Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 243
Filtrar
1.
Facts Views Vis Obgyn ; 16(2): 163-172, 2024 06.
Artículo en Inglés | MEDLINE | ID: mdl-38950530

RESUMEN

Background: More than two decades ago, the advent of robotic laparoscopic surgery marked a significant milestone, featuring the introduction of the AESOP robotic endoscope control system and the ZEUS robotic surgery system. The latter, equipped with distinct arms for the laparoscope and surgical instruments, was designed to accommodate remote connections, enabling the practice of remote telesurgery as early as 2001. Subsequent technological progress has given rise to a range of options in today's market, encompassing multi-port and single-port systems, both rigid and flexible, across various price points, with further growth anticipated. Objective: This article serves as an indispensable guide for gynaecological surgeons with an interest in embracing robotic surgery. Materials and methods: Drawing insights from the experience of the Strasbourg training centre for minimally invasive surgery (IRCAD), this article offers a comprehensive overview of existing robotic platforms in the market, as well as those in development. Results: Robotic surgical systems not only streamline established operative methods but also broaden the scope of procedures, including intra- and transluminal surgeries. As integral components of the digital surgery ecosystem, these robotic systems actively contribute to the increasing integration and adoption of advanced technologies, such as artificial intelligence-based data analysis and support systems. Conclusion: Robotic surgery is increasingly being adopted in clinical practice. With the growing number of systems available on the marketplace, the primary challenge lies in identifying the optimal platform for each specific procedure and patient. The seamless integration of robotic systems with artificial intelligence, image-guided surgery, and telesurgery presents undeniable advantages, enhancing the precision and effectiveness of surgical interventions. What is new?: This article provides a guide to the robotic platforms available on the market and those in development for gynaecologists interested in robotic surgery.

2.
Hernia ; 26(6): 1669-1678, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35536371

RESUMEN

BACKGROUND: Because of the complexity of the intra-abdominal anatomy in the posterior approach, a longer learning curve has been observed in laparoscopic transabdominal preperitoneal (TAPP) inguinal hernia repair. Consequently, automatic tools using artificial intelligence (AI) to monitor TAPP procedures and assess learning curves are required. The primary objective of this study was to establish a deep learning-based automated surgical phase recognition system for TAPP. A secondary objective was to investigate the relationship between surgical skills and phase duration. METHODS: This study enrolled 119 patients who underwent the TAPP procedure. The surgical videos were annotated (delineated in time) and split into seven surgical phases (preparation, peritoneal flap incision, peritoneal flap dissection, hernia dissection, mesh deployment, mesh fixation, peritoneal flap closure, and additional closure). An AI model was trained to automatically recognize surgical phases from videos. The relationship between phase duration and surgical skills were also evaluated. RESULTS: A fourfold cross-validation was used to assess the performance of the AI model. The accuracy was 88.81 and 85.82%, in unilateral and bilateral cases, respectively. In unilateral hernia cases, the duration of peritoneal incision (p = 0.003) and hernia dissection (p = 0.014) detected via AI were significantly shorter for experts than for trainees. CONCLUSION: An automated surgical phase recognition system was established for TAPP using deep learning with a high accuracy. Our AI-based system can be useful for the automatic monitoring of surgery progress, improving OR efficiency, evaluating surgical skills and video-based surgical education. Specific phase durations detected via the AI model were significantly associated with the surgeons' learning curve.


Asunto(s)
Hernia Inguinal , Laparoscopía , Humanos , Hernia Inguinal/cirugía , Herniorrafia/métodos , Mallas Quirúrgicas , Inteligencia Artificial , Laparoscopía/métodos
3.
Br J Surg ; 107(13): 1780-1790, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32869868

RESUMEN

BACKGROUND: A surgical approach preserving functional adrenal tissue allows biochemical cure while avoiding the need for lifelong steroid replacement. The aim of this experimental study was to evaluate the impact of intraoperative imaging during bilateral partial adrenalectomy on remnant perfusion and function. METHODS: Five pigs underwent bilateral posterior retroperitoneoscopic central adrenal gland division (9 divided glands, 1 undivided). Intraoperative perfusion assessment included computer-assisted quantitative fluorescence imaging, contrast-enhanced CT, confocal laser endomicroscopy (CLE) and local lactate sampling. Specimen analysis after completion adrenalectomy (10 adrenal glands) comprised mitochondrial activity and electron microscopy. RESULTS: Fluorescence signal intensity evolution over time was significantly lower in the cranial segment of each adrenal gland (mean(s.d.) 0·052(0·057) versus 0·133(0·057) change in intensity per s for cranial versus caudal parts respectively; P = 0·020). Concordantly, intraoperative CT in the portal phase demonstrated significantly lower contrast uptake in cranial segments (P = 0·031). In CLE, fluorescein contrast was observed in all caudal segments, but in only four of nine cranial segments (P = 0·035). Imaging findings favouring caudal perfusion were congruent, with significantly lower local capillary lactate levels caudally (mean(s.d.) 5·66(5·79) versus 11·58(6·53) mmol/l for caudal versus cranial parts respectively; P = 0·008). Electron microscopy showed more necrotic cells cranially (P = 0·031). There was no disparity in mitochondrial activity (respiratory rates, reactive oxygen species and hydrogen peroxide production) between the different segments. CONCLUSION: In a model of bilateral partial adrenalectomy, three intraoperative imaging modalities consistently discriminated between regular and reduced adrenal remnant perfusion. By avoiding circumferential dissection, mitochondrial function was preserved in each segment of the adrenal glands. Surgical relevance Preservation of adrenal tissue to maintain postoperative function is essential in bilateral and hereditary adrenal pathologies. There is interindividual variation in residual adrenocortical stress capacity, and the minimal functional remnant size is unknown. New intraoperative imaging technologies allow improved remnant size and perfusion assessment. Fluorescence imaging and contrast-enhanced intraoperative CT showed congruent results in evaluation of perfusion. Intraoperative imaging can help to visualize the remnant vascular supply in partial adrenalectomy. Intraoperative assessment of perfusion may foster maximal functional tissue preservation in bilateral adrenal pathologies and procedures.


ANTECEDENTES: Un abordaje quirúrgico que preserve la función del tejido suprarrenal permite lograr la curación bioquímica, a la vez que evita la necesidad de tratamiento sustitutivo con corticoides de por vida. El objetivo de este estudio experimental fue evaluar el impacto de las técnicas de imagen intraoperatorias en la suprarrenalectomía parcial (partial adrenalectomy, AE) bilateral sobre la perfusión y función del remanente glandular. MÉTODOS: Cinco cerdos fueron sometidos a una división bilateral central de la glándula suprarrenal por retroperitoneoscopia posterior (n = 9, 1 sin dividir). Durante la intervención, la evaluación de la perfusión incluyó la fluorescencia con cuantificación asistida por ordenador (Realidad Aumentada basada en la Fluorescencia, FLuorescence-based Enhanced Reality, FLER), tomografía computarizada (computed tomography, CT), endomicroscopia con laser confocal (confocal laser endomicroscopy, CLE) y un muestreo local de lactato. El análisis de la pieza quirúrgica tras completar la AE (n = 10) incluyó actividad mitocondrial y microscopia electrónica. RESULTADOS: La evolución de la intensidad de la señal de fluorescencia a lo largo del tiempo (ΔI/s) fue significativamente más baja en el segmento craneal de cada una de las glándulas (0,052 ± 0,057 craneal versus 0,133 ± 0,057 caudal, P = 0,02). De forma concordante, la CT intraoperatoria en la fase portal demostró una captación de contraste significativamente más baja en los segmentos craneales (P = 0,03). En la CLE, el contraste de fluoresceína se observó en todos los segmentos caudales, pero solo en el 44% de los segmentos craneales (P = 0,04). Los hallazgos obtenidos en las pruebas de imagen favorables a la perfusión caudal fueron congruentes con niveles significativamente más bajos de lactato capilar a nivel local (11,58 ± 6,53 mmol/L craneal versus 5,66 ± 5,79 mmol/L caudal, P = 0,008). A nivel craneal, la microscopia electrónica mostró más células necróticas (P = 0,03). La actividad mitocondrial (tasas de respiración, especies reactivas de oxígeno y producción de H2 O2 ) no mostraron disparidad entre los diferentes segmentos. CONCLUSIÓN: En un modelo de AE parcial bilateral, las tres modalidades de pruebas de imagen intraoperatorias podrían discriminar de forma consistente una perfusión regular y reducida del remanente suprarrenal. Al evitar una disección circunferencial, se preservó la función mitocondrial en cada segmento de las glándulas suprarrenales.


