Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Sensors (Basel) ; 23(3)2023 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-36772153

RESUMEN

Recording electrical muscle activity using a dense matrix of detection points (high-density electromyography, EMG) is of interest in a range of different applications, from human-machine interfacing to rehabilitation and clinical assessment. The wider application of high-density EMG is, however, limited as the clinical interfaces are not convenient for practical use (e.g., require conductive gel/cream). In the present study, we describe a novel dry electrode (TEX) in which the matrix of sensing pads is screen printed on textile and then coated with a soft polymer to ensure good skin-electrode contact. To benchmark the novel solution, an identical electrode was produced using state-of-the-art technology (polyethylene terephthalate with hydrogel, PET) and a process that ensured a high-quality sample. The two electrodes were then compared in terms of signal quality as well as functional application. The tests showed that the signals collected using PET and TEX were characterised by similar spectra, magnitude, spatial distribution and signal-to-noise ratio. The electrodes were used by seven healthy subjects and an amputee participant to recognise seven hand gestures, leading to similar performance during offline analysis and online control. The comprehensive assessment, therefore, demonstrated that the proposed textile interface is an attractive solution for practical applications.


Asunto(s)
Hidrogeles , Textiles , Humanos , Electromiografía , Electrodos , Piel
2.
Sensors (Basel) ; 20(18)2020 Sep 04.
Artículo en Inglés | MEDLINE | ID: mdl-32899770

RESUMEN

This paper presents a method to integrate and package an accelerometer within a textile to create an electronic textile (e-textile). The smallest commercially available accelerometer sensor (2 mm × 2 mm × 0.95 mm) is used in the e-textile and is fully integrated within the weave structure of the fabric itself, rendering it invisible to the wearer. The e-textile forms the basis of a wearable woven sleeve which is applied to arm and knee joint bending angle measurement. The integrated e-textile based accelerometer sensor system is used to identify activity type, such as walking or running, and count the total number of steps taken. Performance was verified by comparing measurements of specific elbow joint angles over the range of 0° to 180° with those obtained from a commercial bending sensor from Bend Labs and from a custom-built goniometer. The joint bending angles, measured by all three sensors, show good agreement with an error of less than ~1% of reading which provides a high degree of confidence in the e-textile sensor system. Subsequently, knee joint angles were measured experimentally on three subjects with each being tested three times on each of three activities (walking, running and climbing stairs). This allowed the minimum and maximum knee joint angles for each activity to be determined. This data is then used to identify activity type and perform step counting.


Asunto(s)
Acelerometría , Textiles , Dispositivos Electrónicos Vestibles , Humanos , Movimiento , Caminata
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA