1.
IEEE Trans Biomed Circuits Syst ; 14(3): 545-557, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32203026

RESUMEN

The recovery of sparse signals given their linear mapping on lower-dimensional spaces can be partitioned into a support estimation phase and a coefficient estimation phase. We propose to estimate the support with an oracle based on a deep neural network trained jointly with the linear mapping at the encoder. The divination of the oracle is then used to estimate the coefficients by pseudo-inversion. This architecture allows the definition of an encoding-decoding scheme with state-of-the-art recovery capabilities when applied to biological signals such as ECG and EEG, thus allowing extremely low-complex encoders. As an additional feature, oracle-based recovery is able to self-assess, by indicating with remarkable accuracy chunks of signals that may have been reconstructed with a non-satisfactory quality. This self-assessment capability is unique in the CS literature and paves the way for further improvements depending on the requirements of the specific application. As an example, our scheme is able to satisfyingly compress by a factor of 2.67 an ECG or EEG signal with a complexity equivalent to only 24 signed sums per processed sample.


Asunto(s)
Electrocardiografía/métodos , Electroencefalografía/métodos , Redes Neurales de la Computación , Procesamiento de Señales Asistido por Computador , Encéfalo/fisiología , Frecuencia Cardíaca/fisiología , Humanos
2.
IEEE Trans Biomed Circuits Syst ; 11(6): 1278-1289, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-28920907

RESUMEN

In recent years, compressed sensing (CS) has proved to be effective in lowering the power consumption of sensing nodes in biomedical signal processing devices. This is due to the fact the CS is capable of reducing the amount of data to be transmitted to ensure correct reconstruction of the acquired waveforms. Rakeness-based CS has been introduced to further reduce the amount of transmitted data by exploiting the uneven distribution to the sensed signal energy. Yet, so far no thorough analysis exists on the impact of its adoption on CS decoder performance. The latter point is of great importance, since body-area sensor network architectures may include intermediate gateway nodes that receive and reconstruct signals to provide local services before relaying data to a remote server. In this paper, we fill this gap by showing that rakeness-based design also improves reconstruction performance. We quantify these findings in the case of ECG signals and when a variety of reconstruction algorithms are used either in a low-power microcontroller or a heterogeneous mobile computing platform.


Asunto(s)
Compresión de Datos/métodos , Electrocardiografía/métodos , Algoritmos , Procesamiento de Señales Asistido por Computador , Tecnología Inalámbrica
3.
IEEE Trans Biomed Circuits Syst ; 10(1): 149-62, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26276997

RESUMEN

We report the design and implementation of an Analog-to-Information Converter (AIC) based on Compressed Sensing (CS). The system is realized in a CMOS 180 nm technology and targets the acquisition of bio-signals with Nyquist frequency up to 100 kHz. To maximize performance and reduce hardware complexity, we co-design hardware together with acquisition and reconstruction algorithms. The resulting AIC outperforms previously proposed solutions mainly thanks to two key features. First, we adopt a novel method to deal with saturations in the computation of CS measurements. This allows no loss in performance even when 60% of measurements saturate. Second, the system is able to adapt itself to the energy distribution of the input by exploiting the so-called rakeness to maximize the amount of information contained in the measurements. With this approach, the 16 measurement channels integrated into a single device are expected to allow the acquisition and the correct reconstruction of most biomedical signals. As a case study, measurements on real electrocardiograms (ECGs) and electromyograms (EMGs) show signals that these can be reconstructed without any noticeable degradation with a compression rate, respectively, of 8 and 10.


Asunto(s)
Compresión de Datos/métodos , Procesamiento de Señales Asistido por Computador/instrumentación , Algoritmos , Electrocardiografía/instrumentación , Electromiografía/instrumentación , Diseño de Equipo , Humanos