Asunto(s)
Glándulas Suprarrenales/irrigación sanguínea , Glándulas Suprarrenales/diagnóstico por imagen , Adrenalectomía/métodos , Cuidados Intraoperatorios/métodos , Glándulas Suprarrenales/fisiología , Glándulas Suprarrenales/cirugía , Animales , Biomarcadores/metabolismo , Femenino , Ácido Láctico/metabolismo , Masculino , Microscopía Confocal , Microscopía Electrónica , Mitocondrias/metabolismo , Modelos Animales , Imagen Óptica , Periodo Posoperatorio , Sus scrofa , Tomografía Computarizada por Rayos X
4.
Colorectal Dis ; 22(11): 1749-1753, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32443182

RESUMEN

AIM: Transanal total mesorectal excision is a promising novel sphincter-saving procedure for low rectal cancer. However, the transanal bottom-up dissection is associated with increased rates of iatrogenic urethral injuries. Near-infrared fluorescence (NIRF) imaging, given its deeper tissue penetration, has been explored in a limited number of studies for enhanced intra-operative urethral visualization. In this study, we explored the feasibility of a novel, ultrabright, biocompatible fluorescent polymer to coat urinary catheters for the purpose of intra-operative urethral visualization. METHODS: In an ex vivo experiment, using a near-infrared laparoscope, the fluorescent signal of a coated catheter (near-infrared coating of equipment, NICE) was qualitatively and quantitatively compared to the signal of indocyanine green (ICG)/Instillagel® mixtures and ICG-filled catheters at several concentrations. Also, in three male human torsos, using fluorescent urinary catheters, NIRF-guided perineal dissections and a transanal total mesorectal excision were performed. Intra-operative NIRF-based urethral visualization was performed systematically. RESULTS: During the qualitative and quantitative fluorescence signal assessment, NICE-coated catheters were clearly superior to the ICG-based solutions. In the cadaveric experiments, enhanced urethral visualization was possible even at early stages of dissection, when the organ was covered by several tissue layers. CONCLUSIONS: NICE-coated catheters represent a promising potential to allow for NIRF-based intra-operative urethral visualization.


Asunto(s)
Imagen Óptica , Uretra , Cadáver , Humanos , Verde de Indocianina , Masculino , Perineo/cirugía , Uretra/diagnóstico por imagen , Uretra/cirugía
5.
Hernia ; 23(6): 1175-1185, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31312941

RESUMEN

PURPOSE: To evaluate the feasibility and safety of a new percutaneous image-guided surgery technique to simulate a hernia repair using hydrogel. MATERIALS AND METHODS: A comparative prospective study was conducted in animals, with survival. Five pigs without any hernias were used. A hydrogel was injected at a site corresponding to the preperitoneal inguinal region. This procedure was performed bilaterally. An image-guided needle (ultrasound and computed tomography) was used, through which the material was injected. After survival, the local and systemic inflammatory reaction generated by the new material, was studied. RESULTS: All animals survived the procedure. No hemorrhagic or infectious complications were reported. The solidification of the material occurred as expected. In eight out of ten cases, the material was found in the planned site. No systemic inflammatory reaction secondary to the administration of hydrogel was reported. The adhesion of the material to surrounding tissues was satisfactory. CONCLUSION: The introduction of a liquid material which solidifies after injection in a short time (hydrogel) using a needle is feasible. The combined CT-scan and US image guidance allows for the percutaneous placement of the needle in the required location. The introduced hydrogel remains in this space, corresponding to the inguinal region, without moving. The placed hydrogel compresses the posterior wall composed of the transversalis fascia, supporting the potential use of hydrogel for hernia defects.


Asunto(s)
Materiales Biocompatibles/administración & dosificación , Hernia Inguinal/cirugía , Herniorrafia/métodos , Hidrogeles/administración & dosificación , Cirugía Asistida por Computador/métodos , Pared Abdominal/diagnóstico por imagen , Animales , Fascia , Estudios de Factibilidad , Femenino , Ingle/diagnóstico por imagen , Hernia Inguinal/diagnóstico por imagen , Masculino , Estudios Prospectivos , Porcinos , Tomografía Computarizada por Rayos X , Ultrasonografía
6.
Rev. med. Rosario ; 85(1): 34-34, ene.-abr. 2019.
Artículo en Inglés | LILACS | ID: biblio-1053022

RESUMEN

BACKGROUND: When a major hepatic resection is necessary, sometimes the future liver remnant is not enough to maintain sufficient liver function and patients are more likely to develop liver failure after surgery. AIM: To test the hypothesis that performing a percutaneous radiofrecuency liver partition plus percutaneous portal vein embolization (PRALPPS) for stage hepatectomy in pigs is feasible. METHODS: Four pigs (Sus scrofa domesticus) both sexes with weights between 25 to 35 kg underwent percutaneous portal vein embolization with coils of the left portal vein. By contrasted CT, the difference between the liver parenchyma corresponding to the embolized zone and the normal one was identified. Immediately, using the fusion of images between ultrasound and CT as a guide, radiofrequency needles were placed percutaneouslyand then ablated until the liver partition was complete. Finally, hepatectomy was completed with a laparoscopic approach. RESULTS: All animals have survived the procedures, with no reported complications. The successful portal embolization process was confirmed both by portography and CT. In the macroscopic analysis of the pieces, the depth of the ablation was analyzed. The hepatic hilum was respected. On the other hand, the correct position of the embolization material on the left portal vein could be also observed. CONCLUSION: "Percutaneous radiofrequency assisted liver partition with portal vein embolization" (PRALLPS) is a feasible procedure (AU)


Asunto(s)
Animales , Masculino , Femenino , Vena Porta , Ablación por Catéter , Embolización Terapéutica , Hepatectomía/métodos , Porcinos , Ablación por Radiofrecuencia
7.
J Visc Surg ; 156(5): 381-386, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30885707

RESUMEN

INTRODUCTION: Common bile duct lithiasis after Roux-en-Y gastric bypass (RYGB) or upper gastrointestinal stenosis has become a challenging problem nowadays, especially as obesity surgery is increasing. In this study, we assess the feasibility and performance of laparoscopy-assisted transgastric endoscopic retrograde cholangiopancreatography (LAERCP) and describe its technique. METHODS: A retrospective review of a prospectively collected database of consecutive patients undergoing a LAERCP between February 2014 and May 2015 was performed at a single institution. Indications were common bile duct lithiasis associated with acute or past episodes of cholangitis and pancreatitis. Endoscopic access to the gastric remnant was obtained laparoscopically. RESULTS: In total 5 cases were identified. Four of them had undergone a RYGB and one of them presented a benign esophageal peptic stenosis, not allowing peroral gastric access. Biliary cannulation using LAERCP associated with sphincterotomy and stone extraction was successfully achieved in all patients. Mean duration of the entire procedure was 134minutes (range: 66-200min). No early major complications were observed and the mean postoperative hospital stay was 4 days (range: 2-5 days). CONCLUSIONS: LAERCP is a safe and successful procedure for the treatment of common bile duct lithiasis when conventional biliary access is not feasible, notably after RYGB. Larger trials still need to be performed to evaluate efficacy, technical success, and complications related to this technique.


Asunto(s)
Colangiopancreatografia Retrógrada Endoscópica/métodos , Cálculos Biliares/terapia , Laparoscopía , Esfinterotomía Endoscópica/métodos , Adulto , Femenino , Estudios de Seguimiento , Cálculos Biliares/diagnóstico por imagen , Humanos , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
8.
Tech Coloproctol ; 23(1): 53-63, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30656579

RESUMEN

BACKGROUND: Real-time stereotactic navigation for transanal total mesorectal excision has been demonstrated to be feasible in small pilot series using laparoscopic techniques. The possibility of real-time stereotactic navigation coupled with robotics has not been previously explored in a clinical setting. METHODS: After pre-clinical assessment, and configuration of a robotic-assisted navigational system, two patients with locally advanced rectal cancer were selected for enrollment into a pilot study designed to assess the feasibility of navigation coupled with the robotic da Vinci Xi platform via TilePro interface. In one case, fluorescence-guided surgery was also used as an adjunct for structure localization, with local administration of indocyanine green into the ureters and at the tumor site. RESULTS: Each operation was successfully completed with a robotic-assisted approach; image-guided navigation provided computed accuracy of ± 4.5 to 4.6 mm. The principle limitation encountered was navigation signal dropout due to temporary loss of direct line-of-sight with the navigational system's infrared camera. Subjectively, the aid of navigation assisted the operating surgeon in identifying critical anatomical planes. The combination of fluorescence with image-guided surgery further augmented the surgeon's perception of the operative field. CONCLUSIONS: The combination of stereotactic navigation and robotic surgery is feasible, although some limitations and technical challenges were observed. For complex surgery, the addition of navigation to robotics can improve surgical precision. This will likely represent the next step in the evolution of robotics and in the development of digital surgery.


Asunto(s)
Laparoscopía/métodos , Neuronavegación/métodos , Neoplasias del Recto/cirugía , Procedimientos Quirúrgicos Robotizados/métodos , Técnicas Estereotáxicas , Cirugía Asistida por Computador/métodos , Adulto , Anciano , Estudios de Factibilidad , Femenino , Humanos , Masculino , Ilustración Médica , Proyectos Piloto
9.
Annu Int Conf IEEE Eng Med Biol Soc ; 2019: 162-165, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31945869

RESUMEN

The treatment of choice for the unresectable cholangiocarcinoma is based on biliary decompression procedures. Despite stent placement is the standard of care, it is related to well-known complications. Hence, alternative techniques were proposed. Ideally, they should guarantee an adequate intraductal disobstruction, without injuring the surrounding tissues.This pre-clinical study aims to investigate the thermal effects of the laser ablation (LA) in the biliary tree, in terms of intraductal and surrounding tissue temperature achieved with different laser settings. The common bile ducts (in their upper and lower portions) of two pigs were ablated for 6 minutes with a diode laser at 3 W and 5 W. A custom-made laser applicator was used to obtain a circumferential ablation within the ducts. The intraductal temperature (Tid) was monitored by means of a fiber Bragg grating (FBG) sensor, while an infrared thermal camera monitored the T distribution in the surrounding tissues (Tsup). A maximum T difference of 65 °C and 57 °C was evidenced between the two power settings for the Tid measured in the upper and lower ducts, respectively. The mean difference between Tid and the averaged Tsup values was evaluated. At 5 W, a difference of 37±3 °C and 44±10 °C were obtained for the upper and lower ducts, respectively. At 3 W, a T difference of 2±1 °C was obtained for the upper biliary duct, while a difference of 8±1 °C was documented for the lower duct. Based on the results obtained in this preliminary study, the possibility to equip the laser probe with temperature sensor can improve the control and the safety of the procedure; this solution will guarantee the monitoring of the treatment while preserving the lumen and the surrounding structures.


Asunto(s)
Conductos Biliares , Terapia por Láser , Animales , Láseres de Semiconductores , Porcinos , Temperatura
10.
Dis Esophagus ; 32(2)2019 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-30295748

RESUMEN

Flexible endoscopy has evolved to the point that it includes many endoluminal procedures that once required open or laparoscopic surgery, for instance, antireflux surgery, pyloromyotomy, mucosal and submucosal tumor resections, and even full-thickness resection. However, these procedures remain technically demanding due to flexible technology issues: difficult imaging, limited energy devices, lack of staplers, unsatisfactory suturing abilities, and so on. Transgastric laparoscopy or hybrid laparoscopy/flex endoscopy has been described for almost two decades as an alternative to a pure endoluminal approach, mainly for pancreatic pseudocyst drainage and full-thickness and mucosal resection of various lesions. The approach has never been widely adopted mostly due to cumbersome and difficult to maintain methods of gastric access. We propose to expand the indications of transgastric laparoscopy by using novel endoscopically placed ports to replicate endoscopic procedures particularly in the difficult to access proximal stomach such as endoluminal antireflux surgery. Under general anesthesia, five female pigs (mean weight: 27.6 kg) had endoscopic placement of 3, 5 mm intragastric ports (Endo-TAGSS, Leakwood KS, USA) using a technique similar to percutaneous endoscopic gastrostomy. A 5-mm laparoscope was used for visualization. Laparoendoscopic-assisted plication of the gastroesophageal junction (GEJ) was performed using 3-0 interrupted sutures (Polysorb®, Covidien, Mansfield, MA, USA). A functional lumen imagine probe (EndoFLIP®, Crospon, Inc., Galway, Ireland) was used to measure diameter, cross sectional area (CSA), distensibility, and compliance of GEJ before and after intervention. Once the TAGSS ports were removed, the gastrotomies were closed by using endoscopic over-the-scope clips. At the end of the procedure, animals were euthanized. Five laparoendoscopic-assisted endoluminal plications were performed. The mean operative time was 65.6 min (Endoscopic evaluation: 3.2 min, TAGSS Insertion: 11 min, EndoFLIP evaluation + GEJ Plication: 43.25 min, gastric wall closure: 15 minutes). In all cases, this technique was effective and allowed to achieve an adequate GEJ plication by endoscopic grading and EndoFLIP measurements. Median pre-plication GEJ diameter (D) and median pre-plication GEJ cross-sectional area (CSA) were 11.42 mm (8.6-13.6 mm) and 104.8 mm2 (58-146 mm2). After the procedure, these values were decreased to 6.14 mm (5.7-6.6 mm) and 29.8 mm2 (25-34 mm2) respectively (p = 0.0079). Median pre-plication distensibility (d) and compliance (C) were 7.87 mm2/mmHg (2.4-22.69 mm2/mmHg) and 190.56 mm3/mmHg (70.9-502.8 mm3/mmHg). After the procedure, these values decreased to 1.5 mm2/mmHg (0.7-2.2 mm2/mmHg) and 52.17 mm3/mmHg (21.9-98.7 mm3/mmHg) respectively (p = 0.0317). No intraoperative events were observed. Endoscopically, all valves were felt to be transitioned from a Hill grade 3 (normal state for the animal model) to a Hill grade 1 at the procedure completion. A hybrid laparoendoscopic approach is a feasible alternative for performing intragastric procedures with the assistance of conventional laparoscopic instruments; especially in cases where the intervention location limits the access to standard endoscopy or where endoscopic technology is inadequate. Further evaluation is planned in survival models and clinical trials.


Asunto(s)
Endoscopía Gastrointestinal/métodos , Unión Esofagogástrica/cirugía , Laparoscopía/métodos , Animales , Endoscopía Gastrointestinal/instrumentación , Femenino , Gastrostomía/instrumentación , Gastrostomía/métodos , Humanos , Modelos Animales , Tempo Operativo , Instrumentos Quirúrgicos , Técnicas de Sutura/instrumentación , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA