Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Imaging ; 10(9)2024 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-39330431

RESUMEN

Although several studies have been conducted on artificial intelligence (AI) use in mammography (MG), there is still a paucity of research on the diagnosis of metachronous bilateral breast cancer (BC), which is typically more challenging to diagnose. This study aimed to determine whether AI could enhance BC detection, achieving earlier or more accurate diagnoses than radiologists in cases of metachronous contralateral BC. We included patients who underwent unilateral BC surgery and subsequently developed contralateral BC. This retrospective study evaluated the AI-supported MG diagnostic system called FxMammo™. We evaluated the capability of FxMammo™ (FathomX Pte Ltd., Singapore) to diagnose BC more accurately or earlier than radiologists' assessments. This evaluation was supplemented by reviewing MG readings made by radiologists. Out of 1101 patients who underwent surgery, 10 who had initially undergone a partial mastectomy and later developed contralateral BC were analyzed. The AI system identified malignancies in six cases (60%), while radiologists identified five cases (50%). Notably, two cases (20%) were diagnosed solely by the AI system. Additionally, for these cases, the AI system had identified malignancies a year before the conventional diagnosis. This study highlights the AI system's effectiveness in diagnosing metachronous contralateral BC via MG. In some cases, the AI system consistently diagnosed cancer earlier than radiological assessments.

2.
Diagnostics (Basel) ; 14(15)2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-39125527

RESUMEN

BACKGROUND: High breast density found using mammographs (MGs) reduces positivity rates and is considered a risk factor for breast cancer. Research on the relationship between Volpara density grade (VDG) and compressed breast thickness (CBT) in the Japanese population is still lacking. Moreover, little attention has been paid to pseudo-dense breasts with CBT < 30 mm among high-density breasts. We investigated VDG, CBT, and apparent high breast density in patients with breast cancer. METHODS: Women who underwent MG and breast cancer surgery at our institution were included. VDG and CBT were measured. VDG was divided into a non-dense group (NDG) and a dense group (DG). RESULTS: This study included 419 patients. VDG was negatively correlated with CBT. The DG included younger patients with lower body mass index (BMI) and thinner CBT. In the DG, patients with CBT < 30 mm had lower BMI and higher VDG; however, no significant difference was noted in the positivity rate of the two groups. CONCLUSIONS: Younger women tend to have higher breast density, resulting in thinner CBT, which may pose challenges in detecting breast cancer on MGs. However, there was no significant difference in the breast cancer detection rate between CBT < 30 mm and CBT ≥ 30 mm.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA