Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Tomography ; 8(2): 550-559, 2022 02 23.
Artículo en Inglés | MEDLINE | ID: mdl-35314622

RESUMEN

This study aimed to assess the accuracy of a method of predicting post-movement root position during orthodontic treatment using a 3D digital crown/root model (3DCRM) created with pre-movement records of both cone-beam computed tomography (CBCT) and dental arch digital scans. Pre- and post-movement CBCT scans and dental arch digital scans of five patients who had completed orthodontic treatments were used in this study. The 3DCRM was superimposed onto the post-movement scanned dental arch to identify the post-movement root position (test method). Post-movement CBCT (referenced as the current method) served as the control to identify the actual post-movement root position. 3D-coordinate analysis revealed no significant differences between the test and current methods along the X and Y axes. However, the discrepancy on the Z axis (especially in cases of intrusion) was greater than that in all other directions for all three tooth types examined (p < 0.05). A strong positive correlation between the degree of discrepancy and the distance of tooth movement was observed on the Z axis (r = 0.71). The 3DCRM method showed promising potential to accurately predict root position during orthodontic treatments without the need for a second CBCT. However, root resorption, which affected the Z axis prediction, needs to be closely monitored using periapical radiographs to complement this method.


Asunto(s)
Resorción Radicular , Diente , Tomografía Computarizada de Haz Cónico/métodos , Coronas , Humanos , Resorción Radicular/diagnóstico por imagen , Corona del Diente/diagnóstico por imagen
2.
Ann Transl Med ; 10(1): 2, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35242847

RESUMEN

BACKGROUND: Globally, the direct cost of dental caries is approximately $298B yearly, consuming 5-10% of national healthcare budgets. Bitewing radiographs (BWR) are the standard method of diagnosing interproximal dental caries. In Japan, bitewing radiographs are rarely used. This retrospective observational study was conducted to measure the potential economic impact of carious lesions left undiagnosed and untreated due to this omission of bitewing radiographs. METHODS: The total number of existing carious lesions, the number of undiagnosed lesions, and costs of treating these lesions were calculated from the national database of Ministry of Health, Labor and Wellness in Japan between June 2013 and 2017. The number of affected teeth was estimated using prevalence data and undiagnosed lesions were estimated. The expense associated with treating progressed lesions was calculated using the standard Japanese fee structure. BWR trends were assessed, and analyses were performed to understand the differences between states and populations over time. RESULTS: The average number of BWR taken monthly per office was 48.3±1.1 (average ± SD). It was calculated that an average of 6,429,155 lesions went undiagnosed per month, 93.5 teeth per practice, and 1.6 teeth per patient. The cost of treating lesions that went undiagnosed and then progressed into more invasive restorations was estimated to be between $57M-$218M more (difference between NaF varnish and class II restorations), and $150M-$443M more (difference between Class II restoration and crown or crown with RCT). CONCLUSIONS: BWRs are crucial in diagnosing a significant number of carious lesions. There is considerable impact on health and cost to the national health system due to undiagnosed lesions. Practitioners need to be educated on reading and understanding BWR, and policy should be changed to cover BWR.

3.
Heliyon ; 7(7): e07507, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34355075

RESUMEN

OBJECTIVES: Magnets have many advantages in orthodontics, and our previous studies confirmed their therapeutic potential through 3D-data analysis. The aim of this study was to compare tooth movements, including rotation, obtained via magnetic and elastic forces in crowded cases in vitro. METHODS: Typodont models mimicking a crowded case were prepared. In the magnetic force-driven orthodontics (MG) group, Nd-Fe-B magnets were attached to the labial surfaces from UR4 to UL4 for attracting force, and to UR6 and UL6 for repulsing force. For the elastic force-driven orthodontic (EL) group, brackets were placed on labial surfaces from UR2 to UL2 with power-chain elastics. A NiTi archwire was used in both groups. The models were 3D scanned before and after tooth movement and exported as STL files. The pre- and post-movement STL files were superimposed. The 3D coordinates of the measurement points of the crown and root apex were obtained, and tooth displacement, 3D movements (X, Y, and Z-axis), and rotation (yaw, pitch, and roll) were calculated. Two-tailed Student's t-test was performed for comparison of the results between MG and EL groups (n = 3). RESULTS: Overall, both groups indicated similar movement and rotation to achieve the planned arch form. In the crown movement and rotation, no significant differences were observed between MG and EL groups. However, in the root movement, there was a significant difference between MG and EL groups in X and Z axis for the canines. CONCLUSIONS: Magnetic force-driven orthodontics demonstrated comparable results to elastics with less tipping movement, suggesting a potential future orthodontic modality. CLINICAL SIGNIFICANCE: This in vitro study showed the potential of magnetic force for orthodontic application. The magnetic force-driven orthodontics might provide less tipping tooth movement compared to conventional methods, such as power chains, and could be a future technique for comprehensive orthodontic treatment.

4.
Int J Pharm ; 594: 120046, 2021 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-33309832

RESUMEN

Acetaminophen, a central antipyretic and analgesic drug, is one of the most commonly used drugs among individuals of all ages throughout the world. This study pharmacokinetically and pharmacodynamically investigated the transport of acetaminophen to the central nervous system and systemic circulation after intranasal (i.n.) administration, and evaluated the potential of a transnasal acetaminophen formulation in comparison to other routes of administration. Direct transport to the brain and the pharmacological effect after the i.n. administration of acetaminophen with polyvinylpyrrolidone (PVP; a mucoadhesive agent) and poly-l-arginine (PLA; an absorption enhancer) were investigated to improve retention of the dosage solution in the olfactory epithelium region and enhance the transfer of acetaminophen to the brain. The transport of acetaminophen to the brain was rapid, and the concentration in the brain, especially the olfactory bulb, was higher after i.n. administration, resulting in a greater antipyretic effect in comparison to other routes of administration. The delivery system using PVP and PLA produced a high and prolonged antipyretic effect by enhancing the transfer of acetaminophen to the brain through suppression of the transfer to systemic circulation. Thus, this transnasal drug delivery system using PVP and PLA may be a promising method for transporting acetaminophen to the brain.


Asunto(s)
Acetaminofén , Sistema Nervioso Central , Administración Intranasal , Encéfalo , Sistemas de Liberación de Medicamentos , Humanos
5.
Materials (Basel) ; 13(16)2020 Aug 13.
Artículo en Inglés | MEDLINE | ID: mdl-32823770

RESUMEN

The goal of our study is to launch magnetic force-driven orthodontics. This continuous study investigated the influence of magnet position on tipping and bodily tooth movement, using 3D printing technology and digital analysis. Orthodontic typodont models (TMs) for space-closure were 3D printed to mimic maxillary central incisors. Nd-Fe-B magnets were placed in the middle third (Model-M), and the cervical third (Model-C), of the tooth. TMs, before and after movement, were digitally scanned and superimposed. The 3D digital coordinates (X, Y, and Z axes), and rotations (yaw, pitch, and roll) of the tooth crown and root, were calculated and compared between the two magnet position settings. Model-M showed higher rates of movement, but more rotation than Model-C (p < 0.01). The root apex of Model-M moved in the opposite direction of the crown (R = -0.29), indicating tipping movement. In contrast, the crown and root apex moved in the same direction (R = 0.56) in Model-C, indicating bodily movement. These patterns were confirmed in a typodont model of a moderate crowding case. The results validated that modifying the magnet position increased the amount of bodily tooth movement, and decreased rotation/tipping in an ex vivo setting.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...