Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros











Intervalo de año de publicación
1.
Ciênc. rural ; Ciênc. rural (Online);45(5): 858-866, 05/2015. graf
Artículo en Inglés | LILACS | ID: lil-745830

RESUMEN

Brachiaria (signalgrass) is now the most widely used tropical grass genus in Central and South America. However, Brachiaria spp. can cause hepatogenous photosensitization in livestock. Steroidal saponins, specifically protodioscin, present in Brachiaria spp. may be responsible for liver injury and subsequent photosensitization. The objective of this study was to determine the effect of ensiling Brachiaria decumbens and Brachiaria brizantha or making hay from Brachiaria decumbens on the concentrations of steroidal saponin in these grasses. Brachiaria grass had no detectable levels of the saponin protodioscin after 24 days of ensiling. In addition, in Brachiaria decumbens, the concentration of the protodioscin decreased 48% over the first three days after haymaking and then remained constant. These results suggest that livestock consuming Brachiaria either as silage or hay may have reduced risk of intoxication by protodioscin. .


Brachiaria atualmente é o gênero de gramínea tropical mais amplamente utilizado na América Central e do Sul. Entretanto, as espécies de Brachiaria podem causar fotossensibilização hepatógena em animais de produção. Saponinas esteroides, especificamente protodioscina, presentes em Brachiaria, podem ser responsáveis pelo dano hepático e consequentemente fotossensibilização. O objetivo deste estudo foi determinar o efeito da ensilagem de Brachiaria decumbens e Brachiaria brizantha e fenação de Brachiaria decumbens sobre a concentração de saponina esteroide. As amostras de Brachiaria ensiladas não tiveram concentrações detectáveis de saponina protodioscina depois de 24 dias de ensilagem. Assim como em Brachiaria decumbens, a concentração de protodioscina reduziu 48% nos três primeiros dias após a fenação e posteriormente manteve-se constante. Estes resultados sugerem que animais de produção, ao consumirem Brachiaria tanto como silagem ou feno, podem ter o risco de intoxicação por protodioscina reduzido.

2.
Ci. Rural ; 45(5): 858-866, 05/2015. graf
Artículo en Inglés | VETINDEX | ID: vti-7894

RESUMEN

Brachiaria (signalgrass) is now the most widely used tropical grass genus in Central and South America. However, Brachiaria spp. can cause hepatogenous photosensitization in livestock. Steroidal saponins, specifically protodioscin, present in Brachiaria spp. may be responsible for liver injury and subsequent photosensitization. The objective of this study was to determine the effect of ensiling Brachiaria decumbens and Brachiaria brizantha or making hay from Brachiaria decumbens on the concentrations of steroidal saponin in these grasses. Brachiaria grass had no detectable levels of the saponin protodioscin after 24 days of ensiling. In addition, in Brachiaria decumbens, the concentration of the protodioscin decreased 48% over the first three days after haymaking and then remained constant. These results suggest that livestock consuming Brachiaria either as silage or hay may have reduced risk of intoxication by protodioscin. .(AU)


Brachiaria atualmente é o gênero de gramínea tropical mais amplamente utilizado na América Central e do Sul. Entretanto, as espécies de Brachiaria podem causar fotossensibilização hepatógena em animais de produção. Saponinas esteroides, especificamente protodioscina, presentes em Brachiaria, podem ser responsáveis pelo dano hepático e consequentemente fotossensibilização. O objetivo deste estudo foi determinar o efeito da ensilagem de Brachiaria decumbens e Brachiaria brizantha e fenação de Brachiaria decumbens sobre a concentração de saponina esteroide. As amostras de Brachiaria ensiladas não tiveram concentrações detectáveis de saponina protodioscina depois de 24 dias de ensilagem. Assim como em Brachiaria decumbens, a concentração de protodioscina reduziu 48% nos três primeiros dias após a fenação e posteriormente manteve-se constante. Estes resultados sugerem que animais de produção, ao consumirem Brachiaria tanto como silagem ou feno, podem ter o risco de intoxicação por protodioscina reduzido.(AU)


Asunto(s)
/efectos adversos , Ensilaje/toxicidad , Saponinas/toxicidad , Poaceae
3.
Acta Cir Bras ; 25(4): 337-41, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20676491

RESUMEN

PURPOSE: To verify if the composit poli (2-hydroxyethyl methacrylate)-PolyHEMA/polypropylene mesh implanted in the female rat's abdominal wall could be suitable for the prevention of peritoneal adhesions, and for the evaluation of the tecidual response produced by this biomaterial. METHODS: Polypropylene meshes (Group PP, n=20) and polypropylene meshes coated with a layer of poli (2-hydroxyethyl methacrylate)-PolyHEMA (Group PH, n=20) were implanted on the abdominal wall of Wistar female rats. Ten animals from each group were submitted to euthanasia at 15 and 30 days of the postoperative period. RESULTS: The animals from the group PP presented visceral adhesions on the mesh surface, which was not observed in the ones from group PH. At the histopathological examination foreign body response was observed in both groups, whilst there was a greater intensity of inflammatory response in group PH on both moments. CONCLUSION: The poli (2-hydroxyethyl methacrylate) polyHEMA hydrogel associated to polypropylene mesh reduces visceral adhesion formation in rats, although it may be associated to greater inflammatory reaction.


Asunto(s)
Pared Abdominal/cirugía , Implantes Experimentales , Enfermedades Peritoneales/prevención & control , Peritoneo/efectos de los fármacos , Polipropilenos/efectos adversos , Mallas Quirúrgicas/efectos adversos , Pared Abdominal/patología , Animales , Materiales Biocompatibles , Femenino , Reacción a Cuerpo Extraño/etiología , Reacción a Cuerpo Extraño/patología , Inflamación/patología , Enfermedades Peritoneales/etiología , Peritoneo/patología , Polihidroxietil Metacrilato/efectos adversos , Ratas , Ratas Wistar , Técnicas de Sutura , Adherencias Tisulares/patología , Adherencias Tisulares/prevención & control
4.
Acta cir. bras ; Acta cir. bras;25(4): 337-341, July-Aug. 2010. ilus
Artículo en Inglés | LILACS | ID: lil-553240

RESUMEN

PURPOSE: To verify if the composit poli (2-hydroxyethyl methacrylate)-PolyHEMA/polypropylene mesh implanted in the female rat's abdominal wall could be suitable for the prevention of peritoneal adhesions, and for the evaluation of the tecidual response produced by this biomaterial. METHODS: Polypropylene meshes (Group PP, n=20) and polypropylene meshes coated with a layer of poli (2-hydroxyethyl methacrylate)-PolyHEMA (Group PH, n=20) were implanted on the abdominal wall of Wistar female rats. Ten animals from each group were submitted to euthanasia at 15 and 30 days of the postoperative period. RESULTS: The animals from the group PP presented visceral adhesions on the mesh surface, which was not observed in the ones from group PH. At the histopathological examination foreign body response was observed in both groups, whilst there was a greater intensity of inflammatory response in group PH on both moments. CONCLUSION: The poli (2-hydroxyethyl methacrylate) polyHEMA hydrogel associated to polypropylene mesh reduces visceral adhesion formation in rats, although it may be associated to greater inflammatory reaction.


OBJETIVO: Verificar se compósito poli 2-hidroxietil dimetacrilato (PoliHEMA) / tela de polipropileno implantado na parede abdominal de ratas seria adequado para prevenção de aderências peritoneais e avaliar a resposta tecidual desencadeada por este biomaterial. MÉTODOS: Foram implantadas telas de polipropileno - Grupo PP (n=20) e telas de polipropileno revestidas por uma camada de poli 2 (hidroxietil dimetacrilato)-PolyHEMA - Grupo PH (n=20) na parede abdominal de ratas da linhagem Wistar. Dez animais de cada grupo foram submetidos à eutanásia aos 15 e 30 dias de pós-operatório. RESULTADOS: Os animais do grupo PP apresentaram aderências viscerais na superfície da tela, o que não foi observado nos do grupo PH. Observou-se no exame histopatológico resposta tipo corpo estranho nos dois grupos sendo que no grupo PH houve maior intensidade de resposta inflamatória nos dois momentos. CONCLUSÃO: O hidrogel de poliHEMA quando associado à tela de polipropileno reduz a formação de aderências viscerais em ratos, embora possa estar associado à reação inflamatória mais intensa.


Asunto(s)
Animales , Femenino , Ratas , Pared Abdominal/cirugía , Implantes Experimentales , Enfermedades Peritoneales/prevención & control , Peritoneo/efectos de los fármacos , Polipropilenos/efectos adversos , Mallas Quirúrgicas/efectos adversos , Pared Abdominal/patología , Materiales Biocompatibles , Reacción a Cuerpo Extraño/etiología , Reacción a Cuerpo Extraño/patología , Inflamación/patología , Enfermedades Peritoneales/etiología , Peritoneo/patología , Polihidroxietil Metacrilato/efectos adversos , Ratas Wistar , Técnicas de Sutura , Adherencias Tisulares/patología , Adherencias Tisulares/prevención & control
5.
Acta cir. bras. ; 25(4): 337-341, July-Aug. 2010. ilus
Artículo en Inglés | VETINDEX | ID: vti-7654

RESUMEN

PURPOSE: To verify if the composit poli (2-hydroxyethyl methacrylate)-PolyHEMA/polypropylene mesh implanted in the female rat's abdominal wall could be suitable for the prevention of peritoneal adhesions, and for the evaluation of the tecidual response produced by this biomaterial. METHODS: Polypropylene meshes (Group PP, n=20) and polypropylene meshes coated with a layer of poli (2-hydroxyethyl methacrylate)-PolyHEMA (Group PH, n=20) were implanted on the abdominal wall of Wistar female rats. Ten animals from each group were submitted to euthanasia at 15 and 30 days of the postoperative period. RESULTS: The animals from the group PP presented visceral adhesions on the mesh surface, which was not observed in the ones from group PH. At the histopathological examination foreign body response was observed in both groups, whilst there was a greater intensity of inflammatory response in group PH on both moments. CONCLUSION: The poli (2-hydroxyethyl methacrylate) polyHEMA hydrogel associated to polypropylene mesh reduces visceral adhesion formation in rats, although it may be associated to greater inflammatory reaction.(AU)


OBJETIVO: Verificar se compósito poli 2-hidroxietil dimetacrilato (PoliHEMA) / tela de polipropileno implantado na parede abdominal de ratas seria adequado para prevenção de aderências peritoneais e avaliar a resposta tecidual desencadeada por este biomaterial. MÉTODOS: Foram implantadas telas de polipropileno - Grupo PP (n=20) e telas de polipropileno revestidas por uma camada de poli 2 (hidroxietil dimetacrilato)-PolyHEMA - Grupo PH (n=20) na parede abdominal de ratas da linhagem Wistar. Dez animais de cada grupo foram submetidos à eutanásia aos 15 e 30 dias de pós-operatório. RESULTADOS: Os animais do grupo PP apresentaram aderências viscerais na superfície da tela, o que não foi observado nos do grupo PH. Observou-se no exame histopatológico resposta tipo corpo estranho nos dois grupos sendo que no grupo PH houve maior intensidade de resposta inflamatória nos dois momentos. CONCLUSÃO: O hidrogel de poliHEMA quando associado à tela de polipropileno reduz a formação de aderências viscerais em ratos, embora possa estar associado à reação inflamatória mais intensa.(AU)


Asunto(s)
Animales , Femenino , Ratas , Hernia Abdominal/cirugía , Materiales Biocompatibles/uso terapéutico , Mallas Quirúrgicas , Polipropilenos
6.
Acta Cir Bras ; 22(1): 8-11, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17293943

RESUMEN

PURPOSE: To verify whether pediculated diaphragmatic flaps were suitable to correct iatrogenic wounds in dog's esophagus injuries. METHODS: Seven dogs were submitted to resection of a segment of the esophageal wall, which was then corrected by suturing a pediculated diaphragm flap. Endoscopic evaluation of the esophageal wall was done forty days after the surgical procedure. RESULTS: Three animals died, one due to implant ischemia, caused by strangulation of the phrenic artery; other due to wound infection; and the last, due to mediastinitis. Scar retraction was observed, however, there was no stenosis, allowing the passage of a 9,8 mm probe with no difficulty. The limits between the implants and the native esophagus were indistinguishable, and the implant was covered by esophageal mucosa. CONCLUSION: The diaphragmatic flaps are suitable on the restoring of continuity in dog's thoracic esophagus.


Asunto(s)
Diafragma/trasplante , Esofagoplastia/veterinaria , Colgajos Quirúrgicos/veterinaria , Animales , Perros , Estenosis Esofágica/diagnóstico , Estenosis Esofágica/veterinaria , Esofagoplastia/efectos adversos , Esofagoscopía/veterinaria , Cicatrización de Heridas
7.
Acta cir. bras. ; 22(1): 8-11, Jan.-Feb. 2007. ilus
Artículo en Inglés | VETINDEX | ID: vti-2183

RESUMEN

PURPOSE: To verify whether pediculated diaphragmatic flaps were suitable to correct iatrogenic wounds in dog's esophagus injuries. METHODS: Seven dogs were submitted to resection of a segment of the esophagical wall, which was then corrected by suturing a pediculated diaphragm flap. Endoscopic evaluation of the esophagical wall was done forty days after the surgical procedure. RESULTS: Three animals died, one due to implant ischemia, caused by strangulation of the phrenic artery; other due to wound infection; and the last, due to mediastinitis. Scar retraction was observed, however, there was no stenosis, allowing the passage of a 9,8 mm probe with no difficulty. The limits between the implants and the native esophagus were indistinguishable, and the implant was covered by esophageal mucosa. CONCLUSION: The diaphragmatic flaps are suitable on the restoring of continuity in dog's thoracic esophagus.(AU)


OBJETIVO: Verificar se retalhos diafragmáticos pediculados seriam adequados para correção de defeitos iatrogênicos do esôfago do cão. MÉTODOS: Sete cães foram submetidos à ressecção de um segmento da parede esofágica, o qual foi corrigido por meio da sutura de um pedículo diafragmático pediculado. Um animal morreu devido à isquemia do implante causada pelo estrangulamento da artéria frênica, outro devido à infecção da ferida cutânea e outro devido a mediastinite. Aos 40 dias após o procedimento fez-se um exame endoscópico dos animais nos cães sobreviventes. RESULTADOS: Observou-se retração cicatricial sem repercutir em estenose, permitindo a passagem de sonda de 9,8 mm, sem dificuldade. Os limites entre os implantes e o esôfago nativo se apresentaram indistinguíveis e o implante estava recoberto por mucosa esofágica. CONCLUSÃO: Os retalhos diafragmáticos são adequados na restauração da continuidade do esôfago torácico do cão.(AU)


Asunto(s)
Animales , Esofagoplastia/veterinaria , Colgajos Quirúrgicos/veterinaria , Diafragma/trasplante , Perros , Esofagoplastia/efectos adversos , Estenosis Esofágica/diagnóstico , Estenosis Esofágica/veterinaria , Cicatrización de Heridas , Endoscopía
8.
Acta cir. bras ; Acta cir. bras;22(1): 8-11, Jan.-Feb. 2007. ilus
Artículo en Inglés | LILACS | ID: lil-440725

RESUMEN

PURPOSE: To verify whether pediculated diaphragmatic flaps were suitable to correct iatrogenic wounds in dog's esophagus injuries. METHODS: Seven dogs were submitted to resection of a segment of the esophagical wall, which was then corrected by suturing a pediculated diaphragm flap. Endoscopic evaluation of the esophagical wall was done forty days after the surgical procedure. RESULTS: Three animals died, one due to implant ischemia, caused by strangulation of the phrenic artery; other due to wound infection; and the last, due to mediastinitis. Scar retraction was observed, however, there was no stenosis, allowing the passage of a 9,8 mm probe with no difficulty. The limits between the implants and the native esophagus were indistinguishable, and the implant was covered by esophageal mucosa. CONCLUSION: The diaphragmatic flaps are suitable on the restoring of continuity in dog's thoracic esophagus.


OBJETIVO: Verificar se retalhos diafragmáticos pediculados seriam adequados para correção de defeitos iatrogênicos do esôfago do cão. MÉTODOS: Sete cães foram submetidos à ressecção de um segmento da parede esofágica, o qual foi corrigido por meio da sutura de um pedículo diafragmático pediculado. Um animal morreu devido à isquemia do implante causada pelo estrangulamento da artéria frênica, outro devido à infecção da ferida cutânea e outro devido a mediastinite. Aos 40 dias após o procedimento fez-se um exame endoscópico dos animais nos cães sobreviventes. RESULTADOS: Observou-se retração cicatricial sem repercutir em estenose, permitindo a passagem de sonda de 9,8 mm, sem dificuldade. Os limites entre os implantes e o esôfago nativo se apresentaram indistinguíveis e o implante estava recoberto por mucosa esofágica. CONCLUSÃO: Os retalhos diafragmáticos são adequados na restauração da continuidade do esôfago torácico do cão.


Asunto(s)
Animales , Perros , Diafragma/trasplante , Esofagoplastia/veterinaria , Colgajos Quirúrgicos/veterinaria , Endoscopía , Estenosis Esofágica/diagnóstico , Estenosis Esofágica/veterinaria , Esofagoplastia/efectos adversos , Cicatrización de Heridas
9.
Acta Cir Bras ; 20(4): 305-10, 2005.
Artículo en Portugués | MEDLINE | ID: mdl-16186950

RESUMEN

PURPOSE: To compare seringueira latex membrane implant, with and without polylysine at 0.1% and marlex mesh on the repair of iatrogenic abdominal defects in rats. METHODS: A circular segment block of approximate three centimeters of diameter was sectioned out of the ventral abdominal muscle wall of 31 Wistar rats. The skin was preserved. The animals were divided into three experimental groups: only latex, latex and polylysine at 0.1%, and marlex mesh. Some rats underwent euthanasia at five and some at 120 days after surgery. Fragments of abdominal wall were collected and submitted at histopathologic analysis. RESULTS: The main alterations observed in groups treated with the latex membrane with and without polylysine were dehiscence (21 animals) and evisceration (two animals). The elimination of implant occurred at an average of 13.8 days. These animals presented fiber conjunctive tissue formation, similar to that observed in the group which received the marlex mesh. Other alterations noted were viscera-parietal adherences in all evaluated groups. CONCLUSION: The seringueira' s latex membrane, with or without polylysine 0.1%, when used on the reconstruction of abdominal defects in rats is eliminated at 13.8 days after its implantation, leaving a fiber base of reparation, similar to that observed after marlex mesh implantation.


Asunto(s)
Pared Abdominal/patología , Hevea , Látex , Polilisina/uso terapéutico , Polipropilenos/uso terapéutico , Mallas Quirúrgicas , Pared Abdominal/cirugía , Animales , Enfermedad Iatrogénica , Masculino , Prótesis e Implantes , Ratas , Ratas Wistar , Procedimientos de Cirugía Plástica , Factores de Tiempo , Cicatrización de Heridas/fisiología
10.
Acta cir. bras ; Acta cir. bras;20(4): 305-310, July-Aug. 2005. ilus
Artículo en Portugués | LILACS | ID: lil-414201

RESUMEN

OBJETIVO: Comparar o implante de membrana de látex da seringueira sem e com polilisina 0,1 por cento e tela de marlex na reparacão de defeitos abdominais iatrogênicos em ratos. MÉTODOS: Ressectou-se em bloco um segmento circular de aproximadamente três centímetros de diâmetro da parede muscular abdominal ventral de 31 ratos Wistar, preservando-se a pele. Os animais foram divididos em 3 grupos: grupo látex sem polilisina, grupo látex com polilisina 0,1 por cento e grupo marlex. Os animais foram sacrificados aos cinco e aos 120 dias após o procedimento cirúrgico. Fragmentos da parede abdominal foram coletados e submetidos à avaliacão histopatológica. RESULTADOS: As principais alteracões observadas nos grupos tratados com as membranas de látex sem e com polilisina 0,1 por cento foram deiscência (21 animais) e evisceracão (dois animais). A eliminacão dos implantes nos grupos tratados com látex ocorreu, em média, aos 13,8 dias. Nestes animais ocorreu a formacão de tecido conjuntivo fibroso, similar ao observado no grupo que recebeu o marlex. Outras alteracões notadas foram aderências viscero-parietais em todos os grupos avaliados. CONCLUSAO: A membrana de látex da seringueira com e sem polilisina a 0,1 por cento, quando utilizada para reconstrucão de defeitos abdominais em ratos é eliminada, em média, aos 13,8 dias após a sua implantacão, deixando uma base fibrosa de reparacão, similar à observada após a implantacão da tela de marlex.


Asunto(s)
Ratas , Animales , Masculino , Pared Abdominal/patología , Hevea , Látex , Polilisina/farmacología , Polipropilenos/farmacología , Mallas Quirúrgicas , Pared Abdominal/cirugía , Enfermedad Iatrogénica , Prótesis e Implantes , Ratas Wistar , Procedimientos de Cirugía Plástica , Factores de Tiempo , Cicatrización de Heridas/fisiología
11.
Acta cir. bras. ; 20(4): 305-310, jul.-ago. 2005. ilus
Artículo en Portugués | VETINDEX | ID: vti-14242

RESUMEN

OBJETIVO: Comparar o implante de membrana de látex da seringueira sem e com polilisina 0,1 por cento e tela de marlex na reparação de defeitos abdominais iatrogênicos em ratos. MÉTODOS: Ressectou-se em bloco um segmento circular de aproximadamente três centímetros de diâmetro da parede muscular abdominal ventral de 31 ratos Wistar, preservando-se a pele. Os animais foram divididos em 3 grupos: grupo látex sem polilisina, grupo látex com polilisina 0,1 por cento e grupo marlex. Os animais foram sacrificados aos cinco e aos 120 dias após o procedimento cirúrgico. Fragmentos da parede abdominal foram coletados e submetidos à avaliação histopatológica. RESULTADOS: As principais alterações observadas nos grupos tratados com as membranas de látex sem e com polilisina 0,1 por cento foram deiscência (21 animais) e evisceração (dois animais). A eliminação dos implantes nos grupos tratados com látex ocorreu, em média, aos 13,8 dias. Nestes animais ocorreu a formação de tecido conjuntivo fibroso, similar ao observado no grupo que recebeu o marlex. Outras alterações notadas foram aderências viscero-parietais em todos os grupos avaliados. CONCLUSAO: A membrana de látex da seringueira com e sem polilisina a 0,1 por cento, quando utilizada para reconstrução de defeitos abdominais em ratos é eliminada, em média, aos 13,8 dias após a sua implantação, deixando uma base fibrosa de reparação, similar à observada após a implantação da tela de marlex. (AU)


PURPOSE: To compare seringueira latex membrane implant, with and without polilysine at 0.1% and marlex mesh on the repair of iatrogenic abdominal defects in rats.METHODS: A circular segment block of approximate three centimeters of diameter was sectioned out of the ventral adominal muscle wall of 31 Wistar rats. The skin was preserved. The animals were divided into three experimental groups: only latex, latex and polilysine at 0.1%, and marlex mesh. Some rats underwent eutranasia at five and some at 120 days after surgery. Fragments of abdominal wall were collected and submitted at histophatologic analysis.RESULTS: The main alterations observed in groups treated with the latex membrane with and without polilysine were dehiscence (21 animals) and evisceration (two animals). The elimination of implant occurred at an average of 13,8 days. These animals presented fiber conjunctive tissue formation, similar to that observed in the group which received the marlex mesh. Other alterations noted were viscera-parietal adherences in all evaluated groups.CONCLUSION: The seringueira' s latex membrane, with or without polilysine 0,1%, when used on the reconstruction of abdominal defects in rats is eliminated at 13.8 days after its implantation, leaving a fiber base of reparation, similar to that observed after marlex mesh implantation.


Asunto(s)
Animales , Masculino , Ratas , Látex/uso terapéutico , Polilisina/uso terapéutico , Implantes Experimentales , Pared Abdominal/cirugía , Ratas Wistar/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA