Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
ASAIO J ; 2024 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-39088729

RESUMEN

We assessed the prognostic potential of Galectin-3 in a sample of 159 heart failure patients who received a left ventricular assist device (LVAD) implant from 2012 to 2020. Clinical outcomes included hemodynamic data, right heart failure (RHF), hemocompatibility-related adverse events (HRAEs), and mortality. Galectin-3 was compounded into Michigan-RVF and EUROMACS-RHF risk scores and compared to the noncompounded risk scores. Right heart failure was significantly correlated with Galectin (p = 0.004) on a continuous spectrum. Inotrope duration was significantly correlated to Galectin-3 (interquartile range [IQR]: 7.58-8.65, p < 0.001) along with INTERMACS score (IQR: 2.14-1.90, p < 0.001). Intensive care unit length of stay (median 8 days, p = 0.02), blood urea nitrogen (p < 0.001), creatinine (p < 0.001), and pulmonary artery pulsatility index (p = 0.05) were also significantly correlated with Galectin-3. In our c-statistic analysis, the predictive value for RHF improved when Galectin-3 was included for both the Michigan-RVF (0.80-0.86) and EUROMACS-RHF (0.77-0.82) risk scores. When elevated over a binary cutoff of 18.2 ng/ml, Galectin-3 significantly correlated with HRAEs (p = 0.014) and mortality (p = 0.031). Galectin-3 shows great promise as a predictive biomarker in patients implanted with durable LVADs. In addition to significant correlation with key clinical outcomes, Galectin-3 enhanced the Michigan-RVF and EUROMACS-RHF risk scores in predicting progression to RHF.

2.
JACC Cardiovasc Interv ; 16(20): 2498-2510, 2023 10 23.
Artículo en Inglés | MEDLINE | ID: mdl-37804290

RESUMEN

BACKGROUND: The optimal duration of dual antiplatelet therapy (DAPT) after percutaneous coronary intervention (PCI) in patients on long-term oral anticoagulation (OAC) therapy is still uncertain. OBJECTIVES: The aim of this analysis was to assess the effects of 1- vs 3-month DAPT in patients with and those without concomitant OAC included in the XIENCE Short DAPT program. METHODS: The XIENCE Short DAPT program enrolled patients with high bleeding risk who underwent successful PCI with a cobalt-chromium everolimus-eluting stent. DAPT was discontinued at 1 or 3 months in patients free from ischemic events and adherent to treatment. The effect of 1- vs 3-month DAPT was compared in patients with and those without OAC using propensity score stratification. The primary endpoint was all-cause death or any myocardial infarction (MI). The key secondary endpoint was Bleeding Academic Research Consortium (BARC) types 2 to 5 bleeding. Outcomes were assessed from 1 to 12 months after index PCI. RESULTS: Among 3,364 event-free patients, 1,462 (43%) were on OAC. Among OAC patients, the risk for death or MI was similar between 1- and 3-month DAPT (7.4% vs 8.8%; adjusted HR: 0.74; 95% CI: 0.49-1.11; P = 0.139), whereas BARC types 2 to 5 bleeding was lower with 1-month DAPT (adjusted HR: 0.71; 95% CI: 0.51-0.99; P = 0.046). These effects were consistent in patients with and those without OAC (P for interaction = NS). CONCLUSIONS: Between 1 and 12 months after PCI, 1-month compared with 3-month DAPT was associated with similar rates of all-cause death or MI and a reduced rate of BARC types 2 to 5 bleeding, irrespective of OAC treatment.


Asunto(s)
Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Inhibidores de Agregación Plaquetaria/efectos adversos , Stents Liberadores de Fármacos/efectos adversos , Intervención Coronaria Percutánea/efectos adversos , Resultado del Tratamiento , Quimioterapia Combinada , Anticoagulantes/efectos adversos , Infarto del Miocardio/etiología , Hemorragia/inducido químicamente
3.
J Cardiothorac Surg ; 18(1): 117, 2023 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-37038197

RESUMEN

BACKGROUND: While the pledget suture technique has been the standard for surgical aortic. valve replacement (AVR), discussion continues regarding the possibility of the nonpledget suture technique to produce superior structural and hemodynamic parameters. This study aims to assess the effectiveness of the figure-of-eight suture technique in AVR, as determined by the incidence of prosthesis-patient mismatch (PPM). METHODS: We reviewed records of patients (N = 629) who underwent a surgical AVR procedure between January 2011 and July 2018 at a single institution. Indexed effective orifice area values and PPM incidence were calculated from implanted valve size and patient body surface area. Incidence of none, moderate, and severe PPM was compared across AVR suture techniques. RESULTS: A total of 570 pledget and 59 figure-of-eight patients were compared for incidence of PPM. Patients who received AVR with the pledget suture technique had significantly lower echocardiographic measurements of baseline ejection fraction than patients who had received AVR with the figure-of-eight suture technique (p = 0.003). Patients who received the figure-of eight suture had a 14% decrease in moderate PPM compared to patients who received the pledget suture (p = 0.022). Patients who received the figure-of-eight suture also had a significantly higher rate of no PPM (p = 0.044). CONCLUSIONS: The use of the figure-of-eight suture technique in AVR can reduce the incidence of moderate PPM. While the pledget suture is the standard technique in AVR, the figure-of-eight suture technique may offer better structural and hemodynamic outcomes, especially for patients with a smaller aortic annulus.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Diseño de Prótesis , Técnicas de Sutura
4.
Calcif Tissue Int ; 112(4): 472-482, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36725700

RESUMEN

The Src homology region 2 domain-containing phosphatase-1 (SHP-1) is an intracellular tyrosine phosphatase that plays a negative regulatory role in immune cell signaling. Absent or diminished SHP-1 catalytic activity results in reduced bone mass with enhanced bone resorption. Here, we sought to investigate if Shp1 overexpression leads to increased bone mass and improved mechanical properties. Male and female wildtype (WT) and SHP1-transgenic (Tg) mice at 28, 56, and 84 days of age were compared. We applied microcomputed tomography to assess femoral cortical bone geometry and trabecular architecture and 3-point mechanical bending to assess mid-diaphyseal structural and estimated material properties. Serum OPG, RANKL, P1NP, and CTX-1 concentrations were measured by enzyme-linked immunoassay. The majority of transgene effects were restricted to the 28-day-old mice. Trabecular bone volume per total volume, trabecular number, and connectivity density were greater in 28-day-old female SHP1-Tg mice when compared to WTs. SHP1-Tg female mice showed increased total and medullary areas, with no difference in cortical area and thickness. Cortical tissue mineral density was strongly genotype-dependent. Failure load, yield load, ultimate stress, and yield stress were all lower in 28-day-old SHP1-Tg females. In 28-day-old SHP1-Tg females, circulating levels of OPG and P1NP were higher and RANKL levels were lower than WT controls. Our study demonstrates a role for SHP-1 in early postnatal bone development; SHP-1 overexpression negatively impacted whole bone strength and material properties in females.


Asunto(s)
Desarrollo Óseo , Proteínas Tirosina Fosfatasas , Ratones , Masculino , Femenino , Animales , Microtomografía por Rayos X , Proteína Tirosina Fosfatasa no Receptora Tipo 6 , Proteínas Tirosina Fosfatasas/metabolismo , Ratones Transgénicos
5.
ASAIO J ; 69(6): 595-601, 2023 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-36821448

RESUMEN

VISUAL ABSTRACT: of key results. INR, international normalized ratio; TTR, time in therapeutic range; PTR, percentage of tests in range; HRAE, hemocompatibility-related adverse event; FFUV, first follow-up visit; GIB, gastrointestinal bleeding; HR, hazard ratio.http://links.lww.com/ASAIO/A961.


Asunto(s)
Corazón Auxiliar , Warfarina , Humanos , Anticoagulantes/efectos adversos , Coagulación Sanguínea , Relación Normalizada Internacional/métodos , Fenprocumón/efectos adversos , Warfarina/efectos adversos
6.
J Card Surg ; 36(3): 1159-1161, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33533108

RESUMEN

Unplanned readmissions frequently occur following the implantation of a durable left ventricular assist device (LVAD) due to complications such as gastrointestinal bleeding and driveline infection. There is a paucity of literature describing the incidence of unplanned readmission in patients with a HeartMate 3 (HM3) Left Ventricular Assist System. In this report, we present the successful outcome of a patient with an HM3 LVAD who has experienced no unplanned readmissions in the 4-year post-implant phase. To our knowledge, this is the longest readmission-free case after HM3 implantation. A successful patient outcome was enabled by the use of the modular HM3 device, the postoperative prescription of beta-blockers and omega-3, the presence of strong social support, and open communication between the patient's caregivers and the LVAD team. Reducing the instance of unplanned readmission confers clinical benefits to the patient, as well as reducing the cost burden on the patient and the healthcare system.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos , Humanos , Periodo Posoperatorio , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...