Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Braz Dent J ; 30(6): 592-598, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31800754

RESUMEN

This study aimed to evaluate the polymerization properties of bulk-fill materials (low and high-viscosity) by using high-intensity continuous light and intermittent photo-activation in terms of polymerization shrinkage stress and degree of conversion (DC). The following Bulk-fill and Conventional nanofilled resin composites were evaluated: Filtek Z350XT Flow (3M/ESPE), SureFil SDR Flow (Dentsply), Filtek Bulk Fill Flow (3M/ESPE), Filtek Z350XT (3M/ESPE) and Filtek Bulk Fill Posterior (3M/ESPE). A LED device (DB 685, Dabi Atlante) was used for both protocols: continuous uniform and intermittent photo-activation (light-on and light-off cycles) with identical radiant exposure (14 J/cm2). The polymerization shrinkage stress (n=6) was evaluated by inserting a single increment of 12 mm3 between two stainless steel plates (6×2 mm) adapted to a Universal Testing Machine (UTM), at different times. Measurements were recorded after photo-activation. The degree of conversion was evaluated by Fourier transformed infrared spectroscope (FTIR) with an attenuated total reflectance (ATR) accessory (n=5). Data were analyzed by three-way ANOVA and Tukey's HSD (α=0.05) tests. Bulk Fill Posterior presented higher shrinkage stress values when photo-activated with the intermittent technique (p<0.05). The intermittent photo-activation increased the degree of conversion for the low-viscosity bulk-fills (p<0.05). Therefore, the use of modulated photo-activation (intermittent) must be indicated with caution since its use can influence the shrinkage stress and degree of conversion of composites, which varies according to the resin formulations.


Asunto(s)
Resinas Compuestas , Ensayo de Materiales , Polimerizacion , Viscosidad
2.
Braz. dent. j ; Braz. dent. j;30(6): 592-598, Nov.-Dec. 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1055449

RESUMEN

Abstract This study aimed to evaluate the polymerization properties of bulk-fill materials (low and high-viscosity) by using high-intensity continuous light and intermittent photo-activation in terms of polymerization shrinkage stress and degree of conversion (DC). The following Bulk-fill and Conventional nanofilled resin composites were evaluated: Filtek Z350XT Flow (3M/ESPE), SureFil SDR Flow (Dentsply), Filtek Bulk Fill Flow (3M/ESPE), Filtek Z350XT (3M/ESPE) and Filtek Bulk Fill Posterior (3M/ESPE). A LED device (DB 685, Dabi Atlante) was used for both protocols: continuous uniform and intermittent photo-activation (light-on and light-off cycles) with identical radiant exposure (14 J/cm2). The polymerization shrinkage stress (n=6) was evaluated by inserting a single increment of 12 mm3 between two stainless steel plates (6×2 mm) adapted to a Universal Testing Machine (UTM), at different times. Measurements were recorded after photo-activation. The degree of conversion was evaluated by Fourier transformed infrared spectroscope (FTIR) with an attenuated total reflectance (ATR) accessory (n=5). Data were analyzed by three-way ANOVA and Tukey's HSD (α=0.05) tests. Bulk Fill Posterior presented higher shrinkage stress values when photo-activated with the intermittent technique (p<0.05). The intermittent photo-activation increased the degree of conversion for the low-viscosity bulk-fills (p<0.05). Therefore, the use of modulated photo-activation (intermittent) must be indicated with caution since its use can influence the shrinkage stress and degree of conversion of composites, which varies according to the resin formulations.


Resumo O presente estudo teve como objetivo avaliar as propriedades de polimerização de materiais bulk-fill (baixa e alta viscosidade) utilizando luz contínua de alta intensidade e fotoativação intermitente em relação ao estresse de contração de polimerização e grau de conversão (DC). As seguintes resinas compostas Bulk-fill e nanohíbridas convencionais foram avaliadas: Filtek Z350XT Flow (3M/ESPE), SureFil SDR Flow (Dentsply), Filtek Bulk Fill Flow (3M/ESPE), Filtek Z350XT (3M/ESPE) e Filtek Bulk Fill Posterior (3M/ESPE). Um dispositivo de LED (DB 685, Dabi Atlante) foi utilizado nos dois protocolos: fotoativação contínua e intermitente contínua (ciclos de liga e desliga) com exposição idêntica (14 J/cm2). A tensão de contração de polimerização (n=6) foi avaliada através da inserção de um incremento único de 12 mm3 entre duas placas de aço inoxidável (6×2 mm) adaptadas a uma Máquina de Ensaio Universal (UTM), em tempos diferentes. As medições foram registradas após a fotoativação. O grau de conversão foi avaliado por FTIR-ATR (n=5). Os dados foram analisados ​​pelos testes ANOVA a três fatores e teste de Tukey (α=0,05). A resina Bulk Fill Posterior apresentou maiores valores de tensão de contração quando fotoativadas com a técnica intermitente (p<0,05). A fotoativação intermitente aumentou o grau de conversão nas resinas bulk-fill de baixa viscosidade (p<0,05). Portanto, o uso de fotoativação modulada (intermitente) deve ser indicado com cautela, uma vez que seu uso pode influenciar a tensão de contração e o grau de conversão dos compósitos, o que varia de acordo com as formulações da resina.


Asunto(s)
Ensayo de Materiales , Resinas Compuestas , Viscosidad , Polimerizacion
3.
J Appl Oral Sci ; 25(4): 381-386, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28877276

RESUMEN

OBJECTIVE: This study aimed to investigate the effect of laser diode irradiation on the degree of conversion (DC), water sorption (WS), and water solubility (WSB) of these bonding systems in an attempt to improve their physico-mechanical resistance. MATERIAL AND METHODS: Two bonding agents were tested: a two-step total-etch system [Adper™ Single Bond 2, 3M ESPE (SB)] and a universal system [Adper™ Single Bond Universal, 3M ESPE (SU)]. Square-shaped specimens were prepared and assigned into 4 groups (n=5): SB and SU (control groups - no laser irradiation) and SB-L and SU-L [SB and SU laser (L) - irradiated groups]. DC was assessed using Fourier transform infrared spectroscopy with attenuated total reflectance. Additional uncured resin samples (≈3.0 µL, n=5) of each adhesive were also scanned for final DC calculation. For WS/WSB tests, similar specimens (n=10) were prepared and measured by monitoring the mass changes after dehydration/water storage cycles. For both tests, adhesive fluids were dropped into standardized Teflon molds (6.0×6.0×1.0 mm), irradiated with a 970-nm laser diode, and then polymerized with an LED-curing unit (1 W/cm2). RESULTS: Laser irradiation immediately before photopolymerization increased the DC (%) of the tested adhesives: SB-L>SB>SU-L>SU. For WS/WSB (µg/mm3), only the dentin bonding system (DBS) was a significant factor (p<0.05): SB>SU. CONCLUSION: Irradiation with a laser diode improved the degree of conversion of all tested simplified dentin bonding systems, with no impact on water sorption and solubility.


Asunto(s)
Recubrimientos Dentinarios/efectos de la radiación , Láseres de Semiconductores , Polimerizacion/efectos de la radiación , Luces de Curación Dental , Cementos Dentales/química , Cementos Dentales/efectos de la radiación , Recubrimientos Dentinarios/química , Curación por Luz de Adhesivos Dentales/métodos , Transición de Fase/efectos de la radiación , Procesos Fotoquímicos/efectos de la radiación , Valores de Referencia , Reproducibilidad de los Resultados , Solubilidad/efectos de la radiación , Espectroscopía Infrarroja por Transformada de Fourier , Estadísticas no Paramétricas , Propiedades de Superficie/efectos de la radiación
4.
J. appl. oral sci ; J. appl. oral sci;25(4): 381-386, July-Aug. 2017. tab, graf
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-893641

RESUMEN

Abstract Simplified dentin-bonding systems are clinically employed for most adhesive procedures, and they are prone to hydrolytic degradation. Objective This study aimed to investigate the effect of laser diode irradiation on the degree of conversion (DC), water sorption (WS), and water solubility (WSB) of these bonding systems in an attempt to improve their physico-mechanical resistance. Material and Methods Two bonding agents were tested: a two-step total-etch system [Adper™ Single Bond 2, 3M ESPE (SB)] and a universal system [Adper™ Single Bond Universal, 3M ESPE (SU)]. Square-shaped specimens were prepared and assigned into 4 groups (n=5): SB and SU (control groups - no laser irradiation) and SB-L and SU-L [SB and SU laser (L) - irradiated groups]. DC was assessed using Fourier transform infrared spectroscopy with attenuated total reflectance. Additional uncured resin samples (≈3.0 µL, n=5) of each adhesive were also scanned for final DC calculation. For WS/WSB tests, similar specimens (n=10) were prepared and measured by monitoring the mass changes after dehydration/water storage cycles. For both tests, adhesive fluids were dropped into standardized Teflon molds (6.0×6.0×1.0 mm), irradiated with a 970-nm laser diode, and then polymerized with an LED-curing unit (1 W/cm2). Results Laser irradiation immediately before photopolymerization increased the DC (%) of the tested adhesives: SB-L>SB>SU-L>SU. For WS/WSB (μg/mm3), only the dentin bonding system (DBS) was a significant factor (p<0.05): SB>SU. Conclusion Irradiation with a laser diode improved the degree of conversion of all tested simplified dentin bonding systems, with no impact on water sorption and solubility.


Asunto(s)
Recubrimientos Dentinarios/efectos de la radiación , Láseres de Semiconductores , Polimerizacion/efectos de la radiación , Valores de Referencia , Solubilidad/efectos de la radiación , Propiedades de Superficie/efectos de la radiación , Reproducibilidad de los Resultados , Recubrimientos Dentinarios/química , Espectroscopía Infrarroja por Transformada de Fourier , Estadísticas no Paramétricas , Cementos Dentales/efectos de la radiación , Cementos Dentales/química , Transición de Fase/efectos de la radiación , Curación por Luz de Adhesivos Dentales/métodos , Luces de Curación Dental , Procesos Fotoquímicos/efectos de la radiación
5.
Compend Contin Educ Dent ; 38(3): 144-149; quiz 150, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28257221

RESUMEN

Often, young patients (≤30 years old) present with carious lesions that progress acutely, compromising a large amount of tooth structure. In these cases, a treatment to prevent the occurrence of pulp exposure and promote remineralization of caries-affected dentin is necessary to maintain healthy dental structure and allow more conservative interventions. The approach will be different when pulp exposure occurs: The therapeutic treatments will be focused on reparative dentin formation and prevention of microorganisms penetrating the pulp organ. Due to the different possible treatments that can be performed to avoid pulp necrosis and the various materials that can be used for this purpose, professionals may have some difficulties understanding all the indications for conservative pulp treatments. The objective of this article is to describe and discuss a successful pulp capping and stepwise excavation associated with restorative treatment for deep caries lesions of anterior upper teeth.


Asunto(s)
Caries Dental/terapia , Recubrimiento de la Pulpa Dental , Necrosis de la Pulpa Dental/prevención & control , Restauración Dental Permanente/métodos , Niño , Preparación de la Cavidad Dental , Humanos , Masculino , Remineralización Dental
6.
Bauru; s.n; 2017. 120 p. tab, ilus, graf.
Tesis en Portugués | LILACS, BBO - Odontología | ID: biblio-880069

RESUMEN

A irradiação de sistemas adesivos com laser tem obtido resultados promissores, no entanto, seu mecanismo de ação, bem como a longevidade da camada híbrida obtida após a irradiação com laser ainda não estão bem estabelecidos na literatura. A presente tese teve como objetivo: avaliar a absorvância do laser de Diodo por diferentes sistemas adesivos por meio de espectroscopia no infravermelho próximo; avaliar a evaporação de água e solventes proporcionada pelo laser por meio da variação da massa analisada em balança de precisão; avaliar a resistência de união por meio de teste de microtração após envelhecimento de 12 meses. Os dados obtidos foram analisados por modelos de ANOVA, seguidos de teste Tukey (p<0,05) e os resultados demonstraram que: a irradiação no infravermelho próximo, área do espectro eletromagnético que compreende o laser de Diodo, não apresenta interação com os sistemas adesivos testados; o laser de Diodo é capaz de proporcionar maior alteração de massa, mesmo após contínua evaporação dos solventes com jatos de ar por 60s; sistemas adesivos simplificados apresentaram valores de resistência de união imediato semelhantes aos valores obtidos após 12 meses de envelhecimento. Os dados obtidos neste estudo sugerem que a irradiação com laser de Diodo pode contribuir favoravelmente para a adesão em dentina com sistemas adesivos simplificados após 1 ano.(AU)


The laser irradiation of adhesive systems has obtained promising results, however, its mechanism of action, as well as the longevity of the hybrid layer obtained after laser irradiation are still not yet well established in the literature. This thesis aimed to: assess the diode laser interaction with different adhesive systems by means of near infrared spectroscopy; evaluate the evaporation of solvents and water provided by the laser through the mass variation analyzed at a precision balance; evaluate the bond strength through microtensile bond strength test after 12 months of aging. The data was analyzed through ANOVA models, followed by Tukey test (p<0.05), and the results demonstrated that: in the near-infrared irradiation area, the electromagnetic spectrum comprising the diode laser, shows no interaction with the adhesive systems tested; the diode laser was able to provide greater mass variation, even after continual evaporation of solvents with air jets for 60s; simplified adhesive systems presented immediate bond strength values similar to the ones verified after 12 months of aging. The data obtained in this study suggest that the Diode laser irradiation can contribute favorably for the adhesion between dentin and simplified adhesive systems after 1 year.(AU)


Asunto(s)
Recubrimientos Dentinarios/química , Recubrimientos Dentinarios/efectos de la radiación , Láseres de Semiconductores , Análisis de Varianza , Ensayo de Materiales , Valores de Referencia , Reproducibilidad de los Resultados , Espectroscopía Infrarroja por Transformada de Fourier , Propiedades de Superficie , Resistencia a la Tracción/efectos de la radiación , Factores de Tiempo
7.
Full dent. sci ; 8(32): 63-68, 2017. ilus
Artículo en Inglés | BBO - Odontología | ID: biblio-916225

RESUMEN

Tooth wear associated with bone loss, gingival recessions and root exposure of the anterior teeth determine the characteristics of an aged smile. The present clinical case reports the aesthetic treatment of a middle-aged patient who had a prematurely aged smile. After anamnesis and physical examination, it was found that episodes of bone loss had occurred, however, previous periodontal treatment had satisfactorily controlled the disease. And yet it was also observed wear of the upper anterior teeth and fracture on tooth 11. Treatment plan included the confection of direct veneers with composite resin, without the need for tooth structure wear. At the end of the first session, it was observed that although an aesthetic result was already achieved, the ratio of height and width of the incisors had not yet been standardized. Thus, orthodontic rubbers were used for three days for tooth movement and increase of mesiodistal dimension of the central and lateral incisors. The present case demonstrates excellent aesthetic results and patient satisfaction. It was concluded that in the current case report it was possible to satisfactorily rejuvenate smile with direct application of composite resin (AU).


O desgaste dentário associado à perda óssea, recessão gengival e exposição radicular dos dentes anteriores determinam características de um sorriso envelhecido. O presente caso clínico relata o tratamento estético de uma paciente de meia idade, que apresentava sorriso precocemente envelhecido. Após anamnese e exame físico, constatou-se que episódios de perda óssea ocorreram, no entanto, o tratamento periodontal prévio já havia controlado a doença de forma satisfatória. Observou-se ainda desgaste dos dentes anteriores superiores e fratura no elemento ente 11. O plano de tratamento incluiu a realização de facetas diretas de resina composta, sem a necessidade de desgaste da estrutura dentária. Ao final da primeira sessão, observou-se que, apesar de um resultado estético já obtido, a proporção de altura e largura dos incisivos não havia ainda sido normalizada. Assim, borrachas ortodônticas foram utilizadas por três dias para movimentação dos dentes e aumento da dimensão mésio-distal dos incisivos centrais e laterais. Este caso mostra excelentes resultados estéticos e satisfação do paciente. Concluiu-se que, no presente caso clínico, foi possível rejuvenescer o sorriso de forma satisfatória com aplicação de resinas compostas diretas (AU).


Asunto(s)
Humanos , Femenino , Persona de Mediana Edad , Sonrisa , Resinas Compuestas , Coronas con Frente Estético , Estética Dental , Desgaste de los Dientes , Brasil
8.
Braz Dent J ; 27(5): 532-536, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27982229

RESUMEN

This in vitro study evaluated the effect of sodium bicarbonate and sodium ascorbate on the microtensile bond strength of an etch-and-rinse system to bleached bovine enamel. Sixty bovine enamel blocks (4x4 mm) were flattened and randomly allocated into 5 groups: G1 (negative control): without treatment; G2 (positive control): bleached with 35% hydrogen peroxide (HP); G3: bleached and stored for 7 days in artificial saliva before restorative procedures; G4: bleached and treated with 10% sodium bicarbonate solution for 5 min; G5: bleached and treated with 10% sodium ascorbate hydrogel for 15 min. HP gel was applied twice (20 min each, except in G1) and the adhesive restorations were performed. After 24 h, the specimens were sectioned into sticks and submitted to microtensile bond strength testing with a crosshead speed of 0.5 mm/min (n=12). As a complementary visual observation, the enamel surfaces of the G1 and G2 specimens were evaluated with scanning electron microscopy. Data were analyzed by one-way ANOVA (p<0.05). The means (standard deviation) were: G1: 24.22±7.74; G2: 18.29±5.88; G3: 40.88±7.95; G4: 19.95±5.67 and G5: 24.43±6.43. Adhesive failures were predominant in all groups. The comparison between the treatments indicates that waiting 7 days after bleaching is still the most effective approach. When this waiting period is not possible, application of sodium ascorbate or sodium bicarbonate seems to be a good alternative. Therefore, the practicality of obtaining sodium bicarbonate in the bleaching kits and its higher stability enables its clinical use.


Asunto(s)
Antioxidantes/farmacología , Esmalte Dental , Resistencia a la Tracción , Blanqueamiento de Dientes , Animales , Bovinos
9.
Braz. dent. j ; Braz. dent. j;27(5): 532-536, Sept.-Oct. 2016. tab, graf
Artículo en Inglés | LILACS | ID: biblio-828038

RESUMEN

Abstract This in vitro study evaluated the effect of sodium bicarbonate and sodium ascorbate on the microtensile bond strength of an etch-and-rinse system to bleached bovine enamel. Sixty bovine enamel blocks (4x4 mm) were flattened and randomly allocated into 5 groups: G1 (negative control): without treatment; G2 (positive control): bleached with 35% hydrogen peroxide (HP); G3: bleached and stored for 7 days in artificial saliva before restorative procedures; G4: bleached and treated with 10% sodium bicarbonate solution for 5 min; G5: bleached and treated with 10% sodium ascorbate hydrogel for 15 min. HP gel was applied twice (20 min each, except in G1) and the adhesive restorations were performed. After 24 h, the specimens were sectioned into sticks and submitted to microtensile bond strength testing with a crosshead speed of 0.5 mm/min (n=12). As a complementary visual observation, the enamel surfaces of the G1 and G2 specimens were evaluated with scanning electron microscopy. Data were analyzed by one-way ANOVA (p<0.05). The means (standard deviation) were: G1: 24.22±7.74; G2: 18.29±5.88; G3: 40.88±7.95; G4: 19.95±5.67 and G5: 24.43±6.43. Adhesive failures were predominant in all groups. The comparison between the treatments indicates that waiting 7 days after bleaching is still the most effective approach. When this waiting period is not possible, application of sodium ascorbate or sodium bicarbonate seems to be a good alternative. Therefore, the practicality of obtaining sodium bicarbonate in the bleaching kits and its higher stability enables its clinical use.


Resumo Este estudo in vitro avaliou o efeito do bicarbonato de sódio e do ascorbato de sódio na resistência de união de um sistema adesivo convencional unido ao esmalte bovino clareado. Sessenta blocos de esmalte bovino (4x4 mm) foram planificados e distribuídos aleatoriamente em 5 grupos: G1: (controle negativo); G2 (controle positivo): clareamento com peróxido de hidrogênio 35% (HP); G3: clareamento com HP seguido de armazenamento por 7 dias em saliva artificial antes do procedimento restaurador; G4: clareamento com HP seguido de tratamento com a solução de bicarbonato de sódio 10% por 5 min; G5: clareamento com HP seguido de tratamento com hidrogel de ascorbato de sódio 10% por 15 min. O HP foi aplicado duas vezes (20 min cada, com exceção do grupo G1) e então as restaurações adesivas foram realizadas. Após 24 h, os espécimes foram seccionados em palitos e submetidos ao teste de resistência de união a uma velocidade de 0,5 mm/min (n=12). As superfícies de esmalte de G1 e G2 foram avaliadas com microscopia eletrônica de varredura para fins de análise visual complementar. Os dados foram analisados por ANOVA a um critério (p<0,05). As medias (desvio-padrão) foram: G1: 24,22±7,74; G2: 18,29±5,88; G3: 40,88±7,95; G4: 19,95±5,67 e G5: 24,43±6,43. Falhas adesivas foram predominantes em todos os grupos. A comparação entre os diferentes tratamentos indica que esperar 7 dias após o clareamento é ainda a abordagem mais eficaz. Nos casos em que este período de espera não é possível, a aplicação do ascorbato de sódio e do bicarbonate de sódio parecem ser boas alternativas. Entretanto, a praticidade na obtenção da solução de bicarbonato de sódio nos kits de clareamento e sua maior estabilidade favorecem o seu uso clínico.


Asunto(s)
Animales , Bovinos , Antioxidantes/farmacología , Esmalte Dental , Resistencia a la Tracción , Blanqueamiento de Dientes
10.
J Appl Oral Sci ; 24(4): 317-24, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27556201

RESUMEN

OBJECTIVE: This study investigated the effect of the fluorescent dye rhodamine B (RB) for interfacial micromorphology analysis of dental composite restorations on water sorption/solubility (WS/WSL) and microtensile bond strength to dentin (µTBS) of a 3-step total etch and a 2-step self-etch adhesive system. MATERIAL AND METHODS: The adhesives Adper Scotchbond Multi-Purpose (MP) and Clearfil SE Bond (SE) were mixed with 0.1 mg/mL of RB. For the WS/WSL tests, cured resin disks (5.0 mm in diameter x 0.8 mm thick) were prepared and assigned into four groups (n=10): MP, MP-RB, SE, and SE-RB. For µTBS assessment, extracted human third molars (n=40) had the flat occlusal dentin prepared and assigned into the same experimental groups (n=10). After the bonding and restoration procedures, specimens were sectioned in rectangular beams, stored in water and tested after seven days or after 12 months. The failure mode of fractured specimens was qualitatively evaluated under optical microscope (x40). Data from WS/WSL and µTBS were assessed by one-way and three-way ANOVA, respectively, and Tukey's test (α=5%). RESULTS: RB increased the WSL of MP and SE. On the other hand, WS of both MP and SE was not affected by the addition of RB. No significance in µTBS between MP and MP-RB for seven days or one year was observed, whereas for SE a decrease in the µTBS means occurred in both storage times. CONCLUSIONS: RB should be incorporated into non-simplified DBSs with caution, as it can interfere with their physical-mechanical properties, leading to a possible misinterpretation of bonded interface.


Asunto(s)
Recubrimientos Dentinarios/química , Dentina/efectos de los fármacos , Colorantes Fluorescentes/química , Rodaminas/química , Agua/química , Resinas Compuestas/química , Recubrimiento Dental Adhesivo/métodos , Fracaso de la Restauración Dental , Humanos , Ensayo de Materiales , Microscopía Confocal , Reproducibilidad de los Resultados , Cementos de Resina/química , Solubilidad , Propiedades de Superficie , Resistencia a la Tracción , Factores de Tiempo
11.
J. appl. oral sci ; J. appl. oral sci;24(4): 317-324, July-Aug. 2016. tab, graf
Artículo en Inglés | LILACS, BBO - Odontología | ID: lil-792589

RESUMEN

ABSTRACT Objective This study investigated the effect of the fluorescent dye rhodamine B (RB) for interfacial micromorphology analysis of dental composite restorations on water sorption/solubility (WS/WSL) and microtensile bond strength to dentin (µTBS) of a 3-step total etch and a 2-step self-etch adhesive system. Material and Methods The adhesives Adper Scotchbond Multi-Purpose (MP) and Clearfil SE Bond (SE) were mixed with 0.1 mg/mL of RB. For the WS/WSL tests, cured resin disks (5.0 mm in diameter x 0.8 mm thick) were prepared and assigned into four groups (n=10): MP, MP-RB, SE, and SE-RB. For µTBS assessment, extracted human third molars (n=40) had the flat occlusal dentin prepared and assigned into the same experimental groups (n=10). After the bonding and restoration procedures, specimens were sectioned in rectangular beams, stored in water and tested after seven days or after 12 months. The failure mode of fractured specimens was qualitatively evaluated under optical microscope (x40). Data from WS/WSL and µTBS were assessed by one-way and three-way ANOVA, respectively, and Tukey’s test (α=5%). Results RB increased the WSL of MP and SE. On the other hand, WS of both MP and SE was not affected by the addition of RB. No significance in µTBS between MP and MP-RB for seven days or one year was observed, whereas for SE a decrease in the µTBS means occurred in both storage times. Conclusions RB should be incorporated into non-simplified DBSs with caution, as it can interfere with their physical-mechanical properties, leading to a possible misinterpretation of bonded interface.


Asunto(s)
Humanos , Rodaminas/química , Agua/química , Recubrimientos Dentinarios/química , Dentina/efectos de los fármacos , Colorantes Fluorescentes/química , Solubilidad , Propiedades de Superficie , Resistencia a la Tracción , Factores de Tiempo , Ensayo de Materiales , Reproducibilidad de los Resultados , Recubrimiento Dental Adhesivo/métodos , Microscopía Confocal , Resinas Compuestas/química , Cementos de Resina/química , Fracaso de la Restauración Dental
12.
Full dent. sci ; 8(29): 101-108, 2016. ilus
Artículo en Portugués | BBO - Odontología | ID: biblio-909651

RESUMEN

Tratamentos estéticos com demanda por excelência são corriqueiros nas clínicas odontológicas especializadas, sendo cada vez mais procurados e realizados em sessão única de tratamento. Esses procedimentos com sessão única podem ser indicados por imediatismo, urgência dos pacientes ou pela indisponibilidade de locomoção, uma vez que muitos pacientes buscam tratamentos especializados em cidades distantes de suas residências. O presente relato de dois casos clínicos descreve as técnicas e estratégias de tratamento para realização do clareamento dentário e de restaurações adesivas na mesma sessão, por meio da utilização de agentes antioxidantes. O clareamento em consultório foi realizado com gel de peróxido de hidrogênio 35% (Lase peróxido de Flex, DMC), ativado com LED (Laser BrightMax Quattro, MMO). Em função da presença de íons oxigênio na matriz do esmalte e dentina após o clareamento dental, esses íons podem inibir a adequada polimerização dos sistemas adesivos e da resina composta, comprometendo o procedimento restaurador. Sendo água bicarbonatada (Neutralize, Lase peróxido Flex Kit, DMC) aplicada para remover o oxigênio residual, após preparo cavitário e antes do condicionamento ácido e aplicação do adesivo. As restaurações foram realizadas com técnica incremental e resina composta cor A2/B2 de dentina (NG brilhante, Coltene) e A1/B1 de esmalte (NG brilhante, Coltene). Os procedimentos de acabamento e polimento também foram realizados na mesma sessão. Após 3 meses de controle foi possível observar, que em ambos os casos, o tratamento estético obteve bastante sucesso, sem qualquer deterioração visível da interface resina-esmalte (AU).


Aesthetic treatments with demand for excellence are commonplace in specialized dental clinics, increasingly popular and performed in a single treatment session. These procedures performed in a single session may be indicated by immediacy, patients urgency or unavailability of transportation, since many patients seek specialized treatment in cities far away from their homes. This report of two cases describes treatment techniques and strategies to perform dental bleaching and adhesive restorations in the same session through the use of antioxidants. Bleaching was carried out in-office with 35% hydrogen peroxide gel (Lase Peroxide Flex, DMC), activated with LED (Laser BrightMax Quattro, MMO). Due to the presence of oxygen ions in the enamel matrix and dentin after bleaching, these ions can inhibit the proper polymerization of the adhesive systems and composite resin, compromising the restorative procedure. Bicarbonated water (Neutralize, Lase Peroxide Flex Kit, DMC) is applied to remove residual oxygen after cavity preparation and before the acid etching and adhesive application. Restorations were performed with incremental technique and composite dentin color A2/B2 (bright NG, Coltene) and A1/B1 enamel (bright NG, Coltene). Finishing and polishing procedures were also performed in the same session. After 3 months, it was observed that in both cases, the aesthetic treatment achieved great success without any visible deterioration of the resin/enamel interface (AU).


Asunto(s)
Humanos , Femenino , Adulto , Estética Dental , Peróxido de Hidrógeno/efectos adversos , Oxidantes/química , Blanqueamiento de Dientes/métodos , Brasil , Cementos Dentales
13.
Rev. Salusvita (Online) ; 35(1): 119-127, 2016.
Artículo en Portugués | LILACS | ID: lil-788585

RESUMEN

Introdução: todo canal radicular instrumentado, seja por métodos manuais ou rotatórios, apresentará a formação de uma lama de detritos sobre a parede dentinária, sendo esta composta tanto por matéria orgânica quanto inorgânica, denominada de smear layer. Em relação a sua remoção ou manutenção das paredes do canal, diversos autores apresentaram opiniões e resultados divergentes, gerando dúvidas aos clínicos em relação à conduta mais adequada a ser empregada no tratamento endodôntico. Objetivo: este trabalho, por meio de uma revisão de literatura, visa fornecer uma resposta clara, capaz de melhorar o prognóstico do tratamento. Metodologia: para isso, foram utilizados 25 trabalhos desde o ano de 1975 a 2014, coletados por meio das bases de dados PubMed e Web of Science, com as palavras chaves: "smear layer", "smear layer removal", "smear layer permeability", "smear layer bacteria" e "smear layer sealing". Conclusão: baseado na metodologia proposta pode-se concluir que a remoção da smear layer é a melhor conduta a ser tomada durante o tratamento endodôntico, pois proporciona uma ação antimicrobiana mais eficiente das substâncias irrigadoras e medicações intracanais, além de permitir um melhor selamento entre dentina e material obturador, reduzindo as chances de uma infiltração.


Introduction: the root canal instrumentation, either by manual or mechanicals methods, will result in a formation of debris layer on dentin surface composted by organic and inorganic tissues, denominated smear layer. Due to the several divergent opinion about its removal or maintenance into the root canal, the clinicians may have a doubt for the most appropriate conduct to be performed in endodontics treatments. Objective: this article aimed collect the mains results obtained by different authors to provide a clear answer capable of improving the treatment prognosis. Methods: for this, were used 25 articles since 1975 to 2014 collected by date base PubMed and Web of Science with the keywords "smear layer", "smear layer removal", "smear layer permeability", "smear layer bacteria" and "smear layer sealing". Conclusion: based in the informations obtained in this review, its was concluded that the smear layer removal can, not only, improve the antimicrobial action of the irrigants agents and intracanal medicaments, but also provide a most efficient sealing of the fillingmaterial to dentine wall, reducing the chances to occur a leak in its interface.


Asunto(s)
Humanos , Masculino , Femenino , Capa de Barro Dentinario , Permeabilidad de la Dentina , Pronóstico , Endodoncia
14.
Full dent. sci ; 6(22): 151-157, mar. 2015. ilus
Artículo en Portugués | LILACS | ID: lil-754378

RESUMEN

Facetas minimamente invasivas, também conhecidas como ôlentes de contatoõ, têm sido consideradas uma alternativa interessante para tratar problemas estéticos nos dentes anteriores. O presente relato de caso descreve passo a passo o tratamento de diastemas múltiplos com facetas minimamente invasivas, e discute tópicos importantes relacionados a este assunto quanto a indicações, materiais utilizados e longevidade destes tipos de restaurações...


Minimally invasive veneers, also known as ôcontact lensesõ, are being considered an interesting alternative for aesthetic rehabilitation of anterior teeth. This case report describes, step by the step the treatment of multiple diastemas with minimally invasive veneers, and addresses important issues related to this topic concerning indications, materials and longevity of these type of restorations...


Asunto(s)
Humanos , Masculino , Adolescente , Cerámica/química , Blanqueamiento de Dientes/métodos , Diastema , Coronas con Frente Estético , Sonrisa/psicología , Moldes Quirúrgicos , Peróxido de Hidrógeno/química , Diseño Asistido por Computadora/instrumentación
15.
Braz Oral Res ; 29: 1-5, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25466328

RESUMEN

Laser irradiation after the immediate application of dentin bonding systems (DBSs) and prior to their polymerization has been proposed to increase bond strength. The objective of this study was to evaluate the effect of diode laser irradiation (λ = 970 nm) on simplified DBSs through microtensile bond strength tests. Forty healthy human molars were randomly distributed among four groups (n = 10) according to DBSs used [Adper™ SingleBond 2 (SB) and Adper™ EasyOne (EO)], and the respective groups were irradiated with a diode laser (SB-L and EO-L). After bonding procedures and composite resin build-ups, teeth were stored in deionized water for 7 days and then sectioned to obtain stick-shaped specimens (1.0 mm2). The microtensile test was performed at 0.5 mm/min, yielding bond strength values in MPa, which were evaluated by two-way ANOVA followed by Tukey's test (p < 0.05) for individual comparisons. For both adhesive systems, diode laser irradiation promoted significant increases in bond strength values (SB: 33.49 ± 6.77; SB-L: 43.69 ± 8.15; EO: 19.67 ± 5.86; EO-L: 29.87 ± 6.98). These results suggest that diode laser irradiation is a promising technique for achieving better performance of adhesive systems on dentin.


Asunto(s)
Cementos Dentales/química , Recubrimientos Dentinarios/química , Dentina/efectos de la radiación , Láseres de Semiconductores/uso terapéutico , Análisis de Varianza , Resinas Compuestas/química , Recubrimiento Dental Adhesivo/métodos , Humanos , Ensayo de Materiales , Ilustración Médica , Distribución Aleatoria , Valores de Referencia , Reproducibilidad de los Resultados , Propiedades de Superficie/efectos de los fármacos , Resistencia a la Tracción/efectos de la radiación , Factores de Tiempo
16.
Braz Oral Res ; 29: 1-5, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25466330

RESUMEN

Increased surface roughness and wear of resin cements may cause failure of indirect restorations. The aim of this study was to evaluate quantitatively the surface roughness change and the vertical wear of four resin cements subjected to mechanical toothbrushing abrasion. Ten rectangular specimens (15 × 5 × 4 mm) were fabricated according to manufacturer instructions for each group (n = 10): Nexus 3, Kerr (NX3); RelyX ARC, 3M ESPE (ARC); RelyX U100, 3M ESPE (U100); and Variolink II, Ivoclar/Vivadent (VL2). Initial roughness (Ra, µm) was obtained through 5 readings with a roughness meter. Specimens were then subjected to toothbrushing abrasion (100,000 cycles), and further evaluation was conducted for final roughness. Vertical wear (µm) was quantified by 3 readings of the real profile between control and brushed surfaces. Data were subjected to analysis of variance, followed by Tukey's test (p < 0.05). The Pearson correlation test was performed between the surface roughness change and wear (p < 0.05). The mean values of initial/final roughness (Ra, µm)/wear (µm) were as follows: NX3 (0.078/0.127/23.175); ARC (0.086/0.246/20.263); U100 (0.296/0.589/16.952); and VL2 (0.313/0.512/22.876). Toothbrushing abrasion increased surface roughness and wear of all resin cements tested, although no correlation was found between those variables. Vertical wear was similar among groups; however, it was considered high and may lead to gap formation in indirect restorations.


Asunto(s)
Alisadura de la Restauración Dental , Cementos de Resina/química , Abrasión de los Dientes , Cepillado Dental , Análisis de Varianza , Bisfenol A Glicidil Metacrilato/química , Ensayo de Materiales , Polietilenglicoles/química , Ácidos Polimetacrílicos/química , Valores de Referencia , Estadísticas no Paramétricas , Propiedades de Superficie , Factores de Tiempo
17.
Braz. dent. sci ; 18(4): 127-131, 2015. ilus
Artículo en Inglés | LILACS | ID: lil-786302

RESUMEN

Anatomic alterations caused by incisal guide wear, even when small, can cause the aspect of an aged smile. The objective of this clinical case is to reporta highly conservative esthetic treatment performed through the association of in-office bleaching andresin composite veneers. In-office bleaching was performed with 35% hydrogen peroxide, and in the following week, minimal invasive resin composite veneers were installed on the upper incisors and canines. In the next appointment, finishing and polishing were performed with abrasive discs and silicon carbide brushes. The results were considered highly satisfactory, establishing a younger aspectof the patient’s smile. Resin composite veneers are still an excellent alternative for esthetic reanatomizationof anterior teeth, capable of generating optimal results with low costs and time...


Alterações anatômicas causadas pelo desgaste da guia incisal, mesmo quando pequeno, podem causar um aspecto de um sorriso envelhecido. O objetivo deste caso clínico é reportar uma tratamento estético altamente conservativo realizado por meio da associação de clareamento em consultório e facetas de resina composta. O clareamento em consultório foi realizado com peróxido de hidrogênio a 35%,e na semana seguinte, facetas de resina composta minimamente invasivas foram instaladas nos incisivos e caninos superiores. Na próxima consulta, acabamento e polimento foram realizados com discos abrasivos e escova de carbeto de silício. Os resultados foram considerados altamente satisfatórios, estabelecendo um aspecto jovial ao sorriso da paciente. Facetas de resinas compostas são ainda uma excelente alternativa para reanatomização estética dos dentes anteriores, capazes de gerar resultados ótimos com baixo custo e tempo...


Asunto(s)
Humanos , Resinas Compuestas , Coronas con Frente Estético , Estética Dental , Ortodoncia , Blanqueamiento de Dientes
18.
Braz. oral res. (Online) ; 29(1): 1-5, 2015. tab, ilus
Artículo en Inglés | LILACS | ID: lil-777183

RESUMEN

Laser irradiation after the immediate application of dentin bonding systems (DBSs) and prior to their polymerization has been proposed to increase bond strength. The objective of this study was to evaluate the effect of diode laser irradiation (λ = 970 nm) on simplified DBSs through microtensile bond strength tests. Forty healthy human molars were randomly distributed among four groups (n = 10) according to DBSs used [Adper™ SingleBond 2 (SB) and Adper™ EasyOne (EO)], and the respective groups were irradiated with a diode laser (SB-L and EO-L). After bonding procedures and composite resin build-ups, teeth were stored in deionized water for 7 days and then sectioned to obtain stick-shaped specimens (1.0 mm2). The microtensile test was performed at 0.5 mm/min, yielding bond strength values in MPa, which were evaluated by two-way ANOVA followed by Tukey’s test (p < 0.05) for individual comparisons. For both adhesive systems, diode laser irradiation promoted significant increases in bond strength values (SB: 33.49 ± 6.77; SB-L: 43.69 ± 8.15; EO: 19.67 ± 5.86; EO-L: 29.87 ± 6.98). These results suggest that diode laser irradiation is a promising technique for achieving better performance of adhesive systems on dentin.


Asunto(s)
Humanos , Cementos Dentales/química , Recubrimientos Dentinarios/química , Dentina/efectos de la radiación , Láseres de Semiconductores/uso terapéutico , Análisis de Varianza , Resinas Compuestas/química , Recubrimiento Dental Adhesivo/métodos , Ensayo de Materiales , Ilustración Médica , Distribución Aleatoria , Valores de Referencia , Reproducibilidad de los Resultados , Propiedades de Superficie/efectos de los fármacos , Factores de Tiempo , Resistencia a la Tracción/efectos de la radiación
19.
Braz. oral res. (Online) ; 29(1): 1-5, 2015. tab, ilus
Artículo en Inglés | LILACS | ID: lil-777244

RESUMEN

Increased surface roughness and wear of resin cements may cause failure of indirect restorations. The aim of this study was to evaluate quantitatively the surface roughness change and the vertical wear of four resin cements subjected to mechanical toothbrushing abrasion. Ten rectangular specimens (15 × 5 × 4 mm) were fabricated according to manufacturer instructions for each group (n = 10): Nexus 3, Kerr (NX3); RelyX ARC, 3M ESPE (ARC); RelyX U100, 3M ESPE (U100); and Variolink II, Ivoclar/Vivadent (VL2). Initial roughness (Ra, µm) was obtained through 5 readings with a roughness meter. Specimens were then subjected to toothbrushing abrasion (100,000 cycles), and further evaluation was conducted for final roughness. Vertical wear (µm) was quantified by 3 readings of the real profile between control and brushed surfaces. Data were subjected to analysis of variance, followed by Tukey’s test (p < 0.05). The Pearson correlation test was performed between the surface roughness change and wear (p < 0.05). The mean values of initial/final roughness (Ra, µm)/wear (µm) were as follows: NX3 (0.078/0.127/23.175); ARC (0.086/0.246/20.263); U100 (0.296/0.589/16.952); and VL2 (0.313/0.512/22.876). Toothbrushing abrasion increased surface roughness and wear of all resin cements tested, although no correlation was found between those variables. Vertical wear was similar among groups; however, it was considered high and may lead to gap formation in indirect restorations.


Asunto(s)
Alisadura de la Restauración Dental , Cementos de Resina/química , Abrasión de los Dientes , Cepillado Dental , Análisis de Varianza , Bisfenol A Glicidil Metacrilato/química , Ensayo de Materiales , Polietilenglicoles/química , Ácidos Polimetacrílicos/química , Valores de Referencia , Estadísticas no Paramétricas , Propiedades de Superficie , Factores de Tiempo
20.
Braz. dent. sci ; 18(1): 116-120, 2015. tab
Artículo en Inglés | LILACS | ID: lil-759966

RESUMEN

A irradiação com LASER de Neodímio (Nd:YAG) e de Diodo sobre sistemas adesivos pode aumentar a resistência de união em dentina, no entanto a existe a preocupação com a variação de temperatura intracâmara pulpar. O objetivo deste trabalho foi avaliar a variação da temperatura intracâmara pulpar após a aplicação dos sistemas adesivos e subsequente a irradiação com LASER de diodo e Nd:YAG. Material e Métodos: Este estudo apresentou um desenho experimental fatorial com dois fatores: LASER em dois níveis (Diodo [D] e Nd:YAG [N]) e sistema adesivo em quatro níveis (Adper™ Scotchbond™ Multi-Purpose [MP], Adper™ SingleBond 2 [SB], Clearfil™ SE Bond [CSE] e Adper™ Easy One [EO]). A variável de resposta quantitativa foi a variação da temperatura (∆t) em ºC .Utilizou-se 40 dentes bovinos, separados em 8 grupos (n=5), a superfície vestibular foi desgastada até 1 mm de espessura. Depois da aplicação de cada sistema adesivo, mas previamente a fotopolimerização, os espécimes eram irradiados com LASER de diodo e Nd:YAG com parâmetro padronizados. A ∆t foi obtida com um termopar inserido intracâmara pulpar. Os valores obtidos foram submetidos ao teste ANOVA a 2 critérios seguido de Tukey para comparações individuais(p<0,05). Resultados: A média e o desvio padrão da ∆t obtidos foram: N-MP: 12.60 (± 2.51), N-SB: 10.40 (± 5.03), N-CSE: 11.80 (± 5.12) e N-EO: 10.20 (± 2.39), D-MP: 4.4 (± 1.82), D-SB: 5.20 (± 1.54), D-CSE: 4.60 (± 1.14), D-EO: 3.60 (± 1.52). Conclusão: O tipo de sistema adesivo não foi significante no aquecimento gerado pela irradiação com LASER, mas o LASER de Nd:YAG pode fornecer um potencial maior para causar danos a pulpar...


Neodymium (Nd:YAG) and Diode LASER irradiation on adhesive systems canincrease bond strength to dentin, however, concerns about the temperature variation inside pulp chamber still remain. The aim of this study was to evaluate the intra pulp chamber temperature variation caused by irradiation with Nd:YAG or Diode LASER on different adhesive systems. Material and Methods: This study presented experimental design with two factors: LASER on two levels (Diode [D] and Nd:YAG [N]) and adhesive system on four levels (Adper™ Scotchbond™ Multi-Purpose [MP], Adper™ SingleBond 2 [SB], Clearfil™ SE Bond [CSE] and Adper™ Easy One [EO]). The quantitative response variable was the temperature variation (∆t) in ºC. Forty bovine teeth, distributed into 8 groups (n = 5), had the buccal surface flattened up to1 mm thickness of dentin. After the application of each adhesive system, but previously to the light curing, specimens were irradiated with Nd:YAG or Diode LASER with standardized parameters. The ∆t was obtained through a thermocouple inserted into pulp chamber. The values of ∆t were submitted to two-way ANOVA, followed by Tukey (p < 0.05) for individual comparisons. Results: The means (± standard deviation) of ∆t were: N-MP: 12.60 (± 2.51), N-SB: 10.40 (± 5.03), N-CSE: 11.80 (± 5.12) and N-EO: 10.20 (± 2.39), D-MP: 4.4 (± 1.82), D-SB: 5.20 (± 1.54), D-CSE: 4.60 (± 1.14), D-EO: 3.60 (± 1.52). Conclusion: The type of adhesive system was not significant in temperature changes generated by LASER irradiation, but Nd:YAG LASER may provide a higher potential to cause pulp damage...


Asunto(s)
Animales , Bovinos , Pulpa Dental , Recubrimientos Dentinarios , Rayos Láser
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA