Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Adv Exp Med Biol ; 1457: 33-44, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39283419

RESUMEN

The whole world has lived in fear of the Coronavirus 2019 (COVID-19) for more than one-fourth of a year in 2020. Since then, numerous studies have been done and others are still being conducted to identify the coronavirus causal agent and determine the ideal antiviral therapies for treating this illness. Despite the fact of significant global efforts, which are being made to develop vaccines and identify therapeutic medicines, the emergence of multiple variants has rumbled the research for developing an ideal diagnostic and therapeutic tool for targeting COVID-19. A thorough anatomy of the coronavirus virus and its global dissemination is essential for healthcare initiatives, as well as for predicting and preventing new epidemics. Testing for active COVID-19 infections is a critical public health strategy for tracking the epidemic. The widespread adoption of polymerase chain reaction (PCR) and antigen rapid test assays has increased the supply of test kits. In this chapter, the significance of molecular technique to develop prognostic analytical techniques for targeting COVID-19 along with the advantages and limitations of available techniques is discussed.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/virología , COVID-19/prevención & control , SARS-CoV-2/genética , SARS-CoV-2/efectos de los fármacos , SARS-CoV-2/fisiología
2.
Heliyon ; 10(12): e33270, 2024 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-39021982

RESUMEN

This research paper reports an enhancement of thermal, optical, mechanical and antibacterial activities of the Polyvinyl alcohol-Nanodiamonds (PVA-NDs) composite required for the food packaging industry. The synthesis of composites was done by the wet processing method. The large surface area of NDs facilitated the robust interaction between the hydroxyl group and macromolecular chains of PVA to enhance the hydrogen bonding of PVA with NDs rather than PVA molecules. Thus, a reduction in PVA diffraction peak intensity was reported. NDs improved the thermal stability by preventing the out-diffusion of volatile decomposition products of PVA. The results also revealed an enhancement in tensile strength (∼60 MPa) and ductility (∼180 %). PVA-NDs composite efficiently blocked the UVC (100 %), most of the part of the UVB (∼85 % above 300 nm), and UVA (∼58 %). Furthermore, enhanced antibacterial activities were reported for PVA-NDs composite against E. coli and S. aureus. NDs accumulated around the bacterial cells prevented essential cellular functions and led to death. Hence, this composite could be a promising candidate for safe, thermally stable, strong, flexible, transparent, UV- resistant antibacterial food packaging material.

3.
Heliyon ; 10(9): e30500, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38765069

RESUMEN

Bacterial antimicrobial resistance (BAMR) seems to pose the greatest threat to public health, food safety, and agriculture in this century. The development of novel efficient antimicrobial agents to combat bacterial infections has become a global issue. Silver nanoparticles (Ag NPs) appeared as a feasible alternative to antibiotics. However, Ag NPs face cost, toxicity, and aggregation issues which limit their antibacterial activity. This work aims to stabilize Ag NPs with enhanced antimicrobial activity at comparatively lower Ag concentrations to prevent bacterial infections. For this purpose, the Ag core was covered with nanodiamonds (NDs). Ag-NDs composite have been synthesized by microplasma technique. TEM analysis confirmed the presence of both Ag and NDs in the Ag-NDs composite. A particle size (∼19 nm) was reported for Ag-NDs at the highest concentration as compared to Ag NPs (∼3 nm). The conduction band of the diamond acted as an extremely strong reducing agent for Ag NPs. The large surface area of NDs stabilized the Ag NPs. A redshift (∼400 nm-406 nm) in UV-visible spectra of the Ag-NDs composite indicated the formation of bigger-sized Ag NPs after incorporating NDs. XRD and LIBS analysis verified the increase in intensity of Ag-NPs by increasing ND concentration. The presence of functional groups including OH, CH, and Ag/Ag2O was confirmed by FTIR. Bacterial inhibition growth appeared to be a dose-dependent process. The minimum inhibition concentration value of Ag-NDs composite at the highest NDs concentration against E. coli (∼ 0.69 µg/ml) and S. aureus (∼44 µg/ml). This is the first study to report the smallest MIC for E. coli (<1 µg/ml). Ag-ND composites emerged to be more efficient than Ag NPs and preferred to be used against BAMR. The enhanced antibacterial activity of the Ag-NDs composite makes it a potential candidate for antibiotics, food products, and pesticides.

4.
3 Biotech ; 13(7): 223, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37292139

RESUMEN

Upon understanding the boosting role of carotenoids on the endogenous anti-inflammatory system, it is vital to explore their role in reducing the use of high doses of non-steroidal anti-inflammatory drug (NSAIDs), and their mediated secondary toxicity during the treatment of chronic diseases. The current study investigates the carotenoids potential on inhibition of secondary complications induced by NSAIDs, aspirin (ASA) against lipopolysaccharide (LPS) stimulated inflammation. Initially, this study evaluated a minimal cytotoxic dose of ASA and carotenoids (ß-carotene, BC/lutein, LUT/astaxanthin, AST/fucoxanthin FUCO) in Raw 264.7, U937, and peripheral blood mononuclear cells (PBMCs). In all three cells, carotenoids + ASA treatment reduced the LDH release, NO, and PGE2 efficiently than an equivalent dose of carotenoid or ASA treated alone. Based on cytotoxicity and sensitivity results, RAW 264.7 cells were selected for further cell-based assay. Among carotenoids, FUCO + ASA exhibited an efficient reduction of LDH release, NO, and PGE2 than the other carotenoids (BC + ASA, LUT + ASA, and AST + ASA) treatment. FUCO + ASA combination decreased LPS/ASA induced oxidative stress, pro-inflammatory mediators (iNOS, COX-2, and NF-κB), and cytokines (IL-6, TNF-α, and IL-1ß) efficiently. Further, apoptosis was inhibited by 69.2% in FUCO + ASA, and 46.7% in ASA than LPS treated cells. A drastic decrease in intracellular ROS generation with the increase in GSH was observed in FUCO + ASA compared to LPS/ASA groups. The results documented on the low dose of ASA with a relative physiological concentration of FUCO suggested greater importance for alleviating secondary complications and optimize prolonged chronic disease treatments with NSAID's associated side effects. Supplementary Information: The online version contains supplementary material available at 10.1007/s13205-023-03632-w.

5.
Biotechnol Genet Eng Rev ; 39(1): 85-117, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35861776

RESUMEN

Oral microbial ecosystems are vital in maintaining the health of the oral cavity and the entire body. Oral microbiota is associated with the progression of oral diseases such as dental caries, periodontal diseases, head and neck cancer, and several systemic diseases such as cardiovascular disease, rheumatoid arthritis, adverse pregnancy outcomes, diabetes, lung infection, colorectal cancer, and pancreatic cancer. Buccal mucosa, tongue dorsum, hard palate, saliva, palatine tonsils, throat, keratinized gingiva, supra-gingival plaque, subgingival plaque, dentures, and lips are microbial habitats of the oral cavity. Porphyromonas gingivalis may have a role in the development of periodontal diseases, oral cancer, diabetes, and atherosclerotic disease. Fusobacterium nucleatum showed a higher abundance in periodontal diseases, oral and colon cancer, adverse pregnancy outcomes, diabetes, and rheumatoid arthritis. The higher abundance of Prevotella intermedia is typical in periodontal diseases, rheumatoid arthritis, and adverse pregnancy outcome. S. salivarius displayed higher abundance in both dental caries and OSCC. Oral bacteria may influence systemic diseases through inflammation by releasing pro inflammatory cytokines. Identification of oral bacteria using culture-dependent approaches and next-generation sequencing-based metagenomic approaches is believed to significantly identify the therapeutic targets and non-invasive diagnostic indicators in different human diseases. Oral bacteria in saliva could be exploited as a non-invasive diagnostic indicator for the early detection of oral and systemic disorders. Other therapeutic approaches such as the use of probiotics, green tea polyphenol, cold atmospheric plasma (CAP) therapy, antimicrobial photodynamic therapy, and antimicrobial peptides are used to inhibit the growth of biofilm formation by oral bacteria.


Porphyromonas gingivalis may have a role in the development of periodontal diseases, oral cancer, diabetes, and atherosclerotic diseaseFusobacterium nucleatum showed a higher abundance in periodontal diseases, oral and colon cancer, adverse pregnancy outcomes, diabetes, and rheumatoid arthritisOral bacteria may influence systemic diseases through inflammation by releasing pro inflammatory cytokines.Identification of oral bacteria in saliva may be used as a non-invasive diagnostic indicator for the early detection of oral and systemic disorders.


Asunto(s)
Artritis Reumatoide , Caries Dental , Microbiota , Enfermedades Periodontales , Femenino , Humanos , Embarazo , Enfermedades Periodontales/microbiología , Porphyromonas gingivalis
6.
Front Digit Health ; 3: 723204, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34778867

RESUMEN

The study of carbon dioxide expiration is called capnometry. The graphical representation of capnometry is called capnography. There is a growing interest in the usage of capnography as the usage has expanded toward the study of metabolism, circulation, lung perfusion and diffusion, quality of spontaneous respiration, and patency of airways outside of its typical usage in the anesthetic and emergency medicine field. The parameters of the capnograph could be classified as carbon dioxide (CO2) concentration and time points and coordinates, slopes angle, volumetric studies, and functional transformation of wave data. Up to date, there is no gold standard device for the calculation of the capnographic parameters. Capnography digitization using the image processing technique could serve as an option. From the algorithm we developed, eight identical breath waves were tested by four investigators. The values of the parameters chosen showed no significant difference between investigators. Although there were no significant differences between any of the parameters tested, there were a few related parameters that were not calculable. Further testing after refinement of the algorithm could be done. As more capnographic parameters are being derived and rediscovered by clinicians and researchers alike for both lung and non-lung-related diseases, there is a dire need for data analysis and interpretation. Although the proposed algorithm still needs minor refinements and further large-scale testing, we proposed that the digitization of the capnograph via image processing technique could serve as an intellectual option as it is fast, convenient, easy to use, and efficient.

7.
Life (Basel) ; 11(10)2021 Oct 17.
Artículo en Inglés | MEDLINE | ID: mdl-34685472

RESUMEN

In November 2019, the novel coronavirus disease COVID-19 was reported in Wuhan city, China, and was reported in other countries around the globe. COVID-19 is caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. Strategies such as contact tracing and a vaccination program have been imposed to keep COVID-19 under control. Furthermore, a fast, noninvasive and reliable testing device is needed urgently to detect COVID-19, so that contact can be isolated and ringfenced before the virus spreads. Although the reverse transcription polymerase chain reaction (RT-PCR) test is considered the gold standard method for the diagnosis of SARS-CoV-2 infection, this test presents some limitations which cause delays in detecting the disease. The antigen rapid test (ART) test, on the other hand, is faster and cheaper than PCR, but is less sensitive, and may limit SARS-CoV-2 detection. While other tests are being developed, accurate, noninvasive and easy-to-use testing tools are in high demand for the rapid and extensive diagnosis of the disease. Therefore, this paper reviews current diagnostic methods for COVID-19. Following this, we propose the use of expired carbon dioxide (CO2) as an early screening tool for SARS-CoV-2 infection. This system has already been developed and has been tested on asthmatic patients. It has been proven that expired CO2, also known as capnogram, can help differentiate between respiratory conditions and, therefore, could be used to detect SARS-CoV-2 infection, as it causes respiratory tract-related diseases.

8.
Clin Nutr ESPEN ; 42: 124-131, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33745565

RESUMEN

BACKGROUND & AIMS: Previous studies have shown that end-tidal carbon dioxide (EtCO2) is lower with the presence of supraphysiological ketones as in the case of chronic ketogenic diet (KD) and diabetic ketoacidosis (DKA). This study aimed to determine changes in EtCO2 upon short term KD. METHODS: Healthy subjects were screened not to have conditions that exerts abnormal EtCO2 nor contraindicated for KD. Subjects underwent seven days of KD while the EtCO2 and blood ketone (beta-hydroxybutyrate; ß-OHB) parameters were sampled at day zero (t0) and seven (t7) of ketosis respectively. Statistically, the t-test and Pearson's coefficient were conducted to determine the changes and correlation of both parameters. RESULTS: 12 subjects completed the study. The mean score ± standard deviation (SD) for EtCO2 were 35.08 ± 3.53 and 35.67 ± 3.31 mm Hg for t0 and t7 respectively. The mean score ±SD for ß-OHB were 0.07 ± 0.08 and 0.87 ± 0.84 mmol/L for t0 and t7 respectively. There was no significant difference of EtCO2 between the period of study (p > 0.05) but the ß-OHB increased during t7 (p < 0.05). There was also no correlation between the parameters. CONCLUSIONS: These findings suggest that EtCO2 may not be utilized to determine short term nutritional ketosis.


Asunto(s)
Cetoacidosis Diabética , Dieta Cetogénica , Ácido 3-Hidroxibutírico , Dióxido de Carbono , Humanos , Cetonas
9.
Med Biol Eng Comput ; 57(6): 1229-1245, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30734153

RESUMEN

Adverse childhood experiences have been suggested to cause changes in physiological processes and can determine the magnitude of the stress response which might have a significant impact on health later in life. To detect the stress response, biomarkers that represent both the Autonomic Nervous System (ANS) and Hypothalamic-Pituitary-Adrenal (HPA) axis are proposed. Among the available biomarkers, Heart Rate Variability (HRV) has been proven as a powerful biomarker that represents ANS. Meanwhile, salivary cortisol has been suggested as a biomarker that reflects the HPA axis. Even though many studies used multiple biomarkers to measure the stress response, the results for each biomarker were analyzed separately. Therefore, the objective of this study is to propose a fusion of ANS and HPA axis biomarkers in order to classify the stress response based on adverse childhood experience. Electrocardiograph, blood pressure (BP), pulse rate (PR), and salivary cortisol (SCort) measures were collected from 23 healthy participants; 11 participants had adverse childhood experience while the remaining 12 acted as the no adversity control group. HRV was then computed from the ECG and the HRV features were extracted. Next, the selected HRV features were combined with the other biomarkers using Euclidean distance (ed) and serial fusion, and the performance of the fused features was compared using Support Vector Machine. From the result, HRV-SCort using Euclidean distance achieved the most satisfactory performance with 80.0% accuracy, 83.3% sensitivity, and 78.3% specificity. Furthermore, the performance of the stress response classification of the fused biomarker, HRV-SCort, outperformed that of the single biomarkers: HRV (61% Accuracy), Cort (59.4% Accuracy), BP (78.3% accuracy), and PR (53.3% accuracy). From this study, it was proven that the fused biomarkers that represent both ANS and HPA (HRV-SCort) able to demonstrate a better classification performance in discriminating the stress response. Furthermore, a new approach for classification of stress response using Euclidean distance and SVM named as ed-SVM was proven to be an effective method for the HRV-SCort in classifying the stress response from PASAT. The robustness of this method is crucial in contributing to the effectiveness of the stress response measures and could further be used as an indicator for future health. Graphical abstract ᅟ.


Asunto(s)
Experiencias Adversas de la Infancia , Frecuencia Cardíaca/fisiología , Hidrocortisona/metabolismo , Saliva/metabolismo , Estrés Psicológico/metabolismo , Estrés Psicológico/fisiopatología , Biomarcadores/metabolismo , Entropía , Femenino , Humanos , Masculino , Dinámicas no Lineales , Máquina de Vectores de Soporte , Adulto Joven
10.
Technol Health Care ; 26(5): 785-794, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30124456

RESUMEN

BACKGROUND: Assessment of asthma outside of the hospital using a patient independent device is highly in demand due to the limitation of existing devices, which are manual and unreliable if patients are not cooperative. OBJECTIVE: The study aims to verify the use of newly developed human respiration, carbon dioxide (CO2) measurement device for the management of asthma outside of the hospital. METHOD: The data were collected from 60 subjects aged between 18-35 years via convenience sampling method reported in UTM Health Center using the device. Furthermore, the data were normalized and analyzed using descriptive statistics, t-test, and area (Az) under receiver operating characteristic curve (ROC). RESULT: Findings revealed that the normalized mean values of end-tidal carbon dioxide (EtCO2), Hjorth Activity (HA), and respiratory rate (RR) were lower in asthmatic compared with healthy subjects with minimum deviation from the mean. In addition, each parameter was found to significantly differ statistically for asthma and non-asthma with p< 0.05. Furthermore, the Az shows the strong association for the screening of asthma and non-asthma with an average of 0.71 (95% CI: 0.57-0.83), 0.77 (95% CI: 0.64-0.90), and 0.83 (95% CI: 0.73-0.94) for RR, EtCO2, and HA, respectively. CONCLUSIONS: This study demonstrates that the newly developed handheld human respiration CO2 measurement device may possibly be used as an effort-independent asthma management method outside of the hospital.


Asunto(s)
Asma/fisiopatología , Dióxido de Carbono/análisis , Espiración/fisiología , Monitoreo Ambulatorio/instrumentación , Adolescente , Adulto , Femenino , Humanos , Masculino , Pruebas de Función Respiratoria , Frecuencia Respiratoria , Adulto Joven
11.
Technol Health Care ; 26(4): 573-579, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29758955

RESUMEN

BACKGROUND: Fetal heart rate (FHR) monitoring device is highly demanded to assess the fetus health condition in home environments. Conventional standard devices such as ultrasonography and cardiotocography are expensive, bulky and uncomfortable and consequently not suitable for long-term monitoring. Herein, we report a device that can be used to measure fetal heart rate in clinical and home environments. METHODS: The proposed device measures and displays the FHR on a screen liquid crystal display (LCD). The device consists of hardware that comprises condenser microphone sensor, signal conditioning, microcontroller and LCD, and software that involves the algorithm used for processing the conditioned fetal heart signal prior to FHR display. The device's performance is validated based on analysis of variance (ANOVA) test. RESULTS: FHR data was recorded from 22 pregnant women during the 17th to 37th week of gestation using the developed device and two standard devices; AngelSounds and Electronic Stethoscope. The results show that F-value (1.5) is less than F𝑐𝑟𝑖𝑡, (3.1) and p-value (p> 0.05). Accordingly, there is no significant difference between the mean readings of the developed and existing devices. Hence, the developed device can be used for monitoring FHR in clinical and home environments.


Asunto(s)
Monitoreo Fetal/instrumentación , Monitoreo Fetal/métodos , Frecuencia Cardíaca Fetal/fisiología , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Embarazo , Reproducibilidad de los Resultados
12.
Comput Methods Programs Biomed ; 153: 171-184, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29157449

RESUMEN

This paper presents a method that able to predict the paroxysmal atrial fibrillation (PAF). The method uses shorter heart rate variability (HRV) signals when compared to existing methods, and achieves good prediction accuracy. PAF is a common cardiac arrhythmia that increases the health risk of a patient, and the development of an accurate predictor of the onset of PAF is clinical important because it increases the possibility to electrically stabilize and prevent the onset of atrial arrhythmias with different pacing techniques. We propose a multi-objective optimization algorithm based on the non-dominated sorting genetic algorithm III for optimizing the baseline PAF prediction system, that consists of the stages of pre-processing, HRV feature extraction, and support vector machine (SVM) model. The pre-processing stage comprises of heart rate correction, interpolation, and signal detrending. After that, time-domain, frequency-domain, non-linear HRV features are extracted from the pre-processed data in feature extraction stage. Then, these features are used as input to the SVM for predicting the PAF event. The proposed optimization algorithm is used to optimize the parameters and settings of various HRV feature extraction algorithms, select the best feature subsets, and tune the SVM parameters simultaneously for maximum prediction performance. The proposed method achieves an accuracy rate of 87.7%, which significantly outperforms most of the previous works. This accuracy rate is achieved even with the HRV signal length being reduced from the typical 30 min to just 5 min (a reduction of 83%). Furthermore, another significant result is the sensitivity rate, which is considered more important that other performance metrics in this paper, can be improved with the trade-off of lower specificity.


Asunto(s)
Algoritmos , Fibrilación Atrial/fisiopatología , Electrocardiografía , Humanos , Máquina de Vectores de Soporte
13.
J Breath Res ; 12(2): 026003, 2018 01 04.
Artículo en Inglés | MEDLINE | ID: mdl-28928295

RESUMEN

The development of a human respiration carbon dioxide (CO2) measurement device to evaluate cardiorespiratory status inside and outside a hospital setting has proven to be a challenging area of research over the few last decades. Hence, we report a real-time, user operable CO2 measurement device using an infrared CO2 sensor (Arduino Mega2560) and a thin film transistor (TFT, 3.5″), incorporated with low pass (cut-off frequency, 10 Hz) and moving average (span, 8) filters. The proposed device measures features such as partial end-tidal carbon dioxide (EtCO2), respiratory rate (RR), inspired carbon dioxide (ICO2), and a newly proposed feature-Hjorth activity-that annotates data with the date and time from a real-time clock, and is stored onto a secure digital (SD) card. Further, it was tested on 22 healthy subjects and the performance (reliability, validity and relationship) of each feature was established using (1) an intraclass correlation coefficient (ICC), (2) standard error measurement (SEM), (3) smallest detectable difference (SDD), (4) Bland-Altman plot, and (5) Pearson's correlation (r). The SEM, SDD, and ICC values for inter- and intra-rater reliability were less than 5% and more than 0.8, respectively. Further, the Bland-Altman plot demonstrates that mean differences ± standard deviations for a set limit were 0.30 ± 0.77 mmHg, -0.34 ± 1.41 mmHg and 0.21 ± 0.64 breath per minute (bpm) for CO2, EtCO2 and RR. The findings revealed that the developed device is highly reliable, providing valid measurements for CO2, EtCO2, ICO2 and RR, and can be used in clinical settings for cardiorespiratory assessment. This research also demonstrates that EtCO2 and RR (r, -0.696) are negatively correlated while EtCO2 and activity (r, 0.846) are positively correlated. Thus, simultaneous measurement of these features may possibly assist physicians in understanding the subject's cardiopulmonary status. In future, the proposed device will be tested with asthmatic patients for use as an early screening tool outside a hospital setting.


Asunto(s)
Pruebas Respiratorias/instrumentación , Pruebas Respiratorias/métodos , Dióxido de Carbono/análisis , Sistemas de Computación , Corazón/fisiología , Respiración , Adulto , Femenino , Humanos , Masculino , Postura , Reproducibilidad de los Resultados , Procesamiento de Señales Asistido por Computador , Adulto Joven
14.
Comput Methods Programs Biomed ; 134: 187-96, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27480743

RESUMEN

This paper proposes a method that predicts the onset of paroxysmal atrial fibrillation (PAF), using heart rate variability (HRV) segments that are shorter than those applied in existing methods, while maintaining good prediction accuracy. PAF is a common cardiac arrhythmia that increases the health risk of a patient, and the development of an accurate predictor of the onset of PAF is clinical important because it increases the possibility to stabilize (electrically) and prevent the onset of atrial arrhythmias with different pacing techniques. We investigate the effect of HRV features extracted from different lengths of HRV segments prior to PAF onset with the proposed PAF prediction method. The pre-processing stage of the predictor includes QRS detection, HRV quantification and ectopic beat correction. Time-domain, frequency-domain, non-linear and bispectrum features are then extracted from the quantified HRV. In the feature selection, the HRV feature set and classifier parameters are optimized simultaneously using an optimization procedure based on genetic algorithm (GA). Both full feature set and statistically significant feature subset are optimized by GA respectively. For the statistically significant feature subset, Mann-Whitney U test is used to filter non-statistical significance features that cannot pass the statistical test at 20% significant level. The final stage of our predictor is the classifier that is based on support vector machine (SVM). A 10-fold cross-validation is applied in performance evaluation, and the proposed method achieves 79.3% prediction accuracy using 15-minutes HRV segment. This accuracy is comparable to that achieved by existing methods that use 30-minutes HRV segments, most of which achieves accuracy of around 80%. More importantly, our method significantly outperforms those that applied segments shorter than 30 minutes.


Asunto(s)
Fibrilación Atrial/fisiopatología , Frecuencia Cardíaca , Algoritmos , Humanos , Máquina de Vectores de Soporte
15.
J Med Eng ; 2015: 701520, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-27006940

RESUMEN

This paper leads to developing a Labview based ECG patient monitoring system for cardiovascular patient using Simple Mail Transfer Protocol technology. The designed device has been divided into three parts. First part is ECG amplifier circuit, built using instrumentation amplifier (AD620) followed by signal conditioning circuit with the operation amplifier (lm741). Secondly, the DAQ card is used to convert the analog signal into digital form for the further process. Furthermore, the data has been processed in Labview where the digital filter techniques have been implemented to remove the noise from the acquired signal. After processing, the algorithm was developed to calculate the heart rate and to analyze the arrhythmia condition. Finally, SMTP technology has been added in our work to make device more communicative and much more cost-effective solution in telemedicine technology which has been key-problem to realize the telediagnosis and monitoring of ECG signals. The technology also can be easily implemented over already existing Internet.

16.
IEEE Trans Biomed Eng ; 56(11): 2594-603, 2009 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-19628449

RESUMEN

In this paper, we investigate the use of heart rate variability (HRV) for automatic newborn seizure detection. The proposed method consists of a sequence of processing steps, namely, obtaining HRV from the ECG, extracting a discriminating HRV feature set, selecting an optimal subset from the full feature set, and, finally, classifying the HRV into seizure/nonseizure using a supervised statistical classifier. Due to the fact that HRV signals are nonstationary, a set of time-frequency features from the newborn HRV is proposed and extracted. In order to achieve efficient HRV-based automatic newborn seizure detection, a two-phase wrapper-based feature selection technique is used to select the feature subset with minimum redundancy and maximum class discriminability. Tested on ECG recordings obtained from eight newborns with identified EEG seizure, the proposed HRV-based neonatal seizure detection algorithm achieved 85.7% sensitivity and 84.6% specificity. These results suggest that the HRV is sensitive to changes in the cardioregulatory system induced by the seizure, and therefore, can be used as a basis for an automatic seizure detection.


Asunto(s)
Frecuencia Cardíaca/fisiología , Enfermedades del Recién Nacido/diagnóstico , Convulsiones/diagnóstico , Procesamiento de Señales Asistido por Computador , Electrocardiografía/métodos , Electroencefalografía/métodos , Humanos , Recién Nacido , Enfermedades del Recién Nacido/fisiopatología , Convulsiones/fisiopatología , Factores de Tiempo
17.
Artículo en Inglés | MEDLINE | ID: mdl-19163779

RESUMEN

We propose a new seizure detection framework based on combination of information extracted from newborn multi-channel electroencephalogram (EEG) and heart rate variability (HRV). Two approaches are investigated for the combination of EEG and HRV, namely; feature fusion and classifier/decision fusion. The feature fusion was performed by concatenating the features vectors extracted from the EEG and the HRV signals while the classifier fusion was accomplished by fusing the independent decisions from individual classifiers of EEG and HRV. Both proposed schemes consist of a sequence of processing steps, namely; preprocessing, feature extraction, feature selection and finally the combination. We have shown that both proposed approaches lead to improved performance of newborn seizure detection compared to either EEG or HRV based seizure detectors.


Asunto(s)
Corteza Cerebral/fisiopatología , Diagnóstico por Computador/métodos , Electroencefalografía/métodos , Frecuencia Cardíaca/fisiología , Convulsiones/diagnóstico , Procesamiento de Señales Asistido por Computador , Algoritmos , Mapeo Encefálico/métodos , Diagnóstico por Computador/instrumentación , Procesamiento Automatizado de Datos , Potenciales Evocados , Humanos , Recién Nacido , Modelos Neurológicos , Reconocimiento de Normas Patrones Automatizadas , Convulsiones/fisiopatología , Factores de Tiempo
18.
Australas Phys Eng Sci Med ; 29(1): 67-72, 2006 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-16623224

RESUMEN

The ECG has been much neglected in automatic seizure detection in the newborn. Changes in heart rate and ECG rhythm are often found in animal and adult patients with seizure. However, little is known about heart rate variability (HRV) changes in human neonate during seizure. Results of ongoing time-frequency research are presented here with the aim to compare the performance of various time-frequency distributions (TFDs) when applied to HRV time series for non-seizure and seizure newborns. The TFDs studied are the Wigner-Ville (WVD), the Spectrogram (SP), the Choi-Williams (CWD) and the Modified B (MBD) distributions. Based on our preliminary results, our current conclusion is MBD outperforms other TFDs in terms of time-frequency resolution, cross-terms suppression and to represent the newborn HRV signals of non-seizure and seizure which are closely-spaced components in the time-frequency domain.


Asunto(s)
Algoritmos , Arritmias Cardíacas/diagnóstico , Diagnóstico por Computador/métodos , Electrocardiografía/métodos , Epilepsia Benigna Neonatal/diagnóstico , Frecuencia Cardíaca , Tamizaje Neonatal/métodos , Arritmias Cardíacas/complicaciones , Epilepsia Benigna Neonatal/complicaciones , Análisis de Fourier , Humanos , Recién Nacido , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA