RESUMEN
BACKGROUND: Because of their similar visual appearance, differentiation of left ventricular thrombotic material and myocardial wall can be difficult in contrast-enhanced coronary computed tomography (CT) angiography. OBJECTIVE: We identified typical thrombi attenuation of left ventricular thrombi with the use of CT measurement. METHODS: Over a time period of 6 years, we retrospectively identified 31 patients who showed a left ventricular thrombus in CT angiography datasets. Patients underwent routine contrast cardiac CT to investigate coronary artery disease. CT attenuation of each thrombus was assessed in the 4-chamber view. CT densities were also determined in the ascending aorta, left ventricle, and myocardial wall both in the mid-septal and mid-lateral segments. The mean CT attenuation of thrombi and the difference between attenuation in thrombi, left ventricular cavity, and myocardial wall were determined. The ratio of attenuation values in thrombus versus aorta and myocardium versus aorta were also determined. RESULTS: Mean (±SD) CT attenuation of all left ventricular thrombi in 31 patients was 43.2 ± 15.3 HU (range, 25-80 HU). Mean CT densities of septal and lateral myocardial wall were 102.9 ± 23.1 HU (range, 63-155 HU) and 99.3 ± 28.7 HU (range, 72-191 HU), respectively, and were thus significantly higher than the CT attenuation of thrombi (P < 0.001). A threshold of 65 HU yielded a sensitivity, specificity, and positive and negative predictive values of 94%, 97%, 94%, and 97%, respectively, to differentiate thrombus from the myocardial wall. The mean ratio between CT attenuation of thrombus and CT attenuation within the ascending aorta was 0.11 ± 0.05 (range, 0.04-0.23), which was significantly lower compared with the mean ratio between CT attenuation of the myocardial wall and the CT attenuation within the ascending aorta. CONCLUSION: CT attenuation within left ventricular thrombi was significantly lower than myocardial attenuation in CT angiography datasets. Assessment of CT attenuation may contribute to the differentiation of thrombi.
Asunto(s)
Angiografía Coronaria/métodos , Cardiopatías/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Trombosis/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Anciano , Alemania , Humanos , Masculino , Miocardio/patología , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Factores de TiempoRESUMEN
Improvements in image quality in cardiac computed tomography may be achieved through iterative image reconstruction techniques. We evaluated the ability of "Iterative Reconstruction in Image Space" (IRIS) reconstruction to reduce image noise and improve subjective image quality. 55 consecutive patients undergoing coronary CT angiography to rule out coronary artery stenosis were included. A dual source CT system and standard protocols were used. Images were reconstructed using standard filtered back projection and IRIS. Image noise, attenuation within the coronary arteries, contrast, signal to noise and contrast to noise parameters as well as subjective classification of image quality (using a scale with four categories) were evaluated and compared between the two image reconstruction protocols. Subjective image quality (2.8 ± 0.4 in filtered back projection and 2.8 ± 0.4 in iterative reconstruction) and the number of "evaluable" segments per patient 14.0 ± 1.2 in filtered back projection and 14.1 ± 1.1 in iterative reconstruction) were not significant different between the two methods. However iterative reconstruction had a lower image noise (22.6 ± 4.5 HU vs. 28.6 ± 5.1 HU) and higher signal to noise and image to noise ratios in the proximal coronary arteries. IRIS reduces image noise and contrast-to-noise ratio in coronary CT angiography, thus providing potential for reducing radiation exposure.
Asunto(s)
Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador , Tomografía Computarizada por Rayos X , Adulto , Anciano , Artefactos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Dosis de RadiaciónRESUMEN
A 61-year-old female patient presented with sub acute myocardial infarction with an occluded right coronary artery on invasive evaluation and a ventricular septal rupture on echocardiogram. Cardiac computed tomography (CT) was performed to better define the septal anatomy. As the anatomy on cardiac CT was considered unfavorable for percutaneous intervention, the patient underwent successful surgical repair.
Asunto(s)
Disección Aórtica/etiología , Oclusión Coronaria/complicaciones , Aneurisma Cardíaco/etiología , Infarto de la Pared Inferior del Miocardio/etiología , Rotura Septal Ventricular/etiología , Disección Aórtica/diagnóstico , Disección Aórtica/cirugía , Procedimientos Quirúrgicos Cardíacos , Oclusión Coronaria/diagnóstico , Femenino , Aneurisma Cardíaco/diagnóstico , Aneurisma Cardíaco/cirugía , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Infarto de la Pared Inferior del Miocardio/diagnóstico , Persona de Mediana Edad , Tomografía Computarizada por Rayos X , Ultrasonografía , Rotura Septal Ventricular/diagnóstico , Rotura Septal Ventricular/cirugíaRESUMEN
A 37-year-old patient with known systemic lupus erythematous, antiphospholipid syndrome and previous pulmonary embolism presented with non-ST elevation myocardial infarction while on adequate anticoagulation therapy. The patient was further evaluated with cardiac computed tomography. A small diagonal branch occlusion was the only coronary lesion present. A partially calcified right ventricular thrombus was incidentally found. Because of the small vessel size, cardiac catheterization was deemed unnecessary, and the patient was discharged with adjustment of immunosuppressive therapy and anticoagulation.