Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Magy Seb ; 60(2): 99-102, 2007 Apr.
Artículo en Húngaro | MEDLINE | ID: mdl-17649852

RESUMEN

UNLABELLED: Gastro-entero anastomosis with flexible endoscope with the help of rare-earth magnets on biosynthetic model made of the gastrointestinal tract of slaughtered pigs BACKGROUND: Numerous malignant diseases may cause gastric outlet obstruction. The surgical gastrointestinal bypass, besides the fact that it requires narcosis, is also associated with high risks for patients with poor general condition. Endoscopic insertion of self-expandable metal stent is less invasive, but often causes complications. In the last years some studies examined a new minimal invasive technique, in which magnets are used to create gastroenteric anastomosis. MATERIAL AND METHOD: A biosynthetic model was developed from combined synthetic materials with biogenic specimens taken from slaughtered domestic pigs. The procedure was performed with endoscopic and fluoroscopic guidance. To increase X-ray contrast differences the model was put into physiological saline solution. Two rare-earth magnets (Br: 2500 Gauss, D: 10 mm) with central hole were inserted with the help of a guiding wire and duodenal probe. The first magnet was placed in the first jejunal loop; the second one was placed in the stomach. The gastric magnet was maneuvered using the endoscope. When the magnets reached the right position, the guiding wires were removed to let the magnets stick together. The pressure between the magnets will result in a sterile inflammation on the living tissue which develops adhesion between the bowels, and 7-10 days later anastomosis will develop as a result of the necrosis. RESULT: The biosynthetic model could be used for training endoscopy without sacrificing animals. In the end of the procedure the magnets stuck together across gastric and jejunal walls in all ten cases successfully. By practice the period necessary for the procedure could be decreased from 40 to 20 minutes. CONCLUSION: The technique could be made with standard upper endoscope and instruments, and after practice on living animals it could potentially be a useful solution for complaints of gastric outlet obstruction.


Asunto(s)
Endoscopía Gastrointestinal , Obstrucción de la Salida Gástrica/cirugía , Intestinos/cirugía , Magnetismo , Estómago/cirugía , Anastomosis Quirúrgica , Animales , Modelos Animales de Enfermedad , Diseño de Equipo , Fluoroscopía , Obstrucción de la Salida Gástrica/etiología , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA