Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 97
Filtrar
1.
Bayesian Anal ; 19(2): 623-647, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-39183822

RESUMEN

Current protocols to estimate the number, size, and location of cancerous lesions in the prostate using multiparametric magnetic resonance imaging (mpMRI) are highly dependent on reader experience and expertise. Automatic voxel-wise cancer classifiers do not directly provide estimates of number, location, and size of cancerous lesions that are clinically important. Existing spatial partitioning methods estimate linear or piecewise-linear boundaries separating regions of local stationarity in spatially registered data and are inadequate for the application of lesion detection. Frequentist segmentation and clustering methods often require pre-specification of the number of clusters and do not quantify uncertainty. Previously, we developed a novel Bayesian functional spatial partitioning method to estimate the boundary surrounding a single cancerous lesion using data derived from mpMRI. We propose a Bayesian functional spatial partitioning method for multiple lesion detection with an unknown number of lesions. Our method utilizes functional estimation to model the smooth boundary curves surrounding each cancerous lesion. In a Reversible Jump Markov Chain Monte Carlo (RJ-MCMC) framework, we develop novel jump steps to jointly estimate and quantify uncertainty in the number of lesions, their boundaries, and the spatial parameters in each lesion. Through simulation we show that our method is robust to the shape of the lesions, number of lesions, and region-specific spatial processes. We illustrate our method through the detection of prostate cancer lesions using MRI.

2.
NMR Biomed ; : e5228, 2024 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-39169274

RESUMEN

Quantitative maps of rotating frame relaxation (RFR) time constants are sensitive and useful magnetic resonance imaging tools with which to evaluate tissue integrity in vivo. However, to date, only moderate image resolutions of 1.6 x 1.6 x 3.6 mm3 have been used for whole-brain coverage RFR mapping in humans at 3 T. For more precise morphometrical examinations, higher spatial resolutions are desirable. Towards achieving the long-term goal of increasing the spatial resolution of RFR mapping without increasing scan times, we explore the use of the recently introduced Transform domain NOise Reduction with DIstribution Corrected principal component analysis (T-NORDIC) algorithm for thermal noise reduction. RFR acquisitions at 3 T were obtained from eight healthy participants (seven males and one female) aged 52 ± 20 years, including adiabatic T1ρ, T2ρ, and nonadiabatic Relaxation Along a Fictitious Field (RAFF) in the rotating frame of rank n = 4 (RAFF4) with both 1.6 x 1.6 x 3.6 mm3 and 1.25 x 1.25 x 2 mm3 image resolutions. We compared RFR values and their confidence intervals (CIs) obtained from fitting the denoised versus nondenoised images, at both voxel and regional levels separately for each resolution and RFR metric. The comparison of metrics obtained from denoised versus nondenoised images was performed with a two-sample paired t-test and statistical significance was set at p less than 0.05 after Bonferroni correction for multiple comparisons. The use of T-NORDIC on the RFR images prior to the fitting procedure decreases the uncertainty of parameter estimation (lower CIs) at both spatial resolutions. The effect was particularly prominent at high-spatial resolution for RAFF4. Moreover, T-NORDIC did not degrade map quality, and it had minimal impact on the RFR values. Denoising RFR images with T-NORDIC improves parameter estimation while preserving the image quality and accuracy of all RFR maps, ultimately enabling high-resolution RFR mapping in scan times that are suitable for clinical settings.

3.
MAGMA ; 2024 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-39042205

RESUMEN

OBJECTIVE: Quantitative parameter mapping conventionally relies on curve fitting techniques to estimate parameters from magnetic resonance image series. This study compares conventional curve fitting techniques to methods using neural networks (NN) for measuring T2 in the prostate. MATERIALS AND METHODS: Large physics-based synthetic datasets simulating T2 mapping acquisitions were generated for training NNs and for quantitative performance comparisons. Four combinations of different NN architectures and training corpora were implemented and compared with four different curve fitting strategies. All methods were compared quantitatively using synthetic data with known ground truth, and further compared on in vivo test data, with and without noise augmentation, to evaluate feasibility and noise robustness. RESULTS: In the evaluation on synthetic data, a convolutional neural network (CNN), trained in a supervised fashion using synthetic data generated from naturalistic images, showed the highest overall accuracy and precision amongst the methods. On in vivo data, this best performing method produced low-noise T2 maps and showed the least deterioration with increasing input noise levels. DISCUSSION: This study showed that a CNN, trained with synthetic data in a supervised manner, may provide superior T2 estimation performance compared to conventional curve fitting, especially in low signal-to-noise regions.

4.
bioRxiv ; 2024 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-38826245

RESUMEN

Purpose: To develop multichannel transmit and receive arrays towards capturing the ultimate-intrinsic-SNR (uiSNR) at 10.5 Tesla (T) and to demonstrate the feasibility and potential of whole-brain, high-resolution human brain imaging at this high field strength. Methods: A dual row 16-channel self-decoupled transmit (Tx) array was converted to a 16Tx/Rx transceiver using custom transmit/receive switches. A 64-channel receive-only (64Rx) array was built to fit into the 16Tx/Rx array. Electromagnetic modeling and experiments were employed to define safe operation limits of the resulting 16Tx/80Rx array and obtain FDA approval for human use. Results: The 64Rx array alone captured approximately 50% of the central uiSNR at 10.5T while the identical 7T 64Rx array captured ∼76% of uiSNR at this lower field strength. The 16Tx/80Rx configuration brought the fraction of uiSNR captured at 10.5T to levels comparable to the performance of the 64Rx array at 7T. SNR data obtained at the two field strengths with these arrays displayed dependent increases over a large central region. Whole-brain high resolution T 2 * and T 1 weighted anatomical and gradient-recalled echo EPI BOLD fMRI images were obtained at 10.5T for the first time with such an advanced array, illustrating the promise of >10T fields in studying the human brain. Conclusion: We demonstrated the ability to approach the uiSNR at 10.5T over the human brain with a novel, high channel count array, achieving large SNR gains over 7T, currently the most commonly employed ultrahigh field platform, and demonstrate high resolution and high contrast anatomical and functional imaging at 10.5T.

5.
Magn Reson Med ; 92(1): 43-56, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38303151

RESUMEN

PURPOSE: To introduce universal modes by applying the universal pulse concept to time-interleaved acquisition of modes (TIAMO), thereby achieving calibration-free B 1 + $$ {B}_1^{+} $$ inhomogeneity mitigation for body imaging at ultra-high fields. METHODS: Two databases of different RF arrays were used to demonstrate the feasibility of universal modes. The first comprised 31 cardiac in vivo data sets acquired at 7T while the second consisted of 6 simulated 10.5T pelvic data sets. Subject-specific solutions and universal modes were computed and subsequently evaluated alongside predefined default modes. For the cardiac database, subdivision into subpopulations was investigated. The optimization was performed using least-squares (LS) TIAMO and acquisition modes optimized for refocused echoes (AMORE). Finally, universal modes based on simulated pelvis data were applied in vivo at 10.5T. RESULTS: In all studied cases, the universal modes yield improvements over the predefined default modes of up to 51% (cardiac) and 30% (pelvic) in terms of median excitation error when using two modes. The subpopulation-specific cardiac solutions revealed a further improvement of universal modes at the expense of increased errors when applied outside the appropriate subpopulation. Direct application of simulation-based universal modes in vivo resulted in up to a 14% reduction in excitation error compared to default modes and up to a 34% reduction in peak 10 g local specific absorption rate (SAR) compared to subject-specific solutions. CONCLUSIONS: Universal modes are feasible for calibration-free B 1 + $$ {B}_1^{+} $$ inhomogeneity mitigation at ultra-high fields. In addition, simulation-based solutions can be applied directly in vivo, eliminating the need for large in vivo databases.


Asunto(s)
Algoritmos , Corazón , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Pelvis , Humanos , Corazón/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Pelvis/diagnóstico por imagen , Calibración , Masculino , Adulto , Simulación por Computador , Fantasmas de Imagen , Femenino , Análisis de los Mínimos Cuadrados , Bases de Datos Factuales
6.
Magn Reson Med ; 91(3): 1099-1114, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37997011

RESUMEN

PURPOSE: To evaluate the influence of skeletal maturation on sodium (23 Na) MRI relaxation parameters and the accuracy of tissue sodium concentration (TSC) quantification in human knee cartilage. METHODS: Twelve pediatric knee specimens were imaged with whole-body 10.5 T MRI using a density-adapted 3D radial projection sequence to evaluate 23 Na parameters: B1 + , T1 , biexponential T 2 * $$ {\mathrm{T}}_2^{\ast } $$ , and TSC. Water, collagen, and sulfated glycosaminoglycan (sGAG) content were calculated from osteochondral biopsies. The TSC was corrected for B1 + , relaxation, and water content. The literature-based TSC (TSCLB ) used previously published values for corrections, whereas the specimen-specific TSC (TSCSP ) used measurements from individual specimens. 23 Na parameters were evaluated in eight cartilage compartments segmented on proton images. Associations between 23 Na parameters, TSCLB - TSCSP difference, biochemical content, and age were determined. RESULTS: From birth to 12 years, cartilage water content decreased by 18%; collagen increased by 59%; and sGAG decreased by 36% (all R2 ≥ 0.557). The short T 2 * $$ {\mathrm{T}}_2^{\ast } $$ ( T 2 * S $$ {{\mathrm{T}}_2^{\ast}}_{\mathrm{S}} $$ ) decreased by 72%, and the signal fraction relaxing with T 2 * S $$ {{\mathrm{T}}_2^{\ast}}_{\mathrm{S}} $$ ( fT 2 * S $$ {{\mathrm{fT}}_2^{\ast}}_{\mathrm{S}} $$ ) increased by 55% during the first 5 years but remained relatively stable after that. TSCSP was significantly correlated with sGAG content from biopsies (R2 = 0.739). Depending on age, TSCLB showed higher or lower values than TSCSP . The TSCLB - TSCSP difference was significantly correlated with T 2 * S $$ {{\mathrm{T}}_2^{\ast}}_{\mathrm{S}} $$ (R2 = 0.850), fT 2 * S $$ {{\mathrm{fT}}_2^{\ast}}_{\mathrm{S}} $$ (R2 = 0.651), and water content (R2 = 0.738). CONCLUSION: TSC and relaxation parameters measured with 23 Na MRI provide noninvasive information about changes in sGAG content and collagen matrix during cartilage maturation. Cartilage TSC quantification assuming fixed relaxation may be feasible in children older than 5 years.


Asunto(s)
Cartílago Articular , Cartílago , Humanos , Niño , Preescolar , Imagen por Resonancia Magnética/métodos , Sodio , Colágeno , Agua , Cartílago Articular/diagnóstico por imagen
7.
Magn Reson Med ; 91(2): 513-529, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37705412

RESUMEN

PURPOSE: To increase the RF coil performance and RF management for body imaging at 10.5 T by validating and evaluating a high-density 16-channel transceiver array, implementing virtual observation points (VOPs), and demonstrating specific absorption rate (SAR) constrained imaging in vivo. METHODS: The inaccuracy of the electromagnetic model of the array was quantified based on B1 + and SAR data. Inter-subject variability was estimated using a new approach based on the relative SAR deviation of different RF shims between human body models. The pTx performance of the 16-channel array was assessed in simulation by comparison to a previously demonstrated 10-channel array. In vivo imaging of the prostate was performed demonstrating SAR-constrained static RF shimming and acquisition modes optimized for refocused echoes (AMORE). RESULTS: The model inaccuracy of 29% and the inter-subject variability of 85% resulted in a total safety factor of 1.91 for pelvis studies. For renal and cardiac imaging, inter-subject variabilities of 121% and 141% lead to total safety factors of 2.25 and 2.45, respectively. The shorter wavelength at 10.5 T supported the increased element density of the 16-channel array which in turn outperformed the 10-channel version for all investigated metrics. Peak 10 g local SAR reduction of more than 25% without a loss of image quality was achieved in vivo, allowing a theoretical improvement in measurement efficiency of up to 66%. CONCLUSIONS: By validating and characterizing a 16-channel dipole transceiver array, this work demonstrates, for the first time, a VOP-enabled RF coil for human torso imaging enabling increased pTx performance at 10.5 T.


