Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Vasc Surg ; 40(4): 768-73, 2004 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-15472607

RESUMEN

OBJECTIVE: Circulating 8-iso-prostaglandin F 2alpha (8-iso-PGF 2alpha ) has been proposed as new indicator of oxidative stress, which is involved in the pathophysiologic changes of atherosclerosis. We proposed to test the hypothesis that 8-iso-PGF 2alpha is an independent predictor of symptomatic peripheral arterial disease (PAD). METHODS: A case-control study in 100 patients with symptomatic PAD and 100 control subjects matched for age, sex, and diabetes mellitus was conducted. Smokers and subjects using lipid-lowering drugs were excluded. Serum total 8-iso-PGF 2alpha was quantified with an enzyme immunoassay. RESULTS: Median 8-iso-PGF 2alpha was higher in patients with PAD than in control subjects (63 vs 42 pg/mL; P = .001). Logistic regression with hypertension, body mass index, and creatinine, low-density lipoprotein (LDL) cholesterol, triglyceride, high-sensitivity C-reactive protein (hs-CRP), 8-iso-PGF 2alpha , and total homocysteine concentrations as independent variables and case-control status as dependent variable revealed significant odds ratios (OR) for hypertension (OR, 3.74; 95% confidence interval [CI], 1.85-7.53), low-density lipoprotein cholesterol (OR, 1.16, for an increment of 10 mg/dL; 95% CI, 1.07-1.27), high-sensitivity C-reactive protein (OR, 1.02, for an increment of 1 mg/L; 95% CI, 1.00-1.03), and 8-iso-PGF 2alpha (OR, 1.11, for an increment of 10 pg/mL; 95% CI, 1.03-1.20). CONCLUSIONS: Serum total 8-iso-PGF 2alpha was an independent predictor of PAD in the population studied. This finding supports the hypothesis that 8-iso-PGF 2alpha is a risk marker for PAD. Our results indicate increased systemic oxidative stress in patients with PAD.


Asunto(s)
Arteriosclerosis/sangre , Dinoprost/sangre , Enfermedades Vasculares Periféricas/sangre , Anciano , Anciano de 80 o más Años , Arteriosclerosis/metabolismo , Biomarcadores/sangre , Estudios de Casos y Controles , Dinoprost/análogos & derivados , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estrés Oxidativo/fisiología , Enfermedades Vasculares Periféricas/metabolismo , Valor Predictivo de las Pruebas
2.
J Environ Monit ; 1(5): 417-22, 1999 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-11529157

RESUMEN

The realisation of an opto-chemical ammonia sensor suitable for personal monitoring tasks is described, comprising a cyanine dye immobilised in a microporous glass thin film. The fabrication of sensor platforms incorporating embossed grating couplers provides a compact optical design with effective waveguiding characteristics, resulting in reversible ammonia sensitivity in the 5-100 ppm range in under 2 min. Cross-sensitivity of sensor response with water and other potential interferents is considered.


Asunto(s)
Contaminación del Aire Interior/análisis , Amoníaco/análisis , Monitoreo del Ambiente/instrumentación , Exposición Profesional , Diseño de Equipo , Humanos , Óptica y Fotónica , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA