Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Indian Heart J ; 70(6): 864-871, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30580858

RESUMEN

AIM: To evaluate Attain Performa (Medtronic, Dublin, Ireland) quadripolar lead performance in clinical practice and, secondarily, to compare its long term clinical outcomes vs bipolar leads for left ventricular (LV) pacing. METHODS AND RESULTS: We retrospectively analyzed clinical, procedural and follow-up data of 215 patients implanted with a quadripolar lead. One hundred and twenty one patients implanted with bipolar lead were selected to compare long-term clinical outcomes. The quadripolar lead was implanted in the target vein in 196 patients (91%) without acute dislodgements. In 50% of patients the chosen final pacing configuration at implant would not have been available with bipolar leads. A dedicated quadripolar pacing vector was chosen more frequently when the LV tip location was apical than otherwise (65.6% vs 42.7%, p=0.003). After a median follow-up of 14 months, the LV pacing threshold was less than 2.5V at 0.4ms in 98 patients (90%) with a safety margin between phrenic nerve and LV pacing threshold >3V in 97 patients (89%). We observed a slight trend toward a lower risk of heart failure worsening and a lower incidence of ventricular arrhythmias and pulmonary congestion in patients implanted with quadripolar leads compared with the control group. CONCLUSION: Quadripolar leads improve the management of phrenic nerve stimulation at no trade-off with pacing threshold and lead stability. Quadripolar leads seems to be associated with a lower incidence of VT/VF and pulmonary congestion, when compared with bipolar leads, but further investigations are necessary to confirm that this positive effect is associated with better LV reverse remodeling.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Electrodos Implantados , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos , Remodelación Ventricular/fisiología , Anciano , Diseño de Equipo , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/fisiopatología , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
2.
J Endocrinol Invest ; 41(2): 223-231, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28711969

RESUMEN

PURPOSE: Several studies have reported an association between hyperuricemia and increased risk of permanent atrial fibrillation (AF) in patients with and without type 2 diabetes mellitus (T2DM). Currently, no published data are available on the relationship between hyperuricemia and risk of paroxysmal AF. METHODS: We retrospectively evaluated 245 T2DM outpatients without pre-existing AF, cancer, cirrhosis and end-stage renal disease, who underwent a 24-h ECG-Holter monitoring for various clinical indications. Hyperuricemia was defined as a serum uric acid level >7 mg/dl for men and >6 mg/dl for women or allopurinol use. The diagnosis of paroxysmal AF was confirmed in affected individuals on the basis of 24-h ECG-Holter monitoring by experienced cardiologists. RESULTS: Hyperuricemia was observed in 59 (24.1%) patients, whereas paroxysmal AF was found in 11 (4.5%) patients. The prevalence of paroxysmal AF was higher in patients with hyperuricemia than in those without hyperuricemia (10.2 vs. 2.7%, p = 0.026). Logistic regression analysis showed that hyperuricemia was associated with an increased risk of prevalent paroxysmal AF. This association remained significant even after adjustment for age, metabolic syndrome and chronic kidney disease (adjusted-odds ratio 4.01, 95% CI 1.08-14.9; p = 0.039). Similar results were found when we used serum uric acid levels as a continuous measure. CONCLUSIONS: This study shows for the first time that hyperuricemia is independently associated with an approximately fourfold increased risk of prevalent paroxysmal AF in patients with T2DM. These findings may partly explain the increased risk of permanent atrial fibrillation and cardiovascular death observed among patients with hyperuricemia.


Asunto(s)
Fibrilación Atrial/epidemiología , Diabetes Mellitus Tipo 2/fisiopatología , Hiperuricemia/complicaciones , Ácido Úrico/sangre , Anciano , Fibrilación Atrial/sangre , Estudios Transversales , Diabetes Mellitus Tipo 2/sangre , Femenino , Humanos , Hiperuricemia/sangre , Hiperuricemia/patología , Italia/epidemiología , Masculino , Prevalencia , Estudios Retrospectivos , Factores de Riesgo
3.
Ital Heart J Suppl ; 1(11): 1443-50, 2000 Nov.
Artículo en Italiano | MEDLINE | ID: mdl-11109194

RESUMEN

BACKGROUND: In order to evaluate the cost-effectiveness of coronary angiography performed in a low volume Center, we examined our 1-year activity. METHODS: The organizational model of the multipurpose cardiac catheterization laboratory is described. In this type of facility both coronary angiographic and electrophysiological studies are performed. To evaluate the laboratory performance we examined the utilization level, the appropriateness of the studies, the complication rates and the number of studies that had to be repeated because of inadequate data or image quality. The costs were calculated for the in-house laboratory setting (the actual scenario) and for the 25 km distant laboratory setting (the historical scenario). RESULTS: The laboratory caseload of coronary angiography was 342 studies, 46% of the overall laboratory activity; 175 patients (51%) underwent non-pharmacological therapy, 129 patients (38%) were treated with medical therapy; the percentage of patients with normal coronary arteries was 11%. Two patients (0.58%) had vascular complications, 1 patient (0.29%) developed an acute myocardial infarction 2 hours after coronary angiography without any evidence of angiographic modifications at the repeated study. In no patient the study had to be repeated because of inadequate data or image quality. The mean cost of a coronary angiography was Lit. 512,000 (265 Euro) for the actual scenario; it would have been Lit. 694,000 (359 Euro) for the historical scenario, with Lit. 182,000 (94 Euro) saved. CONCLUSIONS: These findings are consistent with the accepted criteria of good laboratory performance and cost-effectiveness. Thus coronary angiography can be performed effectively and efficiently in a low volume Center.


Asunto(s)
Instituciones Cardiológicas/economía , Instituciones Cardiológicas/organización & administración , Angiografía Coronaria , Pruebas de Función Cardíaca/economía , Costos y Análisis de Costo , Hemodinámica , Humanos , Italia
4.
Ital Heart J Suppl ; 1(6): 803-7, 2000 Jun.
Artículo en Italiano | MEDLINE | ID: mdl-11204014

RESUMEN

Pulmonary embolism is a life-threatening condition that is accompanied by significant morbidity and mortality. In massive pulmonary embolism, where restoration of pulmonary arterial flow is urgently required, the only options available are surgical thromboembolectomy and/or thrombolytic therapy. Unfortunately, a large part of thromboembolic diseases is also considered as an absolute or relative contraindication to thrombolysis. The purpose of this paper was to emphasize the possibility of new thrombolytic agents of disregarding, according to circumstances, the contraindications to thrombolytic treatment.


Asunto(s)
Embolia Pulmonar/tratamiento farmacológico , Terapia Trombolítica , Activador de Tejido Plasminógeno/uso terapéutico , Anciano , Contraindicaciones , Femenino , Humanos , Persona de Mediana Edad , Proteínas Recombinantes/uso terapéutico
5.
Minerva Ortognatod ; 7(3-4): 175-9, 1989.
Artículo en Italiano | MEDLINE | ID: mdl-2640578

RESUMEN

A case of intracapsular pathology with myalgia has been solved by mandibular repositioning. Having identified the new mandibular position, it was made definitive with provisional prostheses and programmed sectorial orthodontics. Slavicek plates and programmed splints were used for orthodontic movements.


Asunto(s)
Férulas (Fijadores) , Síndrome de la Disfunción de Articulación Temporomandibular/terapia , Anciano , Femenino , Humanos , Aparatos Ortodóncicos , Ortodoncia Correctiva
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA