Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Immunohematology ; 18(1): 19-22, 2002.
Artículo en Inglés | MEDLINE | ID: mdl-15373571

RESUMEN

An 18-month-old male was admitted to a hospital with a hemoglobin of 4.1 g/dL and a reticulocyte count of 53 percent. There was no history of prior transfusion. Serologic evaluation revealed the presence of both a positive direct antiglobulin test (DAT) and an indirect antiglobulin test (IAT). The patient's red blood cells (RBCs) typed as group A, C-D-E-c+e+ (cde/cde). Evaluation of the IAT revealed the presence of anti-c and anti-E. All other major antibodies were ruled out. Upon adsorption of the patient's serum with ficin-treated Cde/Cde RBCs, both antibody specificities were adsorbed; however, the antibodies were not adsorbed with native (untreated) Cde/Cde RBCs. Furthermore, the autoantibody was not adsorbed by Rhnull cells, thereby suggesting Rh specificity. The serum was incompatible with cde/cde RBCs and compatible with Cde/Cde RBCs. The patient was successfully transfused with Cde/Cde RBCs followed by resolution of his anemia, as evidenced by an increased and stable hemoglobin. It was concluded that the autoantibody had mimicking anti-c and -E specificities. This is a report of an unusual case of autoimmune hemolytic anemia because the Rh autoantibody appeared to have dual mimicking specificities, and the patient's RBCs were antigen negative for one of the antibody specificities, i.e., anti-E.

2.
Ann Thorac Surg ; 71(6): 1839-44, 2001 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-11426757

RESUMEN

BACKGROUND: Efforts to predict mortality in bridge to cardiac transplant patients have concentrated on preventricular assist device (VAD) status. To more fully identify factors influencing survival to transplant, we reviewed the preoperative and postoperative VAD courses of 105 bridge to transplant patients. METHODS: Sixty-four parameters (34 pre-VAD, 30 post-VAD), including hemodynamics, complications, and evaluations of major organ function were examined and analyzed. RESULTS: Thirty-three patients (31%) died on VADs and 72 were transplanted. There were two posttransplant operative deaths (3%). By univariate analysis 23 of 64 factors were significant. These 23 factors were entered into a stepwise logistic regression analysis to identify predictors of survival to transplant. Four factors, including pre-VAD intubation (p < 0.005), cardiopulmonary bypass (CPB) time during VAD insertion (p < 0.0001), mean pulmonary artery pressure (first postoperative day after VAD) (p < 0.0002), and highest post-VAD creatinine (p < 0.01) were independent predictors of transplantation. CONCLUSIONS: Other than the need for intubation, pre-VAD variables were of little value in predicting survival to transplant. Problems during VAD insertion (long CPB time) and post-VAD renal insufficiency were independent predictors. Severe complications that developed during the interval of VAD support, including cerebrovascular accident, bleeding and infection, were surprisingly not predictors for transplantation.


Asunto(s)
Trasplante de Corazón/mortalidad , Corazón Auxiliar , Análisis Actuarial , Adolescente , Adulto , Anciano , Causas de Muerte , Niño , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/mortalidad , Estudios Prospectivos , Análisis de Regresión , Medición de Riesgo , Tasa de Supervivencia
3.
J Thorac Cardiovasc Surg ; 119(5): 1015-20, 2000 May.
Artículo en Inglés | MEDLINE | ID: mdl-10788824

RESUMEN

OBJECTIVE: Improving results with ventricular assist devices have led to their wider clinical application. Centers can stabilize, support, and wean or transfer patients to regional transplant centers. METHODS: Prospectively collected data were reviewed to evaluate the clinical results of patients transferred to our institution while receiving advanced mechanical circulatory support. RESULTS: Since 1993, 16 patients were accepted while receiving support with either extracorporeal membrane oxygenation or a ventricular assist device. The 10 male and 6 female patients ranged in age from 9 to 60 years (mean, 42.1 years). Thirteen had had cardiac surgical procedures, two had acute myocardial infarctions, and one had myocarditis. The distance transported ranged from 0.2 to 309 miles (mean, 132 miles). Twelve patients were transferred by ground, and 4 were transported by air. Seven patients were originally supported with extracorporeal membrane oxygenation, 6 with centrifugal pumps, and 3 with ABIOMED ventricular assist devices (ABIOMED, Inc, Danvers, Mass). Two patients had clinical complications during transfer, and one had a cerebrovascular accident, recovered, was weaned, and survived. A second patient had hemodynamic deterioration. There were no technical complications associated with transport. Six patients were left on the original support device; 3 of the 6 were weaned and survived, and 3 died during support. The 10 remaining patients were switched to other ventricular assist devices: 9 patients to Thoratec devices (Thoratec Laboratories, Pleasanton, Calif) and 1 patient to a Novacor device (Baxter Healthcare Corp, Novacor Division, Oakland, Calif). Six of the 10 patients underwent transplantation and survived. Four patients died while being supported by the devices. Nine patients were discharged, with 1 late death at 29 months. Eight patients are alive 4 to 65 months after discharge. CONCLUSIONS: These data suggest that patients receiving advanced support can be moved between clinical centers with acceptable risks. Because 33% of the survivors were weaned, transplantation is not required for survival.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Corazón Auxiliar , Transferencia de Pacientes , Adolescente , Adulto , Enfermedades Cardiovasculares/mortalidad , Enfermedades Cardiovasculares/terapia , Niño , Unidades de Cuidados Coronarios , Femenino , Hospitales Universitarios , Humanos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Riesgo , Tasa de Supervivencia
4.
Ann Thorac Surg ; 67(5): 1233-8; discussion 1238-9, 1999 May.
Artículo en Inglés | MEDLINE | ID: mdl-10355389

RESUMEN

BACKGROUND: Ventricular assist devices (VADs) have gained wider acceptance due to refinements in patient selection and management and device availability. METHODS: To evaluate early and late results, we reviewed our first 111 patients with the Thoratec VAD. RESULTS: Forty-four patients were supported for myocardial recovery. The mean age in the recovery group was 51.9 years. There were 18 left VADs (LVADs), 17 biventricular VADs (BVADs), and nine right VADs (RVADs). Complications included bleeding in 20 patients (45%) and device-related infection in 1 patient (2%). Nineteen were weaned from the VAD, with 12 survivors. Sixty-seven patients were supported as a bridge to cardiac transplantation. The mean age was 41.5 years. There were 39 LVADs and 28 BVADs. Complications included bleeding in 21 patients (31%) and device-related infection in 12 (18%). Three patients were weaned and 39 patients were transplanted from the assist device, for a total of 42 bridge survivors. Device-related thromboembolism occurred in 9 patients (8.1%), 7 of whom were bridge to transplantation. The duration of VAD support ranged from 0.1 to 27 days (mean 4.5 days) in the recovery group and 0.2 to 184 days (mean 40.7 days) in the bridge to transplantation group. The 10-year actuarial survival was 16% for the recovery group, 22%, for the bridge group, and 33% for transplanted patients. CONCLUSIONS: Despite advances, VAD support remains associated with significant morbidity and operative mortality.


Asunto(s)
Corazón Auxiliar , Adolescente , Adulto , Anciano , Femenino , Trasplante de Corazón , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/terapia , Complicaciones Posoperatorias , Estudios Retrospectivos , Análisis de Supervivencia , Resultado del Tratamiento
5.
Ann Thorac Surg ; 68(6): 2248-51, 1999 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-10617011

RESUMEN

BACKGROUND: Due to potential thromboembolic complications, mechanical valves within the native heart are often considered contraindications to ventricular assist device (VAD) support. METHODS: A retrospective review of VAD cases between June 1982 and March 1998 showed 8 patients with mechanical valves who were supported with Thoratec (Pleasanton, CA) VADs. RESULTS: There were 6 males and 2 females ranging in age from 20 to 69 years (mean 49.8+/-5.6). Four patients were supported when they could not be weaned from cardiopulmonary bypass after reparative procedures and were thought to have reversible injuries. Four patients were supported as a bridge-to-cardiac transplantation. Two patients had mechanical mitral valves, 2 had aortic valve replacements, 1 had an aortic homograft and mechanical mitral valve, 2 had mechanical aortic and mitral prosthesis, and 1 patient had aortic, mitral, and tricuspid valves. The types of valvular prostheses were St. Jude (5 patients) and Bjork-Shiley (3 patients). Duration of support ranged from 3.0 to 150 days (mean 34 days). Four patients were supported with biventricular assist devices and 4 had left VADs. Dextran and intravenous heparin anticoagulation were used in the shorter duration patients, with warfarin being used in the bridge patients. One patient received warfarin and aspirin. At the time of autopsy or device removal, only 1 of the 12 mechanical intracardiac valves showed any evidence of thrombosis, including the aortic valves in 2 patients supported for 2 and 5 months. There were no clinical thromboembolic events. Four patients (50%) were discharged (1 weaned, 3 transplanted). CONCLUSIONS: The 50% (4 of 8) survival rate compares favorably with the 44% (41 of 92) overall survival rate for our Thoratec patients (bridge plus recovery) who did not have mechanical prosthetic valves. These data suggest that patients with mechanical intracardiac valves can be supported for short durations with some additional risk, which is yet to be determined.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Corazón Auxiliar , Adulto , Anciano , Anticoagulantes/administración & dosificación , Aspirina/administración & dosificación , Contraindicaciones , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Heparina/administración & dosificación , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Tromboembolia/etiología , Tromboembolia/prevención & control
6.
Res Q Exerc Sport ; 70(4): 361-8, 1999 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-10797894

RESUMEN

Five women and 5 men were studied to examine the effects of submaximal exercise on thermoregulatory and hemodynamic variables during recovery in two environments: (a) control (C), 22 degrees C, 33% rh; and (b) hot humid (H), 32 degrees C. The participants exercised on a cycle ergometer at 60% of peak oxygen consumption for 35 min prior to 90 min of seated recovery. Sessions were identical, except for environment. Variables evaluated (p < .05) were: core temperature (TR), mean skin temperature (Ts), sweat rate (SR), heart rate (HR), stroke index (SI), cardiac index (CI), forearm blood flow (FBF), systolic blood pressure (SBP), and diastolic blood pressure (DBP). Men and women exhibited similar patterns of TR, Ts, and SR in both environments. Ts and SR (collapsed means for gender) were higher in the H than in the C. DBP was higher in men than in women throughout recovery in both environments. With combined means for gender, HR was higher in the H than in the C. CI, SI, FBF, and SBP were similar in both environments and returned to baseline within 15 min into recovery. These data suggest that heat dissipation during extended recovery was accomplished with similar contributions of cutaneous vasodilation and sweating in M and F. Furthermore, the moderate exercise level did not influence hemodynamics beyond 15 min of recovery in either environment.


Asunto(s)
Regulación de la Temperatura Corporal/fisiología , Hemodinámica/fisiología , Esfuerzo Físico/fisiología , Adolescente , Adulto , Ciclismo/fisiología , Presión Sanguínea/fisiología , Temperatura Corporal/fisiología , Gasto Cardíaco/fisiología , Femenino , Antebrazo/irrigación sanguínea , Frecuencia Cardíaca/fisiología , Calor , Humanos , Humedad , Masculino , Consumo de Oxígeno/fisiología , Flujo Sanguíneo Regional/fisiología , Factores Sexuales , Piel/irrigación sanguínea , Temperatura Cutánea/fisiología , Volumen Sistólico/fisiología , Sudoración/fisiología , Temperatura , Vasodilatación/fisiología
7.
Ann Thorac Surg ; 65(3): 839-41, 1998 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-9527230

RESUMEN

Left ventricular assist devices are frequently used to bridge patients to cardiac transplantation. As this experience grows, new and unanticipated complications will occur. This report describes a 50-year-old man with ischemic cardiomyopathy being bridged to cardiac transplantation who suffered an acute right ventricular infarction during the interval of support.


Asunto(s)
Corazón Auxiliar , Infarto del Miocardio/etiología , Resultado Fatal , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Persona de Mediana Edad
8.
Am J Crit Care ; 6(5): 355-62, 1997 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-9283672

RESUMEN

Improvements in technology and in the selection, care, and treatment of patients have led to wider clinical use of mechanical circulatory support. Considerable progress has been made with the use of left ventricular assist devices. Patients are currently maintained in outpatient facilities until a donor heart becomes available; recently, left ventricular assist devices have started to be used as permanent implants. This article outlines the steps that are taken to prepare the patient, the patient's family, and the medical staff for discharge from the hospital of a patient supported with a left ventricular assist device. Extensive technical and clinical training of the primary caregiver and the patient is required to prepare for discharge from the hospital. Data are rapidly accumulating that show that left ventricular assist devices are safe and efficacious for outpatient use. Similar success is expected in clinical trials of permanent left ventricular assist devices, suggesting that many more patients will benefit from this technology in the future.


Asunto(s)
Corazón Auxiliar , Alta del Paciente , Educación del Paciente como Asunto , Humanos , Atención de Enfermería , Servicio Ambulatorio en Hospital , Grupo de Atención al Paciente
9.
Ann Thorac Surg ; 61(6): 1693-7; discussion 1697-8, 1996 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-8651769

RESUMEN

BACKGROUND: Management of asymptomatic mild aortic stenosis at the time of coronary artery bypass grafting (CABG) remains controversial. We have retrospectively analyzed a cohort of patients requiring aortic valve replacement (AVR) subsequent to CABG and compared their operative morbidity and mortality with that of a group receiving CABG and AVR simultaneously at the first operation. METHODS: Analysis is drawn from 28 patients who required AVR 8 +/- 4 years subsequent to CABG (group A) and 175 patients receiving AVR along with CABG at the primary operation (group B). Groups were similar with respect to age, sex, risk factors for cardiac disease, extent of coronary artery disease, left ventricular function, New York Heart Association class, aortic valve area, number of grafts, and size of prosthesis inserted. RESULTS: Patients having AVR subsequent to CABG had a significantly prolonged aortic cross-clamp time and global myocardial ischemic time and incurred a twofold increase in operative mortality. The actuarial survival at 10 years was not significantly different between cohorts. In the 28 patients in group A, the aortic valve area during the period between operations decreased 0.05 mm2/y. CONCLUSIONS: The operative mortality and morbidity of a second operation for AVR is high, but there is no significant difference in survival at 10 years. In at least a portion of patients having mild aortic stenosis at the time of CABG there will be progression of the stenosis necessitating reoperation at a later date.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Puente de Arteria Coronaria , Análisis Actuarial , Anciano , Válvula Aórtica/patología , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/patología , Puente Cardiopulmonar , Estudios de Cohortes , Puente de Arteria Coronaria/efectos adversos , Puente de Arteria Coronaria/métodos , Enfermedad Coronaria/patología , Enfermedad Coronaria/cirugía , Progresión de la Enfermedad , Femenino , Prótesis Valvulares Cardíacas , Humanos , Masculino , Isquemia Miocárdica/fisiopatología , Complicaciones Posoperatorias , Diseño de Prótesis , Reoperación , Estudios Retrospectivos , Factores de Riesgo , Tasa de Supervivencia , Factores de Tiempo , Función Ventricular Izquierda
11.
Crit Care Nurs Clin North Am ; 7(2): 249-58, 1995 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-7619367

RESUMEN

This article provides a brief overview of the ventricular assist devices (VADs) available for patients with severe ventricular failure. The history of VAD development and clinical results in the adult and pediatric population are reviewed. Because the VAD role is expanding, nursing implications and a critical analysis of the growing economic concerns regarding their use are discussed.


Asunto(s)
Cuidados Críticos , Corazón Auxiliar , Cuidados Críticos/métodos , Cuidados Críticos/tendencias , Corazón Auxiliar/efectos adversos , Corazón Auxiliar/normas , Humanos
12.
Am J Crit Care ; 4(3): 204-9; quiz 210-1, 1995 May.
Artículo en Inglés | MEDLINE | ID: mdl-7787914

RESUMEN

Improvements in technology, patient selection, and patient management have led to a wider clinical application of mechanical circulatory support. Critically ill patients often develop multiorgan ischemia and are prone to multiple complications. Despite these advances, infection is a common and sometimes lethal complication of support with ventricular assist devices. This article provides guidelines for the prevention and management of infection in patients who require such support.


Asunto(s)
Trasplante de Corazón/enfermería , Corazón Auxiliar/efectos adversos , Infecciones/etiología , Adolescente , Adulto , Anciano , Antibacterianos/administración & dosificación , Antibacterianos/uso terapéutico , Vendajes , Niño , Femenino , Humanos , Control de Infecciones/métodos , Masculino , Persona de Mediana Edad , Atención de Enfermería/métodos , Factores de Riesgo , Irrigación Terapéutica
13.
Ann Thorac Surg ; 59(5): 1113-8; discussion 1119, 1995 May.
Artículo en Inglés | MEDLINE | ID: mdl-7733706

RESUMEN

To define better the performance of the bileaflet St. Jude and the tilting-disc Medtronic-Hall valves, we retrospectively analyzed 122 patients (St. Jude, 80 patients; Medtronic-Hall, 42 patients) who received simultaneous aortic and mitral replacement from May 1984 until June 1994. The two groups were not different with respect to preoperative clinical and hemodynamic parameters and New York Heart Association functional class. The hospital mortality and late mortality were not significantly different. Risk analysis identified advanced age and previous myocardial revascularization as predictors of operative death. Follow-up was complete in 96 of 103 hospital survivors (93%) and was similar in both groups. The actuarial survival, linearized rates of valve-related complications, and actuarial freedom from valve-related complications were similar in both cohorts. The presence of coronary artery disease negatively influenced the actuarial survival after simultaneous aortic and mitral valve replacement. Postoperative New York Heart Association functional class was not significantly different in either group. These data indicate that the Medtronic-Hall and St. Jude prostheses are not significantly different with respect to their clinical performance and valve-related complications for simultaneous double-valve replacement.


Asunto(s)
Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Válvula Mitral/cirugía , Puente de Arteria Coronaria , Endocarditis Bacteriana/etiología , Femenino , Prótesis Valvulares Cardíacas/efectos adversos , Prótesis Valvulares Cardíacas/mortalidad , Hemorragia/etiología , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Tasa de Supervivencia , Tromboembolia/etiología
14.
Ann Thorac Surg ; 58(4): 1142-5, 1994 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-7944767

RESUMEN

Patient selection is considered one of the most important factors influencing success in bridge to transplant procedures. However, to date it has been difficult to identify predictors of mortality in this population using univariate or multivariate analysis. In 1988, we developed a scoring system using 21 clinical variables that could be calculated rapidly at the bedside while evaluating potential candidates. Points were designated to these variables using a scale of 1 to 3, 1 having the least adverse effect on survival and 3 the most. Patients received a value of 0 for each variable that did not apply. This scoring system was used in a retrospective analysis for 15 bridge to transplant patients. The results showed a significant difference (p < 0.003) between the 8 survivors (mean score, 5.75 +/- 2.19) and the 7 nonsurvivors (mean score, 11.71 +/- 3.45). Since 1989, we have prospectively calculated the scores in an additional 27 patients. Based on the score, all 42 patients were divided into three groups: group I had scores of 1 to 5; group II, 6 to 10; and group III, 11 to 16. The mean score for group I (16 patients) was 3.69 +/- 1.25. All group I patients survived. Group II patients (n = 15) had a mean score of 7.87 +/- 1.36 and a survival rate of 53%. The mean score for group III (n = 11) was 13 +/- 1.73. Thirty-six percent of these patients survived. Comparison of survival and mean scores among the three groups was statistically significant (p < 0.0001).(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Trasplante de Corazón/mortalidad , Corazón Auxiliar , Selección de Paciente , Adolescente , Adulto , Anciano , Niño , Femenino , Hospitales Universitarios , Humanos , Masculino , Persona de Mediana Edad , Missouri , Estudios Prospectivos , Estudios Retrospectivos , Medición de Riesgo , Tasa de Supervivencia
15.
J Cardiovasc Nurs ; 8(2): 1-12; quiz 13-5, 1994 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-8182411

RESUMEN

Considerable progress has been made over the past several decades in development of ventricular assist device (VAD) technology. Initially, failure to wean from cardiopulmonary bypass was the primary indication for VAD support. However, VAD role has expanded to include patients with ventricular failure due to myocardial infarction and patients awaiting cardiac transplantation. A greater number of nurses, both in the intensive care and general floors, are required to care for patients supported with VADs. Therefore, a self-study guide was developed to facilitate learning. Heart failure physiology, mechanical device descriptions, patient selection, potential complications, and nursing care of patients who require VAD support are reviewed.


Asunto(s)
Insuficiencia Cardíaca/cirugía , Corazón Auxiliar , Planificación de Atención al Paciente , Choque Cardiogénico/cirugía , Vendajes , Cuidados Críticos , Insuficiencia Cardíaca/enfermería , Insuficiencia Cardíaca/fisiopatología , Corazón Auxiliar/efectos adversos , Corazón Auxiliar/clasificación , Humanos , Instrucciones Programadas como Asunto , Choque Cardiogénico/enfermería , Choque Cardiogénico/fisiopatología
16.
Am J Crit Care ; 2(6): 478-86; quiz 487-8, 1993 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-8275154

RESUMEN

Conventional therapy in the management of adult respiratory distress syndrome is often associated with an increased mortality rate. Several methods to improve survival in patients with severe respiratory insufficiency are under evaluation. One recently developed method of treatment is an implantable intravascular oxygenator, which provides supplemental gas exchange for failing lungs. This device can provide temporary ventilatory support in patients with acute, potentially reversible respiratory insufficiency. Reduction in ventilator settings such as airway pressure, oxygen concentration, positive end-expiratory pressure and minute volume can be achieved, decreasing the likelihood of oxygen toxicity and barotrauma. Success of the intravascular oxygenator in adult respiratory distress syndrome is dependent in part on critical care staff expertise. Therefore, a thorough understanding of the operation of this device and its role in acute respiratory failure is necessary for optimal care.


Asunto(s)
Oxigenadores , Síndrome de Dificultad Respiratoria/enfermería , Adulto , Humanos , Masculino , Diagnóstico de Enfermería , Venas Renales , Síndrome de Dificultad Respiratoria/terapia , Vena Cava Superior
17.
Nucl Med Biol ; 20(3): 269-78, 1993 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-8485486

RESUMEN

[18F]-N-(p-nitrobenzyl)spiperone, [18F]PNBS, was prepared and its in vivo uptake in rat brain was measured. A temporal increase in striatum:cerebellum ratio and frontal cortex:cerebellum (FC:Cb) ratio was observed. Blocking studies suggested the formation of a radiolabeled metabolite, presumably [18F]spiperone, that is capable of crossing the blood-brain barrier and labeling cortical 5-HT2 receptors. This was confirmed using the ISRP method of metabolite analysis indicating [18F]PNBS is not a suitable tracer for studying D2 receptors in vivo with PET.


Asunto(s)
Radioisótopos de Flúor , Nitrobencenos/síntesis química , Espiperona/análogos & derivados , Animales , Encéfalo/metabolismo , Cromatografía Líquida de Alta Presión , Marcaje Isotópico , Ligandos , Nitrobencenos/metabolismo , Ratas , Ratas Sprague-Dawley , Receptores de Dopamina D2/metabolismo , Espiperona/síntesis química , Espiperona/metabolismo , Distribución Tisular , Tomografía Computarizada de Emisión
18.
Int J Rad Appl Instrum B ; 19(6): 651-7, 1992 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-1522019

RESUMEN

The use of internal-surface reversed-phase (ISRP) chromatography of unprocessed plasma samples was investigated as an alternative method of quantitation of the arterial plasma metabolite time course of [18F]N-methylspiperone. The ISRP method was directly compared to standard solid phase extraction/HPLC (SPE/HPLC) methods currently in wide use. Results indicate that: (1) the ISRP method is rapid and minimizes sample preparation; (2) recovery of radioactivity from the ISRP column is greater than 90%; (3) no radioactivity remains associated with chromatographically size excluded proteins and (4) the quantitative results are well correlated with conventional SPE/HPLC methods.


Asunto(s)
Radioisótopos de Flúor/sangre , Espiperona/análogos & derivados , Animales , Proteínas Sanguíneas/metabolismo , Centrifugación/métodos , Cromatografía/métodos , Cromatografía Líquida de Alta Presión/métodos , Estudios de Evaluación como Asunto , Humanos , Papio , Unión Proteica , Ratas , Ratas Endogámicas , Espiperona/sangre , Tomografía Computarizada de Emisión
19.
ASAIO J ; 38(3): M151-3, 1992.
Artículo en Inglés | MEDLINE | ID: mdl-1457836

RESUMEN

Patients bridged to transplantation with ventricular assist devices (VADs) often require prolonged support. To reduce complications associated with bed rest, the authors developed a program to mobilize patients with VADs. Between August 1986 and May 1992, 25 men and 7 women aged 12-65 years (mean: 42.4 years) were bridged for possible transplantation. The 32 patients were supported with either a Novacor (n = 9) or a Thoratec (n = 23) VAD. Thirty-one patients were turned within 2-12 hr of VAD insertion and received range of motion therapy. Twenty-six patients sat in a chair 2-16 days (mean: 5 days) after VAD insertion. Twenty-one patients used a stationary bicycle, and 23 patients were ambulatory 3-57 days (mean: 11 days) after VAD insertion. Two patients were transplanted within 72 hr of device insertion. Twenty-one of the 23 ambulatory patients were successfully transplanted or weaned from the VAD and discharged from the hospital. Two ambulatory patients who were difficult to rehabilitate (ambulatory 22 and 57 days, respectively, after VAD insertion) died before transplantation. In conclusion, VAD patients should be mobilized early because the VAD can improve exercise capability and survival rate.


Asunto(s)
Terapia por Ejercicio , Corazón Auxiliar , Adolescente , Adulto , Anciano , Ciclismo , Niño , Terapia por Ejercicio/métodos , Femenino , Trasplante de Corazón , Humanos , Masculino , Persona de Mediana Edad , Terapia Pasiva Continua de Movimiento , Estudios Retrospectivos
20.
ASAIO Trans ; 37(3): M516-7, 1991.
Artículo en Inglés | MEDLINE | ID: mdl-1751260

RESUMEN

The effect of ventricular arrhythmias (VA) on survival was retrospectively reviewed in 41 patients (33 men, 8 women) who were supported with Thoratec ventricular assist devices (VAD [Thoratec Medical Inc., Berkeley, CA]) (17 left, 9 right, and 15 biventricular). Ages ranged from 15 to 71 years (mean, 56 years), and duration of support was 0.1-17 days (mean, 4.7 days). There was no significant difference in age, gender, or type of support between survivors and nonsurvivors, and no correlation between the type of support and incidence of VA. Only two patients (both on left ventricular assist devices [LVAD]) died as a direct result of VA. There was no significant difference in the occurrence of VA before or during VAD support between survivors and nonsurvivors. These data show that evidence of VA is not a predictor of survival in patients in whom myocardial recovery is expected.


Asunto(s)
Ventrículos Cardíacos/fisiopatología , Corazón Auxiliar , Choque Cardiogénico/fisiopatología , Choque Cardiogénico/terapia , Taquicardia/fisiopatología , Adolescente , Adulto , Anciano , Electrocardiografía , Femenino , Paro Cardíaco/mortalidad , Paro Cardíaco/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Choque Cardiogénico/mortalidad , Tasa de Supervivencia , Taquicardia/mortalidad , Fibrilación Ventricular/mortalidad , Fibrilación Ventricular/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA