Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 237
Filtrar
1.
MMWR Morb Mortal Wkly Rep ; 73(39): 883-887, 2024 Oct 03.
Artículo en Inglés | MEDLINE | ID: mdl-39361547

RESUMEN

Ice machines can harbor water-related organisms, and the use of ice or tap water for clinical care activities has been associated with infections in health care settings. During 2021-2022, a total of 23 cases of infection by Burkholderia multivorans (sequence type ST659) were reported at two southern California hospitals and linked to contaminated ice and water from ice machines. In addition to these 23 cases, this report also includes 23 previously unreported cases of B. multivorans ST659 infections that occurred during 2020-2024: 13 at a northern California hospital, eight at a hospital in Colorado, and two additional cases at one of the southern California hospitals. The same brand of ice machine and brands of filters, descaling, and sanitizing products were used by all four hospitals; B. multivorans was isolated from samples collected from ice machines in two of the hospitals. Whole genome sequencing indicated that all clinical and ice machine isolates were highly genetically similar (0-14 single nucleotide variant differences across 81% of the selected reference genome). Recommendations from public health officials to halt the outbreak included avoiding ice and tap water during clinical care activities. An investigation is ongoing to determine possible sources of ice machine contamination. During outbreaks of water-related organisms in health care facilities, health care personnel should consider avoiding the use of tap water, including ice and water from ice machines, for patient care.


Asunto(s)
Infecciones por Burkholderia , Hospitales , Hielo , Humanos , California/epidemiología , Colorado/epidemiología , Hospitales/estadística & datos numéricos , Infecciones por Burkholderia/epidemiología , Microbiología del Agua , Persona de Mediana Edad , Adulto , Femenino , Masculino , Anciano , Infección Hospitalaria/epidemiología , Infección Hospitalaria/prevención & control , Brotes de Enfermedades , Complejo Burkholderia cepacia/aislamiento & purificación , Adulto Joven , Adolescente , Atención al Paciente , Anciano de 80 o más Años , Niño , Contaminación de Equipos
2.
Appl Environ Microbiol ; 90(9): e0060924, 2024 09 18.
Artículo en Inglés | MEDLINE | ID: mdl-39109876

RESUMEN

Nontuberculous mycobacteria (NTM) in drinking water are a significant public health concern. However, an incomplete understanding of the factors that influence the occurrence of NTM in drinking water limits our ability to characterize risk and prevent infection. This study sought to evaluate the influence of season and water treatment, distribution, and stagnation on NTM in drinking water. Samples were collected source-to-tap in a full-scale, chloraminated drinking water system approximately monthly from December 2019 to November 2020. NTM were characterized using culture-dependent (plate culture with matrix-assisted laser desorption ionization-time-of-flight mass spectrometry [MALDI-TOF MS] isolate analysis) and culture-independent methods (quantitative PCR and genome-resolved metagenomics). Sampling locations included source waters, three locations within the treatment plant, and five buildings receiving water from the distribution system. Building plumbing samples consisted of first draw, 5-min flush, and full flush cold-water samples. As the study took place during the COVID-19 pandemic, the influence of reduced water usage in three of the five buildings was also investigated. The highest NTM densities source-to-tap were found in the summer first draw building water samples (107 gene copies/L), which also had the lowest monochloramine concentrations. Flushing was found to be effective for reducing NTM and restoring disinfectant residuals, though flush times necessary to improve water quality varied by building. Clinically relevant NTM species, including Mycobacterium avium, were recovered via plate culture, with increased occurrence observed in buildings with higher water age. Four of five NTM metagenome-assembled genomes were identified to the species level and matched identified isolates.IMPORTANCENTM infections are increasing in prevalence, difficult to treat, and associated with high morbidity and mortality rates. Our lack of understanding of the factors that influence NTM occurrence in drinking water limits our ability to prevent infections, accurately characterize risk, and focus remediation efforts. In this study, we comprehensively evaluated NTM in a full-scale drinking water system, showing that various steps in treatment and distribution influence NTM presence. Stagnant building water contained the highest NTM densities source-to-tap and was associated with low disinfectant residuals. We illustrated the differences in NTM detection and characterization obtained from culture-based and culture-independent methods, highlighting the complementarity between these approaches. We demonstrated that focusing NTM mitigation efforts in building plumbing systems, which have the highest NTM densities source-to-tap, has potential for immediate positive effects. We also identified steps during treatment that increase NTM levels, which provides beneficial information for utilities seeking to reduce NTM in finished water.


Asunto(s)
Cloraminas , Agua Potable , Micobacterias no Tuberculosas , Purificación del Agua , Agua Potable/microbiología , Micobacterias no Tuberculosas/genética , Micobacterias no Tuberculosas/aislamiento & purificación , Cloraminas/farmacología , Abastecimiento de Agua , Microbiología del Agua , Desinfectantes/farmacología , Estaciones del Año
3.
Clin Microbiol Rev ; 37(3): e0021521, 2024 Sep 12.
Artículo en Inglés | MEDLINE | ID: mdl-39158301

RESUMEN

SUMMARYThis guidance presents recommendations for clinical microbiology laboratories for processing respiratory samples from people with cystic fibrosis (pwCF). Appropriate processing of respiratory samples is crucial to detect bacterial and fungal pathogens, guide treatment, monitor the epidemiology of cystic fibrosis (CF) pathogens, and assess therapeutic interventions. Thanks to CF transmembrane conductance regulator modulator therapy, the health of pwCF has improved, but as a result, fewer pwCF spontaneously expectorate sputum. Thus, the collection of sputum samples has decreased, while the collection of other types of respiratory samples such as oropharyngeal and bronchoalveolar lavage samples has increased. To optimize the detection of microorganisms, including Pseudomonas aeruginosa, Staphylococcus aureus, Haemophilus influenzae, and Burkholderia cepacia complex; other less common non-lactose fermenting Gram-negative bacilli, e.g., Stenotrophomonas maltophilia, Inquilinus, Achromobacter, Ralstonia, and Pandoraea species; and yeasts and filamentous fungi, non-selective and selective culture media are recommended for all types of respiratory samples, including samples obtained from pwCF after lung transplantation. There are no consensus recommendations for laboratory practices to detect, characterize, and report small colony variants (SCVs) of S. aureus, although studies are ongoing to address the potential clinical impact of SCVs. Accurate identification of less common Gram-negative bacilli, e.g., S. maltophilia, Inquilinus, Achromobacter, Ralstonia, and Pandoraea species, as well as yeasts and filamentous fungi, is recommended to understand their epidemiology and clinical importance in pwCF. However, conventional biochemical tests and automated platforms may not accurately identify CF pathogens. MALDI-TOF MS provides excellent genus-level identification, but databases may lack representation of CF pathogens to the species-level. Thus, DNA sequence analysis should be routinely available to laboratories for selected clinical circumstances. Antimicrobial susceptibility testing (AST) is not recommended for every routine surveillance culture obtained from pwCF, although selective AST may be helpful, e.g., for unusual pathogens or exacerbations unresponsive to initial therapy. While this guidance reflects current care paradigms for pwCF, recommendations will continue to evolve as CF research expands the evidence base for laboratory practices.


Asunto(s)
Fibrosis Quística , Infecciones del Sistema Respiratorio , Manejo de Especímenes , Humanos , Fibrosis Quística/microbiología , Fibrosis Quística/complicaciones , Infecciones del Sistema Respiratorio/microbiología , Infecciones del Sistema Respiratorio/diagnóstico , Manejo de Especímenes/métodos , Manejo de Especímenes/normas , Técnicas Microbiológicas/métodos , Técnicas Microbiológicas/normas , Bacterias/aislamiento & purificación , Bacterias/clasificación , Sistema Respiratorio/microbiología , Hongos/aislamiento & purificación , Hongos/clasificación
4.
Curr Microbiol ; 81(9): 273, 2024 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-39017960

RESUMEN

In pharmaceutical manufacturing, ensuring product safety involves the detection and identification of microorganisms with human pathogenic potential, including Burkholderia cepacia complex (BCC), Escherichia coli, Pseudomonas aeruginosa, Salmonella enterica, Staphylococcus aureus, Clostridium sporogenes, Candida albicans, and Mycoplasma spp., some of which may be missed or not identified by traditional culture-dependent methods. In this study, we employed a metagenomic approach to detect these taxa, avoiding the limitations of conventional cultivation methods. We assessed the groundwater microbiome's taxonomic and functional features from samples collected at two locations in the spring and summer. All datasets comprised 436-557 genera with Proteobacteria, Bacteroidota, Firmicutes, Actinobacteria, and Cyanobacteria accounting for > 95% of microbial DNA sequences. The aforementioned species constituted less than 18.3% of relative abundance. Escherichia and Salmonella were mainly detected in Hot Springs, relative to Jefferson, while Clostridium and Pseudomonas were mainly found in Jefferson relative to Hot Springs. Multidrug resistance efflux pumps and BlaR1 family regulatory sensor-transducer disambiguation dominated in Hot Springs and in Jefferson. These initial results provide insight into the detection of specified microorganisms and could constitute a framework for the establishment of comprehensive metagenomic analysis for the microbiological evaluation of pharmaceutical-grade water and other non-sterile pharmaceutical products, ensuring public safety.


Asunto(s)
Bacterias , Agua Subterránea , Metagenómica , Bacterias/genética , Bacterias/clasificación , Bacterias/aislamiento & purificación , Agua Subterránea/microbiología , Microbiota/genética , Preparaciones Farmacéuticas , Metagenoma , Microbiología del Agua
5.
Nat Commun ; 15(1): 4889, 2024 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-38849369

RESUMEN

Polymicrobial infection of the airways is a hallmark of obstructive lung diseases such as cystic fibrosis (CF), non-CF bronchiectasis, and chronic obstructive pulmonary disease. Pulmonary exacerbations (PEx) in these conditions are associated with accelerated lung function decline and higher mortality rates. Understanding PEx ecology is challenged by high inter-patient variability in airway microbial community profiles. We analyze bacterial communities in 880 CF sputum samples collected during an observational prospective cohort study and develop microbiome descriptors to model community reorganization prior to and during 18 PEx. We identify two microbial dysbiosis regimes with opposing ecology and dynamics. Pathogen-governed PEx show hierarchical community reorganization and reduced diversity, whereas anaerobic bloom PEx display stochasticity and increased diversity. A simulation of antimicrobial treatment predicts better efficacy for hierarchically organized communities. This link between PEx, microbiome organization, and treatment success advances the development of personalized clinical management in CF and, potentially, other obstructive lung diseases.


Asunto(s)
Fibrosis Quística , Disbiosis , Microbiota , Esputo , Fibrosis Quística/microbiología , Humanos , Masculino , Esputo/microbiología , Estudios Prospectivos , Femenino , Resultado del Tratamiento , Disbiosis/microbiología , Adulto , Antibacterianos/uso terapéutico , Antibacterianos/farmacología , Pulmón/microbiología , Progresión de la Enfermedad , Enfermedad Pulmonar Obstructiva Crónica/microbiología , Adulto Joven , Adolescente , Bacterias/clasificación , Bacterias/genética , Bacterias/aislamiento & purificación
6.
Water Res ; 257: 121702, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38749337

RESUMEN

While online monitoring of physicochemical parameters has widely been incorporated into drinking water treatment systems, online microbial monitoring has lagged behind, resulting in the use of surrogate parameters (disinfectant residual, applied dose, concentration × time, CT) to assess disinfection system performance. Online flow cytometry (online FCM) allows for automated quantification of total and intact microbial cells. This study sought to investigate the feasibility of online FCM for full-scale drinking water ozone disinfection system performance monitoring. A water treatment plant with high lime solids turbidity in the ozone contactor influent was selected to evaluate the online FCM in challenging conditions. Total and intact cell counts were monitored for 40 days and compared to surrogate parameters (ozone residual, ozone dose, and CT) and grab sample assay results for cellular adenosine triphosphate (cATP), heterotrophic plate counts (HPC), impedance flow cytometry, and 16S rRNA gene sequencing. Online FCM provided insight into the dynamics of the full-scale ozone system, including offering early warning of increased contactor effluent cell concentrations, which was not observed using surrogate measures. Positive correlations were observed between online FCM intact cell counts and cATP levels (Kendall's tau=0.40), HPC (Kendall's tau=0.20), and impedance flow cytometry results (Kendall's tau=0.30). Though a strong correlation between log intact cell removal and CT was not observed, 16S rRNA gene sequencing results showed that passage through the ozone contactor significantly changed the microbial community (p < 0.05). Potential causes of the low overall cell inactivation in the contactor and the significant changes in the microbial community after ozonation include regrowth in the later chambers of the contactor and varied ozone resistance of drinking water microorganisms. This study demonstrates the suitability of direct, online microbial analysis for monitoring full-scale disinfection systems.


Asunto(s)
Desinfección , Agua Potable , Citometría de Flujo , Ozono , Purificación del Agua , Citometría de Flujo/métodos , Desinfección/métodos , Agua Potable/microbiología , Purificación del Agua/métodos
7.
Microbiol Spectr ; 12(6): e0402123, 2024 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-38661349

RESUMEN

A collection of 161 Ralstonia isolates, including 90 isolates from persons with cystic fibrosis, 27 isolates from other human clinical samples, 8 isolates from the hospital environment, 7 isolates from industrial samples, and 19 environmental isolates, was subjected to matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) identification and yielded confident species level identification scores for only 62 (39%) of the isolates, including four that proved misidentified subsequently. Whole-genome sequence analysis of 32 representative isolates for which no confident MALDI-TOF MS species level identification was obtained revealed the presence of seven novel Ralstonia species, including three and four that were isolated from cystic fibrosis or other human clinical samples, respectively, and provided the basis for updating an in-house MALDI-TOF MS database. A reanalysis of all mass spectra with the updated MALDI-TOF MS database increased the percentage of isolates with confident species level identification up to 77%. The antimicrobial susceptibility of 30 isolates mainly representing novel human clinical and environmental Ralstonia species was tested toward 17 antimicrobial agents and demonstrated that the novel Ralstonia species were generally multi-resistant, yet susceptible to trimethoprim/sulfamethoxazole, ciprofloxacin, and tigecycline. An analysis of genomic antimicrobial resistance genes in 32 novel and publicly available genome sequences revealed broadly distributed beta-lactam resistance determinants.IMPORTANCEThe present study demonstrated that a commercial matrix-assisted laser desorption/ionization time-of-flight mass spectrometry identification database can be tailored to improve the identification of Ralstonia species. It also revealed the presence of seven novel Ralstonia species, including three and four that were isolated from cystic fibrosis or other human clinical samples, respectively. An analysis of minimum inhibitory concentration values demonstrated that the novel Ralstonia species were generally multi-resistant but susceptible to trimethoprim/sulfamethoxazole, ciprofloxacin, and tigecycline.


Asunto(s)
Antibacterianos , Pruebas de Sensibilidad Microbiana , Ralstonia , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Humanos , Ralstonia/efectos de los fármacos , Ralstonia/genética , Ralstonia/aislamiento & purificación , Ralstonia/clasificación , Antibacterianos/farmacología , Fibrosis Quística/microbiología , Infecciones por Bacterias Gramnegativas/microbiología , Infecciones por Bacterias Gramnegativas/tratamiento farmacológico , Farmacorresistencia Bacteriana Múltiple/genética , Farmacorresistencia Bacteriana , Genoma Bacteriano/genética , Secuenciación Completa del Genoma
8.
Ann Am Thorac Soc ; 21(4): 595-603, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37963297

RESUMEN

Rationale: Rates of viral respiratory infection (VRI) are similar in people with cystic fibrosis (CF) and the general population; however, the associations between VRI and CF pulmonary exacerbations (PEx) require further elucidation.Objectives: To determine VRI prevalence during CF PEx and evaluate associations between VRI, clinical presentation, and treatment response.Methods: The STOP2 (Standardized Treatment of Pulmonary Exacerbations II) study was a multicenter randomized trial to evaluate different durations of intravenous antibiotic therapy for PEx. In this ancillary study, participant sputum samples from up to three study visits were tested for respiratory viruses using multiplex polymerase chain reactions. Baselines and treatment-associated changes in mean lung function (percent predicted forced expiratory volume in 1 s), respiratory symptoms (Chronic Respiratory Infection Symptom Score), weight, and C-reactive protein were compared as a function of virus detection. Odds of PEx retreatment within 30 days and future PEx hazard were modeled by logistic and Cox proportional hazards regression, respectively.Results: A total of 1,254 sputum samples from 621 study participants were analyzed. One or more respiratory viruses were detected in sputum samples from 245 participants (39.5%). Virus-positive participants were more likely to be receiving CF transmembrane conductance regulator modulator therapy (45% vs. 34%) and/or chronic azithromycin therapy (54% vs. 44%) and more likely to have received treatment for nontuberculous Mycobacterium infection in the preceding 2 years (7% vs. 3%). At study visit 1, virus-positive participants were more symptomatic (mean Chronic Respiratory Infection Symptom Score, 53.8 vs. 51.1), had evidence of greater systemic inflammation (log10 C-reactive protein concentration, 1.32 log10 mg/L vs. 1.23 log10 mg/L), and had a greater drop in percent predicted forced expiratory volume in 1 second from the prior 6-month baseline (5.8 vs. 3.6). Virus positivity was associated with reduced risk of future PEx (hazard ratio, 0.82; 95% confidence interval, 0.69-0.99; P = 0.034) and longer median time to next PEx (255 d vs. 172 d; P = 0.021) compared with virus negativity.Conclusions: More than one-third of STOP2 participants treated for a PEx had a positive test result for a respiratory virus with more symptomatic initial presentation compared with virus-negative participants, but favorable long-term outcomes. More refined phenotyping of PEx, taking VRIs into account, may aid in optimizing personalized management of PEx.Clinical trial registered with www.clinicaltrials.gov (NCT02781610).


Asunto(s)
Fibrosis Quística , Infecciones del Sistema Respiratorio , Virosis , Virus , Humanos , Fibrosis Quística/complicaciones , Fibrosis Quística/epidemiología , Fibrosis Quística/diagnóstico , Proteína C-Reactiva , Prevalencia , Infecciones del Sistema Respiratorio/tratamiento farmacológico , Infecciones del Sistema Respiratorio/epidemiología , Infecciones del Sistema Respiratorio/diagnóstico , Virosis/complicaciones , Virosis/epidemiología , Virosis/diagnóstico , Antibacterianos/uso terapéutico
9.
J Cyst Fibros ; 2023 Nov 10.
Artículo en Inglés | MEDLINE | ID: mdl-37953182

RESUMEN

BACKGROUND: Care guidelines for cystic fibrosis (CF) have been developed to enhance consistent care and to improve health outcomes. We determined if adherence to CF care guidelines predicted P. aeruginosa incidence rates (Pa-IR) at U.S. CF centers in 2018. METHODS: This cross-sectional CF Foundation Patient Registry study included 82 adult and 132 pediatric centers. Adherence to 12 guidelines was defined categorically (guideline met) or as a continuous measure (proportion of patients being treated/evaluated per guideline). Association of adherence to individual guidelines with Pa-IR, accounted for center and patient characteristics relevant to Pa-IR and were modeled using random forests and weighted-least-squares (WLS) analyses. RESULTS: The mean Pa-IR was 0.2 cases/patient-years at risk (SE 0.0074) for all centers combined. Guideline adherence was lowest for ≥4 bacterial cultures/year (54% of centers) and annual oral glucose tolerance test (OGTT) (48% of centers), and highest for annual non-tuberculous mycobacteria (NTM) sputum culture (98%). The mean number of guidelines met was 6.7 and higher for pediatric (7.3) than adult (5.6) centers, (p<0.001). The number of guidelines met correlated negatively with Pa-IR (ß=-0.007, p = 0.043). Macrolide prescription and annual OGTT per guideline were associated with lower and higher Pa-IR, respectively. Centers with lower center-wide lung function, higher proportion of pwCF with low body-mass index, and location in the Southwest had higher Pa-IR. CONCLUSION: Overall adherence to guidelines was high except for performing ≥4 bacterial cultures/year and OGTT. Higher Pa-IR was associated with center characteristics and lower guideline adherence. The lower Pa-IR with greater adherence to guidelines suggests that focusing on quality care can positively impact Pa-IR.

10.
Antimicrob Agents Chemother ; 67(11): e0049823, 2023 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-37768313

RESUMEN

The novel clinical-stage ß-lactam-ß-lactamase inhibitor combination, cefepime-taniborbactam, demonstrates promising activity toward many Gram-negative bacteria producing class A, B, C, and/or D ß-lactamases. We tested this combination against a panel of 150 Burkholderia cepacia complex (Bcc) and Burkholderia gladioli strains. The addition of taniborbactam to cefepime shifted cefepime minimum inhibitory concentrations toward the provisionally susceptible range in 59% of the isolates tested. Therefore, cefepime-taniborbactam possessed similar activity as first-line agents, ceftazidime and trimethoprim-sulfamethoxazole, supporting further development.


Asunto(s)
Complejo Burkholderia cepacia , Burkholderia gladioli , Fibrosis Quística , Humanos , Estados Unidos , Cefepima/farmacología , Antibacterianos/farmacología , Fibrosis Quística/microbiología , Inhibidores de beta-Lactamasas/farmacología , beta-Lactamasas , Pruebas de Sensibilidad Microbiana
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA