Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Clin Transplant ; 35(10): e14429, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34265128

RESUMEN

BACKGROUND: Atrial flutter is the most common arrhythmia post cardiac transplantation. Observational studies in the non-transplant population have shown prognostic benefit with catheter ablation; however, there are no data in the heart transplant population. OBJECTIVES: This study evaluated the experience of catheter ablation in atrial flutter post cardiac transplantation. METHODS: A retrospective review of experience of late onset atrial flutter at the Freeman Hospital, Newcastle-upon-Tyne, UK, between 1985 and January 2020. RESULTS: Sixty eight of the 722 patients who survived 6 months post cardiac transplantation developed late atrial flutter giving an incidence of 9.4%. Thirty-two patients were managed with ablation with treatment largely determined by time of flutter onset. Kaplan Meier estimates for arrhythmia free survival post first ablation for organized atrial arrhythmias was 83.3% at 1 year. Kaplan-Meier estimates for median survival post onset of atrial arrhythmias treated with ablation was 11.34 years (95% CI 8.00-14.57), compared to 5.79 years in patients managed medically (95%CI 2.26-9.32) (P = .026). CONCLUSIONS: Atrial flutter is an important late complication of cardiac transplantation. Patients treated with ablation in the modern era had increased survival compared to a historical cohort.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Trasplante de Corazón , Fibrilación Atrial/cirugía , Aleteo Atrial/etiología , Aleteo Atrial/cirugía , Ablación por Catéter/efectos adversos , Trasplante de Corazón/efectos adversos , Humanos , Pronóstico , Estudios Retrospectivos
2.
Transplantation ; 99(4): 731-45, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25769066

RESUMEN

BACKGROUND: Whether abnormal myocardial perfusion scintigraphy (MPS), dobutamine stress echocardiography (DSE) or coronary angiography, performed during preoperative evaluation for potential kidney transplant recipients, predicts future cardiovascular morbidity is unclear. We assessed test performance for predicting all-cause mortality, cardiovascular mortality and major adverse cardiac events (MACE). METHODS: We searched MEDLINE and EMBASE (to February 2014), appraised studies, and calculated risk differences and relative risk ratios (RRR) with 95% confidence intervals (95% CI) using random effects meta-analysis. RESULTS: Fifty-two studies (7401 participants) contributed data to the meta-analysis. Among the different tests, similar numbers of patients experienced MACE after an abnormal test result compared with a normal result (risk difference: MPS 20 per 100 patients tested [95% CI, 0.11-0.29], DSE 24 [95% CI, 0.10-0.38], and coronary angiography 20 [95% CI, 0.08-0.32; P = 0.91]). Although there was some evidence that coronary angiography was better at predicting all-cause mortality than MPS (RRR, 0.69; 95% CI, 0.49-0.96; P = 0.03) and DSE (RRR, 0.72; 95% CI, 0.50-1.02; P = 0.06), noninvasive tests were as good as coronary angiography at predicting cardiovascular mortality (RRR, MPS, 0.89; 95% CI, 0.38-2.10; P = 0.78; DSE, 1.09; 95% CI, 0.12-10.05; P = 0.93), and MACE (RRR: MPS, 1.09; 95% CI, 0.64-1.86; P = 0.74; DSE, 1.56; 95% CI, 0.71-3.45; P = 0.25). CONCLUSIONS: Noninvasive tests are as good as coronary angiography at predicting future adverse cardiovascular events in advanced chronic kidney disease. However, a substantial number of people with negative test results go on to experience adverse cardiac events.


Asunto(s)
Técnicas de Diagnóstico Cardiovascular , Cardiopatías/diagnóstico , Trasplante de Riñón , Insuficiencia Renal Crónica/cirugía , Receptores de Trasplantes , Distribución de Chi-Cuadrado , Cardiopatías/complicaciones , Cardiopatías/mortalidad , Humanos , Trasplante de Riñón/efectos adversos , Trasplante de Riñón/mortalidad , Oportunidad Relativa , Valor Predictivo de las Pruebas , Insuficiencia Renal Crónica/complicaciones , Insuficiencia Renal Crónica/diagnóstico , Insuficiencia Renal Crónica/mortalidad , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
3.
Am J Kidney Dis ; 57(3): 476-87, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21257239

RESUMEN

BACKGROUND: Cardiovascular disease is the leading cause of death after kidney transplant. Screening for coronary artery disease is integral to pretransplant evaluation, although the relative performance of different tests is uncertain. STUDY DESIGN: Systematic review of diagnostic test accuracy studies using hierarchical summary receiver operating characteristic analysis. SETTING & POPULATION: Kidney transplant candidates undergoing pretransplant assessment. SELECTION CRITERIA OF STUDIES: Studies evaluating the accuracy of screening tests for detecting coronary artery disease. INDEX TESTS: Any non- or minimally invasive test used to diagnose coronary artery disease. REFERENCE TEST: Coronary angiography. RESULTS: 11 studies (690 participants) evaluated dobutamine stress echocardiography; 7 (317 participants), myocardial perfusion scintigraphy; 2 (129 participants), exercise stress electrocardiography; and 2 (121 participants), other tests. Dobutamine stress echocardiography had pooled sensitivity of 0.80 (95% CI, 0.64-0.90) and specificity of 0.89 (95% CI, 0.79-0.94). Myocardial perfusion scintigraphy had pooled sensitivity of 0.69 (95% CI, 0.48-0.85) and specificity of 0.77 (95% CI, 0.59-0.89). Head-to-head comparison of dobutamine stress echocardiography and myocardial perfusion scintigraphy (2 studies; 116 participants) showed that dobutamine stress echocardiography had higher specificity and at least equivalent or higher sensitivity. Indirect comparison suggested dobutamine stress echocardiography may have improved accuracy over myocardial perfusion scintigraphy (P = 0.07). LIMITATIONS: Power to detect differences in accuracy between tests is limited due to sparse data. Absence of significant coronary artery disease may not necessarily correlate with cardiac event-free survival after transplant. CONCLUSIONS: Dobutamine stress echocardiography may perform better than myocardial perfusion scintigraphy; however, additional studies directly comparing dobutamine stress echocardiography and myocardial perfusion scintigraphy are needed. Further research should focus on assessing the ability of functional tests to predict postoperative outcome.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico , Pruebas de Función Cardíaca/normas , Fallo Renal Crónico/cirugía , Trasplante de Riñón , Enfermedad de la Arteria Coronaria/complicaciones , Humanos , Fallo Renal Crónico/complicaciones , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...