Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 14(1): 3777, 2024 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-38355702

RESUMEN

Glaucoma drainage devices (GDDs) are prosthetic-treatment devices for treating primary open-angle glaucoma. Despite their effectiveness in reducing intraocular pressures (IOP), endothelial cell damage (ECD) is a commonly known side-effect. There have been different hypotheses regarding the reasons for ECD with one being an induced increase in shear on the corneal wall. A computational fluid dynamics (CFD) model was used to investigate this hypothesis in silico. The Ahmed Glaucoma Valve (AGV) was selected as the subject of this study using an idealised 3D model of the anterior chamber with insertion angles and positions that are commonly used in clinical practice. It was found that a tube-cornea distance of 1.27 mm or greater does not result in a wall shear stress (WSS) above the limit where ECD could occur. Similarly, a tube-cornea angle of 45° or more was shown to be preferable. It was also found that the ECD region has an irregular shape, and the aqueous humour flow fluctuates at certain insertion angles and positions. This study shows that pathological amounts of WSS may occur as a result of certain GDD placements. Hence, it is imperative to consider the associated fluid force interactions when performing the GDD insertion procedure.


Asunto(s)
Implantes de Drenaje de Glaucoma , Glaucoma de Ángulo Abierto , Glaucoma , Humanos , Glaucoma de Ángulo Abierto/cirugía , Hidrodinámica , Implantes de Drenaje de Glaucoma/efectos adversos , Glaucoma/cirugía , Presión Intraocular , Células Endoteliales , Resultado del Tratamiento , Estudios Retrospectivos , Estudios de Seguimiento , Implantación de Prótesis
2.
Micromachines (Basel) ; 12(9)2021 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-34577675

RESUMEN

Electroosmotic flow (EOF) involving displacement of multiple fluids is employed in micro-/nanofluidic applications. There are existing investigations on EOF hysteresis, i.e., flow direction-dependent behavior. However, none so far have studied the solution pair system of dissimilar ionic species with substantial pH difference. They exhibit complicated hysteretic phenomena. In this study, we investigate the EOF of sodium bicarbonate (NaHCO3, alkaline) and sodium chloride (NaCl, slightly acidic) solution pair via current monitoring technique. A developed slip velocity model with a modified wall condition is implemented with finite element simulations. Quantitative agreements between experimental and simulation results are obtained. Concentration evolutions of NaHCO3-NaCl follow the dissimilar anion species system. When NaCl displaces NaHCO3, EOF reduces due to the displacement of NaHCO3 with high pH (high absolute zeta potential). Consequently, NaCl is not fully displaced into the microchannel. When NaHCO3 displaces NaCl, NaHCO3 cannot displace into the microchannel as NaCl with low pH (low absolute zeta potential) produces slow EOF. These behaviors are independent of the applied electric field. However, complete displacement tends to be achieved by lowering the NaCl concentration, i.e., increasing its zeta potential. In contrast, the NaHCO3 concentration has little impact on the displacement process. These findings enhance the understanding of EOF involving solutions with dissimilar pH and ion species.

3.
Micromachines (Basel) ; 11(11)2020 Oct 29.
Artículo en Inglés | MEDLINE | ID: mdl-33138301

RESUMEN

Electroosmotic flow (EOF) is fluid flow induced by an applied electric field, which has been widely employed in various micro-/nanofluidic applications. Past investigations have revealed that the presence of nanostructures in microchannel reduces EOF. Hitherto, the angle-dependent behavior of nanoline structures on EOF has not yet been studied in detail and its understanding is lacking. Numerical analyses of the effect of nanoline orientation angle θ on EOF to reveal the associated mechanisms were conducted in this investigation. When θ increases from 5° to 90° (from parallel to perpendicular to the flow direction), the average EOF velocity decreases exponentially due to the increase in distortion of the applied electric field distribution at the structured surface, as a result of the increased apparent nanolines per unit microchannel length. With increasing nanoline width W, the decrease of average EOF velocity is fairly linear, attributed to the simultaneous narrowing of nanoline ridge (high local fluid velocity region). While increasing nanoline depth D results in a monotonic decrease of the average EOF velocity. This reduction stabilizes for aspect ratio D/W > 0.5 as the electric field distribution distortion within the nanoline trench remains nearly constant. This investigation reveals that the effects on EOF of nanolines, and by extrapolation for any nanostructures, may be directly attributed to their effects on the distortion of the applied electric field distribution within a microchannel.

4.
Adv Healthc Mater ; 8(6): e1801022, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30511823

RESUMEN

Microarrays are widely used in high-throughput analysis of DNA, protein, and small molecules. However, the majority of microarray assays need improved assay speed and sensitivity due to the slow molecular diffusion from bulk solutions to probe surfaces. Here, a new class of magnetic nanomixers in DNA and protein microarray assays is reported to eliminate the diffusion constraint through dynamic mixing. It is demonstrated that the dynamic nanomixers can improve the assay kinetics at least by a factor of 4 and 2 for DNA and protein microarray assays, respectively. By using the dynamic nanomixers, the sensitivities of detecting Escherichia coli O157:H7 DNA and prostate specific antigen increase by more than four-fold. The dynamic mixing also greatly reduces the spot-to-spot variation to below 10% across a broad concentration range, providing more accurate assay results. In comparison with existing methods, this magnetic nanomixer-based approach offers rapid turnaround, improved sensitivity, good accuracy, low cost, simple operation, and excellent compatibility with commercial microarrays.


Asunto(s)
Magnetismo , Análisis por Micromatrices/métodos , Nanoestructuras/química , ADN Bacteriano/análisis , Difusión , Escherichia coli O157/genética , Humanos , Cinética , Antígeno Prostático Específico/análisis
5.
Micromachines (Basel) ; 9(5)2018 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-30424162

RESUMEN

Although electroosmotic flow (EOF) has been applied to drive fluid flow in microfluidic chips, some of the phenomena associated with it can adversely affect the performance of certain applications such as electrophoresis and ion preconcentration. To minimize the undesirable effects, EOF can be suppressed by polymer coatings or introduction of nanostructures. In this work, we presented a novel technique that employs the Dry Etching, Electroplating and Molding (DEEMO) process along with reactive ion etching (RIE), to fabricate microchannel with black silicon nanostructures (prolate hemispheroid-like structures). The effect of black silicon nanostructures on EOF was examined experimentally by current monitoring method, and numerically by finite element simulations. The experimental results showed that the EOF velocity was reduced by 13 ± 7%, which is reasonably close to the simulation results that predict a reduction of approximately 8%. EOF reduction is caused by the distortion of local electric field at the nanostructured surface. Numerical simulations show that the EOF velocity decreases with increasing nanostructure height or decreasing diameter. This reveals the potential of tuning the etching process parameters to generate nanostructures for better EOF suppression. The outcome of this investigation enhances the fundamental understanding of EOF behavior, with implications on the precise EOF control in devices utilizing nanostructured surfaces for chemical and biological analyses.

6.
Anal Chem ; 89(17): 9394-9399, 2017 09 05.
Artículo en Inglés | MEDLINE | ID: mdl-28737036

RESUMEN

Electroosmotic flow (EOF) or electro-osmosis has been shown to exhibit a hysteresis effect under displacement flow involving two solutions with different concentrations, i.e. the flow velocity for a high-concentration solution displacing a low-concentration solution is faster than the flow velocity in the reverse direction involving the same solution pair. On the basis of our recent numerical analysis, a pH change initiated at the interface between the two solutions has been hypothesized as the cause for the observed anomalies. We report the first experimental evidence of EOF hysteresis induced by a pH change in the bulk solution. pH-sensitive dye was employed to quantify the pH changes in the microchannel during EOF. The electric-field gradient across the boundary of two solutions generates an accumulation or depletion of a minority of pH-governing ions such as hydronium (H3O+) ions, thus inducing pH variations across the microchannel. When a high-concentration solution displaced a lower-concentration solution, a pH increase was observed, while the flow in the reverse direction induced a decrease in pH. This effect causes significant changes to the zeta potential and flow velocity. The experimental results show good quantitative agreement with numerical simulations. This work presents the experimental proof which validates the hypothesis of a pH change during electroomostic flow hysteresis as predicted by numerical analysis. The understanding of pH changes during EOF is crucial for accurate flow manipulation in microfluidic devices and maintenance of constant pH in biological and chemical systems under an electric field.

7.
Nanotechnology ; 28(25): 255303, 2017 Jun 23.
Artículo en Inglés | MEDLINE | ID: mdl-28510536

RESUMEN

Electroosmotic flow (EOF) is an electric-field-induced fluid flow that has numerous micro-/nanofluidic applications, ranging from pumping to chemical and biomedical analyses. Nanoscale networks/structures are often integrated in microchannels for a broad range of applications, such as electrophoretic separation of biomolecules, high reaction efficiency catalytic microreactors, and enhancement of heat transfer and sensing. Their introduction has been known to reduce EOF. Hitherto, a proper study on the effect of nanostructures orientation on EOF in a microfluidic channel is yet to be carried out. In this investigation, we present a novel fabrication method for nanostructure designs that possess maximum orientation difference, i.e. parallel versus perpendicular indented nanolines, to examine the effect of nanostructures orientation on EOF. It consists of four phases: fabrication of silicon master, creation of mold insert via electroplating, injection molding with cyclic olefin copolymer, and thermal bonding and integration of practical inlet/outlet ports. The effect of nanostructures orientation on EOF was studied experimentally by current monitoring method. The experimental results show that nanolines which are perpendicular to the microchannel reduce the EOF velocity significantly (approximately 20%). This flow velocity reduction is due to the distortion of local electric field by the perpendicular nanolines at the nanostructured surface as demonstrated by finite element simulation. In contrast, nanolines which are parallel to the microchannel have no effect on EOF, as it can be deduced that the parallel nanolines do not distort the local electric field. The outcomes of this investigation contribute to the precise control of EOF in lab-on-chip devices, and fundamental understanding of EOF in devices which utilize nanostructured surfaces for chemical and biological analyses.

8.
Anal Chem ; 88(16): 8064-73, 2016 08 16.
Artículo en Inglés | MEDLINE | ID: mdl-27426052

RESUMEN

Electroosmotic flow (EOF) with two or more fluids is often encountered in various microfluidic applications. However, no investigation has hitherto been conducted to investigate the hysteretic or flow direction-dependent behavior during displacement flow of solutions with dissimilar anion species. In this investigation, EOF of dissimilar anionic solutions was studied experimentally through the current monitoring method and numerically through finite element simulations. As opposed to other conventional displacement flows, EOF involving dissimilar anionic solutions exhibits counterintuitive behavior, whereby the current-time curve does not reach the steady-state value of the displacing electrolyte. Two distinct mechanics have been identified as the causes for this observation: (a) ion concentration adjustment when the displacing anions migrate upstream against EOF due to competition between the gradients of electromigrative and convective fluxes and (b) ion concentration readjustment induced by the static diffusive interfacial region between the dissimilar fluids which can only be propagated throughout the entire microchannel with the presence of EOF. The resultant ion distributions lead to the flow rate to be directional-dependent, indicating that the flow conditions are asymmetric between these two different flow directions. The outcomes of this investigation contribute to the in-depth understanding of flow behavior in microfluidic systems involving inhomogeneous fluids, particularly dissimilar anionic solutions. The understanding of EOF hysteresis is fundamentally important for the accurate prediction of analytes transport in microfluidic devices under EOF.

9.
Sci Rep ; 6: 22329, 2016 Feb 29.
Artículo en Inglés | MEDLINE | ID: mdl-26923197

RESUMEN

Electro-osmotic flow, the driving of fluid at nano- or micro-scales with electric field, has found numerous applications, ranging from pumping to chemical and biomedical analyses in micro-devices. Electro-osmotic flow exhibits a puzzling hysteretic behavior when two fluids with different concentrations displace one another. The flow rate is faster when a higher concentration solution displaces a lower concentration one as compared to the flow in the reverse direction. Although electro-osmotic flow is a surface phenomenon, rather counter intuitively we demonstrate that electro-osmotic flow hysteresis originates from the accumulation or depletion of pH-governing minority ions in the bulk of the fluid, due to the imbalance of electric-field-induced ion flux. The pH and flow velocity are changed, depending on the flow direction. The understanding of electro-osmotic flow hysteresis is critical for accurate fluid flow control in microfluidic devices, and maintaining of constant pH in chemical and biological systems under an electric field.

10.
Biomicrofluidics ; 9(2): 024113, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25945139

RESUMEN

Electroosmotic flow (EOF) with two or more fluids is commonly encountered in various microfluidics applications. However, no investigation has hitherto been conducted to investigate the hysteretic or flow direction-dependent behavior during the displacement flow of solutions with dissimilar ionic species. In this investigation, electroosmotic displacement flow involving dissimilar ionic solutions was studied experimentally through a current monitoring method and numerically through finite element simulations. The flow hysteresis can be characterized by the turning and displacement times; turning time refers to the abrupt gradient change of current-time curve while displacement time is the time for one solution to completely displace the other solution. Both experimental and simulation results illustrate that the turning and displacement times for a particular solution pair can be directional-dependent, indicating that the flow conditions in the microchannel are not the same in the two different flow directions. The mechanics of EOF hysteresis was elucidated through the theoretical model which includes the ionic mobility of each species, a major governing parameter. Two distinct mechanics have been identified as the causes for the EOF hysteresis involving dissimilar ionic solutions: the widening/sharpening effect of interfacial region between the two solutions and the difference in ion concentration distributions (and thus average zeta potentials) in different flow directions. The outcome of this investigation contributes to the fundamental understanding of flow behavior in microfluidic systems involving solution pair with dissimilar ionic species.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...