Asunto(s)
Imagen por Resonancia Magnética , Próstata , Masculino , Humanos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Diseño de Equipo , Simulación por Computador , Ondas de Radio
8.
AJR Am J Roentgenol ; 221(6): 788-804, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37377363

RESUMEN

The first commercially available 7-T MRI scanner (Magnetom Terra) was approved by the FDA in 2017 for clinical imaging of the brain and knee. After initial protocol development and sequence optimization efforts in volunteers, the 7-T system, in combination with an FDA-approved 1-channel transmit/32-channel receive array head coil, can now be routinely used for clinical brain MRI examinations. The ultrahigh field strength of 7-T MRI has the advantages of improved spatial resolution, increased SNR, and increased CNR but also introduces an array of new technical challenges. The purpose of this article is to describe an institutional experience with the use of the commercially available 7-T MRI scanner for routine clinical brain imaging. Specific clinical indications for which 7-T MRI may be useful for brain imaging include brain tumor evaluation with possible perfusion imaging and/or spectroscopy, radiotherapy planning; evaluation of multiple sclerosis and other demyelinating diseases, evaluation of Parkinson disease and guidance of deep brain stimulator placement, high-detail intracranial MRA and vessel wall imaging, evaluation of pituitary pathology, and evaluation of epilepsy. Detailed protocols, including sequence parameters, for these various indications are presented, and implementation challenges (including artifacts, safety, and side effects) and potential solutions are explored.


Asunto(s)
Neoplasias Encefálicas , Epilepsia , Humanos , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Neuroimagen/métodos , Neoplasias Encefálicas/diagnóstico por imagen
9.
J Orthop ; 38: 73-78, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37008451

RESUMEN

Background: An increase in intra-muscular creatine through supplementation has been proposed as a strategy for improving muscle performance and recovery, with studies showing some benefit for adult athletes who rely on short, explosive movements. We reviewed and summarized the current literature on creatine supplementation in a pediatric and adolescent population. Methods: The databases PubMed and EMBASE were queried to identity articles related to the use of creatine supplementation in a healthy pediatric and adolescent population according to the guidelines established by PRISMA. The abstracts of all articles were reviewed to determine relevancy, with those meeting the pre-defined criteria included in the final review. Results: A combined total of 9393 articles were identified. Following application of filters and review of abstracts, 13 articles were found to meet criteria and were included in the final review. There was a total of 268 subjects across all studies, with mean age ranging from 11.5 to 18.2 years. More than 75% of the studies were randomized-controlled trials, and 85% involved either soccer players or swimmers. The overall quality of the studies was poor, and there were no consistent findings regarding creatine supplementation and improvements in athletic performance. No studies were designed to address the topic of safety. Conclusions: There is a gap in the study of the safety and efficacy of creatine supplementation in adolescents. Additional studies are needed to evaluate the effects of alterations in muscle composition on the growth, development, and performance of the developing athlete. Orthopedic providers should counsel their pediatric and adolescent patients on the current limitations in trying to assess the true risk and benefit of creatine supplementation for the aspiring athlete. Level of evidence: Review, III.

10.
J Appl Stat ; 50(3): 805-826, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36819087

RESUMEN

Multi-parametric MRI (mpMRI) is a critical tool in prostate cancer (PCa) diagnosis and management. To further advance the use of mpMRI in patient care, computer aided diagnostic methods are under continuous development for supporting/supplanting standard radiological interpretation. While voxel-wise PCa classification models are the gold standard, few if any approaches have incorporated the inherent structure of the mpMRI data, such as spatial heterogeneity and between-voxel correlation, into PCa classification. We propose a machine learning-based method to fill in this gap. Our method uses an ensemble learning approach to capture regional heterogeneity in the data, where classifiers are developed at multiple resolutions and combined using the super learner algorithm, and further account for between-voxel correlation through a Gaussian kernel smoother. It allows any type of classifier to be the base learner and can be extended to further classify PCa sub-categories. We introduce the algorithms for binary PCa classification, as well as for classifying the ordinal clinical significance of PCa for which a weighted likelihood approach is implemented to improve the detection of less prevalent cancer categories. The proposed method has shown important advantages over conventional modeling and machine learning approaches in simulations and application to our motivating patient data.

11.
medRxiv ; 2023 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-36711813

RESUMEN

This work seeks to evaluate multiple methods for quantitative parameter estimation from standard T2 mapping acquisitions in the prostate. The T2 estimation performance of methods based on neural networks (NN) was quantitatively compared to that of conventional curve fitting techniques. Large physics-based synthetic datasets simulating T2 mapping acquisitions were generated for training NNs and for quantitative performance comparisons. Ten combinations of different NN architectures, training strategies, and training corpora were implemented and compared with four different curve fitting strategies. All methods were compared quantitatively using synthetic data with known ground truth, and further compared on in vivo test data, with and without noise augmentation, to evaluate feasibility and noise robustness. In the evaluation on synthetic data, a convolutional neural network (CNN), trained in a supervised fashion using synthetic data generated from naturalistic images, showed the highest overall accuracy and precision amongst all the methods. On in vivo data, this best-performing method produced low-noise T2 maps and showed the least deterioration with increasing input noise levels. This study showed that a CNN, trained with synthetic data in a supervised manner, may provide superior T2 estimation performance compared to conventional curve fitting, especially in low signal-to-noise regions.

12.
J Orthop Res ; 41(3): 663-673, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-35716161

RESUMEN

Juvenile osteochondritis dissecans (JOCD) is a pediatric orthopedic disorder that involves the articular-epiphyseal cartilage complex and underlying bone. Clinical disease is often characterized by the presence of radiographically apparent osteochondral flaps and fragments. The existence of early JOCD lesions (osteochondrosis latens [OCL] and osteochondrosis manifesta [OCM]) that precede the development of osteochondral flaps and fragments is also well recognized. However, identification of naturally occurring OCL lesions (confined to cartilage) using noninvasive imaging techniques has not yet been accomplished. We hypothesized that 10.5 T magnetic resonance imaging (MRI) can identify naturally occurring OCL lesions at predilection sites in intact joints of juvenile pigs. Unilateral elbows and knees (stifles) were harvested from three pigs aged 4, 8, and 12 weeks, and scanned in a 10.5 T MRI to obtain morphological 3D DESS images, and quantitative T2 and T1ρ relaxation time maps. Areas with increased T2 and T1ρ relaxation times in the articular-epiphyseal cartilage complex were identified in 1/3 distal femora and 3/3 distal humeri and were considered suspicious for OCL or OCM lesions. Histological assessment confirmed the presence of OCL or OCM lesions at each of these sites and failed to identify additional lesions. Histological findings included necrotic vascular profiles associated with areas of chondronecrosis either confined to the epiphyseal cartilage (OCL, 4- and 8-week-old specimens) or resulting in a delay in endochondral ossification (OCM, 12-week-old specimen). Future studies with clinical MR systems (≤7 T) are needed to determine whether these MRI methods are suitable for the in vivo diagnosis of early JOCD lesions in humans.


Asunto(s)
Osteocondritis Disecante , Osteocondrosis , Humanos , Niño , Porcinos , Animales , Osteocondrosis/patología , Necrosis , Imagen por Resonancia Magnética , Imagenología Tridimensional
13.
Biometrics ; 79(2): 604-615, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-34806765

RESUMEN

Spatial partitioning methods correct for nonstationarity in spatially related data by partitioning the space into regions of local stationarity. Existing spatial partitioning methods can only estimate linear partitioning boundaries. This is inadequate for detecting an arbitrarily shaped anomalous spatial region within a larger area. We propose a novel Bayesian functional spatial partitioning (BFSP) algorithm, which estimates closed curves that act as partitioning boundaries around anomalous regions of data with a distinct distribution or spatial process. Our method utilizes transitions between a fixed Cartesian and moving polar coordinate system to model the smooth boundary curves using functional estimation tools. Using adaptive Metropolis-Hastings, the BFSP algorithm simultaneously estimates the partitioning boundary and the parameters of the spatial distributions within each region. Through simulation we show that our method is robust to shape of the target zone and region-specific spatial processes. We illustrate our method through the detection of prostate cancer lesions using magnetic resonance imaging.


Asunto(s)
Neoplasias de la Próstata , Masculino , Humanos , Teorema de Bayes , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Imagen por Resonancia Magnética , Algoritmos , Simulación por Computador
14.
J Orthop Res ; 41(7): 1449-1463, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36484124

RESUMEN

Current clinical MRI of patients with juvenile osteochondritis dissecans (JOCD) is limited by the low reproducibility of lesion instability evaluation and inability to predict which lesions will heal after nonoperative treatment and which will later require surgery. The aim of this study is to verify the ability of apparent diffusion coefficient (ADC) to detect differences in lesion microstructure between different JOCD stages, treatment groups, and healthy, unaffected contralateral knees. Pediatric patients with JOCD received quantitative diffusion MRI between January 2016 and September 2020 in this prospective research study. A disease stage (I-IV) and stability of each JOCD lesion was evaluated. ADCs were calculated in progeny lesion, interface, parent bone, cartilage overlying lesion, control bone, and control cartilage regions. ADC differences were evaluated using linear mixed models with Bonferroni correction. Evaluated were 30 patients (mean age, 13 years; 21 males), with 40 JOCD-affected and 12 healthy knees. Nine patients received surgical treatment after MRI. Negative Spearman rank correlations were found between ADCs and JOCD stage in the progeny lesion (ρ = -0.572; p < 0.001), interface (ρ = -0.324; p = 0.041), and parent bone (ρ = -0.610; p < 0.001), demonstrating the sensitivity of ADC to microstructural differences in lesions at different JOCD stages. We observed a significant increase in the interface ADCs (p = 0.007) between operative (mean [95% CI] = 1.79 [1.56-2.01] × 10-3 mm2 /s) and nonoperative group (1.27 [0.98-1.57] × 10-3 mm2 /s). Quantitative diffusion MRI detects microstructural differences in lesions at different stages of JOCD progression towards healing and reveals differences between patients assigned for operative versus nonoperative treatment.


Asunto(s)
Cartílago Articular , Osteocondritis Disecante , Masculino , Humanos , Niño , Adolescente , Osteocondritis Disecante/diagnóstico por imagen , Cartílago Articular/diagnóstico por imagen , Cartílago Articular/patología , Reproducibilidad de los Resultados , Estudios Prospectivos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/patología , Imagen por Resonancia Magnética , Imagen de Difusión por Resonancia Magnética
15.
NMR Biomed ; 36(5): e4874, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36368912

RESUMEN

The purpose of this work is to propose a tier-based formalism for safety assessment of custom-built radio-frequency (RF) coils that balances validation effort with the effort put in determinating the safety factor. The formalism has three tier levels. Higher tiers require increased effort when validating electromagnetic simulation results but allow for less conservative safety factors. In addition, we propose a new method to calculate modeling uncertainty between simulations and measurements and a new method to propagate uncertainties in the simulation into a safety factor that minimizes the risk of underestimating the peak specific absorption rate (SAR). The new safety assessment procedure was completed for all tier levels for an eight-channel dipole array for prostate imaging at 7 T and an eight-channel dipole array for head imaging at 10.5 T, using data from two different research sites. For the 7 T body array, the validation procedure resulted in a modeling uncertainty of 77% between measured and simulated local SAR distributions. For a situation where RF shimming is performed on the prostate, average power limits of 2.4 and 4.5 W/channel were found for tiers 2 and 3, respectively. When the worst-case peak SAR among all phase settings was calculated, power limits of 1.4 and 2.7 W/channel were found for tiers 2 and 3, respectively. For the 10.5 T head array, a modeling uncertainty of 21% was found based on B1 + mapping. For the tier 2 validation, a power limit of 2.6 W/channel was calculated. The demonstrated tier system provides a strategy for evaluating modeling inaccuracy, allowing for the rapid translation of novel coil designs with conservative safety factors and the implementation of less conservative safety factors for frequently used coil arrays at the expense of increased validation effort.


Asunto(s)
Imagen por Resonancia Magnética , Ondas de Radio , Masculino , Humanos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Simulación por Computador , Próstata/diagnóstico por imagen
16.
World J Pediatr Surg ; 5(4): e000440, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36474746

RESUMEN

Objective: With few studies investigating the effectiveness of telemedicine (TM) in pediatric otolaryngology (ear, nose, and throat; ENT), its role in clinical practice is unclear. The objective of this study was to investigate provider perspectives regarding utility of TM in pediatric ENT practice. Methods: A survey gauging the relative merits of TM visits for common pediatric ENT chief complaints and postoperative visits was distributed to all pediatric ENT providers at a tertiary care, free-standing children's hospital. Respondents were asked to assess the effectiveness of TM visits compared with in-person visits for completing the following tasks: history collection, physical examination, medical decision-making, and patient counseling. Results: Providers rated TM visits as less useful than in-person visits for completing the most predefined tasks but did identify advantages in history taking via TM for the majority of complaints. Compared with providers with ≥10 years of experience, those with <10 years of experience found TM to be more effective than the in-person appointment for making clinical decisions for patients presenting with recurrent/chronic pharyngitis, neck masses, and stridor/noisy breathing. Opinions regarding the utility of TM for postoperative visits were mixed, with adenoidectomy, tonsillectomy and superficial procedures being most frequently deemed appropriate for TM. Conclusions: The introduction of TM to pediatric ENT faces limitations in detailed examination of areas not accessible without specialized instrumentation. Due to its strength in history taking, results suggest an asynchronous, 'store and forward' encounter followed by an in-person physical examination to confirm the diagnosis and treatment plan could be beneficial.

