Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Acta Anaesthesiol Scand ; 64(1): 63-68, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31506920

RESUMEN

BACKGROUND: Feed and swaddle is a technique in which an infant is fed and allowed to fall asleep to facilitate diagnostic imaging. This study reviews our experience and diagnostic success in premature and term infants up to 6 months old undergoing brain magnetic resonance imaging (MRI) using a feed and swaddle technique and with comparable patients imaged under anesthesia. METHODS: We reviewed the charts of all infants ≤6 months who underwent brain MRI at our institution between 1 January 2013 and 31 March 2016. We recorded and analyzed demographic information, scan indication, scan length, prematurity status, anesthetic technique if used, complications, and diagnostic success or failure. RESULTS: One hundred and sixty-four term infants underwent brain MRI using a feed and swaddle technique. The success rate in term infants <90 days was 91.1% (113/124) versus 95.0% (38/40) in infants ≥90 days and ≤181 days old. Fifty-three premature infants underwent feed and swaddle for brain MRI with a diagnostic success rate of 92.5% (49/53). No complications were noted in any feed and swaddle patients. Those who received anesthesia had a diagnostic success rate of 100% (70/70) but experienced complications including hypoxemia, 14.3% (10/70); hypothermia, 18.9% (10/53); bradycardia, 10.1% (7/69); and hypotension, 4.2% (3/70). CONCLUSION: Given the high rate of success and absence of complications with feed and swaddle in children ≤6 months for brain MRI and the presence of anesthesia-related complications, most infants should undergo a trial of feed and swaddle prior to undergoing brain MRI with anesthesia.


Asunto(s)
Encéfalo/diagnóstico por imagen , Conducta Alimentaria/fisiología , Imagen por Resonancia Magnética/métodos , Restricción Física/métodos , Sueño/fisiología , Factores de Edad , Ropa de Cama y Ropa Blanca , Femenino , Humanos , Lactante , Fórmulas Infantiles , Recién Nacido , Masculino , Leche Humana , Estudios Retrospectivos
2.
Anesthesiology ; 131(4): 801-808, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31343462

RESUMEN

BACKGROUND: Practice patterns surrounding awake extubation of pediatric surgical patients remain largely undocumented. This study assessed the value of commonly used predictors of fitness for extubation to determine which were most salient in predicting successful extubation following emergence from general anesthesia with a volatile anesthetic in young children. METHODS: This prospective, observational study was performed in 600 children from 0 to 7 yr of age. The presence or absence of nine commonly used extubation criteria in children were recorded at the time of extubation including: facial grimace, eye opening, low end-tidal anesthetic concentration, spontaneous tidal volume greater than 5 ml/kg, conjugate gaze, purposeful movement, movement other than coughing, laryngeal stimulation test, and oxygen saturation. Extubations were graded as Successful, Intervention Required, or Major Intervention Required using a standard set of criteria. The Intervention Required and Major Intervention Required outcomes were combined as a single outcome for analysis of predictors of success. RESULTS: Successful extubation occurred in 92.7% (556 of 600) of cases. Facial grimace odds ratio, 1.93 (95% CI, 1.03 to 3.60; P = 0.039), purposeful movement odds ratio, 2.42 (95% CI, 1.14 to 5.12; P = 0.022), conjugate gaze odds ratio, 2.10 (95% CI, 1.14 to 4.01; P = 0.031), eye opening odds ratio, 4.44 (95% CI, 1.06 to 18.64; P= 0.042), and tidal volume greater than 5 ml/kg odds ratio, 2.66 (95% CI, 1.21 to 5.86; P = 0.015) were univariately associated with the Successful group. A stepwise increase in any one, in any order, of these five predictors being present, from one out of five and up to five out of five yielded an increasing positive predictive value for successful extubation of 88.3% (95% CI, 82.4 to 94.3), 88.4% (95% CI, 83.5 to 93.3), 96.3% (95% CI, 93.4 to 99.2), 97.4% (95% CI, 94.4 to 100), and 100% (95% CI, 90 to 100). CONCLUSIONS: Conjugate gaze, facial grimace, eye opening, purposeful movement, and tidal volume greater than 5 ml/kg were each individually associated with extubation success in pediatric surgical patients after volatile anesthetic. Further, the use of a multifactorial approach using these predictors, may lead to a more rational and robust approach to successful awake extubation.


Asunto(s)
Extubación Traqueal/métodos , Toma de Decisiones Clínicas/métodos , Vigilia , Niño , Preescolar , Humanos , Lactante , Guías de Práctica Clínica como Asunto , Estudios Prospectivos
3.
J Clin Anesth ; 55: 20-23, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30586662

RESUMEN

STUDY OBJECTIVE: To determine whether microbial contamination of anesthesia syringes prepared in the operating room (OR) become contaminated in a time-dependent fashion. DESIGN: Observational. SETTING: Operating suite in a major university hospital. PATIENTS: None (in vitro study). 400 syringes were studied for microbial contamination. INTERVENTIONS: Syringes prepared in the OR by anesthesia personnel were sampled at 1, 2, 3, or 4 h in a sterile fashion and sent to the microbiology laboratory for quantitative culture of any bacteria. MEASUREMENTS: Colony forming units (CFU) per mL of drug were calculated and any identified positive cultures were identified by Matrix-Assisted Laser Desorption/Ionization Time of Flight Mass Spectrometry. Logistic regression was used to test the effect of time since preparation on prevalence of positive culture, as was the effect of number of accesses of the syringe and identity of the drug. MAIN RESULTS: Overall, 9/400 (2.25%) syringes were positive for bacteria. The median (interquartile range [IQR]) concentration of bacteria among positive cultures was 100 (100,100) CFU. All cultured species were generally nonpathogenic common contaminants. There was no effect of time since preparation, number of accesses of the syringe at the time of sampling, or drug identity (propofol vs. other). CONCLUSIONS: Contamination of anesthesia syringes is uncommon and occurs at a low overall concentration of bacteria. Contamination does not appear to be time related, and thus calls into question the reasonableness of USP Chapter 797's one-hour requirement.


Asunto(s)
Anestésicos/normas , Bacterias/aislamiento & purificación , Contaminación de Medicamentos/estadística & datos numéricos , Quirófanos/estadística & datos numéricos , Jeringas/microbiología , Contaminación de Medicamentos/prevención & control , Embalaje de Medicamentos/normas , Humanos , Quirófanos/normas , Guías de Práctica Clínica como Asunto , Jeringas/normas , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...