Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
NMR Biomed ; 33(12): e4277, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32124505

RESUMEN

Multi-compartment T2 mapping has gained particular relevance for the study of myelin water in the brain. As a facilitator of rapid saltatory axonal signal transmission, myelin is a cornerstone indicator of white matter development and function. Regularized non-negative least squares fitting of multi-echo T2 data has been widely employed for the computation of the myelin water fraction (MWF), and the obtained MWF maps have been histopathologically validated. MWF measurements depend upon the quality of the data acquisition, B1+ homogeneity and a range of fitting parameters. In this special issue article, we discuss the relevance of these factors for the accurate computation of multi-compartment T2 and MWF maps. We generated multi-echo spin-echo T2 decay curves following the Carr-Purcell-Meiboom-Gill approach for various myelin concentrations and myelin T2 scenarios by simulating the evolution of the magnetization vector between echoes based on the Bloch equations. We demonstrated that noise and imperfect refocusing flip angles yield systematic underestimations in MWF and intra-/extracellular water geometric mean T2 (gmT2 ). MWF estimates were more stable than myelin water gmT2 time across different settings of the T2 analysis. We observed that the lower limit of the T2 distribution grid should be slightly shorter than TE1 . Both TE1 and the acquisition echo spacing also have to be sufficiently short to capture the rapidly decaying myelin water T2 signal. Among all parameters of interest, the estimated MWF and intra-/extracellular water gmT2 differed by approximately 0.13-4 percentage points and 3-4 ms, respectively, from the true values, with larger deviations observed in the presence of greater B1+ inhomogeneities and at lower signal-to-noise ratio. Tailoring acquisition strategies may allow us to better characterize the T2 distribution, including the myelin water, in vivo.


Asunto(s)
Simulación por Computador , Imagen por Resonancia Magnética , Vaina de Mielina/fisiología , Marcadores de Spin , Femenino , Humanos , Análisis de los Mínimos Cuadrados , Relación Señal-Ruido , Agua , Adulto Joven
2.
Behav Brain Res ; 297: 187-95, 2016 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-26467603

RESUMEN

In individuals with multiple sclerosis (MS), transcranial magnetic stimulation (TMS) may be employed to assess the integrity of corticospinal system and provides a potential surrogate biomarker of disability. The purpose of this study was to provide a comprehensive examination of the relationship between multiple measures corticospinal excitability and clinical disability in MS (expanded disability status scale (EDSS)). Bilateral corticospinal excitability was assessed using motor evoked potential (MEP) input-output (IO) curves, cortical silent period (CSP), short-interval intracortical inhibition (SICI), intracortical facilitation (ICF) and transcallosal inhibition (TCI) in 26 individuals with MS and 11 healthy controls. Measures of corticospinal excitability were compared between individuals with MS and controls. We evaluated the relationship(s) between age and clinical demographics such as age at MS onset (AO), disease duration (DD) and clinical disability (EDSS) with measures of corticospinal excitability. Corticospinal excitability thresholds were higher, MEP latency and CSP onset delayed and MEP durations prolonged in individuals with MS compared to controls. Age, DD and EDSS correlated with corticospinal excitability thresholds. Also, TCI duration and the linear slope of the MEP amplitude IO curve correlated with EDSS. Hierarchical regression modeling demonstrated that combining multiple TMS-based measures of corticospinal excitability accounted for unique variance in clinical disability (EDSS) beyond that of clinical demographics (AO, DD). Our results indicate that multiple TMS-based measures of corticospinal and interhemispheric excitability provide insights into the potential neural mechanisms associated with clinical disability in MS. These findings may aid in the clinical evaluation, disease monitoring and prediction of disability in MS.


Asunto(s)
Encéfalo/fisiopatología , Potenciales Evocados Motores , Esclerosis Múltiple/fisiopatología , Músculo Esquelético/fisiopatología , Tractos Piramidales/fisiopatología , Adulto , Edad de Inicio , Envejecimiento/fisiología , Evaluación de la Discapacidad , Electromiografía , Femenino , Lateralidad Funcional , Humanos , Modelos Lineales , Masculino , Persona de Mediana Edad , Análisis de Regresión , Factores de Tiempo , Estimulación Magnética Transcraneal
3.
J Magn Reson ; 259: 56-67, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26295169

RESUMEN

The fundamental basis of T1 and T2 contrast in brain MRI is not well understood; recent literature contains conflicting views on the nature of relaxation in white matter (WM). We investigated the effects of inversion pulse bandwidth on measurements of T1 and T2 in WM. Hybrid inversion-recovery/Carr-Purcell-Meiboom-Gill experiments with broad or narrow bandwidth inversion pulses were applied to bovine WM in vitro. Data were analysed with the commonly used 1D-non-negative least squares (NNLS) algorithm, a 2D-NNLS algorithm, and a four-pool model which was based upon microscopically distinguishable WM compartments (myelin non-aqueous protons, myelin water, non-myelin non-aqueous protons and intra/extracellular water) and incorporated magnetization exchange between adjacent compartments. 1D-NNLS showed that different T2 components had different T1 behaviours and yielded dissimilar results for the two inversion conditions. 2D-NNLS revealed significantly more complicated T1/T2 distributions for narrow bandwidth than for broad bandwidth inversion pulses. The four-pool model fits allow physical interpretation of the parameters, fit better than the NNLS techniques, and fits results from both inversion conditions using the same parameters. The results demonstrate that exchange cannot be neglected when analysing experimental inversion recovery data from WM, in part because it can introduce exponential components having negative amplitude coefficients that cannot be correctly modeled with nonnegative fitting techniques. While assignment of an individual T1 to one particular pool is not possible, the results suggest that under carefully controlled experimental conditions the amplitude of an apparent short T1 component might be used to quantify myelin water.


Asunto(s)
Espectroscopía de Resonancia Magnética/métodos , Sustancia Blanca/química , Algoritmos , Animales , Agua Corporal/química , Bovinos , Espacio Extracelular/química , Análisis de los Mínimos Cuadrados , Espectroscopía de Resonancia Magnética/estadística & datos numéricos , Modelos Estadísticos , Vaina de Mielina/química
4.
Neuroimage Clin ; 2: 569-80, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24179808

RESUMEN

Multi-component T2 relaxation imaging (MCRI) provides specific in vivo measurement of myelin water content and tissue water environments through myelin water fraction (MWF), intra/extra-cellular water fraction (I/EWF) and intra/extracellular and global geometric mean T2 (GMT2) times. Quantitative MCRI assessment of tissue water environments has provided new insights into the progression and underlying white matter pathology in neural disorders such as multiple sclerosis. It has not previously been applied to investigate changes in white matter in the stroke-affected brain. Thus, the purposes of this study were to 1) use MCRI to index myelin water content and tissue water environments in the brain after stroke 2) evaluate relationships between MWF and diffusion behavior indexed by diffusion tensor imaging-based metrics and 3) examine the relationship between white matter status (MWF and fractional anisotropy) and motor behavior in the chronic phase of stroke recovery. Twenty individuals with ischemic stroke and 12 matched healthy controls participated. Excellent to good test/re-test and inter-rater reliability was observed for region of interest-based voxelwise MWF data. Reduced MWF was observed in whole-cerebrum white matter (p < 0.001) and in the ipsilesional (p = 0.017) and contralesional (p = 0.037) posterior limb of internal capsule (PLIC) after stroke compared to whole-cerebrum and bilateral PLIC MWF in healthy controls. The stroke group also demonstrated increased I/EWF, I/E GMT2 and global GMT2 times for whole-cerebrum white matter. Measures of diffusion behavior were also significantly different in the stroke group across each region investigated (p < 0.001). MWF was not significantly correlated with specific tensor-based measures of diffusion in the PLIC for either group. Fractional anisotropy in the ipsilesional PLIC correlated with motor behavior in chronic stroke. These results provide novel insights into tissue-specific changes within white matter after stroke that may have important applications for the understanding of the neuropathology of stroke.

5.
Neurology ; 75(19): 1702-10, 2010 Nov 09.
Artículo en Inglés | MEDLINE | ID: mdl-21060093

RESUMEN

OBJECTIVES: To evaluate in vivo brain metabolite differences in control subjects, individuals with premanifest Huntington disease (pre-HD), and individuals with early HD using ¹H magnetic resonance spectroscopy (MRS) and to assess their relationship with motor performance. METHODS: Eighty-five participants (30 controls, 25 pre-HD, and 30 early HD) were recruited as part of the TRACK-HD study. Eighty-four were scanned at 3 T with single-voxel spectroscopy in the left putamen. Disease burden score was >220 among pre-HD individuals. Subjects underwent TRACK-HD motor assessment including Unified Huntington's Disease Rating Scale (UHDRS) motor scoring and a novel quantitative motor battery. Statistical analyses included linear regression and one-way analysis of variance. RESULTS: Total N-acetylaspartate (tNAA), a neuronal integrity marker, was lower in early HD (∼15%) vs controls (p < 0.001). N-acetylaspartate (NAA), a constituent of tNAA, was lower in pre-HD (∼8%) and early HD (∼17%) vs controls (p < 0.05). The glial cell marker, myo-inositol (mI), was 50% higher in early HD vs pre-HD (p < 0.01). In early HD, mI correlated with UHDRS motor score (R² = 0.23, p < 0.05). Across pre-HD and early HD, tNAA correlated with performance on a tongue pressure task (R² = 0.30, p < 0.0001) and with disease burden score (R² = 0.17, p < 0.005). CONCLUSIONS: We demonstrate lower putaminal tNAA in early HD compared to controls in a cross-section of subjects. A novel biomarker role for mI in early HD was also identified. These findings resolve disagreement in the literature about the role of MRS as an HD biomarker. We conclude that putaminal MRS measurements of NAA and mI are promising potential biomarkers of HD onset and progression.


Asunto(s)
Enfermedad de Huntington/diagnóstico , Enfermedad de Huntington/metabolismo , Espectroscopía de Resonancia Magnética/métodos , Adulto , Ácido Aspártico/análogos & derivados , Ácido Aspártico/metabolismo , Biomarcadores/metabolismo , Estudios de Cohortes , Diagnóstico Precoz , Femenino , Humanos , Enfermedad de Huntington/patología , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Putamen/metabolismo , Putamen/patología
6.
NMR Biomed ; 23(9): 1033-7, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-20963799

RESUMEN

The T(1) values of metabolites were measured in eight subjects with clinically definite multiple sclerosis (MS) having at least one large brain lesion (2.6 ± 0.7 mL) and in eight age- and sex-matched healthy controls. MRS examinations were conducted at 1.5 T using point-resolved spectroscopy (PRESS) (TE = 30 ms, TR = 530, 750, 1200, 1500, 3500, 5000 ms). Spectra were acquired from a voxel placed in the largest lesion in the subject with MS, and in a corresponding voxel (same size and region) in normal white matter (NWM) in the matched control, and were fitted using LCModel. As there are regional variations in metabolite and water T(1) and metabolite signal areas, careful placement of the control voxel was necessary to measure subtle differences between the lesions and NWM. The T(1) and T(1)-corrected signal areas of creatine were the same in MS lesions as in controls. The T(1) values of choline were significantly shorter in MS lesions located in occipital and parietal, but not in frontal, white matter. N-Acetylaspartate (NAA) and myoinositol T(1) values in MS lesions were similar to those in NWM; however, the area of myoinositol correlated directly with lesion water T(1), and the area of NAA correlated inversely with lesion water T(1). MR spectra acquired at short TR require T(1) correction of choline for accurate quantification. Careful voxel placement in controls to match lesion location in subjects with MS enables a clearer view of the subtle changes in lesions.


Asunto(s)
Espectroscopía de Resonancia Magnética/métodos , Esclerosis Múltiple/metabolismo , Esclerosis Múltiple/patología , Protones , Ácido Aspártico/análogos & derivados , Ácido Aspártico/metabolismo , Colina/metabolismo , Humanos , Inositol/metabolismo , Agua
7.
Mult Scler ; 16(6): 670-7, 2010 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-20558500

RESUMEN

BACKGROUND: Spinal cord involvement in multiple sclerosis (MS) is common and an important element in disability. Previous studies demonstrated smaller cervical cord area at the C2 level in MS compared to controls, and a decrease in cord area over 12 months, most marked in primary progressive MS (PPMS). A subset of subjects participating in a multicentre, double-blind, placebo-controlled clinical trial evaluating the efficacy of glatiramer acetate in PPMS (PROMiSe trial) were followed for 2 years. METHODS: 24 PPMS subjects, randomized to placebo (n = 9) and glatiramer acetate (n = 15), and 24 matched controls were studied. Cervical cord volume (CCV) at C2-3 was determined using a 3D inversion recovery (IR)-prepared spoiled-gradient echo sequence. Myelin water fraction (MWF) at C2-3 was obtained using a 32-echo IR-prepared relaxation sequence. Scans were repeated at baseline, years 1 and 2. RESULTS: Baseline CCV was significantly smaller for PPMS than controls [median (interquartile range) 951 (829-1043) vs. 1072 (1040-1129) mm(3), p = 0.0004] and MWF trended to be lower in PPMS cord [median (interquartile range) 0.225 (0.187-0.267) vs. 0.253 (0.235-0.266), p = 0.12]. Baseline CCV correlated with baseline Expanded Disability Status Scale, disease duration, brain white and grey matter volume. In PPMS, CCV was significantly decreased at year 1 (-0.83%, p = 0.04) and year 2 (-1.65%, p = 0.02). Baseline MWF correlated with baseline CCV and brain white and grey matter volume. MWF was significantly decreased from baseline for PPMS at year 2 (-10.5%, p = 0.01). Treatment effect was not detected on change in CCV nor MWF. CONCLUSIONS: Metrics at the level of the cord, including volume and MWF at C2-3, were lower in PPMS than controls and changed over 2 years only in PPMS.


Asunto(s)
Agua Corporal , Esclerosis Múltiple Crónica Progresiva/patología , Vaina de Mielina/química , Médula Espinal/patología , Adulto , Anciano , Atrofia/patología , Encéfalo/patología , Vértebras Cervicales , Progresión de la Enfermedad , Método Doble Ciego , Femenino , Acetato de Glatiramer , Humanos , Inmunosupresores/uso terapéutico , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Esclerosis Múltiple Crónica Progresiva/tratamiento farmacológico , Vaina de Mielina/efectos de los fármacos , Tamaño de los Órganos/efectos de los fármacos , Péptidos/uso terapéutico , Reproducibilidad de los Resultados , Médula Espinal/efectos de los fármacos , Resultado del Tratamiento
8.
NMR Biomed ; 22(3): 349-54, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19107764

RESUMEN

Magnetic resonance spectroscopy (MRS) has been coupled with a multi-echo imaging sequence to determine the relaxation corrected signal areas of the metabolites and the tissue water. Stimulated echo acquisition mode (STEAM) spectra (TE/TM/TR 30/13.7/5000 ms) acquired from gray and white matter voxels in 43 healthy volunteers were fit using LCModel. Corresponding water signals, measured using a multi-echo T(2) imaging sequence, were fit with a Non-Negative Least Squares algorithm. Using this approach the water area could be T(1) and T(2) corrected for all three water compartments: cerebrospinal fluid (CSF), intra- and extra-cellular water, and myelin water. The image-based water measurement is an improvement over spectroscopy methods because it can be more sensitive to water changes in diseased tissue. Metabolite areas were also corrected for relaxation losses. In occipital gray matter, the concentrations of Cho, Cr, and N-acetyl aspartate (NAA) were 1.27 (0.06), 8.9 (0.3), and 9.3 (0.3) mmol/L tissue, respectively and in parietal white matter they were 1.90 (0.05), 7.9 (0.2), and 9.8 (0.2) mmol/L tissue. The Cho and Cr concentrations were different in occipital gray compared to parietal white matter (p < 0.0001 and <0.005, respectively).


Asunto(s)
Encéfalo/metabolismo , Metaboloma , Agua/metabolismo , Adulto , Calibración , Humanos , Espectroscopía de Resonancia Magnética
9.
J Neurol Sci ; 276(1-2): 49-53, 2009 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-18822435

RESUMEN

Multiple sclerosis (MS) is characterised by focal areas that undergo cycles of demyelination and remyelination. Although conventional magnetic resonance imaging is very effective in localising areas of damage, these techniques are not pathology specific. A newer technique, T(2) relaxation, can separate water from brain into three compartments: (1) a long T(2) component (>2 s) arising from CSF, (2) an intermediate T(2) component (~80 ms) attributed to intra- and extra-cellular water and (3) a short T(2) component (~20 ms) assigned to water trapped in between the myelin bilayers (termed myelin water). Histological evidence shows that myelin water is a specific marker of myelination. The goal of this work was to follow changes in total water content (WC) and myelin water fraction (MWF) in evolving MS lesions over one year. Multi-echo T(2) relaxation data was collected and used to measure water content and myelin water fraction from three new MS lesions in two patients. WC increased in the three large (>1 cm(3)) lesions at lesion appearance and remained elevated in the central core. Two lesions showed low MWF in the core suggesting demyelination upon first appearance. At later time points, one lesion showed a decrease in volume of low MWF, reflecting remyelination whereas the volume of low MWF in the other lesion core remained constant. This work provides evidence that MWF and WC can monitor demyelination and remyelination in MS.


Asunto(s)
Esclerosis Múltiple/metabolismo , Esclerosis Múltiple/patología , Vaina de Mielina/química , Agua/metabolismo , Adulto , Imagen Eco-Planar/métodos , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Estudios Longitudinales , Persona de Mediana Edad
10.
Neuroimaging Clin N Am ; 19(1): 1-26, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19064196

RESUMEN

This article provides an overview of relaxation times and their application to normal brain and brain and cord affected by multiple sclerosis. The goal is to provide readers with an intuitive understanding of what influences relaxation times, how relaxation times can be accurately measured, and how they provide specific information about the pathology of MS. The article summarizes significant results from relaxation time studies in the normal human brain and cord and from people who have multiple sclerosis. It also reports on studies that have compared relaxation time results with results from other MR techniques.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Esclerosis Múltiple/patología , Encéfalo/patología , Mapeo Encefálico/métodos , Humanos , Médula Espinal/patología , Tiempo
11.
J Neurol ; 254(12): 1653-9, 2007 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-17934875

RESUMEN

BACKGROUND: Chronic T(1) hypointense lesions in multiple sclerosis (MS) are areas of severe tissue destruction. The purpose of this study was to compare total water content (WC),myelin water content (MWC), magnetization transfer ratio (MTR), T(1) relaxation time (T(1)), mean T(2) relaxation time (GMT(2)) between stable MS lesions that are hypointense and isointense on T(1)-weighted images. METHODS: Six MS patients were scanned five times over one year. WC, MWC, MTR, T(1) and GMT(2) were calculated for 15 isointense and 15 hypointense chronically stable T(1) lesions, as well as contralateral normal appearing white matter (NAWM). RESULTS: All MR measurements from both iso- and hypointense stable lesion types were significantly different from NAWM. WC, T(1) and GMT(2) were significantly higher and MTR significantly lower in hypointense T(1) lesions compared to isointense lesions. MWC was not significantly different between iso- and hypointense lesions. CONCLUSIONS: This work suggests that myelin loss occurs equally in both the chronic isointense and hypointense lesions but hypointense lesions are distinguished by increased extracellular water.


Asunto(s)
Encéfalo/patología , Imagen por Resonancia Magnética/métodos , Esclerosis Múltiple/metabolismo , Esclerosis Múltiple/patología , Vaina de Mielina/metabolismo , Adulto , Mapeo Encefálico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad , Agua/metabolismo
12.
Mult Scler ; 12(6): 747-53, 2006 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-17263002

RESUMEN

Various magnetic resonance (MR) techniques are used to study the pathological evolution of demyelinating diseases, such as multiple sclerosis (MS). However, few studies have validated MR derived measurements with histopathology. Here, we determine the correlation of myelin water imaging, an MR measure of myelin content, with quantitative histopathologic measures of myelin density. The multi-component T2 distribution of water was determined from 25 formalin-fixed MS brain samples using a multi-echo T2 relaxation MR experiment. The myelin water fraction (MWF), defined as T2 signal below 30 milliseconds divided by the total signal, was determined for various regions of interest and compared to Luxol fast blue (myelin stain) mean optical density (OD) for each sample. MWF had a strong correlation with myelin stain [mean (range) R2 = 0.67 (0.45-0.92)], validating MWF as a measure of myelin density. This quantitative technique has many practical applications for the in vivo monitoring of demyelination and remyelination in a variety of disorders of myelin.


Asunto(s)
Imagen Eco-Planar/normas , Esclerosis Múltiple Crónica Progresiva/patología , Vaina de Mielina/patología , Agua/metabolismo , Adulto , Anciano , Anciano de 80 o más Años , Biomarcadores , Enfermedades Desmielinizantes/metabolismo , Enfermedades Desmielinizantes/patología , Femenino , Fijadores , Formaldehído , Humanos , Masculino , Persona de Mediana Edad , Esclerosis Múltiple Crónica Progresiva/metabolismo , Vaina de Mielina/metabolismo , Conservación de Tejido
13.
Magn Reson Med ; 54(5): 1072-81, 2005 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-16200557

RESUMEN

In vitro experiments on 15 white matter samples from five bovine brains were performed on a 1H-NMR spectrometer at 24 degrees C and 37 degrees C. The average myelin water fractions (MWFs) were 10.9% and 11.8% for samples at 24 degrees C and 37 degrees C, respectively. The T1 relaxation time at 37 degrees C was found to be 830 ms, exhibiting monoexponential behavior. A four-pool model including intra/extracellular (IE) water, myelin water, nonmyelin tissue, and myelin tissue was proposed to simulate the NMR behavior of bovine white matter. A cross-relaxation correction was introduced to compensate for shifting of the measured data points and T2 times over the duration of the Carr-Purcell-Meiboom-Gill (CPMG) measurement due to cross relaxation. This correction was found to be slight, providing evidence that MWFs measured using a multiecho technique are near physical values. At 24 degrees C the cross-relaxation times between myelin tissue and myelin water, myelin water and IE water, and IE water and nonmyelin tissue were found to be approximately 227, 2064, and 402 ms, respectively. At 37 degrees C these same cross-relaxation times were 158, 1021, and 170 ms, respectively. The exchange rate between myelin water and myelin was found to be 11.8 s-1 at 37 degrees C, while the exchange rate between IE water and nonmyelin tissue was found to be 6.8 s-1. These exchange rates are of similar magnitude, which indicates that the interaction between IE water and nonmyelin tissue cannot be ignored.


Asunto(s)
Algoritmos , Agua Corporal/metabolismo , Encéfalo/metabolismo , Espectroscopía de Resonancia Magnética/métodos , Modelos Neurológicos , Vaina de Mielina/metabolismo , Fibras Nerviosas Mielínicas/metabolismo , Animales , Bovinos , Simulación por Computador , Técnicas In Vitro , Protones , Temperatura
14.
NMR Biomed ; 18(1): 14-8, 2005 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-15455460

RESUMEN

T2 of NAA, creatine and choline-containing compounds were measured in posterior frontal white matter and occipital grey matter in 10 healthy human volunteers. Decay curves comprised signals from eight TE times ranging from 30 to 800 ms with TR 2000 ms acquired with a PRESS sequence on a 1.5 T clinical scanner. Simulations were conducted to assess the precision of T2 estimates from decay curves comprising varying numbers and ranges of TE points. Mean and standard errors for T2s of NAA, creatine and choline-containing compounds were 300(8), 169(3) and 239(4) ms in posterior frontal white matter and 256(6), 159(8) and 249(8) ms in occipital grey matter. In vivo T2s found for choline and NAA were shorter than the T2s in the literature. The elevation of literature T2s is accounted for by the simulation results, which demonstrated that there is a bias towards lengthened T2s when T2 is measured with a maximum TE approximately T2. Concentration estimates are at risk of being underestimated if previously reported T2 corrections are used.


Asunto(s)
Algoritmos , Astrocitos/metabolismo , Colina/metabolismo , Creatina/metabolismo , Lóbulo Frontal/metabolismo , Espectroscopía de Resonancia Magnética/métodos , Neuronas/metabolismo , Lóbulo Occipital/metabolismo , Adulto , Femenino , Humanos , Masculino , Protones , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
15.
J Neurol ; 251(3): 284-93, 2004 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15015007

RESUMEN

BACKGROUND: Measurements of the T2 decay curve provide estimates of total water content and myelin water fraction in white matter in-vivo, which may help in understanding the pathological progression of multiple sclerosis (MS). METHODS: Thirty-three MS patients (24 relapsing remitting, 8 secondary progressive, 1 primary progressive) and 18 controls underwent MR examinations. T2 relaxation data were acquired using a 32-echo measurement. All controls and 18 of the 33 MS patients were scanned in the transverse plane through the genu and splenium of the corpus callosum. Five white matter and 6 grey matter structures were outlined in each of these subjects. The remaining 15 MS patients were scanned in other transverse planes. A total of 189 lesions were outlined in the MS patients. Water content and myelin water fraction were calculated for all regions of interest and all lesions. RESULTS: The normal appearing white matter (NAWM) water content was, on average, 2.2% greater than that from controls, with significant differences occurring in the posterior internal capsules, genu and splenium of the corpus callosum, minor forceps and major forceps (p<0.0006). On average, MS lesions had 6.3% higher water content than contralateral NAWM (p<0.0001). Myelin water fraction was 16% lower in NAWM than for controls, with significant differences in the major and minor forceps, internal capsules, and splenium (p<0.05). The myelin water fraction of MS lesions averaged 52 % that of NAWM. CONCLUSIONS: NAWM in MS has a higher water content and lower myelin water fraction than control white matter. The cause of the myelin water fraction decrease in NAWM could potentially be due to either diffuse edema, inflammation, demyelination or any combination of these features. We present a simple model which suggests that myelin loss is the dominant feature of NAWM pathology.


Asunto(s)
Imagen Eco-Planar/métodos , Esclerosis Múltiple/patología , Vaina de Mielina/química , Agua/análisis , Adulto , Encéfalo/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Modelos Neurológicos
16.
Mol Psychiatry ; 8(9): 811-20, 2003 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-12931208

RESUMEN

Schizophrenia unfolds during the late period of brain maturation, while myelination is still continuing. In the present study, we used MRI and T2 relaxation analysis to measure the myelin water fraction in schizophrenia. In schizophrenia (n=30) compared with healthy subjects (n=27), overall white matter showed 12% lower myelin water fraction (P=0.031), with the most prominent effects on the left genu of the corpus callosum (36% lower, P=0.002). The left anterior genu was affected in both first-episode (P=0.035) and chronic patients (P=0.011). In healthy subjects, myelin water fraction in total white matter and in frontal white matter increased with age, and with years of education, indicating ongoing maturation. In patients with schizophrenia, neither relation was statistically significant. Post-mortem studies of anterior frontal cortex demonstrated less immunoreactivity of two oligodendrocyte-associated proteins in schizophrenia (2',3'-cyclic nucleotide 3'-phosphodiesterase by 33%, P=0.05; myelin-associated glycoprotein by 27%, P=0.14). Impaired myelination in schizophrenia could contribute to abnormalities of neural connectivity and persistent functional impairment in the illness.


Asunto(s)
Enfermedades Desmielinizantes/diagnóstico , Fibras Nerviosas Mielínicas/patología , Esquizofrenia/patología , 2',3'-Nucleótido Cíclico Fosfodiesterasas/análisis , Adulto , Composición Corporal/fisiología , Compartimentos de Líquidos Corporales/fisiología , Enfermedad Crónica , Enfermedades Desmielinizantes/complicaciones , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Análisis por Apareamiento , Persona de Mediana Edad , Vaina de Mielina/química , Glicoproteína Asociada a Mielina/análisis , Oligodendroglía/química , Oligodendroglía/patología , Valores de Referencia , Esquizofrenia/complicaciones , Agua/análisis
17.
Nature ; 410(6824): 19, 2001 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-11242019
18.
Magn Reson Med ; 44(6): 860-6, 2000 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-11108622

RESUMEN

Magnetization transfer ratios (MTRs) were measured separately for the two T(2) components in white matter. For both binomial and off-resonance sinc MT pulses, the MTR was larger for the short T(2) component than for the long T(2) component. This differential MT effect disappeared for delays between the MT pulse and the multi-echo pulse sequence longer than 200 msec, indicating exchange between the two components. When using the sinc MT pulse, the MTR for the short T(2) component was similar for different white matter structures, whereas it varied for different white matter structures when using the binomial pulse-a phenomenon attributed to direct saturation. When the sinc pulse frequency was brought closer to resonance, MTRs in white matter and doped water phantoms increased for both components but more so for the shorter T(2) component. This behavior was consistent with a Bloch equation model of direct saturation.


Asunto(s)
Encéfalo/anatomía & histología , Imagen por Resonancia Magnética , Adolescente , Adulto , Humanos , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/estadística & datos numéricos , Persona de Mediana Edad , Valores de Referencia , Reproducibilidad de los Resultados , Factores de Tiempo
19.
Neurology ; 55(10): 1506-10, 2000 Nov 28.
Artículo en Inglés | MEDLINE | ID: mdl-11094105

RESUMEN

OBJECTIVE: To determine the pathologic basis of areas not exhibiting signal of the short-T2 component of the T2 relaxation distribution in MS, as studied in formalin-fixed brain. BACKGROUND: A myelin-specific MRI signal would be of great importance in assessing demyelination in patients with MS. Evidence indicates that the short-T2 (10 to 50 millisecond) component of the T2 relaxation distribution originates from water in myelin sheaths. The authors present two cases of MS in which the anatomic distribution of the short-T2 component was correlated with the pathologic findings in postmortem formalin-fixed brain. METHOD: One half of the formalin-fixed brain was suspended in a gelatin-albumin mixture cross-linked with glutaraldehyde, and scanned with a 32-echo MRI sequence. The brain was then cut along the center of the 5-mm slices scanned, photographed, dehydrated, and embedded in paraffin. Paraffin sections, stained with Luxol fast blue and immunocytochemically for 2',3'-cyclic nucleotide 3'-phosphohydrolase for myelin and by the Bielschowsky technique for axons, were compared with the distribution of the amplitude of the short-T2 component of the comparable image slices. RESULTS: The anatomic distribution of the short-T2 component signal corresponded to the myelin distribution. Chronic, silent MS plaques with myelin loss correlated with areas of absence of short-T2 signal. The numbers of axons within lesions were reduced, but many surviving axons were also seen in these areas of complete loss of myelin. CONCLUSION: In formalin-fixed MS brains the short-T2 component of the T2 relaxation distribution corresponds to the anatomic distribution of myelin. Chronic, silent demyelinated MS plaques show absence of the short-T2 component signal. These results support the hypothesis that the short-T2 component originates from water related to myelin.-1510


Asunto(s)
Encéfalo/patología , Esclerosis Múltiple/patología , Anciano , Femenino , Humanos , Imagen por Resonancia Magnética , Persona de Mediana Edad
20.
Radiographics ; 20(3): 699-712, 2000.
Artículo en Inglés | MEDLINE | ID: mdl-10835123

RESUMEN

Artifact arising from metal hardware remains a significant problem in orthopedic magnetic resonance imaging. The metal artifact reduction sequence (MARS) reduces the size and intensity of susceptibility artifacts from magnetic field distortion. The sequence, which is based on view angle tilting in combination with increased gradient strength, can be conveniently used in conjunction with any spin-echo sequence and requires no additional imaging time. In patients with persistent pain after femoral neck fracture, the MARS technique allows visualization of marrow adjacent to hip screws, thus enabling diagnosis or exclusion of avascular necrosis. Other applications in the hip include assessment of periprosthetic soft tissues after hip joint replacement surgery, postoperative assessment after resection of bone tumors and reconstruction, and localization of unopacified methyl methacrylate cement prior to hip arthroplasty revision surgery. In the knee, the MARS technique allows visualization of structures adjacent to implanted metal staples, pins, or screws. The technique can significantly improve visualization of periprosthetic bone and soft-tissue structures even in patients who have undergone total knee arthroplasty. In patients with spinal fixation hardware, the MARS technique frequently allows visualization of the vertebral bodies and spinal canal contents. The technique can be helpful after wrist fusion or screw fixation of scaphoid fractures.


Asunto(s)
Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Metales , Adulto , Anciano , Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Artefactos , Tornillos Óseos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Complicaciones Posoperatorias/diagnóstico , Engrapadoras Quirúrgicas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...