17.
Magn Reson Med ; 88(6): 2645-2661, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35906923

RESUMEN

PURPOSE: To present electromagnetic simulation setups for detailed analyses of respiration's impact on B 1 + $$ {B}_1^{+} $$ and E-fields, local specific absorption rate (SAR) and associated safety-limits for 7T cardiac imaging. METHODS: Finite-difference time-domain electromagnetic field simulations were performed at five respiratory states using a breathing body model and a 16-element 7T body transceiver RF-coil array. B 1 + $$ {B}_1^{+} $$ and SAR are analyzed for fixed and moving coil configurations. SAR variations are investigated using phase/amplitude shimming considering (i) a local SAR-controlled mode (here SAR calculations consider RF amplitudes and phases) and (ii) a channel-wise power-controlled mode (SAR boundary calculation is independent of the channels' phases, only dependent on the channels' maximum amplitude). RESULTS: Respiration-induced variations of both B 1 + $$ {B}_1^{+} $$ amplitude and phase are observed. The flip angle homogeneity depends on the respiratory state used for B 1 + $$ {B}_1^{+} $$ shimming; best results were achieved for shimming on inhale and exhale simultaneously ( | Δ C V | < 35 % $$ \mid \Delta CV\mid <35\% $$ ). The results reflect that respiration impacts position and amplitude of the local SAR maximum. With the local-SAR-control mode, a safety factor of up to 1.4 is needed to accommodate for respiratory variations while the power control mode appears respiration-robust when the coil moves with respiration (SAR peak decrease: 9% exhale→inhale). Instead, a spatially fixed coil setup yields higher SAR variations with respiration. CONCLUSION: Respiratory motion does not only affect the B 1 + $$ {B}_1^{+} $$ distribution and hence the image contrast, but also location and magnitude of the peak spatial SAR. Therefore, respiration effects may need to be included in safety analyses of RF coils applied to the human thorax.


Asunto(s)
Campos Electromagnéticos , Imagen por Resonancia Magnética , Simulación por Computador , Humanos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Ondas de Radio
18.
Magn Reson Med ; 88(4): 1702-1719, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35692053

RESUMEN

PURPOSE: To develop and evaluate a novel RF shimming optimization strategy tailored to improve the transmit efficiency in turbo spin echo imaging when performing time-interleaved acquisition of modes (TIAMO) at ultrahigh fields. THEORY AND METHODS: A nonlocalized efficiency shimming cost function is proposed and extended to perform TIAMO using acquisition modes optimized for refocused echoes (AMORE). The nonlocalized efficiency shimming was demonstrated in brain and knee imaging at 7 Tesla. Phantom and in vivo torso imaging studies were performed to compare the performance between AMORE and previously proposed TIAMO mode optimizations with and without localized constraints in turbo spin echo and gradient echo acquisitions. RESULTS: The proposed nonlocalized efficiency RF shimming produced a circularly polarized-like field with fewer signal dropouts in the brain and knee. For larger targets, AMORE was used and required a significantly lower transmitter voltage to produce a similar contrast to existing TIAMO mode design approaches for turbo spin echo as well as gradient echo acquisitions. In vivo, AMORE effectively reduced signal dropout in the interior torso while providing more uniform contrast with reduced transmit power. A local constraint further improved performance for a target region while maintaining performance in the larger FOV. CONCLUSION: AMORE based on the presented nonlocalized efficiency shimming cost function demonstrated improved contrast and SNR uniformity as well as increased transmit efficiency for both gradient echo and turbo spin echo acquisitions.


Asunto(s)
Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Magnética , Algoritmos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen
19.
JAMA Netw Open ; 5(5): e229712, 2022 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-35499827

RESUMEN

Importance: The factors associated with the failure of nonoperative management of appendicitis and the differences in patient-reported outcomes between successful and unsuccessful nonoperative management remain unknown. Objectives: To investigate factors associated with the failure of nonoperative management of appendicitis and compare patient-reported outcomes between patients whose treatment succeeded and those whose treatment failed. Design, Setting, and Participants: This study was a planned subgroup secondary analysis conducted in 10 children's hospitals that included 370 children aged 7 to 17 years with uncomplicated appendicitis enrolled in a prospective, nonrandomized clinical trial between May 1, 2015, and October 31, 2018, with 1-year follow-up comparing nonoperative management with antibiotics vs surgery for uncomplicated appendicitis. Statistical analysis was performed from November 1, 2019, to February 12, 2022. Interventions: Nonoperative management with antibiotics vs surgery. Main Outcomes and Measures: Failure of nonoperative management and patient-reported outcomes. The relative risk (RR) of failure based on sociodemographic and clinical characteristics was calculated. Patient-reported outcomes were compared based on the success or failure of nonoperative management. Results: Of 370 patients (34.6% of 1068 total patients; 229 boys [61.9%]; median age, 12.3 years [IQR, 10.0-14.6 years]) enrolled in the nonoperative group, treatment failure occurred for 125 patients (33.8%) at 1 year, with 53 patients (14.3%) undergoing appendectomy during initial hospitalization and 72 patients (19.5%) experiencing delayed treatment failure after hospital discharge. Higher patient-reported pain at presentation was associated with increased risk of in-hospital treatment failure (RR, 2.1 [95% CI, 1.0-4.4]) but not delayed treatment failure (RR, 1.3 [95% CI, 0.7-2.3]) or overall treatment failure at 1 year (RR, 1.5 [95% CI, 1.0-2.2]). Pain duration greater than 24 hours was associated with decreased risk of delayed treatment failure (RR, 0.3 [95% CI, 0.1-1.0]) but not in-hospital treatment failure (RR, 1.2 [95% CI, 0.5-2.7]) or treatment failure at 1 year (RR, 0.7 [95% CI, 0.4-1.2]). There was no increased risk of treatment failure associated with age, white blood cell count, sex, race, ethnicity, primary language, insurance status, transfer status, symptoms at presentation, or imaging results. Health care satisfaction at 30 days and patient-reported, health-related quality of life at 30 days and 1 year were not different. Satisfaction with the decision was higher with successful nonoperative management at 30 days (28.0 vs 27.0; difference, 1.0 [95% CI, 0.01-2.0]) and 1 year (28.1 vs 27.0; difference, 1.1 [95% CI, 0.2-2.0]). Conclusions and Relevance: This analysis suggests that a higher pain level at presentation was associated with a higher risk of initial failure of nonoperative management and that a longer duration of pain was associated with lower risk of delayed treatment failure. Although satisfaction was high in both groups, satisfaction with the treatment decision was higher among patients with successful nonoperative management at 1 year. Trial Registration: ClinicalTrials.gov Identifier: NCT02271932.


Asunto(s)
Apendicitis , Antibacterianos/uso terapéutico , Apendicitis/complicaciones , Apendicitis/epidemiología , Apendicitis/terapia , Niño , Femenino , Humanos , Masculino , Dolor/tratamiento farmacológico , Estudios Prospectivos , Calidad de Vida
20.
MAGMA ; 35(4): 631-644, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35579785

RESUMEN

Multiparametric MRI of the prostate at clinical magnetic field strengths (1.5/3 Tesla) has emerged as a reliable noninvasive imaging modality for identifying clinically significant cancer, enabling selective sampling of high-risk regions with MRI-targeted biopsies, and enabling minimally invasive focal treatment options. With increased sensitivity and spectral resolution, ultra-high-field (UHF) MRI (≥ 7 Tesla) holds the promise of imaging and spectroscopy of the prostate with unprecedented detail. However, exploiting the advantages of ultra-high magnetic field is challenging due to inhomogeneity of the radiofrequency field and high local specific absorption rates, raising local heating in the body as a safety concern. In this work, we review various coil designs and acquisition strategies to overcome these challenges and demonstrate the potential of UHF MRI in anatomical, functional and metabolic imaging of the prostate and pelvic lymph nodes. When difficulties with power deposition of many refocusing pulses are overcome and the full potential of metabolic spectroscopic imaging is used, UHF MR(S)I may aid in a better understanding of the development and progression of local prostate cancer. Together with large field-of-view and low-flip-angle anatomical 3D imaging, 7 T MRI can be used in its full strength to characterize different tumor stages and help explain the onset and spatial distribution of metastatic spread.


Asunto(s)
Imagen por Resonancia Magnética , Neoplasias de la Próstata , Estudios de Factibilidad , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Próstata/metabolismo , Neoplasias de la Próstata/metabolismo , Ondas de Radio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA