Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Pharm Biomed Anal ; 30(3): 643-49, 2002 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-12367689

RESUMEN

A high-performance liquid chromatography isocratic procedure was developed for the assay of cefetamet pivoxil hydrochloride in drug substance and powder for oral suspension. The method validation yielded good results and included the range, linearity, precision intra- inter-day, accuracy, specificity, LOD and LOQ values. The chromatographic system consisted of a C(18) absorbosphere column (150 x 4.6 mm i.d., 5 microm particle size), a mobile phase composed of water-acetonitrile-methanol-phosphate buffer, pH 3.5 (50:35:10:5, v/v), flow rate of 1.5 ml min(-1) and UV detection at 254 nm. The relative standard deviation varied between 0.03 and 1.76%, and accuracy of 100.09% was found. Calibration curve was linear from 30.0-80.0 microg ml(-1); its correlation coefficient was 0.99989.


Asunto(s)
Ceftizoxima/análogos & derivados , Ceftizoxima/análisis , Administración Oral , Ceftizoxima/química , Química Farmacéutica , Cromatografía Liquida/métodos , Polvos
2.
J Pharm Biomed Anal ; 30(2): 175-80, 2002 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-12191701

RESUMEN

A LC method has been developed for the quantitative determination of Oxiconazole (Ox) in bulk form, lotion and cream pharmaceutical formulations. The method validation yielded good results including the range, linearity, precision, accuracy, recovery, specificity, robustness, limit of quantitation and limit of detection. The LC separation was carried by reversed phase chromatography using a LiChrocart C(8) column (125 mm x 4.0 mm i.d., 5 microm particle size). The mobile phase was composed of methanol-0.02 M ammonium acetate buffer (85:15 v/v), pumped isocratically at flow rate 1 ml min(-1). The detection was carried out on UV detector at 254 nm. The calibration curve for Ox was linear from 40.0-140.0 microg ml(-1) range. The precision of this method, calculated as the relative standard deviation (R.S.D.) was 1.57% for lotion and 0.71% for cream. The R.S.D. values for intra- and inter-day precision studies were 0.57 and 1.34%, respectively. The recovery of the drug ranged between 98.84-102.2% (lotion) and 100.54-101.59% (cream). The stability indicating capability of the assays was proved using forced degradation. Chromatograms showed Ox well resolved from the degradation product.


Asunto(s)
Imidazoles/análisis , Química Farmacéutica , Cromatografía Líquida de Alta Presión/métodos , Cromatografía Líquida de Alta Presión/estadística & datos numéricos , Imidazoles/química , Preparaciones Farmacéuticas/análisis , Preparaciones Farmacéuticas/química
3.
J Pharm Biomed Anal ; 28(6): 1195-9, 2002 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-12049983

RESUMEN

A simple, rapid and sensitive high-performance liquid chromatographic (HPLC) method was developed for the assay of enrofloxacin in raw material and injection. The validation method yielded good results and included the range, linearity, precision, accuracy, specificity, recovery, limit of detection (LOD) and limit quantification (LOQ) values. The HPLC separation was carried out by reversed phase chromatography on a C-18 absorbosphere column (150 x 4.6 mm i.d. 5 microm particle size) with a phase composed of sodium acetate (pH 4.7; 0.1 M): acetonitrile (60:40, v/v; pH 5.0), pumped isocratically at a flow rate of 1.5 ml min(-1). The effluent was monitored at 278 nm with the eluting solvent. The calibration graph for enrofloxacin was linear from 10.0 to 80.0 microg ml(-1).


Asunto(s)
Antiinfecciosos/análisis , Cromatografía Líquida de Alta Presión/métodos , Fluoroquinolonas , Quinolonas/análisis , Enrofloxacina
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...