Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Phys Rev Lett ; 112(14): 145004, 2014 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-24765979

RESUMEN

Detailed measurements of the electron densities, temperatures, and ionization states of compressed CH shells approaching pressures of 50 Mbar are achieved with spectrally resolved x-ray scattering. Laser-produced 9 keV x-rays probe the plasma during the transient state of three-shock coalescence. High signal-to-noise x-ray scattering spectra show direct evidence of continuum depression in highly degenerate warm dense matter states with electron densities ne>1024 cm-3. The measured densities and temperatures agree well with radiation-hydrodynamic modeling when accounting for continuum lowering in calculations that employ detailed configuration accounting.

2.
Rev Sci Instrum ; 83(2): 023901, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22380101

RESUMEN

We present a short working distance miniature x-ray emission spectrometer (miniXES) based on the cylindrical von Hamos geometry. We describe the general design principles for the spectrometer and detail a specific implementation that covers Kß and valence level emission from Fe. Large spatial and angular access to the sample region provides compatibility with environmental chambers, microprobe, and pump/probe measurements. The primary spectrometer structure and optic is plastic, printed using a 3-dimensional rapid-prototype machine. The spectrometer is inexpensive to construct and is portable; it can be quickly set up at any focused beamline with a tunable narrow bandwidth monochromator. The sample clearance is over 27 mm, providing compatibility with a variety of environment chambers. An overview is also given of the calibration and data processing procedures, which are implemented by a multiplatform user-friendly software package. Finally, representative measurements are presented. Background levels are below the level of the Kß(2, 5) valence emission, the weakest diagram line in the system, and photometric analysis of count rates finds that the instrument is performing at the theoretical limit.

3.
J Synchrotron Radiat ; 19(Pt 2): 245-51, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22338686

RESUMEN

Core-shell X-ray emission spectroscopy (XES) is a valuable complement to X-ray absorption spectroscopy (XAS) techniques. However, XES in the hard X-ray regime is much less frequently employed than XAS, often as a consequence of the relative scarcity of XES instrumentation having energy resolutions comparable with the relevant core-hole lifetimes. To address this, a family of inexpensive and easily operated short-working-distance X-ray emission spectrometers has been developed. The use of computer-aided design and rapid prototype machining of plastics allows customization for various emission lines having energies from ∼3 keV to ∼10 keV. The specific instrument described here, based on a coarsely diced approximant of the Johansson optic, is intended to study volume collapse in Pr metal and compounds by observing the pressure dependence of the Pr Lα emission spectrum. The collection solid angle is ∼50 msr, roughly equivalent to that of six traditional spherically bent crystal analyzers. The miniature X-ray emission spectrometer (miniXES) methodology will help encourage the adoption and broad application of high-resolution XES capabilities at hard X-ray synchrotron facilities.

4.
Phys Rev Lett ; 94(4): 047401, 2005 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-15783593

RESUMEN

Optical second-harmonic generation (SHG) is used as a noninvasive probe of the interfaces of Si nanocrystals (NCs) embedded uniformly in an SiO2 matrix. Measurements of the generated SH mode verify that the second-harmonic polarization has a nonlocal dipole form proportional to (E x Delta inverted) E that depends on inhomogeneities in the incident field E, as proposed in recent models based on a locally noncentrosymmetric dipolar response averaged over the spherical NC interfaces. A two-beam SHG geometry is found to enhance this polarization greatly compared to single-beam SHG, yielding strong signals useful for scanning, spectroscopy, and real-time monitoring. This configuration provides a general strategy for enhancing the second-order nonlinear response of centrosymmetric samples, as demonstrated here for both Si nanocomposites and their glass substrates.

6.
Accid Anal Prev ; 25(6): 675-87, 1993 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-8297436

RESUMEN

The Automobile Technique Research Association at Frankfurt, the Institute for Forensic Medicine at Mainz, the Federal Highway Research Institute at Bergisch-Gladbach, the German Motor Vehicle Inspection Association at Stuttgart, and the German Worker's Compensation at St. Augustin have completed a joint research project dealing with injury costs due to automobile accidents. The data for this social cost analysis were based on costs for administrative expenses, medical treatment, rehabilitation measures, social security payment, and loss of income, which were all paid by Worker's Compensation for single, well-documented injuries to the working population in West Germany (15 to 65 years old). The data base used included 15,407 injured and 1,026 fatal road accident victims. Tables are presented which show the costs associated with various injury levels. The result is an injury cost scale (ICS) that might be a base for establishing priorities of safety measures. The ICS has to be seen as supplemental to the AIS.


Asunto(s)
Accidentes de Tránsito/estadística & datos numéricos , Índices de Gravedad del Trauma , Heridas y Lesiones/economía , Accidentes de Tránsito/economía , Adolescente , Adulto , Anciano , Costo de Enfermedad , Alemania Occidental , Humanos , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA