1.
Electrophoresis ; 35(18): 2608-14, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24913917

RESUMEN

Current methods for determination of impurities with different charge-to-volume ratio are limited especially in terms of sensitivity and precision. The main goal of this research was to establish a quantitative method for determination of impurities with charges differing from that of recombinant human granulocyte colony-stimulating factor (rhG-CSF, filgrastim) with superior precision and sensitivity compared to existing methods. A CZE method has been developed, optimized, and validated for a purity assessment of filgrastim in liquid pharmaceutical formulations. Optimal separation of filgrastim from the related impurities with different charges was achieved on a 50 µm id fused-silica capillary of a total length of 80.5 cm. A BGE that contains 100 mM phosphoric acid adjusted to pH 7.0 with triethanolamine was used. The applied voltage was 20 kV while the temperature was maintained at 25°C. UV detection was set to 200 nm. Method was validated in terms of selectivity/specificity, linearity, precision, LOD, LOQ, stability, and robustness. Linearity was observed in the concentration range of 6-600 µg/mL and the LOQ was determined to be 0.3% relative to the concentration of filgrastim of 0.6 mg/mL. Other validation parameters were also found to be acceptable; thus the method was successfully applied for a quantitative purity assessment of filgrastim in a finished drug product.


Asunto(s)
Electroforesis Capilar/métodos , Factor Estimulante de Colonias de Granulocitos/química , Formas de Dosificación , Contaminación de Medicamentos , Estabilidad de Medicamentos , Filgrastim , Modelos Lineales , Proteínas Recombinantes/química , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
2.
J Chromatogr A ; 1062(1): 79-86, 2005 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-15679145

RESUMEN

Instead of usual rationale for chromatographic fingerprint based sample identification which relies upon visual inspection or principal component analysis of raw or aligned chromatograms novel nonparametric statistical measure of fingerprint set homogeneity is proposed. Randomization test is applied for significance analysis of fingerprint set homogeneity while average maximum crosscorrelation is used as a merit function. Chromatogram sets generated by random selection from standard and unknown sample chromatogram collections are compared with respect to merit function values with set of chromatograms that represents standard and/or unknown sample. In that instance fingerprint homogeneity significance is represented by the fraction of random chromatogram sets that have higher merit values than the standard and/or unknown sample sets. A set of peptide maps corresponding to different haemoglobin variants has been selected for evaluation of proposed test. This approach is compared to chromatogram alignment based on correlation optimized warping coupled with principal component or cluster analysis. Proposed method is simple i.e. straightforward sample identification procedure which reliability has been evaluated here. Impact of this approach on peptide mapping validation and system suitability analysis is discussed.


Asunto(s)
Cromatografía Liquida/métodos