunto(s)
Envejecimiento , Arteria Pulmonar , Rigidez Vascular , Humanos , Arteria Pulmonar/fisiología , Anciano , Masculino , Femenino , Persona de Mediana Edad , Adulto , Envejecimiento/fisiología , Anciano de 80 o más Años , Adolescente , Rigidez Vascular/fisiología , Adulto Joven , Elastina/metabolismo
4.
Magn Reson Med ; 92(5): 1838-1850, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38817154

RESUMEN

PURPOSE: Tricuspid valve flow velocities are challenging to measure with cardiovascular MR, as the rapidly moving valvular plane prohibits direct flow evaluation, but they are vitally important to diastolic function evaluation. We developed an automated valve-tracking 2D method for measuring flow through the dynamic tricuspid valve. METHODS: Nine healthy subjects and 2 patients were imaged. The approach uses a previously trained deep learning network, TVnet, to automatically track the tricuspid valve plane from long-axis cine images. Subsequently, the tracking information is used to acquire 2D phase contrast (PC) with a dynamic (moving) acquisition plane that tracks the valve. Direct diastolic net flows evaluated from the dynamic PC sequence were compared with flows from 2D-PC scans acquired in a static slice localized at the end-systolic valve position, and also ventricular stroke volumes (SVs) using both planimetry and 2D PC of the great vessels. RESULTS: The mean tricuspid valve systolic excursion was 17.8 ± 2.5 mm. The 2D valve-tracking PC net diastolic flow showed excellent correlation with SV by right-ventricle planimetry (bias ± 1.96 SD = -0.2 ± 10.4 mL, intraclass correlation coefficient [ICC] = 0.92) and aortic PC (-1.0 ± 13.8 mL, ICC = 0.87). In comparison, static tricuspid valve 2D PC also showed a strong correlation but had greater bias (p = 0.01) versus the right-ventricle SV (10.6 ± 16.1 mL, ICC = 0.61). In most (8 of 9) healthy subjects, trace regurgitation was measured at begin-systole. In one patient, valve-tracking PC displayed a high-velocity jet (380 cm/s) with maximal velocity agreeing with echocardiography. CONCLUSION: Automated valve-tracking 2D PC is a feasible route toward evaluation of tricuspid regurgitant velocities, potentially solving a major clinical challenge.


Asunto(s)
Aprendizaje Profundo , Imagen por Resonancia Cinemagnética , Válvula Tricúspide , Humanos , Válvula Tricúspide/diagnóstico por imagen , Masculino , Femenino , Adulto , Imagen por Resonancia Cinemagnética/métodos , Velocidad del Flujo Sanguíneo , Persona de Mediana Edad , Diástole , Procesamiento de Imagen Asistido por Computador/métodos , Volumen Sistólico/fisiología , Interpretación de Imagen Asistida por Computador/métodos , Algoritmos , Reproducibilidad de los Resultados , Sístole/fisiología
5.
Radiol Cardiothorac Imaging ; 6(2): e230198, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38512023

RESUMEN

Purpose To investigate whether the peak early filling rate normalized to the filling volume (PEFR/FV) estimated from four-dimensional (4D) flow cardiac MRI may be used to assess impaired left ventricular (LV) filling and predict clinical outcomes in individuals with hypertrophic cardiomyopathy (HCM). Materials and Methods Cardiac MRI with a 4D flow sequence and late gadolinium enhancement (LGE), as well as echocardiography, was performed in 88 individuals: 44 participants with HCM from a French prospective registry (ClinicalTrials.gov; NCT01091480) and 44 healthy volunteers matched for age and sex. In participants with HCM, a composite primary end point was assessed at follow-up, including unexplained syncope, new-onset atrial fibrillation, hospitalization for congestive heart failure, ischemic stroke, sustained ventricular arrhythmia, septal reduction therapy, and cardiac death. A Cox proportional hazard model was used to analyze associations with the primary end point. Results PEFR/FV was significantly lower in the HCM group (mean age, 51.8 years ± 18.5 [SD]; 29 male participants) compared with healthy volunteers (mean, 3.35 sec-1 ± 0.99 [0.90-5.20] vs 4.42 sec-1 ± 1.68 [2.74-11.86]; P < .001) and correlated with both B-type natriuretic peptide (BNP) level (r = -0.31; P < .001) and the ratio of pulsed Doppler early transmitral inflow to Doppler tissue imaging annulus velocities (E/E'; r = -0.54; P < .001). At a median follow-up of 2.3 years (IQR, 1.7-3.3 years), the primary end point occurred in 14 (32%) participants. A PEFR/FV of 2.61 sec-1 or less was significantly associated with occurrence of the primary end point (hazard ratio, 9.46 [95% CI: 2.61, 45.17; P < .001] to 15.21 [95% CI: 3.51, 80.22; P < .001]), independently of age, BNP level, E/E', LGE extent, and LV and left atrial strain according to successive bivariate models. Conclusion In HCM, LV filling evaluated with 4D flow cardiac MRI correlated with Doppler and biologic indexes of diastolic dysfunction and predicted clinical outcomes. Keywords: Diastolic Function, Left Ventricular Filling, Hypertrophic Cardiomyopathy, Cardiac MRI, 4D Flow Sequence Clinical trial registration no. NCT01091480 Supplemental material is available for this article. © RSNA, 2024.


Asunto(s)
Cardiomiopatía Hipertrófica , Medios de Contraste , Masculino , Humanos , Persona de Mediana Edad , Gadolinio , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Imagen por Resonancia Magnética , Pronóstico , Atrios Cardíacos
6.
Int J Cardiovasc Imaging ; 40(1): 107-117, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37857929

RESUMEN

A relationship between left atrial strain and pressure has been demonstrated in many studies, but not in an atrial fibrillation (AF) cohort. In this work, we hypothesized that elevated left atrial (LA) tissue fibrosis might mediate and confound the LA strain vs. pressure relationship, resulting instead in a relationship between LA fibrosis and stiffness index (mean LA pressure/LA reservoir strain). Sixty-seven patients with AF underwent a standard cardiac MR exam including long-axis cine views (2 and 4-ch) and a free-breathing high resolution three-dimensional late gadolinium enhancement (LGE) of the atrium (N = 41), within 30 days prior to AF ablation, at which procedure invasive mean left atrial pressure (LAP) was measured. LV and LA Volumes, EF, and comprehensive analysis of LA strains (strain and strain rates and strain timings during the atrial reservoir, conduit and active, i.e. active atrial contraction, phases) were measured and LA fibrosis content (LGE (ml)) was assessed from 3D LGE volumes. LA LGE was well correlated to atrial stiffness index overall (R = 0.59, p < 0.001), and among patient subgroups. Pressure was only correlated to maximal LA volume (R = 0.32) and the time to peak reservoir strain rate (R = 0.32) (both p < 0.01), among all functional measurements. LA reservoir strain was strongly correlated with LAEF (R = 0.95, p < 0.001) and LA minimum volume (r = 0.82, p < 0.001). In our AF cohort, pressure is correlated to maximum LA volume and time to peak reservoir strain. LA pressure/ LA reservoir strain, a metric of stiffness, correlates with LA fibrosis (LA LGE), reflecting Hook's Law.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico por imagen , Medios de Contraste , Valor Predictivo de las Pruebas , Gadolinio , Atrios Cardíacos , Imagen por Resonancia Magnética , Fibrosis
7.
Magn Reson Med ; 91(3): 911-925, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37927206

RESUMEN

PURPOSE: Diastolic function evaluation requires estimates of early and late diastolic mitral filling velocities (E and A) and of mitral annulus tissue velocity (e'). We aimed to develop an MRI method for simultaneous all-in-one diastolic function evaluation in a single scan by generating a 2D phase-contrast (PC) sequence with balanced steady-state free precession (bSSFP) contrast (PC-SSFP). E and A could then be measured with PC, and e' estimated by valve tracking on the magnitude images, using an established deep learning framework. METHODS: Our PC-SSFP used in-plane flow-encoding, with zeroth and first moment nulling over each TR. For further acceleration, different k-t principal component analysis (PCA) methods were investigated with both retrospective and prospective undersampling. PC-SSFP was compared to separate balanced SSFP cine and PC-gradient echo acquisitions in phantoms and in 10 healthy subjects. RESULTS: Phantom experiments showed that PC-SSFP measured accurate velocities compared to PC-gradient echo (r = 0.98 for a range of pixel-wise velocities -80 cm/s to 80 cm/s). In subjects, PC-SSFP generated high SNR and myocardium-blood contrast, and excellent agreement for E (limits of agreement [LOA] 0.8 ± 2.4 cm/s, r = 0.98), A (LOA 2.5 ± 4.1 cm/s, r = 0.97), and e' (LOA 0.3 ± 2.6 cm/s, r = 1.00), versus the standard methods. The best k-t PCA approach processed the complex difference data and substituted in raw k-space data. With prospective k-t PCA acceleration, higher frame rates were achieved (50 vs. 25 frames per second without k-t PCA), yielding a 13% higher e'. CONCLUSION: The proposed PC-SSFP method achieved all-in-one diastolic function evaluation.


Asunto(s)
Imagen por Resonancia Magnética , Humanos , Análisis de Componente Principal , Estudios Retrospectivos , Estudios Prospectivos , Imagen por Resonancia Magnética/métodos , Diástole
8.
Res Sq ; 2023 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-37131741

RESUMEN

Aims: A relationship between left atrial strain and pressure has been demonstrated in many studies, but not in an atrial fibrillation (AF) cohort. In this work, we hypothesized that elevated left atrial (LA) tissue fibrosis might mediate and confound the LA strain vs. pressure relationship, resulting instead in a relationship between LA fibrosis and stiffness index (mean pressure/LA reservoir strain). Methods and Results: Sixty-seven patients with AF underwent a standard cardiac MR exam including long-axis cine views (2 and 4-ch) and a free-breathing high resolution three-dimensional late gadolinium enhancement (LGE) of the atrium (N=41), within 30 days prior to AF ablation, at which procedure invasive mean left atrial pressure (LAP) was measured. LV and LA Volumes, EF, and comprehensive analysis of LA strains (strain and strain rates and strain timings during the atrial reservoir, conduit and active phases) were measured and LA fibrosis content (LGE (ml)) was assessed from 3D LGE volumes. LA LGE was well correlated to atrial stiffness index (LA mean pressure/LA reservoir strain) overall (R=0.59, p<0.001), and among patient subgroups. Pressure was only correlated to maximal LA volume (R=0.32) and the time to peak reservoir strain rate (R=0.32), among all functional measurements. LA reservoir strain was strongly correlated with LAEF (R=0.95, p<0.001) and LA minimum volume (r=0.82, p<0.001). Conclusion: In our AF cohort, pressure is correlated to maximum LA volume and time to peak reservoir strain. LA LGE is a strong marker of stiffness.

9.
Radiol Cardiothorac Imaging ; 5(1): e220160, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36860830

RESUMEN

Purpose: To evaluate a cardiac MRI feature tracking (FT)-derived parameter that combines right ventricular (RV) longitudinal and radial motions in detecting arrhythmogenic right ventricular cardiomyopathy (ARVC). Materials and Methods: Patients with ARVC (n = 47; median age, 46 [IQR, 30-52] years; 31 men) were compared with controls (n = 39; median age, 46 [IQR, 33-53] years; 23 men) and separated into two groups based on fulfillment of major structural 2020 International criteria. Cine data from 1.5-T cardiac MRI examinations were analyzed using FT, resulting in conventional strain parameters and a novel composite index named the longitudinal-to-radial strain loop (LRSL). Receiver operating characteristic (ROC) analysis was used to assess diagnostic performance of RV parameters. Results: Volumetric parameters differed significantly between patients in the major structural criteria group and controls but not between patients in the no major structural criteria group and controls. Patients in the major structural criteria group had significantly lower magnitudes of all FT parameters than controls, including RV basal longitudinal strain, radial motion fraction, circumferential strain, and LRSL (-15.6% ± 6.4 vs -26.7% ± 13.9; -9.6% ± 4.89 vs -13.8% ± 4.7; -6.9% ± 4.6 vs -10.1% ± 3.8; and 217.0 ± 128.9 versus 618.6 ± 356.3, respectively). Only LRSL differed between patients in the no major structural criteria group and controls (359.5 ± 195.8 vs 618.6 ± 356.3; P < .0001). Parameters with the highest area under the ROC curve values for discriminating patients in the no major structural criteria group from controls were LRSL, RV ejection fraction, and RV basal longitudinal strain (0.75, 0.70, and 0.61, respectively). Conclusion: A new parameter combining RV longitudinal and radial motions showed good diagnostic performance in ARVC, even in patients without major structural abnormalities.Keywords: Arrhythmogenic Right Ventricular Dysplasia, Strain, Wall Motion Abnormalities, Right Ventricle, MRI, Inherited Cardiomyopathy Supplemental material is available for this article. © RSNA, 2023.

10.
J Magn Reson Imaging ; 58(3): 782-791, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-36373998

RESUMEN

BACKGROUND: Balanced steady-state free precession (bSSFP) is important in cardiac MRI but suffers from off-resonance artifacts. The interpretation-limiting artifacts in patients with cardiac implants remain an unsolved issue. PURPOSE: To develop an interleaved radial linear combination bSSFP (lcSSFP) method with partial dephasing (PD) for improved cardiac cine imaging when implanted cardiovascular devices are present. STUDY TYPE: Prospective. PHANTOM AND SUBJECTS: Flow phantom adjacent to a pacemaker and 10 healthy volunteers (mean age ± standard deviation: 31.9 ± 2.9 years, 4 females) with a cardioverter-defibrillator (ICD) positioned extracorporeally at the left chest in the prepectoral region. FIELD STRENGTH/SEQUENCE: A 3-T, 1) Cartesian bSSFP, 2) Cartesian gradient echo (GRE), 3) Cartesian lcSSFP, and 4) radial lcSSFP cine sequences. ASSESSMENT: Flow artifacts mitigation using PD was validated with phantom experiments. Undersampled radial lcSSFP with interleaving across phase-cyclings and cardiac phases (RLC-SSFP), combined with PD, was then employed for achieving improved quality of cine images from left ventricular short-axis view. The image quality in the presence of cardiac devices was qualitatively assessed by three independent raters (1 = worst, 5 = best), regarding five criteria (banding artifacts, streak artifacts, flow artifacts, cavity visibility, and overall image quality). STATISTICAL TESTS: Wilcoxon rank-sum test for the five criteria between Cartesian bSSFP cine and RLC-SSFP with PD. Fleiss kappa test for inter-reader agreement. A P value < 0.05 was considered statistically significant. RESULTS: Based on simulations and phantom experiments, 60 projections per phase cycling and 1/6 PD were chosen. The in vivo experiments demonstrated significantly reduced banding artifacts (4.8 ± 0.4 vs. 2.7 ± 0.7), fewer streak artifacts (3.7 ± 0.6 vs. 2.6 ± 0.7) and flow artifacts (4.4 ± 0.4 vs. 3.7 ± 0.6), therefore improved cavity visibility (4.1 ± 0.4 vs. 2.9 ± 0.9) and overall quality (4.0 ± 0.4 vs. 2.7 ± 0.7). DATA CONCLUSION: RLC-SSFP method with PD may improve cine image quality in subjects with cardiac devices. EVIDENCE LEVEL: 2. TECHNICAL EFFICACY: Stage 1.


Asunto(s)
Corazón , Imagen por Resonancia Cinemagnética , Femenino , Humanos , Imagen por Resonancia Cinemagnética/métodos , Estudios Prospectivos , Corazón/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Ventrículos Cardíacos , Artefactos , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA