Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Analyst ; 149(8): 2338-2350, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38323806

RESUMEN

The increased adoption of non-invasive laser-based techniques for analysis of cultural assets has recently called into question the non-invasiveness of the techniques in practical operation. The methods to assess the occurrence of radiation-induced alteration on paintings are very limited and none of them can predict damage. Here we present a novel multimodal imaging approach to understand the time and spatial evolution and types of laser-induced surface alterations, through simultaneous monitoring using visible and near infrared (VIS-NIR) reflectance hyperspectral imaging (HSI) and thermal imaging during Raman spectroscopy. The resultant physical and chemical changes were examined in detail by optical coherence tomography and synchrotron based micro-X-ray powder diffraction. HSI was found to be the most sensitive in detecting laser induced alternations compared with conventional methods. It is orders of magnitude more sensitive than Raman spectroscopy and even synchrotron-based micro-X-ray powder diffraction. In cases of thermally driven alterations, transient and reversible reflectance changes were found to be the first indications of laser-induced modifications and can therefore be used as precursors to prevent damage. VIS-NIR reflectance spectroscopy should be used to monitor laser-based analysis and potentially other radiation-based techniques in situ to mitigate laser induced alteration.

2.
Soft Matter ; 20(10): 2381-2393, 2024 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-38376422

RESUMEN

Colloidal suspensions are the basis of a wide variety of coatings, prepared as liquids and then dried into solid films. The processes at play during film formation, however, are difficult to observe directly. Here, we demonstrate that optical coherence tomography (OCT) can provide fast, non-contact, precise profiling of the dynamics within a drying suspension. Using a scanning Michelson interferometer with a broadband laser source, OCT creates cross-sectional images of the optical stratigraphy of a sample. With this method, we observed the drying of colloidal silica in Hele-Shaw cells with 10 µm transverse and 1.8 µm depth resolution, over a 1 cm scan line and a 15 s sampling period. The resulting images were calibrated to show how the concentration of colloidal particles varied with position and drying time. This gives access to important transport properties, for example, of how collective diffusion depends on particle concentration. Looking at early-time behaviours, we also show how a drying front initially develops, and how the induction time before the appearance of a solid film depends on the balance of diffusion and evaporation-driven motion. Pairing these results with optical microscopy and particle tracking techniques, we find that film formation can be significantly delayed by any density-driven circulation occurring near the drying front.

3.
Eur Phys J Plus ; 137(10): 1102, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36213053

RESUMEN

A mobile remote standoff Raman spectroscopy system operational at typical distances of 10 m was developed specifically for research of historical sites and wall paintings recently. Here we present an upgrade to that system informed by a thorough experimental investigation of the relevant laser-induced degradation issues. Reflectance spectroscopy as a more sensitive technique than Raman spectroscopy was used for monitoring and a new phenomenon of reversible alterations was detected in many paint samples at very low laser intensities of less than 1 W/cm2 when Raman measurements detected no changes. Contrary to conventional wisdom, the intensity threshold for safe operation was found to decrease significantly for larger incident irradiation area in the case of a vermilion oil paint sample. Damage threshold in intensity for each material needs to be determined for different spot sizes, which can be orders of magnitude lower for 1 mm spot size compared with micro-Raman. Results from this study is also relevant to portable Raman systems which use similarly large spot sizes. However, the larger spot size still generates more Raman photons overall under safe operation than micro-Raman systems. Continuous-wave (CW) lasers are found to be best suited to efficient, that is more Raman signal detected over a given measurement time, and safe Raman operation than ns-pulse lasers at the same wavelength. While the damage threshold in intensity for ns-pulse lasers is much higher than that of CW lasers, the pulse energy allowed in one pulse for safe operation is still too low to allow detection of Raman signal, and the need for multiple pulses makes pulse laser inefficient owing to the low repetition rate necessary to ensure adequate heat dissipation between pulses. The safety of the upgraded system was evaluated and found that no permanent laser-induced degradation was detected within 60 s of laser irradiation for any of the paint samples.

4.
Micromachines (Basel) ; 12(12)2021 Dec 19.
Artículo en Inglés | MEDLINE | ID: mdl-34945433

RESUMEN

A spatially periodic voltage was used to create a dielectrophoresis induced periodic micro wrinkle deformation on the surface of a liquid film. Optical Coherence Tomography provided the equilibrium wrinkle profile at submicron accuracy. The dynamic wrinkle amplitude was derived from optical diffraction analysis during sub-millisecond wrinkle formation and decay, after abruptly increasing or reducing the voltage, respectively. The decay time constant closely followed the film thickness dependence expected for surface tension driven viscous levelling. Modelling of the system using numerical solution of the Stokes flow equations with electrostatic forcing predicted that wrinkle formation was faster than decay, in accord with observations.

5.
Sci Rep ; 10(1): 19312, 2020 11 09.
Artículo en Inglés | MEDLINE | ID: mdl-33168925

RESUMEN

Automatic remote reflectance spectral imaging of large painted areas in high resolution, from distances of tens of meters, has made the imaging of entire architectural interior feasible. However, it has significantly increased the volume of data. Here we present a machine learning based method to automatically detect 'hidden' writings and map material variations. Clustering of reflectance spectra allowed materials at inaccessible heights to be properly identified by performing non-invasive analysis on regions in the same cluster at accessible heights using a range of complementary spectroscopic techniques. The world heritage site of the Mogao caves, along the ancient Silk Road, consists of 492 richly painted Buddhist cave temples dating from the fourth to fourteenth century. Cave 465 at the northern end of the site is unique in its Indo-Tibetan tantric Buddhist style, and like many other caves, the date of its construction is still under debate. This study demonstrates the powers of an interdisciplinary approach that combines material identification, palaeographic analysis of the revealed Sanskrit writings and archaeological evidence for the dating of the cave temple paintings, narrowing it down to the late twelfth century to thirteenth century.

6.
Opt Express ; 27(22): 31338-31347, 2019 Oct 28.
Artículo en Inglés | MEDLINE | ID: mdl-31684368

RESUMEN

Portable and mobile Raman spectroscopy systems are increasingly being adopted in in situ non-invasive examination of artworks given their high specificity in material identification. However, these systems typically operate within centimeter range working distances, making the examination of large architectural interiors such as wall paintings in churches challenging. We demonstrate the first standoff Raman spectroscopy system for in situ investigation of historic architectural interior at distances > 3 m. The 780 nm continuous wave laser-induced standoff Raman system was successfully deployed for the in situ examination of wall paintings, at distances of 3-15 m, under ambient light. It is able to identify most common pigments while maintaining a very low laser intensity to avoid light induced degradation. It is shown to complement our current method of standoff remote surveys of wall paintings using spectral imaging.

7.
Sci Rep ; 7(1): 15948, 2017 11 21.
Artículo en Inglés | MEDLINE | ID: mdl-29162873

RESUMEN

The bacterial flora of nasogastric feeding tubes and faecal samples were analysed for a low-birth weight (725 g) neonate EGA 25 weeks in intensive care. Samples were collected at age 6 and 8 weeks of life. Optical coherence tomography (OCT) was used to visualise bacterial biofilms inside the nasogastric feeding tubes. The biofilm was heterogeneously distributed along the tube lumen wall, and had a depth of up to 500 µm. The bacterial biofilm and faecal samples included Enterococcus faecalis and Enterobacter hormaechei. Representative strains, recovered from both feeding tubes and faecal samples, were whole genome sequenced using Illumina, Mi-Seq, which revealed indistinguishable strains, each with less than 28 SNP differences, of E. faecalis and E. hormaechei. The E. faecalis strains were from two sequence types (ST191 and ST211) and encoded for a number of traits related to biofilm formation (BopD), adherence (Epb pili), virulence (cps loci, gelatinase, SprE) and antibiotic resistances (IsaA, tetM). The E. hormaechei were all ST106, and encoded for blaACT-15 ß-lactamase and fosfomycin resistance (fosA). This proof of concept study demonstrates that bacterial flora within the neonatal feeding tubes may influence the bacterial colonisation of the intestinal tract and can be visualised non-destructively using OCT.


Asunto(s)
Biopelículas , Nutrición Enteral , Imagenología Tridimensional , Secuenciación Completa del Genoma , Enterobacter/genética , Enterobacter/aislamiento & purificación , Enterococcus faecalis/genética , Enterococcus faecalis/fisiología , Genoma Bacteriano , Humanos , Recién Nacido , Masculino , Filogenia , Polimorfismo de Nucleótido Simple/genética , Tomografía de Coherencia Óptica
8.
Opt Express ; 25(16): 19640-19653, 2017 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-29041156

RESUMEN

This paper examines for the first time the potential complementary imaging capabilities of Optical coherence tomography (OCT) and non-linear microscopy (NLM) for multi-modal 3D examination of paintings following the successful application of OCT to the in situ, non-invasive examination of varnish and paint stratigraphy of historic paintings and the promising initial studies of NLM of varnish samples. OCT provides image contrast through the optical scattering and absorption properties of materials, while NLM provides molecular information through multi-photon fluorescence and higher harmonics generation (second and third harmonic generation). OCT is well-established in the in situ non-invasive imaging of the stratigraphy of varnish and paint layers. While NLM examination of transparent samples such as fresh varnish and some transparent paints showed promising results, the ultimate use of NLM on paintings is limited owing to the laser degradation effects caused by the high peak intensity of the laser source necessary for the generation of non-linear phenomena. The high intensity normally employed in NLM is found to be damaging to all non-transparent painting materials from slightly scattering degraded varnish to slightly absorbing paint at the wavelength of the laser excitation source. The results of this paper are potentially applicable to a wide range of materials given the diversity of the materials encountered in paintings (e.g. minerals, plants, insects, oil, egg, synthetic and natural varnish).

9.
Appl Opt ; 52(14): 3387-93, 2013 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-23669855

RESUMEN

Sandstone is an important cultural heritage material, in both architectural and natural settings, such as neolithic rock art panels. The majority of deterioration effects in porous materials such as sandstone are influenced by the presence and movement of water through the material. The presence of water within the porous network of a material results in changes in the optical coherence tomography signal intensity that can be used to monitor the wetting front of water penetration of dry porous materials at various depths. The technique is able to detect wetting front velocities from 1 cm s(-1) to 10(-6) cm s(-1), covering the full range of hydraulic conductivities likely to occur in natural sandstones from pervious to impervious.

10.
J Colloid Interface Sci ; 395: 287-93, 2013 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-23295027

RESUMEN

In this work, we present the visualization of the internal flows in a drying sessile polymer dispersion drop on hydrophilic and hydrophobic surfaces with Spectral Radar Optical Coherence Tomography (SR-OCT). We have found that surface features such as the initial contact angle and pinning of the contact line, play a crucial role on the flow direction and final shape of the dried drop. Moreover, imaging through selection of vertical slices using optical coherence tomography offers a feasible alternative compared to imaging through selection of narrow horizontal slices using confocal microscopy for turbid, barely transparent fluids.

11.
Appl Opt ; 50(32): 6039-48, 2011 Nov 10.
Artículo en Inglés | MEDLINE | ID: mdl-22083374

RESUMEN

Optical coherence tomography (OCT) has mostly been used for high-speed volume imaging but its profilometry potentials have not been fully exploited. This paper demonstrates high precision (as good as ~50 nm) multi-interface profilometry using a Fourier domain OCT system without special antivibration devices. The precision is up to 2 orders of magnitude better than the depth resolution of the OCT. Detailed analysis of the precision achieved for different surfaces is presented. The multi-interface profiles are obtained as a by-product of the tomography data. OCT has the advantage in speed and sensitivity at detecting rough and internal interfaces versus conventional optical profilometry. An application of the technique to the dynamic monitoring of varnish drying on paintlike substrates is demonstrated, which provides a better understanding of the formation of surface roughness. The technique has potential benefits in the fields of art conservation, coatings technology, and soft matter physics.


Asunto(s)
Aumento de la Imagen/instrumentación , Aumento de la Imagen/métodos , Imagenología Tridimensional/métodos , Tomografía de Coherencia Óptica/instrumentación , Tomografía de Coherencia Óptica/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
12.
Opt Express ; 13(16): 6133-44, 2005 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-19498624

RESUMEN

Optical Coherence Tomography (OCT) is an optical interferometric technique developed mainly for in vivo imaging of the eye and biological tissues. In this paper, we demonstrate the potential of OCT for non-invasive examination of museum paintings. Two en-face scanning OCT systems operating at 850 nm and 1300 nm were used to produce B-scan and C-scan images at typical working distances of 2 cm. The 3D images produced by the OCT systems show not only the structure of the varnish layer but also the paint layers and underdrawings (preparatory drawings under the paint layers). The highest ever resolution and dynamic range images of underdrawings are presented and for the first time it is possible to find out non-invasively on which layer the underdrawings were drawn.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...