1.
Eur J Heart Fail ; 26(8): 1814-1823, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38899626

RESUMEN

AIMS: Haemodynamic monitoring using implantable pressure sensors reduces the risk of heart failure (HF) hospitalizations. Patient self-management (PSM) of haemodynamics in HF has the potential to personalize treatment, increase adherence, and reduce the risk of worsening HF, while lowering clinicians' burden. METHODS AND RESULTS: The VECTOR-HF I and IIa studies are prospective, single-arm, open-label clinical trials assessing safety, usability and performance of left atrial pressure (LAP)-guided HF management using PSM in New York Heart Association class II and III HF patients. Physician-prescribed LAP thresholds trigger patient self-adjustment of diuretics. Primary endpoints include the ability to perform LAP measurements and transmit data to the healthcare provider (HCP) interface and the patient guidance application, and safety outcomes. This is an interim analysis of 13 patients using the PSM approach. Over 12 months, no procedure- or device-related major adverse cardiovascular or neurological events were observed, and there were no failures to obtain measurements from the sensor and transmit the data to the HCP interface and the patient guidance application. Patient adherence was 91.4%. Using PSM, annualized HF hospitalization rate significantly decreased compared to a similar period prior to PSM utilization (0 admissions vs. 0.69 admissions over 11.84 months, p = 0.004). At 6 months, 6-min walk test distance and the Kansas City Cardiomyopathy Questionnaire overall summary score demonstrated significant improvement. CONCLUSIONS: Interim findings suggest that PSM using a LAP monitoring system is feasible and safe. PSM is associated with high patient adherence, potentially improving HF patients' functional status, quality of life, and limiting HF hospitalizations.


Asunto(s)
Presión Atrial , Insuficiencia Cardíaca , Automanejo , Humanos , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/fisiopatología , Masculino , Femenino , Anciano , Estudios Prospectivos , Automanejo/métodos , Presión Atrial/fisiología , Persona de Mediana Edad , Hospitalización/estadística & datos numéricos
3.
Can J Cardiol ; 39(12): 1957-1958, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37716643
4.
Eur J Heart Fail ; 25(6): 902-911, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37092287

RESUMEN

AIMS: In heart failure (HF), implantable haemodynamic monitoring devices have been shown to optimize therapy, anticipating clinical decompensation and preventing hospitalization. Direct left-sided haemodynamic sensors offer theoretical benefits beyond pulmonary artery pressure monitoring systems. We evaluated the safety, usability, and performance of a novel left atrial pressure (LAP) monitoring system in HF patients. METHODS AND RESULTS: The VECTOR-HF study (NCT03775161) was a first-in-human, prospective, multicentre, single-arm, clinical trial enrolling 30 patients with HF. The device consisted of an interatrial positioned leadless sensor, able to transmit LAP data wirelessly. After 3 months, a right heart catheterization was performed to correlate mean pulmonary capillary wedge pressure (PCWP) with simultaneous mean LAP obtained from the device. Remote LAP measurements were then used to guide patient management. The miniaturized device was successfully implanted in all 30 patients, without acute major adverse cardiac and neurological events (MACNE). At 3 months, freedom from short-term MACNE was 97%. Agreement between sensor-calculated LAP and PCWP was consistent, with a mean difference of -0.22 ± 4.92 mmHg, the correlation coefficient and the Lin's concordance correlation coefficient values were equal to 0.79 (p < 0.0001) and 0.776 (95% confidence interval 0.582-0.886), respectively. Preliminary experience with V-LAP-based HF management was associated with significant improvements in New York Heart Association (NYHA) functional class (32% of patients reached NYHA class II at 6 months, p < 0.005; 60% of patients at 12 months, p < 0.005) and 6-min walk test distance (from 244.59 ± 119.59 m at baseline to 311.78 ± 129.88 m after 6 months, p < 0.05, and 343.95 ± 146.15 m after 12 months, p < 0.05). CONCLUSION: The V-LAP™ monitoring system proved to be generally safe and provided a good correlation with invasive PCWP. Initial evidence also suggests possible improvement in HF clinical symptoms.


Asunto(s)
Presión Atrial , Insuficiencia Cardíaca , Humanos , Cateterismo Cardíaco/métodos , Estudios Prospectivos , Presión Esfenoidal Pulmonar
5.
J Card Fail ; 28(6): 963-972, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35041933

RESUMEN

OBJECTIVE: Patients with heart failure (HF) are at an increased risk of hospital admissions. The aim of this report is to describe the feasibility, safety and accuracy of a novel wireless left atrial pressure (LAP) monitoring system in patients with HF. METHODS: The V-LAP Left Atrium Monitoring systEm for Patients With Chronic sysTOlic & Diastolic Congestive heart Failure (VECTOR-HF) study is a prospective, multicenter, single-arm, open-label, first-in human clinical trial to assess the safety, performance and usability of the V-LAP system (Vectorious Medical Technologies) in patients with New York Heart Association class III HF. The device was implanted in the interatrial septum via a percutaneous, trans-septal approach guided by fluoroscopy and echocardiography. Primary endpoints included the successful deployment of the implant, the ability to perform initial pressure measurements and safety outcomes. RESULTS: To date, 24 patients have received implants of the LAP-monitoring device. No device-related complications have occurred. LAP was reported accurately, agreeing well with wedge pressure at 3 months (Lin concordance correlation coefficient = 0.850). After 6 months, New York Heart Association class improved in 40% of the patients (95% CI = 16.4%-63.5%), while the 6-minute walk test distance had not changed significantly (313.9 ± 144.9 vs 232.5 ± 129.9 meters; P = 0.076). CONCLUSION: The V-LAP left atrium monitoring system appears to be safe and accurate.


Asunto(s)
Presión Atrial , Insuficiencia Cardíaca , Cateterismo Cardíaco , Humanos , Estudios Prospectivos , Volumen Sistólico
6.
J Cardiovasc Transl Res ; 15(1): 61-66, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34075553

RESUMEN

There is an important need to develop a transcatheter/trans-septal-like model which will allow deliverability of mitral valve devices at the right angulation and height above the mitral annulus similar to the human patient. A ministernotomy allowing for TEE probe to be introduced transpericardially was performed in seven animals. In three, a standard trans-septal approach was used to attempt to deliver a device to the level of the mitral plane with a human delivery system. In four cases, a Dacron tube was connected to the RPV and the device introduced to the LA. Under TEE equivalent imaging, the device was then successfully steered to the mitral plane in all cases, having failed in all trans-septal attempts. A combination of transpericardial echocardiographic imaging (TPE) and RPV approach to the LA facilitated successful human-like mitral valve device implantation.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Venas Pulmonares , Animales , Cateterismo Cardíaco , Ecocardiografía Transesofágica , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Venas Pulmonares/cirugía , Porcinos
7.
J Cardiovasc Transl Res ; 15(1): 84-94, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34115322

RESUMEN

High-frequency QRS (HFQRS) analysis of surface ECG is a reliable marker of cardiac ischemia (CI). This study aimed to assess the response of HFQRS signals from standard intracardiac electrodes (iHFQRS) to CI in swine and compare them with conventional ST-segment deviations. Devices with three intracardiac leads were implanted in three swine in a controlled environment. CI was induced by inflating a balloon in epicardial coronary arteries. A designated signal-processing algorithm was applied to quantify the iHFQRS content before, during, and after each occlusion. iHFQRS time responses were compared to conventional ST-segment deviations. Thirty-three over thirty-nine (85%) of the occlusions presented significant reduction in the iHFQRS signal, preceding ST-segment change, being the only indicator of CI in brief occlusions. iHFQRS was found to be an early indicator for the onset of CI and demonstrated superior sensitivity to conventional ST-segment deviations during brief ischemic episodes.


Asunto(s)
Enfermedad de la Arteria Coronaria , Isquemia Miocárdica , Animales , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Isquemia , Isquemia Miocárdica/diagnóstico , Porcinos
10.
Can J Cardiol ; 37(7): 1027-1040, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33753201

RESUMEN

Mitral regurgitation (MR) is a common condition causing significant morbidity and mortality in the Western world. Although surgical therapy has developed over 5 decades to provide solutions, only a minority of patients undergo surgery. The last decade has seen the emergence and application of multiple transcatheter techniques in attempts to address this undertreated population with the large clinical experience of MitraClip providing the most insight. Clear understanding of the pathophysiology of different MR types as well as the role of particularly secondary MR on patient's clinical syndrome allow for better prediction as to which patient subgroups will benefit from different repair techniques or intervention at all. Most of the techniques are based on surgical technique and are applied as single-device/technique solutions, whether leaflet, chordal, or annular solutions, but with broadening experience, combination therapies are likely to find a place in creating a more complete and surgical-like solution.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/métodos , Terapia Combinada/métodos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/terapia