Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Nutrients ; 12(12)2020 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-33255790

RESUMEN

Hypoxia induced by low O2 pressure is responsible for several physiological and behavioral alterations. Changes in physiological systems are frequent, including inflammation and psychobiological declines such as mood and cognition worsening, resulting in increased reaction time, difficulty solving problems, reduced memory and concentration. The paper discusses the possible relationship between glutamine supplementation and worsening cognition mediated by inflammation induced by high altitude hypoxia. The paper is a narrative literature review conducted to verify the effects of glutamine supplementation on psychobiological aspects. We searched MEDLINE/PubMed and Web of Science databases and gray literature by Google Scholar for English articles. Mechanistic pathways mediated by glutamine suggest potential positive effects of its supplementation on mood and cognition, mainly its potential effect on inflammation. However, clinical studies are scarce, making any conclusions impossible. Although glutamine plays an important role and seems to mitigate inflammation, clinical studies should test this hypothesis, which will contribute to a better mood and cognition state for several people who suffer from problems mediated by hypoxia.


Asunto(s)
Afecto/efectos de los fármacos , Altitud , Cognición/efectos de los fármacos , Glutamina/administración & dosificación , Glutamina/farmacología , Hipoxia , Suplementos Dietéticos , Humanos
2.
Artículo en Inglés | MEDLINE | ID: mdl-22845621

RESUMEN

A pre-concentration procedure with solid-phase extraction was developed for the determination of arsenic (As) in chicken feed using hydride generation atomic absorption spectrometry (HG-AAS). The procedure was based on the sorption of As(III) ions as complexes with ammonium pyrrolidine dithiocarbamate onto a mini-column packed with polyurethane foam. After pre-concentration, the As was removed from the mini-column by acid solution, and the analyte content in the eluate was measured by HG-AAS. The following main experimental conditions were established: adjustment of the As solution pH with 0.05 mol l⁻¹ HCl, 2.88 × 10⁻³ mol l⁻¹ complexing agent concentration and 6.0 mol l⁻¹ eluting hydrochloric acid concentration. The proposed method produced an enrichment factor of 67, with 0.050 and 0.165 µg g⁻¹ limits of detection and quantification, respectively. The procedure was applied to the determination of As content in two types of chicken feed using the proposed procedure and atomic absorption spectrometry with electrothermal atomisation (ETAAS). The t-test indicated that the results were not significantly different at a confidence level of 95%.


Asunto(s)
Alimentación Animal/análisis , Arsénico/análisis , Contaminantes Ambientales/análisis , Contaminación de Alimentos , Inspección de Alimentos/métodos , Adsorción , Animales , Aniones/química , Arsénico/química , Arsénico/aislamiento & purificación , Brasil , Quelantes/química , Pollos , Contaminantes Ambientales/química , Contaminantes Ambientales/aislamiento & purificación , Hidrógeno/química , Concentración de Iones de Hidrógeno , Límite de Detección , Poliuretanos/química , Pirrolidinas/química , Reproducibilidad de los Resultados , Extracción en Fase Sólida/métodos , Espectrofotometría Atómica/métodos , Tiocarbamatos/química
3.
Anal Chim Acta ; 575(1): 133-7, 2006 Aug 04.
Artículo en Inglés | MEDLINE | ID: mdl-17723582

RESUMEN

The present paper proposes a pre-concentration procedure for determination of lead and iron in several samples by flame atomic absorption spectrometry. In it, lead(II) and iron(III) ions are coprecipitated using the violuric acid-copper(II) system as collector. Afterwards, the precipitate is dissolved with 1M HNO3 solution and the metal ions are determined. The optimization step was performed using factorial design involving the variables: pH, violuric acid mass (VA) and copper concentration (Cu). Using the optimized experimental conditions, the proposed procedure allows the determination these metals with detection limits of 0.18 microg L(-1) for iron and 0.16 microg L(-1) for lead. The effects of foreign ions on the pre-concentration procedure were also evaluated and the results demonstrated that this method could be applied for determination of iron and lead in several real samples. The proposed method was successfully applied to the analysis of seawater, urine, mineral water, soil and physiological solution samples. The concentrations of lead and iron achieved in these samples agree well with others data reported in the literature.

4.
Anal Bioanal Chem ; 375(3): 443-9, 2003 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-12589511

RESUMEN

A system for on-line preconcentration and determination of lead by flame atomic absorption spectrometry (FAAS) was proposed. It was based on the sorption of lead(II) ions on a minicolumn of polyurethane foam loaded with 2-(2-thiazolylazo)-5-dimethylaminophenol (TAM). The optimisation step was carried out using two-level full factorial and Doehlert designs for the determination of the optimum conditions for lead preconcentration. The proposed procedure allowed the determination of lead with a detection limit of 2.2 microg L(-1), and a precision, calculated as relative standard deviation (RSD), of 2.4 and 6.8 for a lead concentration of 50.0 and 10.0 microg L(-1), respectively. A preconcentration factor of 45 and a sampling frequency of 27 samples per hour were obtained. The recovery achieved for lead determination in the presence of several cations demonstrated that this procedure has enough selectivity for analysis of environmental samples. The validation was carried out by analysis of certified reference material. This procedure was applied to lead determination in natural food.


Asunto(s)
Plomo/análisis , Espectrofotometría Atómica/métodos , Cationes , Cromatografía , Diseño de Equipo , Análisis de los Alimentos , Sistemas en Línea , Estándares de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Espectrofotometría Atómica/instrumentación , Espectrofotometría Atómica/normas
5.
Talanta ; 50(6): 1253-9, 2000 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-18967821

RESUMEN

A procedure for separation and preconcentration of trace amounts of copper in natural water samples, has been proposed. It is based on the adsorption of copper(II) ions onto a column of Amberlite XAD-2 resin loaded with calmagite reagent. This way amounts of copper within the range from 0.0125 to 25.0 microg, in a sample volume of 25 to 250 ml, and pH from 3.7 to 10.0 was concentrated as calmagite complex in a column of 0.50 g of Amberlite XAD-2 resin. Copper (II) ion was desorpted by using 5.0 ml of 2 mol l(-1) hydrochloric acid. Detection and determination limits of the proposed procedure for 250 ml sample volume were 0.15 and 0.50 microg l(-1), respectively. Selectivity test showed that (in the indicated concentration), calcium(II) (500 mg l(-1)), magnesium(II) (500 mg l(-1)), strontium(II) (50 mg l(-1)), iron(III) (10 mg l(-1)), nickel(II) (10 mg l(-1)), cobalt(II) (10 mg l(-1)), cadmium(II) (10 mg l(-1)) and lead(II) (10 mg l(-1)) did not interfere in copper determination by this procedure. Precision of the method, evaluated as the relative standard deviation by analyzing a series of seven replicates, was 2.42% for a copper mass of 1.0 microg in a sample volume of 100 ml. The accuracy of the proposed procedure was evaluated by means of copper determination in reference biological samples. The achieved results were in good agreement with certified values. The extractor system had a sorption capacity of 1.59 mumol of copper per gram of resin loaded with calmagite. The proposed procedure was applied for copper determination by FAAS in natural water samples. Samples were collected from different places of Salvador city, Bahia, Brazil. The achieved recovery, measured by the standard addition technique, showed that the proposed procedure had good accuracy. A good enrichment factor (50x) and simplicity are the main advantages in this analytical procedure.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...