Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Lab Chip ; 24(7): 2094-2106, 2024 03 26.
Artículo en Inglés | MEDLINE | ID: mdl-38444329

RESUMEN

Organ-on-chip (OOC) technology has recently emerged as a powerful tool to mimic physiological or pathophysiological conditions through cell culture in microfluidic devices. One of its main goals is bypassing animal testing and encouraging more personalized medicine. The recent incorporation of hydrogels as 3D scaffolds into microfluidic devices has changed biomedical research since they provide a biomimetic extracellular matrix to recreate tissue architectures. However, this technology presents some drawbacks such as the necessity for physical structures as pillars to confine these hydrogels, as well as the difficulty in reaching different shapes and patterns to create convoluted gradients or more realistic biological structures. In addition, pillars can also interfere with the fluid flow, altering the local shear forces and, therefore, modifying the mechanical environment in the OOC model. In this work, we present a methodology based on a plasma surface treatment that allows building cell culture chambers with abutment-free patterns capable of producing precise shear stress distributions. Therefore, pillarless devices with arbitrary geometries are needed to obtain more versatile, reliable, and biomimetic experimental models. Through computational simulation studies, these shear stress changes are demonstrated in different designed and fabricated geometries. To prove the versatility of this new technique, a blood-brain barrier model has been recreated, achieving an uninterrupted endothelial barrier that emulates part of the neurovascular network of the brain. Finally, we developed a new technology that could avoid the limitations mentioned above, allowing the development of biomimetic OOC models with complex and adaptable geometries, with cell-to-cell contact if required, and where fluid flow and shear stress conditions could be controlled.


Asunto(s)
Técnicas de Cultivo de Célula , Hidrogeles , Animales , Hidrogeles/química , Endotelio , Matriz Extracelular/química , Dispositivos Laboratorio en un Chip
2.
Nanomaterials (Basel) ; 13(19)2023 Oct 03.
Artículo en Inglés | MEDLINE | ID: mdl-37836338

RESUMEN

Alzheimer's disease is characterized by a combination of several neuropathological hallmarks, such as extracellular aggregates of beta amyloid (Aß). Numerous alternatives have been studied for inhibiting Aß aggregation but, at this time, there are no effective treatments available. Here, we developed the tri-component nanohybrid system AuNPs@POM@PEG based on gold nanoparticles (AuNPs) covered with polyoxometalates (POMs) and polyethylene glycol (PEG). In this work, AuNPs@POM@PEG demonstrated the inhibition of the formation of amyloid fibrils, showing a 75% decrease in Aß aggregation in vitro. As it is a potential candidate for the treatment of Alzheimer's disease, we evaluated the cytotoxicity of AuNPs@POM@PEG and its ability to cross the blood-brain barrier (BBB). We achieved a stable nanosystem that is non-cytotoxic below 2.5 nM to human neurovascular cells. The brain permeability of AuNPs@POM@PEG was analyzed in an in vitro microphysiological model of the BBB (BBB-on-a-chip), containing 3D human neurovascular cell co-cultures and microfluidics. The results show that AuNPs@POM@PEG was able to cross the brain endothelial barrier in the chip and demonstrated that POM does not affect the barrier integrity, giving the green light to further studies into this system as a nanotherapeutic.

3.
Nanoscale ; 15(17): 7929-7944, 2023 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-37067009

RESUMEN

A hydroxycinnamic acid derivative, namely ferulic acid (FA) has been successfully encapsulated in polymeric nanoparticles (NPs) based on poly(lactic-co-glycolic acid) (PLGA). FA-loaded polymeric NPs were prepared from O/W nano-emulsion templates using the phase inversion composition (PIC) low-energy emulsification method. The obtained PLGA NPs exhibited high colloidal stability, good drug-loading capacity, and particle hydrodynamic diameters in the range of 74 to 117 nm, depending on the FA concentration used. In vitro drug release studies confirmed a diffusion-controlled mechanism through which the amount of released FA reached a plateau at 60% after 6 hours-incubation. Five kinetic models were used to fit the FA release data as a function of time. The Weibull distribution and Korsmeyer-Peppas equation models provided the best fit to our experimental data and suggested quasi-Fickian diffusion behaviour. Moderate dose-response antioxidant and radical scavenging activities of FA-loaded PLGA NPs were demonstrated using the DPPH˙ assay achieving inhibition activities close to 60 and 40%, respectively. Cell culture studies confirmed that FA-loaded NPs were not toxic according to the MTT colorimetric assay, were able to internalise efficiently SH-SY5Y neuronal cells and supressed the intracellular ROS-level induced by H2O2 leading to 52% and 24.7% of cellular viability at 0.082 and 0.041 mg mL-1, respectively. The permeability of the NPs through the blood brain barrier was tested with an in vitro organ-on-a-chip model to evaluate the ability of the FA-loaded PLGA and non-loaded PLGA NPs to penetrate to the brain. NPs were able to penetrate the barrier, but permeability decreased when FA was loaded. These results are promising for the use of loaded PLGA NPs for the management of neurological diseases.


Asunto(s)
Nanopartículas , Neuroblastoma , Humanos , Copolímero de Ácido Poliláctico-Ácido Poliglicólico , Ácidos Cumáricos/farmacología , Ácido Poliglicólico , Ácido Láctico , Barrera Hematoencefálica , Peróxido de Hidrógeno , Tamaño de la Partícula , Portadores de Fármacos/farmacología
4.
J Nanobiotechnology ; 21(1): 115, 2023 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-36978078

RESUMEN

BACKGROUND: The lack of predictive models that mimic the blood-brain barrier (BBB) hinders the development of effective drugs for neurodegenerative diseases. Animal models behave differently from humans, are expensive and have ethical constraints. Organ-on-a-chip (OoC) platforms offer several advantages to resembling physiological and pathological conditions in a versatile, reproducible, and animal-free manner. In addition, OoC give us the possibility to incorporate sensors to determine cell culture features such as trans-endothelial electrical resistance (TEER). Here, we developed a BBB-on-a-chip (BBB-oC) platform with a TEER measurement system in close distance to the barrier used for the first time for the evaluation of the permeability performance of targeted gold nanorods for theranostics of Alzheimer's disease. GNR-PEG-Ang2/D1 is a therapeutic nanosystem previously developed by us consisting of gold nanorods (GNR) functionalized with polyethylene glycol (PEG), angiopep-2 peptide (Ang2) to overcome the BBB and the D1 peptide as beta amyloid fibrillation inhibitor, finally obtaining GNR-PEG-Ang2/D1 which showed to be useful for disaggregation of the amyloid in in vitro and in vivo models. In this work, we evaluated its cytotoxicity, permeability, and some indications of its impact on the brain endothelium by employing an animal-free device based on neurovascular human cells. RESULTS: In this work, we fabricated a BBB-oC with human astrocytes, pericytes and endothelial cells and a TEER measuring system (TEER-BBB-oC) integrated at a micrometric distance of the endothelial barrier. The characterization displayed a neurovascular network and the expression of tight junctions in the endothelium. We produced GNR-PEG-Ang2/D1 and determined its non-cytotoxic range (0.05-0.4 nM) for plated cells included in the BBB-oC and confirmed its harmless effect at the highest concentration (0.4 nM) in the microfluidic device. The permeability assays revealed that GNR-PEG-Ang2/D1 cross the BBB and this entry is facilitated by Ang2 peptide. Parallel to the permeability analysis of GNR-PEG-Ang2/D1, an interesting behavior of the TJs expression was observed after its administration probably related to the ligands on the nanoparticle surface. CONCLUSIONS: BBB-oC with a novel TEER integrated setup which allow a correct read-out and cell imaging monitoring was proven as a functional and throughput platform to evaluate the brain permeability performance of nanotherapeutics in a physiological environment with human cells, putting forward a viable alternative to animal experimentation.


Asunto(s)
Enfermedad de Alzheimer , Barrera Hematoencefálica , Humanos , Barrera Hematoencefálica/metabolismo , Células Endoteliales/metabolismo , Enfermedad de Alzheimer/tratamiento farmacológico , Enfermedad de Alzheimer/metabolismo , Impedancia Eléctrica , Oro/farmacología , Astrocitos/metabolismo , Péptidos beta-Amiloides/metabolismo , Endotelio/metabolismo , Permeabilidad , Dispositivos Laboratorio en un Chip
5.
ACS Sens ; 7(5): 1237-1247, 2022 05 27.
Artículo en Inglés | MEDLINE | ID: mdl-35559649

RESUMEN

Over the most recent decades, the development of new biological platforms to study disease progression and drug efficacy has been of great interest due to the high increase in the rate of neurodegenerative diseases (NDDs). Therefore, blood-brain barrier (BBB) as an organ-on-a-chip (OoC) platform to mimic brain-barrier performance could offer a deeper understanding of NDDs as well as a very valuable tool for drug permeability testing for new treatments. A very attractive improvement of BBB-oC technology is the integration of detection systems to provide continuous monitoring of biomarkers in real time and a fully automated analysis of drug permeably, rendering more efficient platforms for commercialization. In this Perspective, an overview of the main BBB-oC configurations is introduced and a critical vision of the BBB-oC platforms integrating electronic read out systems is detailed, indicating the strengths and weaknesses of current devices, proposing the great potential for biosensors integration in BBB-oC. In this direction, we name potential biomarkers to monitor the evolution of NDDs related to the BBB and/or drug cytotoxicity using biosensor technology in BBB-oC.


Asunto(s)
Técnicas Biosensibles , Enfermedades Neurodegenerativas , Barrera Hematoencefálica , Encéfalo , Humanos , Dispositivos Laboratorio en un Chip , Enfermedades Neurodegenerativas/diagnóstico
6.
Clin Transplant ; 36(3): e14550, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34851532

RESUMEN

Multicenter, prospective, observational study to compare the relative bioavailability of once-daily tacrolimus formulations in de novo kidney transplant recipients. De novo kidney transplant recipients who started a tacrolimus-based regimen were included 14 days post-transplant and followed up for 6 months. Data from 218 participants were evaluated: 129 in the LCPT group (Envarsus) and 89 in the PR-Tac (Advagraf) group. Patients in the LCPT group exhibited higher relative bioavailability (Cmin /total daily dose [TDD]) vs. PR-Tac (61% increase; P < .001) with similar Cmin and 30% lower TDD levels (P < .0001). The incidence of treatment failure was 3.9% in the LCPT group and 9.0% in the PR-Tac group (P = .117). Study discontinuation rates were 6.2% in the LCPT group and 12.4% in the PR-Tac group (P = .113). Adverse events, renal function and other complications were comparable between groups. The median accumulated dose of tacrolimus in the LCPT group from day 14 to month 6 was 889 mg. Compared to PR-Tac, LCPT showed higher relative bioavailability, similar effectiveness at preventing allograft rejection, comparable effect on renal function, safety, adherence, treatment failure and premature discontinuation rates.


Asunto(s)
Trasplante de Riñón , Tacrolimus , Disponibilidad Biológica , Esquema de Medicación , Rechazo de Injerto/tratamiento farmacológico , Rechazo de Injerto/etiología , Rechazo de Injerto/prevención & control , Humanos , Inmunosupresores/uso terapéutico , Trasplante de Riñón/efectos adversos , Estudios Prospectivos , Tacrolimus/uso terapéutico , Receptores de Trasplantes
7.
Transplant Proc ; 54(1): 80-86, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34911620

RESUMEN

BACKGROUND: Neurotoxicity secondary to anticalcineurinics is a prevalent side effect in transplant recipients. Optical coherence tomography (OCT) scans the central nervous system by direct access to the retina. OCT assesses central nervous system involvement by measuring the thickness of the retinal layers, especially the ganglion cell layer (GCL). The retinal scan divides the scanned area into affected and unaffected segments, which can be quantified for each eye. The aim of this study was to determine retinal GCL thickness by means of OCT, analyzing the proportion of affected segments in individuals exposed to tacrolimus compared with a control group. MATERIALS AND METHODS: We evaluated 20 renal transplant recipients exposed to tacrolimus for ≥6 months. The number of affected segments in the GCL of the retina was quantified by OCT. The control group was drawn from the general population attending routine ophthalmologic checkups. RESULTS: Patients exposed to tacrolimus had a pathologic examination in 50% of cases compared with 20% in the control group (P < .044). Furthermore, among patients with an exposure time to tacrolimus >5 years, the examination was pathologic in 80% (P < .005). Linear regression analysis showed the presence of GCL segments with decreased thickness to be associated with the duration of exposure to tacrolimus (P = .036) and the time in dialysis before kidney transplant (P = .030). CONCLUSION: Although this is a preliminary study, OCT scanning could serve to detect the neurotoxic effect of tacrolimus on the retinal GCL and central nervous system in renal transplant recipients.


Asunto(s)
Tacrolimus , Tomografía de Coherencia Óptica , Humanos , Diálisis Renal , Retina/diagnóstico por imagen , Células Ganglionares de la Retina , Tacrolimus/efectos adversos
8.
J Biol Eng ; 15(1): 28, 2021 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-34930385

RESUMEN

Under intrauterine growth restriction (IUGR), abnormal attainment of the nutrients and oxygen by the fetus restricts the normal evolution of the prenatal causing in many cases high morbidity being one of the top-ten causes of neonatal death. The current gold standards in hospitals to detect this relevant problem is the clinical observation by echography, cardiotocography and Doppler. These qualitative techniques are not conclusive and requires risky invasive fetal scalp blood testing and/or amniocentesis. We developed micro-implantable multiparametric electrochemical sensors for measuring ischemia in real time in fetal tissue and vascular. This implantable technology is designed to continuous monitoring for an early detection of ischemia to avoid potential fetal injury. Two miniaturized electrochemical sensors were developed based on oxygen and pH detection. The sensors were optimized in vitro under controlled concentration, to assess the selectivity and sensitivity required. The sensors were then validated in vivo in the ewe fetus model, by means of their insertion in the muscle leg and inside the iliac artery of the fetus. Ischemia was achieved by gradually obstructing the umbilical cord to regulate the amount of blood reaching the fetus. An important challenge in fetal monitoring is the detection of low levels of oxygen and pH changes under ischemic conditions, requiring high sensitivity sensors. Significant differences were observed in both; pH and pO2 sensors under changes from normoxia to hypoxia states in the fetus tissue and vascular with both sensors. Herein, we demonstrate the feasibility of the developed sensors for future fetal monitoring in medical applications.

9.
Biomedicines ; 9(10)2021 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-34680459

RESUMEN

Perinatal asphyxia is a major cause of severe brain damage and death. For its prenatal identification, Doppler ultrasound has been used as a surrogate marker of fetal hypoxia. However, Doppler evaluation cannot be performed continuously. We have evaluated the performance of a miniaturized multiparametric sensor aiming to evaluate tissular oxygen and pH changes continuously in an umbilical cord occlusion (UCO) sheep model. The electrochemical sensors were inserted in fetal hindlimb skeletal muscle and electrochemical signals were recorded. Fetal hemodynamic changes and metabolic status were also monitored during the experiment. Additionally, histological assessment of the tissue surrounding the sensors was performed. Both electrochemical sensors detected the pO2 and pH changes induced by the UCO and these changes were correlated with hemodynamic parameters as well as with pH and oxygen content in the blood. Finally, histological assessment revealed no signs of alteration on the same day of insertion. This study provides the first evidence showing the application of miniaturized multiparametric electrochemical sensors detecting changes in oxygen and pH in skeletal muscular tissue in a fetal sheep model.

10.
Talanta ; 226: 122045, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-33676640

RESUMEN

Hypoxia is a common medical problem, sometimes difficult to detect and caused by different situations. Control of hypoxia is of great medical importance and early detection is essential to prevent life threatening complications. However, the few current methods are invasive, expensive, and risky. Thus, the development of reliable and accurate sensors for the continuous monitoring of hypoxia is of vital importance for clinical monitoring. Herein, we report an implantable sensor to address these needs. The developed device is a low-cost, miniaturised implantable electrochemical sensor for monitoring hypoxia in tissue by means of pH detection. This technology is based on protonation/deprotonation of polypyrrole conductive polymer. The sensor was optimized in vitro and tested in vivo intramuscularly and ex vivo in blood in adult rabbits with respiration-induced hypoxia and correlated with the standard device ePOCTM. The sensor demonstrated excellent sensitivity and reproducibility; 46.4 ± 0.4 mV/pH in the pH range of 4-9 and the selectivity coefficient exhibited low interference activity in vitro. The device was linear (R2 = 0.925) with a low dispersion of the values (n = 11) with a cut-off of 7.1 for hypoxia in vivo and ex vivo. Statistics with one-way ANOVA (α = 0.05), shows statistical differences between hypoxia and normoxia states and the good performance of the pH sensor, which demonstrated good agreement with the standard device. The sensor was stable and functional after 18 months. The excellent results demonstrated the feasibility of the sensors in real-time monitoring of intramuscular tissue and blood for medical applications.


Asunto(s)
Acidosis , Polímeros , Animales , Hipoxia/diagnóstico , Pirroles , Conejos , Reproducibilidad de los Resultados
11.
Clin Transplant ; 35(5): e14256, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33599030

RESUMEN

BACKGROUND: The use of mycophenolic acid (MPA) in women during pregnancy causes an increase in miscarriages and birth defects with a typical embryopathy profile. Although epidemiological data does not suggest a greater risk among the offspring of male kidney transplant recipients, the European Medicines Agency and The Spanish Agency of Medicines and Medical Devices introduced the recommendation of using contraceptive methods. METHODS: We conducted a national retrospective study in 15 Spanish Kidney Transplant Centers to evaluate the frequency of miscarriages and birth defects between the offspring from male kidney transplants recipients. We included 151 males who had fathered 239 offspring, 225 under MPA and 14 without MPA. RESULTS: The results of our study showed an incidence of miscarriages in the MPA group of 9.8%, and of birth defects of 4%. CONCLUSIONS: We observed an incidence of miscarriages between the offspring fathered by kidney transplant males under MPA lower than the general population. The incidence of birth defects was similar to the incidence described in other studies and the fact that we did not find the typical embryopathy profile makes it difficult to associate them to the use of MPA. Because of that, we urge the European and Spanish Agencies to reconsider their recommendations for males.


Asunto(s)
Trasplante de Riñón , Ácido Micofenólico , Femenino , Humanos , Inmunosupresores , Masculino , Embarazo , Estudios Retrospectivos , Comprimidos Recubiertos , Receptores de Trasplantes
12.
Talanta ; 225: 121898, 2021 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-33592692

RESUMEN

The current situation of the Covid-19 pandemic is indicated by a huge number of infections, high lethality, and rapid spread. These circumstances have stopped the activity of almost the entire world, affecting severely the global economy. A rapid diagnosis of the Covid-19 and a generalized testing protocol is essential to fight against the pandemic and to maintain health control in the population. Principal biosensing and diagnostic technologies used to monitor the spread of the SARS-CoV-2 are based on specific genomic analysis and rapid immune tests, both with different technology platforms that include advantages and disadvantages. Most of the in vitro diagnosis companies are competing to be the first on validating under different regulations their technology for placing their platforms for Covid-19 detection as fast as possible in this big international market. A comprehensive analysis of the commercialized technologies for the genomic based sensing and the antibody/antigen detection methods devoted to Covid-19 diagnosis is described in this review, which have been detailed and listed under different countries regulations. The effectiveness of the described technologies throughout the different stages of the disease and a critical comparison of the emerging technologies in the market to counterattack this pandemic have been discussed.


Asunto(s)
COVID-19/diagnóstico , Inmunoensayo/métodos , Técnicas de Diagnóstico Molecular/métodos , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , SARS-CoV-2/aislamiento & purificación , Anticuerpos Antivirales/inmunología , Antígenos Virales/inmunología , COVID-19/epidemiología , COVID-19/virología , Humanos , Pandemias , SARS-CoV-2/genética , SARS-CoV-2/fisiología , Sensibilidad y Especificidad
13.
J Transl Med ; 19(1): 53, 2021 02 04.
Artículo en Inglés | MEDLINE | ID: mdl-33541374

RESUMEN

BACKGROUND: One of the most prevalent causes of fetal hypoxia leading to stillbirth is placental insufficiency. Hemodynamic changes evaluated with Doppler ultrasound have been used as a surrogate marker of fetal hypoxia. However, Doppler evaluation cannot be performed continuously. As a first step, the present work aimed to evaluate the performance of miniaturized electrochemical sensors in the continuous monitoring of oxygen and pH changes in a model of acute hypoxia-acidosis. METHODS: pH and oxygen electrochemical sensors were evaluated in a ventilatory hypoxia rabbit model. The ventilator hypoxia protocol included 3 differential phases: basal (100% FiO2), the hypoxia-acidosis period (10% FiO2) and recovery (100% FiO2). Sensors were tested in blood tissue (ex vivo sensing) and in muscular tissue (in vivo sensing). pH electrochemical and oxygen sensors were evaluated on the day of insertion (short-term evaluation) and pH electrochemical sensors were also tested after 5 days of insertion (long-term evaluation). pH and oxygen sensing were registered throughout the ventilatory hypoxia protocol (basal, hypoxia-acidosis, and recovery) and were compared with blood gas metabolites results from carotid artery catheterization (obtained with the EPOC blood analyzer). Finally, histological assessment was performed on the sensor insertion site. One-way ANOVA was used for the analysis of the evolution of acid-based metabolites and electrochemical sensor signaling results; a t-test was used for pre- and post-calibration analyses; and chi-square analyses for categorical variables. RESULTS: At the short-term evaluation, both the pH and oxygen electrochemical sensors distinguished the basal and hypoxia-acidosis periods in both the in vivo and ex vivo sensing. However, only the ex vivo sensing detected the recovery period. In the long-term evaluation, the pH electrochemical sensor signal seemed to lose sensibility. Finally, histological assessment revealed no signs of alteration on the day of evaluation (short-term), whereas in the long-term evaluation a sub-acute inflammatory reaction adjacent to the implantation site was detected. CONCLUSIONS: Miniaturized electrochemical sensors represent a new generation of tools for the continuous monitoring of hypoxia-acidosis, which is especially indicated in high-risk pregnancies. Further studies including more tissue-compatible material would be required in order to improve long-term electrochemical sensing.


Asunto(s)
Acidosis , Oxígeno , Animales , Femenino , Concentración de Iones de Hidrógeno , Hipoxia , Modelos Animales , Embarazo , Conejos
14.
Biosensors (Basel) ; 11(1)2021 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-33445512

RESUMEN

Alzheimer's disease (AD) is a neurodegenerative disorder, characterized by a functional deterioration of the brain. Currently, there are selected biomarkers for its diagnosis in cerebrospinal fluid. However, its extraction has several disadvantages for the patient. Therefore, there is an urgent need for a detection method using sensitive and selective blood-based biomarkers. Kynurenic acid (KYNA) is a potential biomarker candidate for this purpose. The alteration of the KYNA levels in blood has been related with inflammatory processes in the brain, produced as a protective function when neurons are damaged. This paper describes a novel electrochemical immunosensor for KYNA detection, based on successive functionalization multi-electrode array. The resultant sensor was characterized by cyclic voltammetry (CV), chronoamperometry (CA), and electrochemical impedance spectroscopy (EIS). The proposed biosensor detects KYNA within a linear calibration range from 10 pM to 100 nM using CA and EIS, obtaining a limit of detection (LOD) of 16.9 pM and 37.6 pM in buffer, respectively, being the lowest reported LOD for this biomarker. Moreover, to assess our device closer to the real application, the developed immunosensor was also tested under human serum matrix, obtaining an LOD of 391.71 pM for CA and 278.8 pM for EIS with diluted serum.


Asunto(s)
Enfermedad de Alzheimer/diagnóstico , Técnicas Biosensibles/métodos , Ácido Quinurénico/análisis , Enfermedad de Alzheimer/sangre , Biomarcadores/análisis , Biomarcadores/sangre , Técnicas Biosensibles/instrumentación , Espectroscopía Dieléctrica , Diagnóstico Precoz , Electrodos , Humanos , Ácido Quinurénico/sangre , Límite de Detección , Masculino
15.
Sensors (Basel) ; 20(5)2020 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-32121271

RESUMEN

Cancer represents one of the conditions with the most causes of death worldwide. Common methods for its diagnosis are based on tissue biopsies-the extraction of tissue from the primary tumor, which is used for its histological analysis. However, this technique represents a risk for the patient, along with being expensive and time-consuming and so it cannot be frequently used to follow the progress of the disease. Liquid biopsy is a new cancer diagnostic alternative, which allows the analysis of the molecular information of the solid tumors via a body fluid draw. This fluid-based diagnostic method displays relevant advantages, including its minimal invasiveness, lower risk, use as often as required, it can be analyzed with the use of microfluidic-based platforms with low consumption of reagent, and it does not require specialized personnel and expensive equipment for the diagnosis. In recent years, the integration of sensors in microfluidics lab-on-a-chip devices was performed for liquid biopsies applications, granting significant advantages in the separation and detection of circulating tumor nucleic acids (ctNAs), circulating tumor cells (CTCs) and exosomes. The improvements in isolation and detection technologies offer increasingly sensitive and selective equipment's, and the integration in microfluidic devices provides a better characterization and analysis of these biomarkers. These fully integrated systems will facilitate the generation of fully automatized platforms at low-cost for compact cancer diagnosis systems at an early stage and for the prediction and prognosis of cancer treatment through the biomarkers for personalized tumor analysis.


Asunto(s)
Detección Precoz del Cáncer/métodos , Biopsia Líquida/métodos , Microfluídica/métodos , Biomarcadores de Tumor/sangre , Ácidos Nucleicos Libres de Células/sangre , Exosomas/patología , Humanos , Dispositivos Laboratorio en un Chip , Células Neoplásicas Circulantes/patología
16.
Biosens Bioelectron ; 153: 112028, 2020 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-31989937

RESUMEN

Oxygen is vital for energy metabolism in mammals and the variability of the concentration is considered a clinical alert for a wide range of metabolic malfunctions in medicine. In this article, we describe the development and application of a micro-needle implantable platinum-based electrochemical sensor for measuring partial pressure of oxygen in intramuscular tissue (in-vivo) and vascular blood (ex-vivo). The Pt-Nafion® sensor was characterized morphological and electrochemically showing a higher sensitivity of -2.496 nA/mmHg (-1.495 nA/µM) when comparing with its bare counterpart. Our sensor was able to discriminate states with different oxygen partial pressures (pO2) for ex-vivo (blood) following the same trend of the commercial gas analyzer used as standard. For in-vivo (intramuscular) experiments, since there is not a gold standard for measuring pO2 in tissue, it was not possible to correlate the obtained currents with the pO2 in tissue. However, our sensor was able to detect clear statistical differences of O2 between hyperoxia and hypoxia states in tissue.


Asunto(s)
Técnicas Biosensibles/métodos , Técnicas Electroquímicas/métodos , Oxígeno/análisis , Animales , Electricidad , Electrodos Implantados , Polímeros de Fluorocarbono/química , Humanos , Hipoxia-Isquemia Encefálica/metabolismo , Masculino , Microelectrodos , Agujas , Platino (Metal)/química , Conejos
17.
Int J Mol Sci ; 19(10)2018 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-30248975

RESUMEN

Cancer is one of the greatest threats facing our society, being the second leading cause of death globally. Currents strategies for cancer diagnosis consist of the extraction of a solid tissue from the affected area. This sample enables the study of specific biomarkers and the genetic nature of the tumor. However, the tissue extraction is risky and painful for the patient and in some cases is unavailable in inaccessible tumors. Moreover, a solid biopsy is expensive and time consuming and cannot be applied repeatedly. New alternatives that overcome these drawbacks are rising up nowadays, such as liquid biopsy. A liquid biopsy is the analysis of biomarkers in a non-solid biological tissue, mainly blood, which has remarkable advantages over the traditional method; it has no risk, it is non-invasive and painless, it does not require surgery and reduces cost and diagnosis time. The most studied cancer non-invasive biomarkers are circulating tumor cells (CTCs), circulating tumor DNA (ctDNA), and exosomes. These circulating biomarkers play a key role in the understanding of metastasis and tumorigenesis, which could provide a better insight into the evolution of the tumor dynamics during treatment and disease progression. Improvements in isolation technologies, based on a higher grade of purification of CTCs, exosomes, and ctDNA, will provide a better characterization of biomarkers and give rise to a wide range of clinical applications, such as early detection of diseases, and the prediction of treatment responses due to the discovery of personalized tumor-related biomarkers.


Asunto(s)
Biomarcadores de Tumor/sangre , Biopsia/métodos , Biopsia Líquida/métodos , Humanos , Células Neoplásicas Circulantes/metabolismo
18.
Biosens Bioelectron ; 121: 54-61, 2018 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-30196048

RESUMEN

Detection of the hybridisation events is of great importance in many different biotechnology applications such as diagnosis, computing, molecular bioelectronics, and among others. However, one important drawback is the low current of some redox reporters that limits their application. This paper demonstrates the powerful features of molecular wires, in particular the case of S-[4-[2-[4-(2-Phenylethynyl)phenyl]ethynyl]phenyl] thiol molecule and the key role that play the nanometric design of the capture probe linkers to achieve an efficient couple of the DNA complementary ferrocene label with the molecular wire for an effective electron transfer in co-immobilised self-assembled monolayers (SAMs) for DNA hybridisation detection. In this article, the length of the linker capture probe was studied for electron transfer enhancement from the ferrocene-motifs of immobilised molecules towards the electrode surface to obtain higher kinetics in the presence of thiolated molecular wires. The use of the right couple of capture probe linker and molecular wire has found to be beneficial as it helps to amplify eightfold the signal obtained.


Asunto(s)
Técnicas Biosensibles/métodos , ADN/química , Electrodos , Hibridación de Ácido Nucleico , Compuestos de Sulfhidrilo/química
19.
Electrophoresis ; 38(21): 2712-2720, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-28504351

RESUMEN

Nanogap electrodes have attracted a lot of consideration as promising platform for molecular electronic and biomolecules detection. This is mainly for their higher aspect ratio, and because their electrical properties are easily accessed by current-voltage measurements. Nevertheless, application of standard current-voltages measurements used to characterize nanogap response, and/or to modify specific nanogap electrodes properties, represents an issue. Since the strength of electrical fields in nanoscaled devices can reach high values, even at low voltages. Here, we analyzed the effects induced by different methods of surface modification of nanogap electrodes, in test-voltage application, employed for the electrical detection of a desoxyribonucleic acid (DNA) target. Nanogap electrodes were functionalized with two antisymmetric oligo-probes designed to have 20 terminal bases complementary to the edges of the target, which after hybridization bridges the nanogap, closing the electrical circuit. Two methods of functionalization were studied for this purpose; a random self-assembling of a mixture of the two oligo-probes (OPs) used in the platform, and a selective method that controls the position of each OP at selected side of nanogap electrodes. We used for this aim, the electrophoretic effect induced on negatively charged probes by the application of an external direct current voltage. The results obtained with both functionalization methods where characterized and compared in terms of electrode surface covering, calculated by using voltammetry analysis. Moreover, we contrasted the electrical detection of a DNA target in the nanogap platform either in site-selective and in randomly assembled nanogap. According to our results, a denser, although not selective surface functionalization, is advantageous for such kind of applications.


Asunto(s)
Técnicas Biosensibles/instrumentación , ADN/análisis , Nanoestructuras/química , Sondas de Oligonucleótidos/química , Técnicas Electroquímicas/instrumentación , Electrodos , Campos Electromagnéticos , Electroforesis/instrumentación , Oro/química , Humanos , Nanotecnología , Dióxido de Silicio/química , Propiedades de Superficie , Titanio/química
20.
Nanotechnology ; 28(13): 135702, 2017 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-28151432

RESUMEN

Carbon nanotubes (CNTs) have been the subject of many studies due to their unique structure and desirable properties. However, the ability to solubilize and separate single CNTs from the bundles they form is still a challenge that needs to be overcome in order to extend their applications in the field of Nanotechnology. Covalent interactions are designed to modify CNTs surface and so prevent agglomeration. Though, this method alters the structures and intrinsic properties of CNTs. In the present work, noncovalent approaches to functionalize and solubilize CNTs are studied in detail. A dispersion kinetic study was performed to characterize the ability of different type of surfactants (non-ionic, anionic, cationic and biopolymer) to unzip CNT bundles. The dispersion kinetic study performed depicts the distinct CNTs bundles unzipping behavior of the different type of surfactants and the results elucidate specific wavelengths in relation with the degree of CNT clustering, which provides new tools for a deeper understanding and characterization of CNTs. Small angle x-ray scattering and transmission electron microscopy results are in agreement with UV-vis-NIR observations, revealing perfectly monodispersed CNTs for the biopolymer and cationic surfactant.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA