Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Injury ; 55(10): 111715, 2024 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-39032221

RESUMEN

PURPOSE: To identify risk factors predisposing patients to poor outcomes after fixation of periprosthetic hip fractures around femoral stems. METHODS: Prospective multicentre cohort study of fractures around a hip replacement stem managed by internal fixation. The primary outcome was one-year mortality, while secondary outcomes were local complications and healthcare burden-related outcomes (nursing facility utilization and hospital length of stay). RESULTS: One-year mortality was 16.2%. Age-adjusted Charlson Comorbidity Index score (OR=1.17; 95%CI=1.03-1.33)), Pfeiffer Short Portable Mental Status Questionnaire (SPMSQ) score (OR=1.16; 1.06-1.28), prosthetic dysfunction (OR=1.90; 1.00-3.61), and postoperative medical complications (OR=1.97; 1.06-3.68) were predictors of mortality. Patients with prior prosthetic dysfunction, lower Pfeiffer SPMSQ scores, Vancouver A fractures, and fractures fixed only using cerclages were at higher risk of local complications, which occurred in 9.3% of cases. Medical (OR=1.81; 1.05-3.13) and local complications (OR=5.56; 2.42-3.13) emerged as consistent risk factors for new institutionalization. Average hospitalization time was 13.9±9.2 days. Each day of fixation delay led to an average 1.4-day increase in total hospitalization. CONCLUSION: Frail periprosthetic hip-fracture patients with poorer functional status, dysfunctional replacements, and postoperative complications are at increased risk of mortality. Postoperative complications are more common in patients with dysfunctional arthroplasties, Vancouver A fractures, and fixation using cerclages alone. Postoperative complications were the most consistent predictor of higher healthcare resource utilization.

2.
Artículo en Inglés | MEDLINE | ID: mdl-38758388

RESUMEN

INTRODUCTION: The aim of the present study is to analyze the clinical-radiological outcomes of patients undergoing knee prosthesis revision surgery using constrained condylar prosthesis (LCCK; Zimmer-Biomet). MATERIAL AND METHODS: Retrospective study of 89 patients operated on between the years 2008 and 2020 with a minimum of 2 years of follow-up. Clinical outcomes were evaluated using the WOMAC Index score and KOOS scales. Radiological results (radiolucent lines, osteolysis, and cortical hypertrophy) were evaluated by two independent observers. Implant survival was analyzed using the Kaplan-Meier method. RESULTS: At the end of follow-up, a mean WOMAC Index score of 78.67 and KOOS score of 68.8 were obtained. Radiolucent lines (both non-progressive and progressive) were detected in 83.3% of the patients in the sample. Areas of osteolysis > 5 mm around the components were present in 6.75%. Cortical hypertrophy was seen around the femoral stem in 20.3% of cases, around the tibial stem in 20.3% and around both components in 6.76%. No statistically significant relationship was found between the presence of radiolucent lines, osteolysis or cortical hypertrophy with functional results. Implant survival was 88.1% at 13 years. CONCLUSION: The present study shows high survival of LCCK prosthesis in revision surgery. The progressive radiolucencies, were associated with worst clinical outcome.

3.
Orthop Rev (Pavia) ; 14(3): 31904, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35936801

RESUMEN

Introduction: Gluteus medius tendon tears may not be feasible for direct repair when significant retraction or fatty degeneration is present. Several augmentation techniques have been reported for challenging cases. We describe a novel technique using a transfer of the anterior portion of the gluteus maximus combined with synthetic mesh to reinforce the direct suture of the gluteus medius. The goal of this study was to assess the functional and pain outcomes in three patients treated with this reconstruction technique. Case presentation: A retrospective study was performed including 3 patients with complete and retracted ruptures of the abductor mechanism. When conservative management failed, surgical treatment was attempted. After a minimum follow-up of 12 months (mean follow-up of 18 months), all of the patients showed clinical improvement.The mean Harris Hip Score improved from 31.8 to 75.6, with an average postoperative abduction strength of 3 in the Medical Research Council muscle strength grading system, and no residual limp was noticed. The mean Visual Analogue Scale pain score decreased from 8.3 preoperatively to 1.6 postoperatively. No complications were reported. Conclusion: In conclusion, this technique demonstrates efficacy in terms of improving clinical symptoms and functional status and is a reproducible way to augment irreparable gluteus medius tears.

4.
Medicina (Kaunas) ; 58(7)2022 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-35888692

RESUMEN

Background and Objectives: Previous studies demonstrated a huge variability among surgeons when it comes to reproducing the position of an acetabular cup in total hip arthroplasty. Our main objective is to determine if orthopedic surgeons can replicate a given orientation on a pelvic model better than untrained individuals. Our secondary objective is to determine if experience has any influence on their ability for this task. Materials and Methods: A group of specialist orthopedic hip surgeons and a group of volunteers with no medical training were asked to reproduce three given (randomly generated) acetabular cup orientations (inclination and anteversion) on a pelvic model. Error was measured by means of a hip navigation system and comparisons between groups were made using the appropriate statistical methods. Results: The study included 107 individuals, 36 orthopedic surgeons and 71 untrained volunteers. The mean error among surgeons was slightly greater as regards both inclination (7.84 ± 5.53 vs. 6.70 ± 4.03) and anteversion (5.85 ± 4.52 vs. 5.48 ± 3.44), although statistical significance was not reached (p = 0.226 and p = 0.639, respectively). Similarly, although surgeons with more than 100 procedures a year obtained better results than those with less surgical experience (8.01 vs. 7.67 degrees of error in inclination and 5.83 vs. 5.87 in anteversion), this difference was not statistically significant, either (p = 0.852 and p = 0.981). Conclusions: No differences were found in the average error made by orthopedic surgeons and untrained individuals. Furthermore, the surgeons' cup orientation accuracy was not seen to improve significantly with experience.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Cirujanos Ortopédicos , Cirujanos , Acetábulo/cirugía , Humanos
5.
J Orthop Surg Res ; 16(1): 227, 2021 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-33781327

RESUMEN

BACKGROUND: To test the validity of a second-generation appropriateness system in a cohort of patients undergoing total knee arthroplasty (TKA). METHODS: We applied the RAND/UCLA Appropriateness Method to derive our second-generation system and conducted a prospective study of patients diagnosed with knee osteoarthritis in eight public hospitals in Spain. Main outcome questionnaires were the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Short-Form-12 (SF-12), and the Knee Society Score satisfaction scale (KSS), completed before and 6 months after TKA. Baseline, changes from baseline to 6 months (journey outcome), and 6-month scores (destination outcome) were compared according to appropriateness category. Percentage of patients attaining the minimal clinically important difference (MCID) and responders according to Outcome Measures in Rheumatology-Osteoarthritis Research Society (OMERACT-OARSI) criteria were also reported. RESULTS: A total of 282 patients completed baseline and 6-month questionnaires. Of these, 142 (50.4%) were classified as Appropriate, 90 (31.9%) as Uncertain, and 50 (17.7%) as Inappropriate. Patients classified as Appropriate had worse preoperative pain, function, and satisfaction (p < 0.001) and had greater improvements (i.e., journey scores) than those classified as Inappropriate (p < 0.001). At 6 months, destination scores for pain, function, or satisfaction were not significantly different across appropriateness categories. The percentage of patients meeting responder criteria (p < 0.001) and attaining MCID was statistically higher in Appropriate versus Inappropriate groups in pain (p = 0.04) and function (p = 0.004). CONCLUSIONS: The validity of our second-generation appropriateness system was generally supported. The findings highlight a critical issue in TKA healthcare: whether TKA appropriateness should be driven by the extent of improvement, by patient final state, or by both.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/clasificación , Osteoartritis de la Rodilla/cirugía , Evaluación de Resultado en la Atención de Salud/métodos , Garantía de la Calidad de Atención de Salud/métodos , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Satisfacción del Paciente , Estudios Prospectivos , Calidad de Vida , España , Encuestas y Cuestionarios , Factores de Tiempo , Resultado del Tratamiento
6.
Arthroplast Today ; 7: 167-176, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33553545

RESUMEN

BACKGROUND: The objective is to compare, by the means of finite elements analysis, the biomechanical behavior of a conventional stem of proven performance with a short stem based on the same fixation principles. METHODS: A 3D femur was modeled from CT scan data, and real bone density measures were incorporated into it. Load stresses were applied to that bone in 3 different scenarios: without prosthesis, with the conventional stem, and with the short stem. Different bone loading patterns were compared by Gruen's zones both visually and statistically using Welch's test. RESULTS: The implantation of a stem generates a certain degree of stress shielding in the surrounding bone, but the pattern of the change is very similar in the compared stem models. Although there is statistical significance (P < 0.01) in the mean stress variation in most of the Gruen's zones, the magnitude of the difference is always under 2 MPa (range: 0.01 - 1.74 MPa). CONCLUSIONS: The bone loading patterns of the traditional stem and the short stem are very similar. Although there is no evidence of a link between biomechanics and clinical outcomes, our results may suggest that theoretical advantages of short stems can be exploited without the fear of altering bone loading patterns.

7.
Injury ; 52(10): 3022-3027, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33593525

RESUMEN

BACKGROUND: The main objective of this study was to evaluate the morbidity and mortality following periprosthetic femoral fractures (PFFs) after total hip arthroplasty. The secondary objectives were to explore risk factors for mortality and compare outcomes by method of treatment. METHODS: A multicenter retrospective study was conducted (2016-2017) of all PFFs after total hip arthroplasty. We collected data on: ASA score, Charlson comorbidity index, type of fracture, method of treatment, timing of surgery, length of stay, systemic and local complications and mortality. Functional outcome was assessed in terms of preoperative and postoperative ambulatory status. Univariate and multivariate analysis were performed in the sample to identify risk factors for mortality. RESULTS: A total of 107 patients were evaluated and their mean age was 81 years old. The most common type of fracture according to the Vancouver classification was B1 (52.4% of patients), followed by B2 fractures (31.8%). The mortality rate during the first month was 9.3% and was associated with patients with ASA >3. Mortality rate in the first year was 22.3% and was associated with poorer walking ability before surgery and Charlson index ≥3. In the multivariable analysis, Charlson index ≥3 (odds ratio = 6.85) and age ≥80 years old (odds ratio=7.446) were associated with 1-year mortality. Neither complications nor mortality rate were associated with either time to surgery or method of treatment. More than half of the patients (57.9%) did not regain their prefracture walking status. Major systemic complications developed in 23.4% of the patients and major local complications in 12.1%. CONCLUSION: Despite modern surgical techniques and multidisciplinary management, this study highlights the ambulatory status impairment and high rate of complications and mortality after PFF. Although the mortality rate during the first year was similar to that observed in other studies on PFFs, we found a higher mortality rate within the first month.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Fémur , Fracturas Periprotésicas , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/efectos adversos , Fracturas del Fémur/cirugía , Humanos , Fracturas Periprotésicas/cirugía , Reoperación , Estudios Retrospectivos
8.
Injury ; 52(6): 1467-1472, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33454062

RESUMEN

INTRODUCTION: Total hip arthroplasty (THA) after femoral neck fracture (FNF) is associated with an increased risk of dislocation. The goals of our study were (1) to determine dislocation and revision rates when dual-mobility cups (DMCs) are used in these patients, (2) to analyze clinical and radiographic outcomes, survivorship, complications and mortality rate, and (3) to compare results between cemented and cementless cups. PATIENTS AND METHODS: We retrospectively reviewed patients with FNF treated using DMC-THA between 2011 and 2018. A minimum 2-year follow-up was required for clinical and radiographic assessment. The clinical outcome was assessed using the Harris Hip Score (HHS) and Merlé D´Aubigné-Postel score (MDP). Radiolucent lines, osteolysis and cup loosening were analyzed. RESULTS: We included 105 patients (105 hips) with a mean age of 75.5 years. There were no dislocations. One patient (1.0%) underwent cup revision at 39 months for aseptic cup loosening. The mean HHS and MDP were 80.5 and 14.2 respectively at a mean follow-up of 4.1 years. A higher MDP was found in patients with cementless rather than cemented cups (15.0 vs. 13.1; p = 0.006). Four patients had radiolucent lines > 1 mm, around cemented cups. At 6.8 years, estimated cup survival was 98.2% for revision for aseptic loosening and 97.3% for revision for any reason. The mortality rates were 6.7% at 1 year and 23.8% at last follow-up. CONCLUSION: Our findings suggest that using DMC in THA for FNF may prevent dislocation with a low revision rate. Cementless cups had a higher MDP than cemented cups.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Cuello Femoral , Prótesis de Cadera , Acetábulo/cirugía , Anciano , Fracturas del Cuello Femoral/diagnóstico por imagen , Fracturas del Cuello Femoral/cirugía , Estudios de Seguimiento , Humanos , Diseño de Prótesis , Falla de Prótesis , Reoperación , Estudios Retrospectivos
9.
Hip Int ; 31(1): 97-102, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31601128

RESUMEN

BACKGROUND: Cementation of polyethylene liners into well-fixed cementless metal shells has become an option during revision total hip arthroplasty (THA). We report the results of cementing a dual-mobility (DM) component into a stable acetabular shell in high-risk patients undergoing revision THA. METHODS: A single-centre series of 10 patients undergoing revision THA with a DM cup cemented into an existing well-fixed shell between 2012 and 2016 were retrospectively reviewed. Failure due to aseptic loosening or instability and implant survival at last follow-up were analysed. The average age was 79.2 years and mean follow-up was 3.5 years. Indications were recurrent hip dislocation in 8 cases and intraoperative instability with moderate abductor insufficiency in 2 cases. In cases with recurrent dislocation, the aetiology of instability was classified by Wera type. RESULTS: At the latest follow-up, Harris Hip Scores had improved from 49.3 preoperatively to 71.3 postoperatively (p = 0.098). In the 8 patients with recurrent dislocation, 4 cases (50%) had an unclear aetiology (Wera type 6), 2 (25%) abductor deficiency (Wera type 3) and 2 (25%) late polyethylene wear (type 5).Postoperative recurrent dislocation occurred in 1 hip (10%). No cases of intraprosthetic dislocation, aseptic loosening of the previous shell or dissociation at the cement-cup interface were identified. CONCLUSION: Although the follow-up of this series is short, cementation of a DM cup into a previous well-fixed socket seems to be a viable option to treat and prevent instability after revision THA, without providing constraint at the cement-cup interface.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Luxación de la Cadera , Prótesis de Cadera , Anciano , Artroplastia de Reemplazo de Cadera/efectos adversos , Cementación , Estudios de Seguimiento , Luxación de la Cadera/diagnóstico por imagen , Luxación de la Cadera/etiología , Luxación de la Cadera/cirugía , Humanos , Diseño de Prótesis , Falla de Prótesis , Reoperación , Estudios Retrospectivos
10.
Hip Int ; 31(5): 649-655, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32093495

RESUMEN

PURPOSE: 1 of the causes of groin pain after total hip arthroplasty (THA) is impingement of the iliopsoas tendon. The purpose of this study was to present our results with outside-in arthroscopic tenotomy for iliopsoas impingement after THA. METHODS: We retrospectively reviewed 12 patients treated between 2009 and 2016 with a minimum follow-up of 2 years. Anterior acetabular component prominence was measured on a true lateral hip radiograph. A transcapsular tenotomy was performed near the edge of the acetabular component through an outside-in arthroscopic approach. The primary clinical outcomes evaluated were groin pain, assessed with a visual analogue scale (VAS), and the Harris Hip Score (HHS). Secondary outcomes included strength of hip flexion, measured with the Medical Research Council (MRC) scale. RESULTS: All patients had groin pain improvement, though one patient continued to have moderate pain. The mean VAS score was significantly lower postoperatively (1.08) than preoperatively (6.2) (p < 0.001). The mean HHS improved from 58.8 (range, 37-76) to 86.1 (range, 59-98) (p = 0.001). The average postoperative MRC Scale was 4.58. The mean anterior prominence was 7.25 mm (range 3-12 mm). In patients with <10 mm of component prominence, tenotomy provided groin pain resolution in all cases (n = 8). In patients with ⩾10 mm of prominence, symptoms resolved in 3 out of 4 cases. CONCLUSIONS: Outside-in arthroscopic iliopsoas release provided a high rate of success with no complications in this study, even in patients with moderate acetabular component prominence.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Pinzamiento Femoroacetabular , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroscopía , Pinzamiento Femoroacetabular/diagnóstico por imagen , Pinzamiento Femoroacetabular/etiología , Pinzamiento Femoroacetabular/cirugía , Cadera/cirugía , Articulación de la Cadera/cirugía , Humanos , Músculos Psoas/diagnóstico por imagen , Músculos Psoas/cirugía , Estudios Retrospectivos , Tenotomía , Resultado del Tratamiento
11.
Eur J Orthop Surg Traumatol ; 30(2): 281-289, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31617019

RESUMEN

PURPOSE: Demand for revision total hip arthroplasty (THA) is growing, and this type of surgery remains challenging for orthopedic surgeons. Our objectives were to assess clinical and radiographic outcomes, survivorship and complications with the SLR-Plus stem in revision THA. METHODS: We retrospectively reviewed 65 patients (66 hips) who had undergone revision THA with the SLR-Plus stem between 2008 and 2015 at two medical institutions with a minimum 2-year follow-up. The clinical outcome was assessed using the Harris hip score and the Merlé D'Aubigné score preoperatively and at final follow-up. A postoperative visual analogue scale for pain and satisfaction was also used. Radiographic subsidence and fixation, Kaplan-Meier survivorship and complications were analyzed. RESULTS: The mean follow-up was 4.1 years (SD 2.1). Aseptic loosening (57.6%) was the main indication for surgery. The mean Harris Hip Score improved from 50.4 (SD 16.5) to 83 (SD 12.7) (p < 0.001) and mean Merlé D'Aubigné score improved from 9.5 (SD 2.7) to 14.3 (SD 2.2) (p < 0.001). A total of 98.4% of stems showed radiographically stable fixation. No aseptic loosening of the stem was seen. Radiolucent lines > 1 mm were observed in 33.3% of stems. Three stems were re-revised: two due to infection and one due to instability. At 7 years, estimated stem survival was 95.5% for revision for any reason and 100% for revision for aseptic loosening. Dislocation occurred in 7.6% of hips. CONCLUSION: We have shown significant clinical improvement, 98.4% of stable fixation and 100% stem survivorship for aseptic loosening in revision THA with the SLR-Plus stem.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Reoperación , Anciano , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/instrumentación , Artroplastia de Reemplazo de Cadera/estadística & datos numéricos , Femenino , Prótesis de Cadera/efectos adversos , Humanos , Estimación de Kaplan-Meier , Masculino , Diseño de Prótesis , Falla de Prótesis , Reoperación/efectos adversos , Reoperación/instrumentación , Reoperación/métodos , Estudios Retrospectivos , Resultado del Tratamiento
12.
Hip Pelvis ; 31(3): 158-165, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31501765

RESUMEN

PURPOSE: Debridement, antibiotics and implant retention (DAIR) is commonly performed and widely accepted for the treatment of acute infections following hip arthroplasty. The aims of this study were to: i) determine the DAIR success rate in treating acute postoperative and hematogenous periprosthetic infections of the hip at a tertiary hospital, ii) identify possible outcome predictors, and iii) analyze clinical and radiological outcomes. MATERIALS AND METHODS: We retrospectively reviewed cases of acute postoperative (≤3 months from index procedure) and hematogenous periprosthetic infections following total hip arthroplasty treated with DAIR at our hospital between 2004 and 2015. Overall, 26 hips (25 patients) were included in the study, with a mean age of 72.5 years (standard deviation [SD], 9.4). The mean follow-up was 48.5 months (SD, 43.7). Several variables (e.g., patient characteristics, infection type, surgery parameters) were examined to evaluate their influence on outcomes; functional and radiographic outcomes were assessed. RESULTS: The overall success rate of DAIR was 26.9%. The male sex was associated with treatment failure (P=0.005) and debridement performed by a surgeon in hip unit with success (P=0.028). DAIR failure increased in patients with chronic pulmonary disease (P=0.059) and steroid therapy (P=0.062). Symptom duration of <11 days until DAIR yielded a better infection eradication rate (P=0.068). The mean postoperative Harris Hip Score was 74.2 (SD, 16.6). CONCLUSION: DAIR, despite being used frequently, had a high failure rate in our series. Outcomes improved if an experienced hip arthroplasty surgeon performed the surgery. Patient comorbidities and symptom duration should be considered for decision-making.

13.
J Orthop Surg Res ; 14(1): 278, 2019 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-31462250

RESUMEN

BACKGROUND: Debridement and irrigation with prosthetic retention followed by antibiotic therapy (DAIR) is one of the treatments of choice in acute infections after a total knee arthroplasty. However, the success rate varies widely in the literature, depending on several factors such as comorbidities of the patient, duration of infection, and microorganisms involved. The goal of this study was to assess the outcomes of this therapeutic option and to identify possible predictors of the result. METHODS: We retrospectively reviewed cases of acute postoperative (≤ 3 months from index procedure) and acute hematogenous periprosthetic knee infections treated with DAIR at our hospital between 2004 and 2016. Overall, 26 knees were included, with a mean age of 73.4 years. Several variables related to patient characteristics, infection type, and surgery were examined to evaluate their influence on outcome, and functional and radiographic outcome were assessed. The mean follow-up was 41 months. A descriptive analysis was carried out on the collected data, and a univariate analysis was performed with the objective of searching for influential factors in the resolution of the infection using the chi-square nonparametric test in the case of the categorical variables and the Wilcoxon test for the continuous ones. Moreover, univariate cox regression analysis was performed. RESULTS: The overall success rate was 77% at the last follow-up, recording a significantly greater cure in acute infections (93% acute vs 58% acute hematogenous, p = 0.03). The infections in which the Staphylococcus aureus was isolated had a significantly lower cure rate, with only 33% of success, compared to 82% of the non-aureus microorganisms (p <  0.05). CONCLUSIONS: The present study shows a considerable cure rate in the treatment of acute knee infections through DAIR, although patient comorbidities, type of infection, and causative microorganism should be considered for decision-making.


Asunto(s)
Antibacterianos/administración & dosificación , Artroplastia de Reemplazo de Rodilla/efectos adversos , Desbridamiento/métodos , Retención de la Prótesis/métodos , Infecciones Relacionadas con Prótesis/terapia , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla/tendencias , Desbridamiento/tendencias , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Retención de la Prótesis/tendencias , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Resultado del Tratamiento
14.
Hip Int ; 29(2): 184-190, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29716387

RESUMEN

INTRODUCTION:: The objective was to evaluate clinical and radiological outcomes of Vancouver B2 and B3 periprosthetic femoral fractures in patients older than 65 years treated at our institution from 2000 to 2014. We compared the most common methods of fixation: a modular tapered rectangular titanium stem versus a monoblock tapered stem. METHODS:: A retrospective review was performed with a minimum follow-up time of 2 years. Patient mobility in the period prior to the fracture and after fracture healing and functional results was assessed according to the Harris Hip Score. RESULTS:: A total of 43 Vancouver B2 and B3 periprosthetic fractures fulfilled the inclusion criteria (31 type B2 and 13 type B3). The mean age was 78 years old (66-88 years). The mean follow-up time was 5 years (range 2-12 years). A Wagner stem was used in 19 patients and a modular rectangular stem was implanted in 24 patients. Although fracture union was achieved in 93% of the cases, the mean Harris Hip Score was 73 (34-87) and 41.9% of the patients did not return to their previous ambulatory levels ( p = 0.0049). Dislocation was the most common complication (16.3%). We have found association ( p = 0.07) between subsidence with a mean of 4.14 mm and dislocation. No difference was observed between B2 and B3 fractures or between modular and monoblock stems. DISCUSSION:: Although we reported good results of fracture healing, there were functional impairment and a high rate of complications, especially dislocation, in Vancouver B2 and B3 periprosthetic fractures in elderly patients.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Fracturas del Fémur/cirugía , Prótesis de Cadera/efectos adversos , Fracturas Periprotésicas/etiología , Fracturas Periprotésicas/cirugía , Complicaciones Posoperatorias/cirugía , Factores de Edad , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/métodos , Femenino , Fracturas del Fémur/diagnóstico por imagen , Fracturas del Fémur/etiología , Curación de Fractura , Humanos , Masculino , Fracturas Periprotésicas/diagnóstico por imagen , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/etiología , Diseño de Prótesis , Radiografía , Reoperación , Estudios Retrospectivos , Titanio , Resultado del Tratamiento
15.
Eur J Orthop Surg Traumatol ; 28(7): 1327-1334, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29696415

RESUMEN

INTRODUCTION: The objective of this study was to analyse results achieved with the S-ROM modular stem in revision surgery. MATERIALS AND METHODS: A retrospective observational study was conducted from 2007 to 2015 including 51 patients who had a follow-up of ≥ 2 years and complete medical history. The mean age was 66.5 years old (34-87). The main reason for revision was aseptic loosening (38 cases, 74.5%), followed by infection (10, 19.6%), instability (2, 3.9%) and an adverse reaction associated with a metal-on-metal hip implant (1, 2%). Using the Paprosky classification, there were 22 cases of type I (43.1%), 27 of type II (52.9%) and 2 of type IIIA (4%). At the end of the follow-up, radiological parameters were assessed using Engh's criteria. Pre- and postoperative clinical status was assessed using the Harris Hip Score, a visual analogue scale and the Merle D'Aubigné score. RESULTS: The mean follow-up period was 5.7 years (2-10). The mean Harris Hip Score improved from 45.5 points (22-65) to 85.8 (55-100) (p < 0.001), and the final mean Merle D'Aubigné scores were 5.2, 4.6 and 5.6 for pain, ability to walk and mobility, respectively. Osseointegration was confirmed in all except one patient with fibrous non-union. No aseptic loosening has been recorded. Postoperative complications were deep infection in four cases (7.8%) and dislocation in three (5.9%). CONCLUSION: This study indicates good medium-term outcomes using a modular hip replacement system with porous-coated proximal sleeves in revision surgery in patients with Paprosky type I and II defects.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/instrumentación , Prótesis de Cadera , Diseño de Prótesis , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Prótesis de Cadera/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Falla de Prótesis , Reoperación/efectos adversos , Reoperación/métodos , Estudios Retrospectivos , Resultado del Tratamiento
16.
Hip Int ; 27(5): e7-e10, 2017 Sep 19.
Artículo en Inglés | MEDLINE | ID: mdl-28885649

RESUMEN

INTRODUCTION: Stemmed acetabular components are used in patients undergoing revision total hip arthroplasty in cases with major acetabular defects or pelvic discontinuity. Conflicting results relating to the survival of the component, and complication rates are reported in the literature. We present a case of L5 radiculopathy secondary to proximal migration of this device. CASE DESCRIPTION: A 79-year-old man was admitted to our department in 2012 with increasing pain and paresthesias, initially diagnosed as left L5 radiculopathy. In 2002, he had undergone revision surgery due to aseptic loosening of the acetabular component with a stemmed acetabular cup. Radiological findings were severe osteolysis around the acetabular cup with proximal migration. MRI showed osteolysis involving the left L5/S1 facet joint and evidence of soft tissue in the left foramina encasing the L5 radicular nerve. Nerve conduction and electromyography studies revealed chronic L5 radiculopathy. DISCUSSIONS: This case report illustrates the importance of considering acetabular loosening in a patient presenting with radicular symptoms. If a stemmed acetabular cup is chosen for an acetabular reconstruction, careful surgical technique should be employed in order to achieve durable fixation. If the patient has pelvic discontinuity, other options of reconstruction have showed better outcomes in the literature.


Asunto(s)
Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/efectos adversos , Prótesis de Cadera/efectos adversos , Radiculopatía/diagnóstico , Acetábulo/diagnóstico por imagen , Anciano , Humanos , Vértebras Lumbares , Masculino , Diseño de Prótesis , Falla de Prótesis , Radiculopatía/etiología , Reoperación , Tomografía Computarizada por Rayos X
17.
Orthopedics ; 40(1): 38-42, 2017 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-27648577

RESUMEN

Tear of the quadriceps tendon after revision or primary total knee arthroplasty is a rare complication, but when it occurs, this injury has serious functional consequences. In complete tears, the outcome of direct repair is unpredictable, and several authors recommend that the suture should be reinforced. Several techniques have been described, including the use of autografts, allografts, and synthetic mesh. The goal of this study was to assess the outcomes of a reconstruction technique augmented with synthetic mesh. A retrospective study was performed involving 3 patients who had chronic partial quadriceps tendon tear after total knee revision. In 2 cases, proximal quadriceps release was performed. When conservative management failed, surgical reconstruction with suture reinforced with synthetic mesh was attempted. The knee was immobilized in full extension for 6 weeks after the surgical procedure. A minimum follow-up of 12 months was required to assess results. All reconstructions showed clinical success at a mean follow-up of 19 months. Mean Knee Society Score improved from 55.7 to 87.3, with average postoperative extensor lag of 3.3° (range, 0°-10°). The mean visual analog scale pain score was 2.3 (range, 0-4). No complications were reported. Synthetic mesh has previously been shown to be an effective treatment for patellar tendon repairs after total knee replacement, but there have been few articles on quadriceps rupture. Surgical reconstruction with synthetic mesh is a viable option that provides good functional outcomes in chronic quadriceps tendon rupture after total knee arthroplasty. [Orthopedics. 2017; 40(1):38-42.].


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Ligamento Rotuliano/lesiones , Procedimientos de Cirugía Plástica/métodos , Mallas Quirúrgicas/efectos adversos , Traumatismos de los Tendones/etiología , Anciano , Femenino , Humanos , Articulación de la Rodilla/cirugía , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/cirugía , Ligamento Rotuliano/cirugía , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/cirugía , Prótesis e Implantes/efectos adversos , Músculo Cuádriceps/lesiones , Músculo Cuádriceps/cirugía , Estudios Retrospectivos , Rotura Espontánea/etiología , Rotura Espontánea/cirugía , Suturas/efectos adversos , Traumatismos de los Tendones/cirugía , Resultado del Tratamiento
18.
Injury ; 46(2): 292-8, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25085599

RESUMEN

BACKGROUND: The aim of this study was to determine the functional and radiological results of the treatment of periprosthetic femoral fractures. MATERIALS AND METHODS: A review was performed of all periprosthetic femur fractures after a total hip arthroplasty (THA) or hemiarthroplasty (HA) treated at our institution from 1995 to 2011. Functional outcome was assessed in terms of the Harris Hip Score and ambulatory status. Radiological findings were classified using Beals and Tower's criteria. RESULTS: A total of 59 periprosthetic fractures were identified in 58 patients. The mean age of patients was 79 years old and the mean follow-up time was 33.6 months. Local risk factors were identified in 71% of the patients, principally osteoporosis (59%), followed by osteolysis (24%) and loosening of the stem (19%). In the multivariable analysis, the presence of local risk factors was associated with worsening of patients' ambulatory status. According to the Vancouver classification, there were 8 type A, 46 type B and 5 type C fractures. Of the type B fractures 24 were B1, 14 were B2 and 8 were B3. Fracture union was achieved in 54 fractures, with a mean union time of 6 months. Applying Beals and Tower's criteria, radiological results were excellent in 20 patients (34%), good in 22 (37%), and poor in 17 (29%). None of the patients improved their ability to walk after these fractures and 31 patients (52%) did not regain their prefracture walking status. The mean Harris Hip Score postoperatively was 67.9. There were major or minor complications in 33 patients (56%) and 11 patients (19%) required further operations. CONCLUSION: Although this study shows good radiological results following methods of treatment in accordance with the Vancouver classification, there was marked functional deterioration in many patients and a high rate of complications. Local risk factors were associated with poorer ambulatory status.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Fracturas del Fémur/diagnóstico por imagen , Fijación Interna de Fracturas/métodos , Fracturas Periprotésicas/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Femenino , Fracturas del Fémur/fisiopatología , Fracturas del Fémur/prevención & control , Fracturas del Fémur/cirugía , Estudios de Seguimiento , Curación de Fractura , Humanos , Masculino , Fracturas Periprotésicas/fisiopatología , Fracturas Periprotésicas/prevención & control , Fracturas Periprotésicas/cirugía , Radiografía , Reoperación/estadística & datos numéricos , Estudios Retrospectivos , Medición de Riesgo , España/epidemiología , Factores de Tiempo , Insuficiencia del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...