Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Perfusion ; 26 Suppl 1: 35-9, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21933820

RESUMEN

This review on the benefits of pulsatile flow includes not only experimental and clinical data, but also attempts to further illuminate the major factors as to why this debate has continued during the past 55 years. Every single component of the cardiopulmonary bypass (CPB) circuitry is equally important for generating adequate quality of pulsatility, not only the pump. Therefore, translational research is a necessity to select the best components for the circuit. Generation of pulsatile flow depends on an energy gradient; precise quantification in terms of hemodynamic energy levels is, therefore, a necessity, not an option. Comparisons between perfusion modes should be done after these basic steps have been taken. We have also included experimental and clinical data for direct comparisons between the perfusion modes. In addition, we included several suggestions for future clinical trials for other interested investigators.


Asunto(s)
Puente Cardiopulmonar/métodos , Hemodinámica , Flujo Pulsátil , Adolescente , Puente Cardiopulmonar/efectos adversos , Niño , Preescolar , Femenino , Humanos , Lactante , Masculino , Investigación Biomédica Traslacional/métodos
2.
Perfusion ; 24(2): 75-9, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19654146

RESUMEN

A 24-year-old female developed heart failure within four months of delivering her first child. Echocardiogram revealed a moderately dilated left ventricle with severely reduced systolic function. She continued to decompensate, requiring intubation and inotropic support. When the use of an intra-aortic balloon pump failed to stabilize the patient, the decision was made to place her on ECMO. The circuit consisted of a Quadrox D membrane oxygenator and a CentriMag centrifugal pump. After 11 days of support, the patient met the weaning criteria and was successfully removed from ECMO. She was discharged one month after her admission. The new technology available allows for ECMO to be considered as an earlier option for the treatment and management of these patients as a bridge to recovery.


Asunto(s)
Cardiomiopatía Dilatada/terapia , Oxigenación por Membrana Extracorpórea/métodos , Insuficiencia Cardíaca/terapia , Trastornos Puerperales/terapia , Disfunción Ventricular Izquierda/terapia , Femenino , Corazón Auxiliar , Humanos , Oxigenadores de Membrana , Adulto Joven
3.
Perfusion ; 15(2): 155-9, 2000 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-10789571

RESUMEN

Surgery for the repair of a type I aortic dissection presents several difficulties for the surgeon and the perfusionist. One must safely support the patient, while at the same time provide the surgeon with a bloodless field in which to operate. Often, this requires cessation of the circulation for varying amounts of time. Deep hypothermia allows for an extension of the arrest period, while other techniques-- retrograde cerebral perfusion and antegrade cerebral perfusion--provide an additional degree of cerebral protection. Recently, we utilized these techniques concurrently on a 43-year-old female who presented for a reoperation for a type I aortic dissection. Combining these techniques allowed us to adequately support the patient during an anticipated lengthy period of circulatory arrest and insured a successful operation without any adverse cerebral or other organ dysfunction.


Asunto(s)
Aneurisma de la Aorta/cirugía , Disección Aórtica/cirugía , Puente Cardiopulmonar/instrumentación , Paro Cardíaco Inducido , Hipotermia Inducida , Adulto , Disección Aórtica/complicaciones , Aneurisma de la Aorta/complicaciones , Implantación de Prótesis Vascular , Circulación Cerebrovascular , Trastornos Relacionados con Cocaína/complicaciones , Diseño de Equipo , Femenino , Defectos del Tabique Interatrial/complicaciones , Defectos del Tabique Interatrial/cirugía , Humanos , Hipertensión/inducido químicamente , Hipertensión/complicaciones , Infarto de la Arteria Cerebral Media/complicaciones , Reoperación
4.
Perfusion ; 13(3): 176-80, 1998 May.
Artículo en Inglés | MEDLINE | ID: mdl-9638714

RESUMEN

Ultrafiltration has been shown to affect cardiac drug concentrations during cardiopulmonary bypass (CPB), based on their respective pharmacological properties. In an attempt to understand the aetiology of sternal wound infections, a study was performed to eliminate the use of ultrafiltration as a possible cause. We compared cefazolin levels at three time intervals during the course of routine CPB with ultrafiltration to those levels in a control group in which ultrafiltration was not used. Our results indicate that there is little difference in the rate of decay of antibiotic levels with or without the use of a haemoconcentrator. This implies that ultrafiltration procedures do not put the patient at any increased risk for infection and that additional measures beyond that which we would normally use at our institution need not be taken.


Asunto(s)
Puente Cardiopulmonar , Cefazolina/sangre , Cefalosporinas/sangre , Hemofiltración/efectos adversos , Medicación Preanestésica , Infección de la Herida Quirúrgica/etiología , Proteínas Sanguíneas/metabolismo , Cefazolina/farmacocinética , Cefazolina/uso terapéutico , Cefalosporinas/farmacocinética , Cefalosporinas/uso terapéutico , Semivida , Humanos , Periodo Intraoperatorio , Unión Proteica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...